DAKOTA
Ductless Split Air Conditioners
with Heat Pump
Submittal Data Sheet
Job Name:_________________________________________________________________________ Location:______________________________________________________ __________________ Engineer:_____________________________________________________ _ ________________ Submitted to:_____________________________________________________________________ Submitted by:_____________________________________________________________________ Reference:_________________________________________________________________________
This warranty should be registered on our web-site www.cooperandhunter.us within 60 days of installation. The warranty is only valid when installed by a Licensed HVAC Technician. A warranty period of Seven (7) years on compres­sor to the original registered end-user. A warranty period of Five (5) years on all parts to the original registered end user. Warranty applies only to products remaining in their original installation location.
GENERAL FEATURES
• Wi-Fi Control
• Sleep Mode
• Compressor Heating Belt
• 46℃Heating/Freezing protection
• Extra Low Temperature Heating
INDOOR SPECIFICATION
Noise level (Hi/Mi/Lo)
Air flow
Dimension(W*D*H)
Net/Gross weight
OUTDOOR SPECIFICATION
Air flow
Noise level
Dimension (W*D*H)
Net/Gross weight
Refrigerant Type
CFM
dB(A)
in
Lbs
oz
CH-12DKT230V/I (INDOOR UNIT) CH-12DKT230V/O (OUTDOOR UNIT)
PERFORMANCE AND EFFICIENCY
OPERATION TEMPERATURE RANGE
Indoor Outdoor
cooling
• Louver Position Memory
• Refrigerant Leakage Detect
• Chasis Heating Belt
• Auto Restart Function
• High Density and Silver Ion Filters
43/36/24 dB(A)
418/324/247
32.87x7.80x11.02 in
18.52/25.35 Lbs
1180
56
31.50x13.11x21.81
88.2/93.7
R410A/52.9
Power supply V/Hz/Ph 208-230V/ 60Hz/ 1Ph
MCA: Minimum Circuit Ampacity; MFA: Max.fuse amps; RLA: Rated load amps
Refrigerant piping/Gas side in (1/4"1/2")
Max. pipe length ft 82
Max. difference in level ft 33
6290 3286
MCA A 9 MFA A 15
Input RLA
Input RLA
Capacity Input RLA A 5.65
Cooling
Capacity SEER EER
Input 960
Capacity COP Input 975W HSPF4 HSPF5
heating
ELECTRICAL
Indoor fan motor
W 50
A 0.06
Outdoor fan motor
W 63
A 0.38
Compressor
Btu/h 11430
W 870
PIPING
Btu/h
Btu
W
Heating
Btu/h
W/W
cooling heating
-3050 -3030
12000
11800
22.5 13
3.55
12
9.9
Refrigerant precharge
Additional charge for each ft
ft
oz
25
0.161
WIRING
Connection wiring 16AWG*4 Stranded, unshielded
CH-12DKT230V/I (INDOOR UNIT)
W D
DAKOTA
Ductless Split Air Conditioners
with Heat Pump
Model
C
H-12DKT230VI
CH-12DKT230V/O (OUTDOOR UNIT)
W D H
32.9in 7.8in 11.0in
Model B in
CH-12DKT230VO
31.5
13.11 21.81
34.25 20.24 13.39
A inW1 inH inD inW in
Cooper&Hunter products are subject to continuous improvements. Cooper&Hunter reserves the right to modify product design,