IMPORTANT NOTE:
Read this manual carefully before installing or operating your wired remote control. Make sure to save this manual for future reference.
T able of Contents
Wall-Mounted Remote Control Wiring...............................1
Wall-Mounted Remote Control Installation ........................6
Wall-Mounted Remote Control Wiring
WARNING
The wiring should adapt to the wire control current.
Otherwise, electric leakage or overheating may occur and result in fire.
The specified cables must be used in the wiring. No
external force should be applied to the terminal. Otherwise, the wire may be damaged and heating may occur and result in fire.
CAUTION
The shielded wire must be grounded.
The connecting cable shouldn't be longer than 20 m (65.5 ft).
The remote control operates on a low-voltage circuit
loop. DO NOT connect a 220V or 380V cable to it.
Make sure the configured tubes are 30-50 cm (12-20 ft)
or more apart.
DO NOT employ an ohmmeter to detect the insulation
after wiring the remote control.
1
An overview of the wall-mounted remote control wire outlet
Top side wire outlet
Left side wire outlet
Bottom side wire outlet
Right side wire outlet
Fig. 1
1. Wiring diagram Refer to the following diagram to wire the wall-mounted
remote control to the indoor unit.
oint, 5p
Wired control
Wired j
5-Core shield cable
Fig. 2
Infrared p
RUN
Indoor u
Indoor unit
ipe
+5V
GND
nit switchboard
2