The information in this publication is subj ect to change without notice.
COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS
OR OMISSIONS CONTAINED HERE IN, NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE S
RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIAL. T HIS INFORMATION
IS PROVIDED “AS IS” AND COMPAQ COMPUTER CORPORATION DISCLAIMS ANY W ARRANT IE S ,
EXPRESS, IMPLIED OR STATUTORY AND EXPRESSLY DISCLAIMS THE IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR PARTICULAR P URPOSE, GOOD TITLE AND AGAINST
INFRINGEMENT.
This publication contains information protected by copyright. No part of this publicati on may be photocopied or
reproduced in any form w ithout prior w r itten consent from Compaq Computer Corporation.
1999 Digital Equipment Corpor ation. All rights reser ved. Printe d in the U.S.A.
The software des cribed in this guide is furnished under a license agreement or nondi s closure agreement. The software
may be used or copied only in accor dance with the terms of the agreement.
Compaq, the Compaq logo, and the Digital logo registered in United S tates Patent and Trademark Office.
AlphaServer, DIGITAL, Tru64 UNIX, DECevent, DEChub, H U Bwatch, LA75 Plus Companion, RX, RZ,
StorageWorks , and ThinWir e , are trademarks of Compaq Computer Corporation.
The followi ng ar e third-party trademarks:
Access I/O is a registered tr ademark of Access I/O C or poration.
Amphenol is a regi s tered trademark of C anadian Imperial Bank of Commerce (N.Y. Agent).
Dialogic is a registered tr ademark and D/121B, DT I /211, DTI/212, LSI/120, and PEB are t rademarks of Dialogic
Corporation.
Microsoft and Windows are registered trademarks and Windows NT is a trademark of Mi cr os oft Corporation.
UNIX is a registered trademar k in the United States and other countr ies licensed exclus ively through X/Open C ompany
Ltd.
All other trademarks and regist ered trademarks are t he pr operty of their r es pective owners.
S3757
FCC Notice: This equipment gener ates, uses, and may emi t radio frequency energy. The equipment has been t ype
tested and found to comply with the l imits for a Class A digi tal device pursuant to Part 15 of FCC rules, which are
designed to provide reasonable protection against such radio frequency interference.
Operation of t his equipment in a residential area may cause interference in w hich case the user at his ow n expens e w ill
be required to take w hatever measures may be required to correct the interference.
Any modifications to this device - unless express ly approved by the manufacturer - can void the user’ s authority to
operate this equipment under part 15 of the FCC rul es.
Note: Additional information on the need to interconnect the devi ce w ith shielded (dat a) cables or the need for s pecial
devices, such as fer rite beads on cables, is required i f such means of interf e r ence s uppression was used in the
qualification test for the device. This information will vary from device to device and needs to be obtained from the
EMC group or pr oduct manager.
EMI Notice: This product complies with the f ollowing domesti c and international s tandards:
• Domestic: FCC Part 15, Class A
• Internati onal: CISPR22 (Europe EN 55022 Class A).
EC Notice:
Warning! This is a Class A product. In a domestic environment this product may cause radio interference in whi ch
case the user may be requir e d to take adequate measures.
Achtung! Dieses ist ein Gerät der Funkstör gr e nzw ertklasse A. In Wohnbereichen können bei B e trieb dieses G erätes
Rundfunkstörungen auftreten, i n w elchen Fällen der Benutzer für ent s pr echende Gegenmaßnahmen verantwortlich ist.
Attention! Ceci est un produi t de Classe A. D ans un environnement domestique, ce produit ri s que de créer des
interférences radioélectriques, il appartiendra alors à l'utilisateur de prendre les mesures spécifiques appropriées.
ACOUSTICS:
Preliminary declared values per I SO 9296 and ISO 7779:
Sound Power Level
, B
L
wAd
Sound Pressure Level
L
, dBA (Bystander Positions))
pAm
Idle6.550
Operating6.550
Current values for specific configurations are avai lable from Compaq repr es entatives. 1 B = 10 dBA.
1.3 System Features...................................................................................................................................1–4
1.3.1 User Interfaces...........................................................................................................................1–4
2.3 Site Preparation...................................................................................................................................2–2
Table B–1: Alarm Control Module 8-Pin MJ Connector Pinout............................................................... B–2
Table C–1: Field Wire Recommendations for Each Power Feed..............................................................C–2
viii
About This Guide
The AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide describes how to
set up, operate, troubleshoot, and maintain an AlphaServer Intelligent Peripheral (IP)Platform. If information is available elsewhere, this manual provides a reference to the
appropriate documentation.
Intended Audience
This manual is intended for qualified system managers and technical end users trained in the
installation and the servicing of computer systems.
Structure of This Document
This guide is organized as follows:
Chapter 1, Product Overview – Describes the basic AlphaSe rver IP P l atf orm
configurations, the required and optional hardware, and the factory-installed software.
Chapter 2, Installing the AlphaServer IP Platform Software – Provides instructions for
installing the AlphaServer IP Platform hardware.Chapter 3, Basic Operation – Describes how to turn on the AlphaServer IP Pl at form.
Preface
Chapter 4, Reconfiguring the AlphaServer IP Platform – Explains how to reconfigure the
AlphaServer IP Platform.
Chapter 5, System Troubleshooting – Provides basic troubleshooting information.
Appendix A, AlphaSe r ve r P latform Specifications – Provides system and environmental
specifications.
Appendix B, Al a r m Input W iring – Provides a wiring diagram of all of the alarm inputs and
wiring information for user alarm inputs.
Appendix C, Field Wiring the -48 Vdc Power Inverter – Provides field wiring details for
the -48 Vdc power controllers.
Appendix D, AlphaSer v e r IP P l atfor m Dupl e x Syste m Di agr ams – Contains diagrams of
the IP duplex platforms.
