Cooper&Hunter CH09ACE230V Instruction Manual

ALICE
SERIES
Innovative Ductless Mini Split Solutions
Split Air Conditioner with Heat Pump
16 SEER
Designed for Single Zone applications like:
www.cooperandhunter.us
OF THE FLORIDA PANTHERS,
Hockey Club Member of NHL
ALICE
SERIES
16 SEER World Class Performance All Sizes ( 9,000-24,000 BTU/h)
THE ALICE FEATURES
I-Action Inverter Technology Low Voltage Start-Up Intelligent Defrost Intelligent Pre-Heating LED Display
Comfortable Sleep Mode Auto Swing (Vertical) Multiple Fan Speeds Auto Clean Dry Anti-Mildew Design
Automatic Operation Self-Diagnosis Memory Function Timer Control Lock Fan Delay Function
°F
°F
CH09ACE115VI/ CH09ACE115VO
*
+64.4 〜+113 +64.4 〜+113 +5 〜+109 +5 〜+109 +5 〜+114 +5 〜+114.8
+5 〜+75.2 +5 〜+75.2 +5 〜+75 - +5 〜+75
Model
System Type Heat Pump
Power Supply 115V / 60Hz 115V / 60Hz 208-230V / 60Hz 208-230V / 60Hz 208-230V / 60Hz 208-230V / 60Hz
Rated Current Cooling Amps 9.0 15.0 3.9 5.4 8.3 11.5
Rated Current Heating Amps 9.5 15.5 3.4 5.1 11.8 13.0
System Performance
Cooling Capacity (Min-Max) Btu/h 9,000 (3,500-11,000) 11,800 (3,300-12,500) 9,000 (3,800-11,500) 12,000 (3,300-12,500) 18,000 (4,500-21,000) 24,000 (6,400-24,000)
Heating Capacity (Min-Max) Btu/h 9,800 (2,500-11,000) 13,000 (3,400-13,500) 9,000 (3,300-11,500) 12,000 (3,400-12,500) 19,200 (4,000-23,000) 24,200 (4,100-26,600)
SEER/EER 16 / 12.0 16 / 9.40 16 / 10.2 16 / 9.8 16 / 10.6 16 / 10.0
HSPF/COP 8.60 / 12.0 8.60 / 9.8
Indoor Unit
Air Flow CFM 330/277/224/188 341/288/235/200 330/277/224/188 341/288/235/200 471/400/330/271 589/441/306/206
Sound Pressure Level - T/H/M/L db (A) 41/37/35/32 43/39/35/32 43/38/32/26 44/39/33/28 48/43/38/34 49/43/39/34
Unit Dimension (WxHxD) inches 30.3 x 11.1 x 7.9 30.3 x 11.1 x 7.9 30.3 x 11.1 x 7.9 30.3 x 11.1 x 7.9 34.1 x 12.0 x 8.5 12.4 x 8.7 x 40.1
Package Dimension (WxHxD) inches 33.4 x 13.6 x 10.9 33.4 x 13.6 x 10.9 33.8 x 11.4 x 14.8 33.8 x 11.4 x 14.8 37.3 x 15.1 x 12.2 42.4 x 15.7 x 12.9
Net / Gross Weight lb 19 / 23 19 / 23 19 / 25 20 / 27 24 / 31 33 / 44
Outdoor Unit
Compressor Type DC Inverter-driven rotary
Sound Pressure Level db (A) 53 55 49 52 56 53
Unit Dimension (WxHxD) inches 33.4 x 21.3 x 12.6 33.4 x 21.3 x 12.6 28.0 x 21.3 x 12.5 28.0 x 21.3 x 12.5 37.6 x 27.6 x 15.6 37.6 x 27.6 x 15.6
Package Dimension (WxHxD) inches 34.7 x 23.4 x 14.3 34.7 x 23.4 x 14.3 30.5 x 23.9 x 13.8 30.5 x 23.9 x 13.8 40.5 x 29.5 x 18.5 40.5 x 29.5 x 18.0
Net / Gross Weight lb 69 / 77 69 / 77 62 / 68 66 / 73 104 / 114 115 / 126
Refrigerant / Charge oz. R410A / 35.3 R410A / 35.3 R410A / 26.1 R410A / 35.3 R410A / 52.9 R410A / 54.7
Cooling Operation Ambient Temperature Range
Heating Operation Ambient Temperature Range
Piping & Electrical
Line Set Size (Liquid - Suction) inches 1/4" - 3/8" 1/4" - 3/8" 1/4" - 3/8" 1/4" - 3/8" 1/4" - 1/2" 1/4" - 1/2"
Pre-Charge Feet 25 25 25 25 25 25
Max. Line Run Feet 50 50 50 50 82 82
Max. Elevation Feet 33 33 33 33 33 33
MCA
MOCP Amps 20 25 15 15 25 25
Wire Size / # Wires
Amps 12 15 10 10 15 17
AWG12 / 4
CH12ACE115VI/ CH12ACE115VO
CH09ACE230VI/ CH09ACE230VO
8.5 / 11.7
AWG16 / 4
CH12ACE230VI/ CH12ACE230VO
8.5 / 11.4 8.5 / 8.0 9.5 / 9.0
CH18ACE230VI/ CH18ACE230VO
CH24ACE230VI/ CH24ACE230VO
+5 〜+75.2
AWG12 / 4AWG14 / 4
AWG12 / 4
Test conditions are based on AHRI 210/240. Specifications are subject to change without notice. Manufacturer
reserves the right to discontinue or change at any time, specifications or designs without notice or without incurring
obligations. ©2017. All rights reserved. WAT120603S-v7
Loading...