Cooper&Hunter CH09LCDTUI, CH18LCDTUI, CH12LCDTUI, CH60LCDTUI Installation Manual

Additional Installation Guide
(Middle Static Pressure Duct Type Air Conditioner A6)
Horizontal Installation
1.1 With Built-in pump (9K, 12K models)
Cut both ends of the rubber connective pipe into a straight one, use it to connect the drainage outlet and water pump and safety it with clamps on both ends, see the gure as Shown below. (See Fig. 1)
drainage outlet
water pump port
clamps
1.3 With Built-in pump (24K, 36K, 48K models)
Drain connector A, B & C are covered with caps originally. Connect the drainpipe to the connector D. (See Fig. 3)
Connector D
Connector A
Connector B Connector C
Fig. 3
Vertical Installation
rubber tubing
Fig. 1
1.2 With External pump (18K model only)
Drain connector A, B & C are covered with caps originally. Take the cap on drain connector B o, connect the external pump to drain connector B using a hose & two hoseclamps. Then connect the drainpipe to the connector D. (See Fig. 2) Plug the external pump to the “PUMP” pin and the water level sensor to the “CN5” to enable the pump.(See Fig.4)
2.1 No need pump (Disable pump)
Open the cover of E-Parts Box assembly, unplug the “PUMP” pin to disable the pump function, and short connect ”CN5” plug to disable the water level sensor. (See Fig. 4)
Remove the cover
Unplug the “PUMP” pin
Short connect the “CN5”
Fig. 4
Connector A
Connector B
Fig. 2
Connector C
Connector D
Hose
Page 1
2.2 Drain pipe connecting
When installed vertically (up ow), the pump must be disabled rstly. Follow the 2.1 (Fig.4) steps to disable the pump. For the unit with external pump(18K model), the whole pump assembly can be removed. Then take the cap on drain connector C o and connect the drainpipe to drain connector C. (See Fig.5 and Fig.6)
Connector C
Fig. 5
Fig. 6
Connector C
Page 2
QSTIWP-001AEN
16123000A11556
20171011