Appendix E, AlphaSer v e r IP P l atfor m Dupl e x Syste m Di agr ams – Contains diagrams of
the IP simplex platforms.
The Glossary defines technical terms related to the product.
The Index locates the main topics in this guide.
ix
Conventions
This document uses the following c onve nti ons:
ConventionMeaning
IP
Note
Caution
Warning
➊
Italic type
Related Documen tation
Describes an industry-st andard acr onym for Int e lligent Peripheral.
A note calls the reader’s attention to any item of information that may be of
special importance.
A caution contains informat i on esse nti al t o avoi d dam age t o the equi pm ent .
A warning contains information es sent i al t o t he saf et y of per sonnel .
Circled numbers provide a li nk bet ween figur es or exam pl es and t ext .
Italic type emphasi zes i m port ant i nfor mat i on, i ndicat es vari abl es, and
indicates complete titles of manuals.
For additional information on the
AlphaServer Intelligent Peripheral (IP) Platform
subsystem
components and related software, refer to the documentation in the following table. Order
numbers may change as documents are revised or updated. Check with your Compaq sales
representative for additional information.
DocumentPart Number
AlphaServer IP Platform
Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's
Guide
AlphaServer Intelligent Peripheral Platform System Manager's Guide
AlphaServer 1000A Processor
AlphaServer 1000A Rackmount Owner’s Guide
DIGITAL UNIX Installa tion Guide
StorageWorks KZPSA PCI-to-SCSI Adapter User’s Guide
Site Environmental Preparation Guide
BA35x-Sx Modular Storage Shel f
BA350 Modular Storage Shelf Subsystem User’s Guide
BA350 Modular Storage Shelf Subsyst em Configurat i on Guide
DWZZB SCSI Signal Converter User’s Guide
RZ Series Disk Drive Installati on Guide - M odels RZ35, RZ26, RZ27, RZ28
-48 Vdc Power Inverter
DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac Power Inverter Owner's Guide
The AlphaServer Intelligent Peripheral (IP) Platform provides a full suite of hardware and
software components for voice processing, telephony and data communications, management,
processing, and storage. The se c ompone nt s are c om bine d t o ma ke a hi gh pe rforma nc e, hi gh
availability, rackmount-configured IP Platform, that meets certain standards and
specifications.
There are two basic AlphaServer IP Platf orm configurations upon which all platform systems
are built:
1
Product Overview
•
IP Simplex System
•
IP Duplex System
There may also be custom variations of the IP platform.
Each rackmount platform requires a console terminal to display all system alarm messages
and manage alarm conditions.
Basic AlphaServer IP Platform management functions are designed to ensure the integrity of
the platform and to allow for the management of the platform itself. The management
functions include alarming based on critical events, for example; hardware failure, logging of
events and activities, management of the individual resources, and system security. These
functions are described in t he Intelligent Peripheral Fault Manager for Tru64 UNIXInstallation and User's Guide.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide 1–1
Product Overview
1.2.1 IP Simplex System
The simplex system is a central office compatible rackmount system intended for Telco
central office environments. It contains one each of the following components:
• AlphaServer 1000A system running the Compaq Tru64 UNIX (formerly DIGITAL
UNIX) opera t ing system
•
ISA bus expansion chassis
•
Alarm indicator panel
• StorageWorks BA35x-Sx mass storage disk drive subsystem (optional)
•
Rackmount power controller (120 Vac, 250 Vac, or -48 Vdc models)
Refer to Appendix E for diagrams of the IP simplex system.
1.2.2 IP Duplex System
The duplex rackmount configuration is a central office compatible rackmount system
intended for Telco central office environments and is suitable for live network
implementations. The duplex system includes two each of the following components:
• AlphaServer 1000A system running the Tru64 UNIX operating system
•
ISA bus expansion chassis
•
Alarm indicator panel
• StorageWorks BA35x-Sx mass storage disk drive subsystems (optional) (connected
together with BN21W-0B and BN21K-XX SCSI bus cables) with disks that can be
striped and/or mirrored
•
Two rackmount power controllers (120 Vac, 250 Vac) or one rackmount power controller
(-48 Vdc)
TruCluster software can be ordered separately and is recommended for enhanced availability
with application-defined failover services.
Refer to Appendix D for diagrams of the IP duplex system.
1–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1.2.3 Factory Installed Software
The IP platform supplied by Compaq Computer Corporation is delivered to the customer with
the following factory-installed software:
• Tru64 UNIX operating system
•
Dialogic drivers for Tru64 UNIX that offer the following functionality:
• TruCluster Available Server for Tru64 UNIX (optional)
• Intelligent Peripheral Fault Manager (IPFM) for the Tru64 UNIX operating system
Product Overview
• DECevent Translation Utility
All systems include the IP Fault Manager software that detects various system events and
performs pre-configured actions for each event.
Solution developers can also use the IP Fault Manager to display application alarmed events
on the IP alarm panel and to log events. A complete description of the IP Fault Manager is
included in the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User'sGuide.
For additional information on how to use the factory-installed software, refer to the individual
product's documentation.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–3
Product Overview
1.3 System Features
This section provides a brief description of the system features of the AlphaServer IP
Platform.
1.3.1 User Interfaces
The AlphaServer IP Platform is designed to work in real-time public networks of
telecommunications service providers. System and network management activities are
performed by means of a separate data communications network rather than the telephony
communications network (for example, voice or signaling). Both graphical user interfaces
(GUIs) and character cell displays are supported, depending on the interfaces provided by the
layered products on the IP Platform.
Command line or character cell displays are used for objects that do not have a GUI, or as a
supplement to those with a GUI. Command line interfaces can be run over a low-speed dialup modem with minimal communication protocol support.
