ALICE
SERIES
Innovative Ductless Mini Split Solutions
Split Air Conditioner with Heat Pump
16 SEER
Designed for Single Zone applications like:
www.cooperandhunter.us
Official HVAC Partner
OF THE FLORIDA PANTHERS,
Hockey Club Member of NHL

ALICE
SERIES
16 SEER
World Class Performance
All Sizes ( 9,000-24,000 BTU/h)
THE ALICE FEATURES
I-Action Inverter Technology
Low Voltage Start-Up
Intelligent Defrost
Intelligent Pre-Heating
LED Display
Comfortable Sleep Mode
Auto Swing (Vertical)
Multiple Fan Speeds
Auto Clean
Dry Anti-Mildew Design
Automatic Operation
Self-Diagnosis
Memory Function
Timer
Control Lock
Fan Delay Function
°F
°F
CH09ACE115VI/
CH09ACE115VO
*
+64.4 〜+113 +64.4 〜+113 +5 〜+109 +5 〜+109 +5 〜+114 +5 〜+114.8
+5 〜+75.2 +5 〜+75.2 +5 〜+75 - +5 〜+75
Model
System Type Heat Pump
Power Supply 115V / 60Hz 115V / 60Hz 208-230V / 60Hz 208-230V / 60Hz 208-230V / 60Hz 208-230V / 60Hz
Rated Current Cooling Amps 9.0 15.0 3.9 5.4 8.3 11.5
Rated Current Heating Amps 9.5 15.5 3.4 5.1 11.8 13.0
System Performance
Cooling Capacity (Min-Max) Btu/h 9,000 (3,500-11,000) 11,800 (3,300-12,500) 9,000 (3,800-11,500) 12,000 (3,300-12,500) 18,000 (4,500-21,000) 24,000 (6,400-24,000)
Heating Capacity (Min-Max) Btu/h 9,800 (2,500-11,000) 13,000 (3,400-13,500) 9,000 (3,300-11,500) 12,000 (3,400-12,500) 19,200 (4,000-23,000) 24,200 (4,100-26,600)
SEER/EER 16 / 12.0 16 / 9.40 16 / 10.2 16 / 9.8 16 / 10.6 16 / 10.0
HSPF/COP 8.60 / 12.0 8.60 / 9.8
Indoor Unit
Air Flow CFM 330/277/224/188 341/288/235/200 330/277/224/188 341/288/235/200 471/400/330/271 589/441/306/206
Sound Pressure Level - T/H/M/L db (A) 41/37/35/32 43/39/35/32 43/38/32/26 44/39/33/28 48/43/38/34 49/43/39/34
Unit Dimension (WxHxD) inches 30.3 x 11.1 x 7.9 30.3 x 11.1 x 7.9 30.3 x 11.1 x 7.9 30.3 x 11.1 x 7.9 34.1 x 12.0 x 8.5 12.4 x 8.7 x 40.1
Package Dimension (WxHxD) inches 33.4 x 13.6 x 10.9 33.4 x 13.6 x 10.9 33.8 x 11.4 x 14.8 33.8 x 11.4 x 14.8 37.3 x 15.1 x 12.2 42.4 x 15.7 x 12.9
Net / Gross Weight lb 19 / 23 19 / 23 19 / 25 20 / 27 24 / 31 33 / 44
Outdoor Unit
Compressor Type DC Inverter-driven rotary
Sound Pressure Level db (A) 53 55 49 52 56 53
Unit Dimension (WxHxD) inches 33.4 x 21.3 x 12.6 33.4 x 21.3 x 12.6 28.0 x 21.3 x 12.5 28.0 x 21.3 x 12.5 37.6 x 27.6 x 15.6 37.6 x 27.6 x 15.6
Package Dimension (WxHxD) inches 34.7 x 23.4 x 14.3 34.7 x 23.4 x 14.3 30.5 x 23.9 x 13.8 30.5 x 23.9 x 13.8 40.5 x 29.5 x 18.5 40.5 x 29.5 x 18.0
Net / Gross Weight lb 69 / 77 69 / 77 62 / 68 66 / 73 104 / 114 115 / 126
Refrigerant / Charge oz. R410A / 35.3 R410A / 35.3 R410A / 26.1 R410A / 35.3 R410A / 52.9 R410A / 54.7
Cooling Operation Ambient
Temperature Range
Heating Operation Ambient
Temperature Range
Piping & Electrical
Line Set Size (Liquid - Suction) inches 1/4" - 3/8" 1/4" - 3/8" 1/4" - 3/8" 1/4" - 3/8" 1/4" - 1/2" 1/4" - 1/2"
Pre-Charge Feet 25 25 25 25 25 25
Max. Line Run Feet 50 50 50 50 82 82
Max. Elevation Feet 33 33 33 33 33 33
MCA
MOCP Amps 20 25 15 15 25 25
Wire Size / # Wires
Amps 12 15 10 10 15 17
AWG12 / 4
CH12ACE115VI/
CH12ACE115VO
CH09ACE230VI/
CH09ACE230VO
8.5 / 11.7
AWG16 / 4
CH12ACE230VI/
CH12ACE230VO
8.5 / 11.4 8.5 / 8.0 9.5 / 9.0
CH18ACE230VI/
CH18ACE230VO
CH24ACE230VI/
CH24ACE230VO
+5 〜+75.2
AWG12 / 4AWG14 / 4
AWG12 / 4
Test conditions are based on AHRI 210/240. Specifications are subject to change without notice. Manufacturer
reserves the right to discontinue or change at any time, specifications or designs without notice or without incurring
obligations. ©2017. All rights reserved. WAT120603S-v7