Cooper&Hunter CH12SPH230V, CH09SPH115V, CH12SPH115V, CH18SPH230V, CH24SPH230V Installation Manual

SOPHIA
HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM
INSTALLATION MANUAL
Models: CH-09SPH-115VI/CH-09SPH-115VO (115V) CH-12SPH-115VI/CH-12SPH-115VO (115V) CH-09SPH-230VI/CH-09SPH-230VO (230V) CH-12SPH-230VI/CH-12SPH-230VO (230V) CH-18SPH-230VI/CH-18SPH-230VO (230V) CH-24SPH-230VI/CH-24SPH-230VO (230V) CH-30SPH-230VI/CH-30SPH-230VO (230V) CH-36SPH-230VI/CH-36SPH-230VO (230V)
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
Table of Contents
Installation Manual
0
Safety Precautions ................................... 4
Accessories
1
Installation Summary - Indoor Unit
2
3
Unit Parts
..................................................
8
..................................................
4
6
.......
10
Indoor Unit Installation
1. Select installation location ......................... 11
2. Attach mounting plate to wall ................ 12
3. Drill wall hole for connective piping ...... 12
4. Prepare refrigerant piping ......................... 14
5. Connect drain hose ..................................... 15
6. Connect signal cable .................................. 17
7. Wrap piping and cables ........................... 18
8. Connect indoor power wire ................... 18
9. Mount indoor unit ..................................... 18
.........
11
5
Outdoor Unit Installation
1. Select installation location ............... 20
2. Install drain joint ................................. 21
3. Anchor outdoor unit ......................... 22
4. Connect signal and power cables .. 23
.. 20
6
Refrigerant Piping Connection
A. Note on Pipe Length ............................................................. 25
B. Connection Instructions –Refrigerant Piping ............... 25
1. Cut pipe ............................................................................... 25
2. Remove burrs ..................................................................... 26
3. Flare pipe ends ................................................................. 26
4. Connect pipes .................................................................... 27
MC MC
........
Air Evacuation
7
1. Evacuation Instructions .......................... 29
2. Note on Adding Refrigerant ................ 30
25
.......................
29
8
Electrical and Gas Leak Checks
9
Test Run
10
European Disposal Guidelines ....... 34
....................................................
.........
31
32
Safety Precautions
Read Safety Precautions Before Installation
Incorrect installation due to ignoring instructions can cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.
This symbol indicates that ignoring instructions may cause death or serious
WARNING
CAUTION
WARNING
injury.
This symbol indicates that ignoring instructions may cause moderate injury to your person, or damage to your unit or other property.
This symbol indicates that you must never perform the action indicated.
Do not modify the length of the power supply cord or use an extension cord to power the unit.
Do not share the electrical outlet with other appliances. Improper or insucient power supply
can cause re or electrical shock.
When connecting refrigerant piping, do not let substances or gases other than the specied
refrigerant enter the unit. The presence of other gases or substances will lower the unit’s capacity, and can cause abnormally high pressure in the refrigeration cycle. This can cause explosion and injury.
Do not allow children to play with the air conditioner. Children must be supervised around the
unit at all times.
1. Installation must be performed by an authorized dealer or specialist. Defective installation can cause water leakage, electrical shock, or re.
2. Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or re. (In North America,installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.)
Contact an authorized service technician for repair or maintenance of this unit.
3.
Only use the included accessories, parts, and specied parts for installation. Using non-standard
4. parts can cause water leakage, electrical shock, re, and can cause the unit to fail.
5. Install the unit in a rm location that can support the unit’s weight. If the chosen location cannot support the unit’s weight, or the installation is not done properly, the unit may drop and cause serious injury and damage.
Page 4
WARNING
6. For all electrical work, follow all local and national wiring standards, regulations, and the Installation Manual. You must use an independent circuit and single outlet to supply power. Do not connect other appliances to the same outlet. Insucient electrical capacity or defects in electrical work can cause electrical shock or re.
7. For all electrical work, use the specied cables. Connect cables tightly, and clamp them securely to prevent external forces from damaging the terminal. Improper electrical connections can overheat and cause re, and may also cause shock.
8.
All wiring must be properly arranged to ensure that the control board cover can close properly. If the control board cover is not closed properly, it can lead to corrosion and cause the connection points on the terminal to heat up, catch re, or cause electrical shock. In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed
9. air-conditioning units is highly recommended.
10.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard. This appliance can be used by children aged from 8 years and above and persons with reduced Physical,
11. sensory or mental capabilities or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
CAUTION
For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of
any combustible materials.
Do not install the unit in a location that may be exposed to combustible gas leaks. If combustible
gas accumulates around the unit, it may cause re.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Too
much exposure to water can cause electrical components to short circuit.