1.3.2 Alarm Subsystem
The alarm subsystem of the AlphaServer IP Platform provides alarming functions to the
platform. These functions include the following:
•
Visual indication of an alarmed event
•
Audible indication of an alarmed event
•
Programmable external event notification
•
Diagnostic capability
•
Battery-backup for alarm indicators
•
Programmable software interface with interrupt capability
•
Dry contacts for remote monitoring of alarms
The alarm subsystem is comprised of two physical modules: an alarm control module that
resides on the PCI bus, and an alarm indicator panel, which contains all of the visual and
audible indicators.
1.3.3 Maintainability
All configurations are designed with front access for all user devices contained in the
AlphaServer 1000A system, the ISA bus expansion chassis, and the modular storage shelf
BA35x-Sx subsystem. All nonuser devices have rear access.
The AlphaServer 1000A system and the ISA bus expansion chassis are slide mounted for ease
of maintenance.
The BA35x-Sx application storage disks are hot-swappable.
1.3.4 Reliability
Each Compaq Computer Corporation component of this system will function reliably over
time as long as the hardware options used are not altered. All of the Compaq options used in
the design of this system meet Compaq Computer Corporation standards for reliability.
However, the reliability of the equipment supplied by other vendors is determined by the
manufacturer of each device.
1–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1.3.5 Upgrading
Additional hardware and software opt i ons may be a dded t o your A l phaServe r IP P lat f orm
components. For a complete list of available options, refer to the individual component's
documentation listed in the Related Documentation section of the Preface in this guide.
___________________________ Important _________________________
FCC and safety review is valid only for options listed in this guide.
1.3.6 Compaq Computer Corporation and Industry Standards
The AlphaServer IP Platform conforms to the industry standards outlined in the following
subsections.
1.3.6.1 Telecommunications Interfaces
The AlphaServer IP Platform conforms to the following telecommunications interface
standards when Telephony boards are installed:
•
T-1 (24-channel, PCM encoded analog) digital network interface
•
E-1 (30-channel, PCM encoded analog) digital network interface
Product Overview
•
Loop-start signaling
•
Ground-start signaling
•
E&M wink-start signaling
1.3.6.2 Safety and Electromagnetic Compatibility
The AlphaServer IP Platform conforms to the following safety and electromagnetic
compatibility standards:
•
FCC Part 15, Subpart J
•
CSA (Canad i an Standards Association) C22.2 No. 950-93
•
UL (Underwriters Laboratory) 1950
•
TUV EN 60950
•
CE Class A
•
C-Tick Mark
•
BSMI
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–5
Product Overview
1.3.7 System Security
The AlphaServer IP Platform contains front and rear key locking doors to limit access to
system components. Each AlphaServer IP Platform comes with a duplicate set of front and
rear door keys.
In addition, each AlphaServer 1000A system contains a key to lock the individual processor.
Refer to the AlphaServe r 1000A R ack mount Owner's Guide for instructions on locking the
Record the key number for each cabinet door and each CPU. Store this
information in a safe place; you will need the information if replacement is
necessary.
This section provides a brief description of each major component of the AlphaServer IP
Platform, and lists the required and optional hardware. Contact your Compaq sales
representative for the current supported options and ordering information.
1.4.1 AlphaServer 1000A System
This section describes the AlphaServer 1000A system. It also lists the required hardware for
this system.
1.4.1.1 Overview
The AlphaServer 1000A system is an Alpha uniprocessor server running the Tru64 UNIX
operating system. A single IP cabinet can support up to two AlphaServer 1000A systems. The
AlphaServer 1000A system drives all functions within the IP Platform, including voice
processing, management, and communications. In addition, application, service, and other
layered software run on an Al phaServe r 1000A system. The AlphaServer 1000A offers high
reliability features such as ECC memory and ECC cache.
The AlphaServer 1000A system includes:
•
9 expansion slots: 7 PCI slots and 2 EISA slots
•
256 MB memory, expandable to 1 GB memory
•
Integrated Fast-Wide Single-Ended SCSI-2 controller (supports wide and narrow drives)
•
Multiple drive bays supporting a 1.44 MB floppy diskette, RRD4 x-xx CD-ROM, 1
available removable media drive bay, and 3 3.5-inch hard disks
•
2 serial ports (9-pin) and one enhanced bi-directional parallel port (25-pin)
For additional information on the AlphaServer 1000A system features and capabilities, see
the AlphaServer 1000A Rackmount Owner's Guide.
1–6
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1.4.1.2 AlphaServer 1000A Required Hardware
Table 1-1 lists the requi re d hardware for t he Al phaSe rve r 1000A system. Refer to the
DIGITAL Systems and Options Catalog for descriptions of optional hardware.
Table 1-1: AlphaServer 1000A Required Hardware
Part NumberDescriptionSimplexDuplex
PB79D-RARM
PB7MA-CE256 MB memory12
2T-VC220-IPAT bus expansion kit (EISA/ISA module) Access
2T-IPCON-AAAlarm control module12
RZ1CB-BS4.3 GB SCSI hard disk drive
RRD47-AA32 X CD-ROM drive12
PBXTL-DA8.0 GB SCSI 4 mm DAT drive12
AlphaServer
System, includes RX23 floppy dri ve
I/O transmitter and receiver modules and 2-meter
cable
Note:
Each
simplex and duplex configurat i ons ar e
preconfigured with one wide disk for sys tem f i l es
and data
1000A 5/500
AlphaServer
Tru64 UNIX
1000A system in the
12
12
12
Product Overview
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–7
Product Overview
1.4.2 Modular Storage Shelf Subsystem (BA35x-Sx)
This section provides a brief description of the modular storage shelf subsystem.
1.4.2.1 Overview
The StorageWorks disk drive subsystem is a rackmount storage resource provided to solution
developers and service developers creating applications on the AlphaServer IP Platform. The
shelves are contained in a separate chassis that provides a flexible capacity for adding and
hot-swapping disks.
