DAKOTA
Ductless Split Air Conditioners
with Heat Pump
Submittal Data Sheet
Job Name:_________________________________________________________________________
Location:______________________________________________________ __________________
Engineer:_____________________________________________________ _ ________________
Submitted to:_____________________________________________________________________
Submitted by:_____________________________________________________________________
Reference:_________________________________________________________________________
This warranty should be registered on our web-site www.cooperandhunter.us
within 60 days of installation. The warranty is only valid when installed by
a Licensed HVAC Technician. A warranty period of Seven (7) years on compressor to the original registered end-user. A warranty period of Five (5) years on all
parts to the original registered end user. Warranty applies only to products
remaining in their original installation location.
GENERAL FEATURES
• Wi-Fi Control
• Sleep Mode
• Compressor Heating Belt
• 46℃Heating/Freezing protection
• Extra Low Temperature Heating
INDOOR SPECIFICATION
Noise level (Hi/Mi/Lo)
Air flow
Dimension(W*D*H)
Net/Gross weight
OUTDOOR SPECIFICATION
Air flow
Noise level
Dimension (W*D*H)
Net/Gross weight
Refrigerant Type
CFM
dB(A)
in
Lbs
oz
CH-09DKT230V/I (INDOOR UNIT) CH-09DKT230V/O (OUTDOOR UNIT)
Date:______________________________________________________________________________
Approval:__________________________________________________________________________
Сonstruction:______________________________________________________________________
Unit #:_____________________________________________________________________________
Drawing #:_________________________________________________________________________
PERFORMANCE
AND
EFFICIENCY
OPERATION TEMPERATURE RANGE
Indoor Outdoor
cooling
• Louver Position Memory
• Refrigerant Leakage Detect
• Chasis Heating Belt
• Auto Restart Function
• High Density and Silver Ion Filters
42/33/24.5 dB(A)
418/324/247
32.87x7.80x11.02 in
18.52/25.35 Lbs
1120
55.5
31.50x13.11x21.81
88.2/93.7
R410A/52.9
Power supply V/Hz/Ph 208-230V/ 60Hz/ 1Ph
MCA: Minimum Circuit Ampacity; MFA: Max.fuse amps; RLA: Rated load amps
Refrigerant piping/Gas side in (1/4"3/8")
Max. pipe length ft 82
Max. difference in level ft 33
62〜90 ℉ 32〜86 ℉
MCA A 9
MFA A 15
Input
RLA
Input
RLA
Capacity
Input
RLA A 5.25
Cooling
Capacity
SEER
EER
Input 620
Capacity
COP
Input 835W
HSPF4
HSPF5
heating
ELECTRICAL
Indoor fan motor
W 50
A 0.06
Outdoor fan motor
W 63
A 0.38
Compressor
Btu/h 11594
W 858
PIPING
Btu/h
Btu
W
Heating
Btu/h
W/W
cooling heating
-30〜50 ℉ -30〜30 ℉
10900
9000
25
14.5
3.83
11.2
9
Refrigerant precharge
Additional charge for each ft
ft
oz
25
0.161
WIRING
Connection wiring 16AWG*4 Stranded, unshielded
CH-09DKT230V/I (INDOOR UNIT)
W D
DAKOTA
Ductless Split Air Conditioners
with Heat Pump
Model
C
H-09DKT230VI
CH-09DKT230V/O (OUTDOOR UNIT)
W D H
32.9in 7.8in 11.0in
Model B in
CH-09DKT230VO
31.5
13.11 21.81
34.25 20.24 13.39
A inW1 inH inD inW in
Cooper&Hunter products are subject to continuous improvements. Cooper&Hunter reserves the right to modify product design,
specifications and information in this data sheet without notice and without incurring any obligations.