1. The product must be properly grounded at the time of installation, or electrical shock may occur.
2. Install drainage piping according to the instructions in this manual. Improper drainage may cause water damage to your home and property.
Note about Fluorinated Gasses
1. This air-conditioning unit contains fluorinated gasses. For specic information on the type of gas and the amount, please refer to the relevant label on the unit itself.
2.
Installation, service, maintenance and repair of this unit must be performed by a certified technician.
3. Product uninstallation and recycling must be performed by a certified technician.
4.
If the system has a leak-detection system installed, it must be checked for leaks at least every 12 months.
5. When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
Page 5
Accessories
1
The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock and re, or cause the equipment to fail.
Name
Mounting plate
Clip anchor
Mounting plate xing screw ST3.9 X 25
Remote controller
Fixing screw for remote controller holder ST2.9 x 10
Remote controller holder
Shape Quantity
1
5
5
ON/OFF
TEMP
MODE
SILENCE FP
FAN SPEED
SWING
TIMER
SWING
ON
TIMER
SLEEP
OFF
TURBO
LED
SELF
FOLLOW
CLEAN
ME
RESET
LOCK
1
2
1
Optional Parts
Dry battery AAA.LR03
Air freshening lter
Seal
Drain joint
Page 6
2
1
1
(for cooling & heating
models only)
Name
Owner’s manual
Installation manual
Quick Start Guide
Shape Quantity
SOPHIA
HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM
Models: CH-S30FTXW-SV (230V) CH-S36FTXW-SV (230V)
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
SOPHIA
HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM
Models: CH-S30FTXW-SV (230V) CH-S36FTXW-SV (230V)
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
SOPHIA
HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM
Quick-Start Guide
ON/OFF
TEMP
MODE
SILENCE FP
FAN SPEED
SWING
TIMER
SWING
ON
TIMER
SLEEP
OFF
TURBO
LED
SELF
FOLLOW
CLEAN
ME
RESET
LOCK
1
1
1
Connecting pipe assembly
Liquid side
Gas side
Ø
1/ 4 i n(6. 3 5mm)
Ø
3/ 8in(9. 52mm)
Ø
3/ 8in(9. 52mm)
Ø
1/ 2in(12. 7 mm)
Ø
5/ 8in(16mm)
Parts you mu st purc hase. Consu l t the dealer about the pipe si ze.
Page 7
Installation
Overview
Installation Summary - Indoor Unit
1 2
4.75in (12cm)
Select Installation Location
5.9in (15cm)
4.75in (12cm)
90.55in (2.3m)
Determine Wall Hole Position
(Page 11)
2
(Page 12)
3 4
Attach Mounting Plate
(Page 12)
Page 8 
Drill Wall Hole
(Page 12)
1(L)
2(N) 3(S)
5 6 7
Installation
Overview
8
9
Connect Piping
(Page 25)
Connect Wiring
(Page 17)
Wrap Piping and Cable
(Page 18)
Prepare Drain Hose
(Page 14)
8
STEP
Mount Indoor Unit
(Page 18)
Page 9
Installation
Overview
Unit Parts
3
Wall Mounting Plate
Front Panel
Louver
Functional Filter
(On Front of Main Filter - Some Units)
Power Cable (Some Units)
Drainage Pipe
Signal Cable Refrigerant Piping
Remote Control (Some Units)
ON/OFF
TEMP
MODE
SILENCE FP
FAN SPEED
SWING
TIMER
SWING
ON
TIMER
SLEEP
OFF
TURBO
LED
SELF
FOLLOW
CLEAN
ME
RESET
LOCK
Remote Holder
Outdoor Unit Power Cable (Some Units)
Fig. 2.1
NOTE ON ILLUSTRATIONS
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly dierent. The actual shape shall prevail.
Page 10 
Indoor Unit Installation
4
Indoor Unit
Installation
Installation Instructions – Indoor Unit
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the label on the product box to make sure that the model number of the indoor unit matches the model number of the outdoor unit.
Step 1: Select installation location
Before installing the indoor unit, you must choose an appropriate location. The following are standards that will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other
people
Firm and solid—the location will not vibrate
Strong enough to support the weight of the
unit
A location at least one meter from all other
electrical devices (e.g., TV, radio, computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or
combustible gas
Near flammable items such as curtains or
clothing
Near any obstacle that might block air
circulation
Near the doorway
In a location subject to direct sunlight
NOTE ABOUT WALL HOLE:
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample room for a wall hole (see
Drill wall hole for connective piping step)
for the signal cable and refrigerant piping that connect the indoor and outdoor units. The default position for all piping is the right side of the indoor unit (while facing the unit). However, the unit can accommodate piping to both the left and right.
Page 11 