The shelf is a self-contained unit with embedded backplane routing with two SCSI buses. It
can be configured for maximum connectivity (1 SCSI bus) or for maximum performance (2
SCSI buses).
Each StorageWorks modular storage shelf houses all the application storage disks in a
rackmount shelf. The following table lists the type of disks that can be used. For additional
information, see the BA350 Modular Storage Shelf Subsystem Configuration Guide.
1.4.2.2 Modular Storage Shelf Optional Hardware
Table 1-2 lists the hardware opt ions for the BA35x-Sx modula r storage shel f.
BA35x-SxRackmount
DS-RZ1CF-VW
DWZZB-VWFast, wide, different i al to s i ngle ended SCSI conver t er f or BA35x-Sx.
KZPSA-BBFast, wide, differential SCSI controller.
H885-AATri-link connector block.
H879-AASCSI termi nat or .
StorageWorks
Terminates SCSI bus at storage unit.
1.4.3 ISA Bus Expansion Chassis
This section describes the ISA bus expansion chassis.
1.4.3.1 Overview
The I-Bus 4820-2819 enclosure is used as a 20-slot ISA bus expansion chassis for the
AlphaServer 1000A system. The ISA bus expansion chassis contains all Dialogic voicemodules for its associated AlphaServer 1000A simplex and duplex systems. The I-Bus 48202819 enclosure contains an alarm sensor module which monitors temperature, dc power, and
cooling fan rotation. If any of these reach a point of failure, an alarm signal is sent to the
AlphaServer 1000A.
The ISA bus expansion chassis connects to the AlphaServer 1000A system as follows:
•
The ISA bus expansion chassis connects to the AlphaServer 1000A EISA bus by means
of the AT (ISA) bus expansion kit (PN 2T-VC220-IP).
StorageWorks
disks for BA35x enclosure. 4.3 GB disks.
in BA35x-Sx enclosure.
•
The ISA bus expansion chassis alarm inputs connect to the AlphaServer 1000A system
by means of a cable.
1–8
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1.4.3.2 ISA Bus Expansion Chassis Required and Optional Hardware
The ISA bus expansion chassis connects to the AlphaServer 1000A EISA bus by means of the
AT (ISA) bus expansion kit. The AT (ISA) bus expansion kit includes transmitter and
receiver modules and an interconnecting cable. The transmitter module resides in the
AlphaServer 1000A system, the receiver module resides in the ISA bus expansion chassis,
and the cable connects both modules.
Table 1-3 contains the required and optional hardware for the ISA bus expansion chassis. All
hardware listed in Table 1-3 can be ordered separately as spare parts.
Table 1-3: ISA Bus Expansion Chassis Required and Optional Hardware
Part NumberDescriptionSimplex Duplex
2T-VC221-IBISA bus expansion chassis12
2T-VC220-IP
2T-LDMOD-AA Load module12
2T-VC24T-xx
2T-VC211-xx
2T-VC212-xx
2T-VC320-xx
2T-VCLSI-xx
2T-VC121-xx
2T-VCFAX-xx
2T-VCF4E-xx
2T-VCVRP-xx
2T-VCVR4-xx
2T-VCVR2-xx
2T-VCDMX-xx
1
xx represents a two-lett er count r y code. Contact your Compaq sal es repr esent at i ve for add i t i onal
information.
2
Confirm that there are no cards in the ISA bus expansion chassis that use the Compressed Wri te
Timing (“zero-wait-state”) signal . The 2T-VC220-IP option does not servi ce thi s si gnal .
2
Access I/O AT bus expansion kit with 2-meter cabl e12
1
Dialogic D/240SC-T1, 24-channel, high-densi t y voiceprocessing and network-interface m odul e
1
Dialogic DTI/211, 24-channel, standar d- densi ty, T-1
network-interface module
1
Dialogic DTI/212, 30-channel, standar d- densi ty, E-1
network-interface module
1
Dialogic D/320SC, 32-channel, high-densi t y, voiceprocessing module
1
Dialogic LSI/120, 12-channel, st andar d-dens it y, anal og
loop-start network-inter face m odule
1
Dialogic D/121B, 12-channel, standard- densi t y, anal og
loop-start call- pr ocessi ng m odul e
1
Dialogic FAX/120, 12-channel, standard-dens i ty, FAX
processing module
1
Dialogic VFX/40E, 4-channel, low-density, anal og l oopstart call-proces si ng and 14, 400 b/s FAX processing
module
1
Dialogic VRP, 4/8/12/16-channel, st andar d-dens it y,
voice-recognition modul e
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–9
Product Overview
1.4.4 IP Power Controller Subsystem
This section briefly describes the IP power controller subsystem.
1.4.4.1 Overview
Each rackmount simplex and duplex IP Platform contains one or two power controllers
located in the bottom rack of the cabinet. Each controller provides power to one ISA bus
expansion chassis, one BA35x-Sx modular storage shel f, and one A lphaSe rve r 1000A
processor.
The AlphaServer IP Platform supports the following power controller models: 120 Vac, 250
Vac, or -48 Vdc. In addition, each processor and associated voice, storage, and
communication resource has its own individual power supply.
Refer to Appendix C for instructions on field wiring the -48 Vdc power controllers for power.
1.4.4.2 IP Power Controller Options
Table 1-4 lists the IP power controller options.
Table 1-4: IP Power Controller Options
Part NumberDescriptionSimplexDuplex
H7600-AA120 Vac power distributi on unit t hat provi des t en ( 10) ac
outlets, an attached power cord wit h an L5-30P plug, an
on/off circuit br eaker, and a power-on l i ght .
H7600-DB250 Vac power distributi on unit t hat provi des t welve (12)
IEC 320 ac outlets, an attached power cord with an I EC
309 plug, an on/off circui t breaker , and a power-on l i ght.
2T-48VDC-AA3 kW (N+1) -48 Vdc power inverter (-48 Vdc to 120 Vac
dual converter).
