Duct Light Commercial Series
Duct Air Conditioners
Submittal Data Sheet
Job Name:_________________________________________________________________________
Location:______________________________________________________ __________________
Engineer:___________________________________________________ _ __________________
Submitted to:_____________________________________________________________________
Submitted by:_____________________________________________________________________
Reference:_________________________________________________________________________
This warranty should be registered on our web-site www.cooperandhunter.us
within 60 days of installation. The warranty is only valid when installed by
a Licensed HVAC Technician. A warranty period of Seven (7) years on compressor to the original registered end-user. A warranty period of Five (5) years on all
parts to the original registered end user. Warranty applies only to products
remaining in their original installation location.
GENERAL FEATURES
• Flexible Installation
• Fresh Air Function
• Wired Control & Wi-Fi Connection
• Multi-Channel Air Distribution
INDOOR SPECIFICATION
Sound Preassure level (Hi/Mi/Lo)
Design pressure
Dimension (W*D*H)
Net/Gross weight
OUTDOOR SPECIFICATION
Air flow
Noise level
Dimension (W*D*H)
Net/Gross weight
CFM
dB(A)
in
Lbs
CH-60LCDTU/I (INDOOR UNIT) CH-60LCU/O (OUTDOOR UNIT)
Date:______________________________________________________________________________
Approval:__________________________________________________________________________
Сonstruction:______________________________________________________________________
Unit #:_____________________________________________________________________________
Drawing #:_________________________________________________________________________
PERFORMANCE
AND
EFFICIENCY
OPERATION TEMPERATURE RANGE
Indoor Outdoor
cooling
• Built-In Water Pump
• Golden fin for outdoor and indoor
• Lower Noise
• Higher Pipe Limits
• Slim Design
57/54/51 dB(A)
550/340 PSIG
55x34x17 in
163/189.6 Lb
4414
64.0
37.48x16.34x52.48
224.9/254.4
62〜90 ℉ 32〜86 ℉
Power supply V/Hz/Ph 208-230V/ 60Hz/ 1Ph
MCA: Minimum Circuit Ampacity; MFA: Max.fuse amps; RLA: Rated load amps
MCA A 36
MFA A 50
Input
RLA
Input
RLA
Capacity
Input
RLA A 23.5
Cooling
Capacity
SEER
EER
Input 5700
Capacity
COP
HSPF4
HSPF5
heating
ELECTRICAL
Indoor fan motor
W 420
A 3.65
Outdoor fan motor
W 126
A 1.2
Compressor
Btu/h 44697
W 3420
PIPING
Btu/h
Btu
W
Heating at 47F
Btu/h
W/W
cooling heating
5〜122 ℉ 5〜86 ℉
57000
18.0
10.0
62000
3.6
9.0
7.6
Refrigeran Type
Refrigerant precharge
Additional charge for each ft
ft
oz
R410/163
25
0.32
Refrigerant piping/Gas side in (3/8"3/4")
Max. pipe length ft 213
Max. difference in level ft 98
CH-60LCDTU/I (INDOOR UNIT)
Duct Light Commercial Series
Duct Air Conditioners
55 17 34 31.5 8.9 41.1 11 43.3 48.8 4321760K
CH-60LCU/O (OUTDOOR UNIT)
Cooper&Hunter products are subject to continuous improvements. Cooper&Hunter reserves the right to modify product design,
specifications and information in this data sheet without notice and without incurring any obligations.