Convair Millenia, Megacool User Manual

4 (2)
Convair Millenia, Megacool User Manual

OWNER’S MANUAL

Portable Evaporative Cooler

MASTERCOOL

(MIC, MICH)

I L L 8 6 3 - A

ILL1222-A

I L L 8 6 3 - A

 

 

 

MEGACOOL (MIV, MIVH)

MILLENIA (MI, MIH)

(English) (MI MIH MIC MICH MIV MIVH)

®

CONTENTS

 

 

SAFETY........................................................................

 

1

General Safety

 

 

Electrical Safety

 

 

COMPONENT LOCATION...........................................

2

ASSEMBLY..................................................................

 

3-4

Caution - Check Voltage

 

 

To assemble the cooler

 

 

DIRECTIONS FOR USE..............................................

4-6

How to get the best cooling performance

 

Filling with water

 

 

Using the cooler -

Low fan speed

 

 

High fan speed

 

 

Fan only (vent)

 

Conditioning of Aspen cooling pads

 

Air direction control

 

 

Safety instructions

 

 

Cleaning the cooler/rear panel removal

 

MAINTENANCE..........................................................

..

6-7

To drain water

 

 

Water strainer and Aspen cooling pad

 

Pump belt replacement / Drain Plug

 

TROUBLESHOOTING..................................................

 

8

SPARE PARTS LIST & EXPLODED VIEW..................

9-10

WARRANTY................................................................

.

11

Waste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment.

®

i

Millenia series Portable Evaporative Cooler

SAFETY

Portable evaporative air cooler - important safety instructions

Please read these instructions before assembling the cooler and keep for future reference.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

General Safety

For indoor use only.

Use only in the upright position on a flat level surface and at least 50cm from any objects.

Clean the air inlets and outlets at regular intervals to prevent airflow reduction (refer Maintenance section).

Do not place objects on the air cooler, or through the ventilating slots or restrict the air inlets & outlets.

Closely supervise any children and pets when the air cooler is in use.

Do not store or operate the appliance near any flammable substances.

During operation, water is present in the bottom tank of the air cooler. Be careful when moving the unit to prevent water from spilling.

Always switch your cooler off and unplug it before cleaning or maintenance.

Electrical Safety

Caution! before connecting the electrical power cord to a power outlet, check that the air cooler voltage is the same as your power supply (refer to the rating label located on the rear of the unit).

Do not pull the unit along by the power cord or place the power cord near a source of heat. Always unroll the power cord completely before use.

If the power supply cord is damaged it must be replaced by the manufacturer, a service agent or similarly qualified persons in order to avoid a hazard.

Switch off and unplug when not in use.

SEELEY INTERNATIONAL – OWNER’S MANUAL

1

 

 

COMPONENT LOCATION

KEY

A Controls

BFront grille

C Water filling door

DWater reservoir

ECastors

FWater level indicator

GFront pillar (Millenia, Megacool)

HBase

I Rear panel retaining screws (2)

JRear panel

K Power cord entry point

L Reservoir drain plug

MRating label

NCord storage hooks

ORear pillar (Millenia, Megacool)

A

B

C F

D G

E H

I L L 8 6 4 - A

I

J

K M

L N

O

I L L 8 6 5 - B

®

2

Millenia series Portable Evaporative Cooler

ASSEMBLY

CAUTION! - Check Voltage

Before connecting your electrical power cord to a power outlet, check that the cooler voltage is the same as your power supply. The cooler voltage will be stated on the rating label at the rear of the cooler (Fig 6).

To assemble the cooler

Push the four castors into their locating holes in the base. Use a rotating motion to assist in the entry of the steel spring ring (“*” Fig 7).

Models Millenia and Megacool only

Assemble the front and rear pillars and screw together. Place this assembly on the base and slide into position until it locks (Fig 8).

Models Millenia and Megacool only

Place the reservoir of the cooler onto the front pillar as shown (Fig 9). Tilt downwards towards the rear until the reservoir locks onto the rear pillar.

To remove the unit from the pillars, use a screwdriver in the two recesses in the rear of the reservoir to release the clips. Tilt the unit forward to remove.

6

I L L 8 6 6 - A

7

*

ILL867-B

8

ILL1221-A

9

ILL870-A

SEELEY INTERNATIONAL – OWNER’S MANUAL

3

 

 

Loading...