2T-48VDC-AB2 kW (N+1) -48 Vdc power inverter ( -48 Vdc to 120 Vac
dual converter).
12
12
01
10
1.4.5 Alarm Indicator Panel
The alarm indicator panel provides programmable visual and audible alarm indicators for the
IP Platform.
Table 1-5 lists the alarm indicator panel options.
Table 1-5: Alarm Indicator Panel Options
Part NumberDescriptionSimplexDuplex
2T-IPAIP-CAAlarm indicator panel for t he si m plex I P Pl atf orm s .1NA
2T-IPAIP-CBAlarm i ndi cat or panel f or t he dupl ex IP Pl at for ms .NA1
1–10
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1.4.6 External Hardware Options
Table 1-6 contains external hardware options.
Table 1-6: E xt ernal Hardware Options
Part NumberDescription
LA75S-AA
FR-B16AP-EG
(or equivalent)
VT520, VT525
(or equivalent)
LA75 Plus Companion
Personal computer for
Console terminal
Product Overview
printer for hardcopy syst em output
ServerWORKS
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–11
is some white text.
2
Installing the AlphaServer IP Platform Hardware
2.1 Introduction
This chapter includes the following topics:
•
Factory installed hardware
•
Site preparation
•
Hardware installation
2.2 Factory Installed Hardware
The AlphaServer Intelligent Peripheral (IP) Platform is configured and delivered according
to customer specification, with all hardware and software factory-installed. It is shipped ready
for connection to a customer's power source and network hardware.
Value-added Implementation Services (VIS) is available for the AlphaServer IP
Platform products. VIS provides high-quality integration, test verification, and
site installation; each process is performed by experienced service personnel. See
your Compaq sales representative for additional information.
Überprüfen Sie die Garantie Ihres Systems. Eventuell muß Ihr System, gemäß der
Garantie, vom Compaq-Kundendienst installiert werden, um Beschädigungen am
Gerät oder an der Software zu verhi nde rn.
Before you install the AlphaServer IP Platform, ensure that:
•
The installation site meets the specifications and environmental conditions listed in
Appendix A. For more information about planning and preparing the installation site for
a computer network for a free-standing system, refer to the Site EnvironmentalPreparation Guide. (PN EK-CSEPG-MA. Available by calling 1-800-344-4825.)
•
The power source is correct for your system, and is one of the following models: 120
Vac, 250 Vac, or -48 Vdc.
•
You have the correct number of T-1, E-1, or loop-start network connections and adequate
cabling.
The T-1 cable le ngt h from t he net work to t he A l phaServe r IP P lat f orm cannot
exceed 199.6 m (655 ft) without a repeater. Do not use a repeater for cable
lengths less than 199.6 m (655 ft).
The system is located in an area that provides 61 cm (24 in.) clearance from the rear of
the cabinet, and 76.2 cm (30 in.) from the front of the cabinet for ventilation and
servicing.
•
Personnel are appropriately trained in the installation and operation of this system.
2–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
2.4 Hardware Installation
This section describes the installation and setup of the IP Platform.
Only a qualified service person should install the system. A qualified service
person is an individual who has the technical training and experience to be
aware of the:
•
Hazards to which they are exposed in performing a task
•
Measures to minimize the danger to themselves or other persons
A qualified service person need not be a Compaq service representative.
Das System darf nur von qualifizierten Fachleuten installiert werden.
Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult
sind und über die nötige E r f a hr ung verfügen, um :
•
die Gef a hr e n zu erkenne n, denen sie be i der Ausführung de r Arbeit
ausgesetzt sein könnten
•
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst
und für andere Personen zu ergreifen.
Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des CompaqKundendienstes.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
2–3
Installing the AlphaServer IP Platform Hardware
2.4.1 Installing the IP Platform
After you have verified the installation site, install the AlphaServer IP Platform by
performing the following steps:
1. Position the cabinet, allowing a 60.96 cm (24 in) minimum rear aisle clearance and a
76.2 cm (30 in) minimum front aisle clearance.
2. Level the cabinet using the four-point leveling hardware.
3. If a -48 Vdc power inverter is installed in the platform, bolt the AlphaServer IP Platform
to the floor at the cabinet base using the front and rear shipping brackets (and optionally
at the top, using the appropriate central office conforming hardware). Local codes may
prohibit bolting the cabinet to the floor if H7600 power distribution units are installed.
4. Connect to the network hardware (see Section 2.4.1.1).
5. Connect the IP Platform to the appropriate power supply. See Appendix C for
instructions on wiring the -48 Vdc controllers if your system has them installed. Refer to
the power ratings listed on the cabinet part number label located at the rear of the cabinet
above the door.
6. Verify the hardware setup. Before you turn on the system, check to ensure that the IP
Platform is properly secured, and the power controller and network hardware connections
are correct.
7. Power up the system. See Section 3.2.
2.4.1.1 Connecting the Network Hardware
This section describes how to install Dialogic's voice-processing, voice-recognition, and
network-interface T-1, E-1, and loop-start modules to the building's network hardware.
Refer to the Dialogic Network Hardware Reference and the Dialogic Voice HardwareReference for diagrams of the Dialogic modules and for additional information on the
Dialogic modules. All Dialogic modules are installed in the ISA bus expansion chassis.
2–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Installing the AlphaServer IP Platform Hardware
2.4.1.1.1 Connecting Dialogic D/240SC-T1 and DTI/211 T-1 Modules
On the rear bracket of the D/240SC-T1 and DTI/211 network modules is an RJ-48C jack for
connecting to the T-1 network. The cabling between this jack and the CSU or other DSX-1
equipment should be 4-pair telephone line or equivalent. The network interface module of the
cable should consist of an RJ-48C plug. The user is responsible for supplying an appropriate
cable for these connections. The pin designations for the network interface module cable end
for D/240SC-T1 modules are specified in Table 2-1.
