Contacta has a policy of continuous product development, therefore small specication changes
may not be reected in this manual. Images, labels, packaging, accessories and product colours
are subject to change without notice.
2
Product Overview
Our highly eicient and compact V7, V15 and V15a hearing loop drivers
are suitable for smaller facilities and venues.
The V7 and V15 are constant current hearing loop drivers which power
hearing loops utilising a single output. The V15a is a constant current
dual output hearing loop driver with integral phase shifter for phased
array conguration.
These hearing loop drivers have Class-D amplier output stages and
an audio subsystem built around an advanced DSP core. Combined
with a powerful CPU that ensures peak performance, they use cutting
edge technology proven in the pro audio world to achieve life-like
speech and rst-class music reproduction.
Note: For large area hearing loop installation instructions, consult the
Large Area Hearing Loop Installation Guide.
3
V7
Components
3
2
1
5
6
4
1. Rubber Feet x4
2. 5.08mm Euro-Block Connector
3. 3.81mm Euro-Block Connector x2
4. Signage
V15
3
2
1
4
1. Rubber Feet x4
2. 5.08mm Euro-Block Connector
3. 3.81mm Euro-Block Connector x2
4. Signage
5
6
7
5. V7 Hearing Loop Driver
6. Installation & User Guide
7. Power Supply [PS-55]
8. IEC Power Lead
7
5. V15 Hearing Loop Driver
6. Installation & User Guide
7. Power Supply [PS-60]
8. IEC Power Lead
8
*
8
*
*
Plug type varies by country.
4
V15a
3
2
1
5
6
4
1. Rubber Feet x4
2. 5.08mm Euro-Block Connector x2
3. 3.81mm Euro-Block Connector x2
4. Signage
7
8
5. V15a Hearing Loop Driver
6. Installation & User Guide
7. Power Supply [PS-60]
8. IEC Power Lead
*
*
Plug type varies by country.
Cable & Equipment: A length of loop cable determined by the loop
design is also required. Hearing loop drivers also require ancillary
equipment for audio feeds, such as a microphone or sound system.
5
Connections
Rear Panel Connections
12
1. Microphone Input - 3.81mm Euro-block balanced microphone
input (12V phantom power via 680Ω).
2. Line Input 1* - 3.81mm Euro-block balanced line input/feedthrough.
3. Line Input 2* - XLR balanced line input/feedthrough.
4. Power Supply Input - *V7 DC Power Input, 2.1mm 14Vdc 2.14A
***V15 DC Power Input, 2.1mm 24Vdc 4.17A **V15a DC Power Input, 2.1mm 24Vdc 4.17ACaution: Use only the provided Power Supply.
5. Loop A Output - 5.08mm Euro-block.
6. Loop B Output - 5.08mm Euro-block [V15a only].
*
Note: Only connect to one Line Input at a time.
3
4
5
6
6
Connection Examples
XLR to XLR (line)
TRS to XLR (line)
Unbalanced to XLR
XLR to Euroblock (balanced)
Unbalanced to Euroblock
7
Suitable Cable Lengths
The tables in this section show the approximate maximum cable
lengths for diering maximum required currents.
Loop impedance (at 1.6kHz) should be less than the voltage capability
of the driver (V7: 7.5Vrms, V15: 15Vrms, V15a: 15Vrms) divided by the
required current.
This achieves 400mA/m eld strength at 1kHz.
V7 Single-Turn Hearing Loop (Metric)
Current2.0A3.0A4.0A5.0A
Cable TypeCable Length
Maximum
Cable
Length
Round
Cable
(CSA)
Flat Cable
(Width)
0.5mm85m56m42m34m
1mm133m89m66m53m
1.5mm155m103m77m62m
2.5mm173m115m86m69m
10mm101m67m50m40m
12.5mm192m128m96m77m
25mm255m170m127m102m
V7 Single-Turn Hearing Loop (Imperial)
Current2.0A3.0A4.0A5.0A
Cable TypeCable Length
Maximum
Cable
Length
Round
Cable
(AWG)
Flat Cable
(Width)
18AWG438ft292ft219ft175ft
14AWG593ft395ft296ft237ft
18AWG
(equivalent)
14AWG
(equivalent)
505ft336ft252ft202ft
711ft474ft355ft284ft
8
V15 Single-Turn Hearing Loop (Metric)
Current2.0A3.0A4.0A5.0A
Cable TypeCable Length
Maximum
Cable
Length
Round
Cable
(CSA)
Flat Cable
(Width)
1mm242m161m121m97m
1.5mm284m189m142m114m
2.5mm319m213m160m128m
10mm180m120m90m72m
12.5mm340m226m170m136m
25mm450m300m225m180m
V15 Single-Turn Hearing Loop (Imperial)
Current2.0A3.0A4.0A5.0A
Cable TypeCable Length
Maximum
Cable
Length
Round
Cable
(AWG)
Flat Cable
(Width)
18AWG746ft498ft373ft299ft
14AWG997ft664ft498ft399ft
18AWG
(equivalent)
14AWG
(equivalent)
840ft560ft420ft336ft
1327ft885ft663ft531ft
9
V15a Single-Turn Hearing Loop (Metric)
Current2.0A3.0A4.0A5.0A
Cable TypeCable Length
Maximum
Cable
Length
Round
Cable
(CSA)
Flat Cable
(Width)
1mm266m177m133m106m
1.5mm311m208m156m125m
2.5mm350m233m175m140m
10mm197m131m99m79m
12.5mm373m249m186m149m
25mm493m329m247m197m
V15a Double-Turn Hearing Loop (Metric)
Current2.0A3.0A4.0A5.0A
Cable TypeCable Length
Maximum
Cable
Length
Round
Cable
(CSA)
Flat Cable
(Width)
1mm193m129m97m77m
1.5mm209m139m104m83m
2.5mm219m146m110m88m
10mm172m115m86m69m
12.5mm267m178m133m107m
25mm316m211m158m126m
10
V15a Single-Turn Hearing Loop (Imperial)
Current2.0A3.0A4.0A5.0A
Cable TypeCable Length
Maximum
Cable
Length
Round
Cable
(AWG)
Flat Cable
(Width)
18AWG819ft546ft409ft328ft
14AWG1093ft729ft547ft437ft
18AWG
(equivalent)
14AWG
(equivalent)
921ft614ft461ft369ft
1456ft971ft728ft582ft
V15a Double-Turn Hearing Loop (Imperial)
Current2.0A3.0A4.0A5.0A
Cable TypeCable Length
Maximum
Cable
Length
Round
Cable
(AWG)
Flat Cable
(Width)
18AWG598ft399ft299ft239ft
14AWG684ft456ft342ft273ft
18AWG
(equivalent)
14AWG
(equivalent)
723ft482ft362ft289ft
949ft633ft475ft380ft
11