Table 2-1: T-1 to D/240SC- T1 Pin Designations
SignalPin(s)
Receive ring: input to network int er face m odul e1
Receive tip: input to network int er f ace modul e2
No connection3, 6
Transmit ring: output from network interface module5
Transmit tip: output from network interface module4
Optional shield7, 8
The pin designations for the network interface module cable end for DTI/211 T-1 modules
are specified in Table 2-2.
Table 2-2: T1 to DTI/211 Pin Designations
SignalPin(s)
Receive ring: input to network int er face m odul e1
Receive tip: input to network int er f ace modul e2
No connection3, 6
Transmit ring: output from network interface module4
Transmit tip: output from network interface module5
Optional shield7, 8
Refer to the Dialogic Network Hardware Reference for additional information on DTI/211 T1 modules. Refer to the Dialogic Voice Hardware Reference for additional information on
D/240SC-T1 modules.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
The Dialogic DTI/212 E-1 m odul es com e in 75-ohm a nd 120-ohm ve rsions. If you ha ve a
DTI/212 120-ohm module, see Section 2.4.1.1.3. Refer to the Dialogic Net work HardwareReference for additional information on DTI/212 E-1 modules.
On the rear bracket of the DTI/212 75-ohm module are two BNC-type jacks for connecting to
the external E-1 network. The cabling between these jacks and the external E-1 network
should be 75-ohm coaxial. The DTI/212 end of the cable should consist of a BNC-type male
connector. The user is responsible for supplying an appropriate cable for these connections.
The pin designations for the DTI/ 212 75-ohm ca bl e ends are gi ve n in T a ble 2-3.
Table 2-3: E - 1 to DTI/ 212 75- Ohm Pin Designations
SignalJack/Pin
Transmit data: output from DTI/212 (tip)J201A center
Transmit data: output from DTI/212 (ring)J201A shield
Receive data: input to DTI/212 (ti p)J201B center
Receive data: input to DTI/212 (ri ng)J201B shield
To cable the DTI/212 75-ohm m odule t o the E -1 net work, fol l ow these ste ps:
1. Attach the appropriate end of the E-1 to DTI/212 (receive) cable to jack J201B on the
rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and
lock by turning a quarter-t urn c loc kwise.
2. Attach the appropriate end of the DTI/212 to E-1 (transmit) cable to jack J201A on the
rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and
lock by turning a quarter-t urn c loc kwise.
On the rear bracket of the DTI/212 120-ohm module is an RJ-48C jack for connecting to the
external E-1 network. The cabling between this jack and the CSU should be 120-ohm twisted
pair or equivalent. The DTI/212 120-ohm end of the cable should consist of an RJ-48C plug.
The user is responsible for supplying an appropriate cable for these connections. The pin
designations for the DTI/212 120-ohm ca bl e e nds are gi ven i n T a ble 2-4.
Table 2-4: E - 1 to DTI/ 212 120- Ohm Pin Designations
SignalPin(s)
Receive ring: input to the DTI/212 120-ohm m odul e1
Receive tip: input to the DTI/212 120-ohm m odul e2
No connection3, 6
Transmit ring: output from the DTI/212 120-ohm module5
Transmit tip: output from the DTI/212 120-ohm module4
Optional shield7, 8
2–6
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Installing the AlphaServer IP Platform Hardware
To cable the DTI/212 120-ohm m odule t o the E -1 net work, fol l ow these ste ps:
1. Align the RJ-48C connector at the DTI/212 120-ohm module end of the E-1 to DTI/212
120-ohm cable with jack J201 on the rear bracket of the DTI/212 module.
2. Gently push the cable connector into the RJ-48C jack until it snaps into place.
The customer is responsible for supplying additional cabling to connect the LSI/120 network
interface module to the telephone company lines.
Refer to the Dialogic Network Hardware Reference for additional information on LSI/120
modules.
You can choose from the following connection options:
•
Use Compaq's BC22F cable. This cable has a DB-25 connector on one end (to connect to
the LSI/120), and a 50-pin connector on the other end that provides 12 tip and ring pin
pairs that are compatible with a standard RJ-21X USOC jack.
•
Use Dialogic's SA/120 RJ-11 assembly. This assembly accepts the 50-pin male connector
from the SA/120 RJ-21 cable and terminates with 12 RJ-11 connectors. This cable allows
you to connect individual subscriber lines to the LSI/120.
The pin-out specifications in Table 2-5 and Table 2-6 are for connector P3 on the LSI/120.
This cable uses a 25-pin female DB-25 connector (Amphenol part number 745495-2 or
equivalent) on the LSI/120 end, and a 50-pin jack (Amphenol part number 157-72500-3 or
equivalent) that is compatible with an RJ-21X USOC jack.
Table 2-5: LSI/120 Loop-Start 25-Pin Designations
TIP 8114RING 12
RING 8215TIP 12
TIP 9316RING 11
RING 9417TIP 11
TIP 4518RING 10
RING 4619TIP 10
TIP 7720TIP 3
RING 7821RING 3
TIP 6922RING 1
RING 61023TIP 1
TIP 51124RING 2
RING 51225TIP 2
RESERVED1 3
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
2–7
Installing the AlphaServer IP Platform Hardware
Table 2-6: LSI/120 Loop-Start 50-Pin Designations
RING 1126TIP 1
RING 2227TIP 2
RING 3328TIP 3
RING 4429TIP 4
RING 5530TIP 5
RING 6631TIP 6
RING 7732TIP 7
RING 8833TIP 8
RING 9934TIP 9
RING 101035TIP 10
RING 1111 36TIP 11
RING 121237TIP 12
RING NC1338TIP NC
RING NC1439TIP NC
RING NC1540TIP NC
RING NC1641TIP NC
RING NC1742TIP NC
RING NC1843TIP NC
RING NC1944TIP NC
RING NC2045TIP NC
RING NC2146TIP NC
RING NC2247TIP NC
RING NC2348TIP NC
RING NC2449TIP NC
RING NC2550TIP NC
2.4.1.2 IP Power Controller
The
AlphaServer IP Platform
supports the following power controller models: 120 Vac, 250
Vac, or -48 Vdc. Each simplex and duplex rackmount system has one or two power
controllers located in the bottom of the cabinet. Each controller supports one BA35x-Sx, ISA
bus expansion chassis, and an
AlphaServer
1000A system.
Instructions for wiring the -48 Vdc power controllers to the building's power source are
included in Appendix C.
2.4.1.3 User Alarms
If the
AlphaServer IP Platform
does not use the -48 Vdc power controller, the user can
connect up to three external TTL signal alarms to the 8-pin MJ connector on the alarm
control module. Refer to Appendix B for a pinout of this connector and the
Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide
configuring these alarms.
2–8
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Intelligent
for information on
2.4.2 Locking Your System
The AlphaServer IP Platform is protected by a key lock in the front and rear door panels.
Duplicate interchangeable sets of keys are provided for both front and rear locks.
The AlphaServer 1000A system also comes with a set of keys for each CPU.
Store the keys in a safe place. Record the key number for each cabinet door and
each CPU. Store this information in a safe place; you will need the information if
replacement is necessary.
The AlphaServer 1000A Rackmount Owner's Guide contains additional information about the
AlphaServer 1000A locking procedure.
Installing the AlphaServer IP Platform Hardware
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
2–9
This is some white text.
3.1 Introduction
This chapter describes:
•
Turning on the AlphaServer IP P l atf orm
•
Basic operation of the IP Platform subsystem components
3.2 Turning on the AlphaServer IP Platform
After the AlphaServer IP Platform is properly secured, plugged in, and connected to the
building's network hardware, you are ready to power up the system. Refer to Appendix D and
Appendix E for the IP Platform diagrams to assist you in locating the system components.
3.2.1 Step I: Power Controller Circuit Breakers
Prior to turning on the circuit breakers for the 120 Vac or 250 Vac controllers, ensure that the
neon indicator is on, indicating that an ac voltage is present. The -48 Vdc controller does not
have an indicator for voltage; it should be connected to the -48 Vdc battery/power source
prior to turning on the circ ui t bre a kers.
3
Basic Operation
To start powering up the AlphaServer IP Platform, switch the circuit breakers at each power
controller (located in the rear of the cabinet) to the on position. The modular storage shelf
BA35x-Sx automatically powers up.
3.2.2 Step II: ISA Bus Expansion Chassis
To power up the ISA bus expansion chassis, press the On/Off switch on the front of the ISA
bus expansion chassis. The green ON/Off indicator on the front of the ISA bus expansion
chassis will illuminate.
3.2.3 Step III: AlphaServer 1000A System
Turn the AlphaServer 1000A system on by pressing the On/Off switch on the front of the
AlphaServer 1000A unit. The green On/Off indicator on the front of the system will
illuminate.
At this point in the IP Platform power on sequence, the alarm indicator panel should have the
green OK LED lit and the status display will contain either a “b” indicating discharged or
partially charged batteries, or it will be blank.
As described in the following sections, each subsystem within the IP Platform initiates its
own self-test at power-up. The following sections describe what a successful power-up of the
subsystem components looks like.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide 3–1
Basic Operation
3.3 Basic Operation of the IP Platform Subsystem Components
The following sections describe the basic operation of the IP Platform subsystem components.
3.3.1 Alarm Indicator Panel
The alarm indicator panel (see Figure 3-1) contains the following:
•
Visual indicators
•
Audible indicator
•
Battery backup logic
•
Keep-alive function
•
Dry contacts
Visual Indicators
The alarm indicator panel has three alarm LED indicators. These LED indicators are defined
as follows:
•
Critical (red LED)
•
Major (red LED)
•
Minor (amber LED)
The LED for a particular level of severity will be lit as long as at least one event of that level
is active. Multiple LEDs may be simultaneously lit.
The alarm indicator panel has two other indicators used for status information. These are the
following:
•
Status display
•
Alarm indicator panel OK LED (green)
The status display is used to output status as a result of the diagnostic testing and to display
other status information as shown in the following tables.
The OK LED is lit after a successful reset and will remain lit until either an unsuccessful reset
or a loss of battery power occurs.
Refer to the Intelligent Peripheral Fault Manager For Tru64 UNIX Installation and User'sGuide for additional information on the alarm indicator panel and fault management.
The alarm indicator panel should not be permanently removed without deconfiguring it in the Intelligent peripheral Fault Manager (IPFM) config file.
Refer to the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Basic Operation
The following table describes the normal conditions of the alarm indicator panel when the
AlphaServer 1000A is powered on and the Intelligent Peripheral Fault Manager (IPFM)
software is running.
batteries
Software DiagnosticsOnOff“d”Off
Softwa re TestOnOff“t”Off
If the AlphaServer 1000A system looses power while the IPFM software is running, the
following table describes the possible conditions of the alarm indicator panel.
Fully discharged batteri es OffOffblankOff
Fully charged batteriesOnOn“p”On
Partially charged
batteries
OnOff“b”Off
OnOn“b”On
Figure 3-1 shows a front and rear view of the alarm indicator panel.
Figure 3-1: Alarm Indicator Panel (Front and Rear View)
Front View
CRITICAL
MAJOR
MINOR
_
Battery
_
Battery
A
L P H A S E R V E R
+
+
AUDIBLE
DISABLE
I P F
A U L T M A N A G E R
_
Battery
_
Battery
STATUS
OK
+
_
Battery
+
+
J8
J3
J5
J4
J2
_
J1
Rear View
J6
J14
J15
Battery
_
Battery
+
+
ML014057
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
3–3
Basic Operation
Audible Indicator
The audible indicator has three distinct sounds associated with the three levels of alarming.
This indicator is controlled by software through the alarm control module or by a disable
switch on the alarm indicator panel itself. The audible indicator will sound at the level of the
most severe alarmed event that is currently active. No more than one level of audible alarm
can be enabled at any one time. The disable switch turns off the current audible alarm until a
new event occurs that is of equal or greater severity level than the highest level alarm
currently active, or until the event causing the audible alarm is cleared and another alarmed
event is pending.
The three audible alarm levels are defined as follows:
•
Critical is two beeps, the first separated from the second by 0.5 seconds or less. This
double beep pattern is repeated every 1.5 seconds.
•
Major is one beep every 1.5 sec onds.
•
Minor is one beep every 5 seconds.
Battery Backup Logic
The battery backup logic is designed to keep the current indicator status functioning for the
life of the batteries (approximately 60 to 120 minutes) in the event of a power failure. It
provides an indication if the batteries are low by displaying a “b” in the status display.
Keep-Alive Function
The alarm indicator panel houses a timer that is used to ensure that the CPU controlling it is
still running. The function is enabled by software, which starts a timer. As long as software
resets the timer before expiration, a “rotating bar” is displayed in the status display, otherwise
a minor alarm is generated. A minor alarm will also be generated if power to the alarm
indicator panel is lost and a “p” will be displayed in the status display.
3.3.1.1 Replacing Batteries in the Alarm Indicator Panel
The alarm indicator panel contains seven 1.2 V, 600 mA, NICD type AA rechargeable
batteries that provide battery backup for providing alarm information when the system loses
power or is turned off. When an alarm indicator panel continuously indicates a low battery
condition in the absence of a power loss, the batteries should be replaced. These batteries
should be replaced only with the same type batteries (PN 12-41230-04) or the equivalent
batteries.
Perform the following procedure to replace the batteries in an alarm indicator panel:
1. Power down the AlphaServer 1000A system.
2. At the front of the cabinet, remove the four screws that secure the alarm indicator panel
frame to the front rails.
3. Disconnect the miniature 26-pin cable(s) from the connector(s) on the rear of the alarm
indicator panel(s).
4. On the rear of the alarm indicator panel that indicates a low battery condition, remove
the two screws that secure the miniature 26-pin connector to the rear cover.
3–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Basic Operation
5. Remove the three scre ws from the top e dge and t he thre e screws from the bot tom e dge of
the alarm indicator panel frame that secure the alarm indicator panel rear cover.
6. Remove the alarm indicator panel rear cover.
7. Remove the seven batteries from the battery holders.
Replace the batteries with the same type (PN 12-41230-04) or an equivalent
type recommended by the battery manufacturer. Danger of explosion exists if
batteries are incorrectly replaced. Discard used batteries according to
battery manufacturer instructions. Be certain to follow any applicable
country, state, or local statutes for proper battery disposal.
Ersetzen Sie die Batterien nur durch Batterien des gleichen (PN 12-41230-04)
oder ähnlichen Typs, so wie es vom Hersteller empfohlen wird. Wenn Sie die
Batterien falsch auswechseln, besteht Explosionsgefahr. Folgen Sie bei der
Beseitigung der alten Batterien sowohl den Anweisungen des
Batterieherstellers als auch den jeweiligen länderspezifischen bzw. lokalen
Vorschriften zur richtigen Batteriebeseitigung.
8. Observing proper polarity, install the seven new batteries in the battery holders.
After installing the new batteries, reverse steps 1 through 6.
3.3.1.2 Dry Contacts
The dry contacts terminal connectors (see Figure 3-2) are located on the rear panel of the
alarm display unit. The four contacts on the input terminal block correspond to Critical,
Major, Minor, and Audio Shut-off alarm inputs. The output terminal block contacts
correspond to Critical, Major, Minor, and Audio Shut-off alarm outputs. These terminal
blocks can be used to connect remote alarm indicators. When an alarm condition occurs, the
corresponding relay is closed to connect a voltage on the input terminal to a remote alarming
device on the output terminal. See Table 3-1 for the dry contact relay functional specification.
Additionally, an audible alarm can be remotely disabled by connecting to the Shut-off Alarm
contacts. Refer to Appendix A for the dry contact electrical specifications.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
3–5
Basic Operation
Figure 3-2: Dry Contact Terminal Connectors
AB
12345678910
LJ-06572.AI7
AInput Term i nal BlockBOutput Terminal Block
➊Ext. Critical Alarm➏Critical Alarm
➋Ext. Major Alarm➐Major Alarm
➌Ext. Minor Alarm➑Minor Alarm
➍Ext. Shut-off Alarm➒Shut-off Alarm
➎Ground➓Ground
console displays test codes and initialization messages. When the startup procedure is
complete, the following occurs:
The IP Platform console terminal emulation window displays the SRM console prompt
•
(>>>).
The operator control pa ne l on t he front of t he
•
message "Model 5/500."
Boot the
Tru64 UNIX
boot at each processor window. The
the
Tru64 UNIX
1000A system power is turned on, the screen on the IP Platform
system by typing boot at the console prompt. For duplex systems, type
prompt (#) appears.
Relay State
AlphaServer
AlphaServer
1000A system displays the
1000A system has booted successfully when
Refer to the
Tru64 UNIX
Refer to the
operation of the
3–6
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
DIGITAL UNIX I n st a l l a t ion Guide
system.
AlphaServer 1000A Rackmount Owner's Guide
AlphaServer
1000A system.
for installation instructions on booting a
, for additional information on the
3.3.3 Modular Storage Shelf BA35x-Sx Subsystem
There may be up to eight StorageWorks building blocks (SBBs) on each modular storage
shelf BA35x-Sx subsystem. The StorageWorks Buildi ng Bl ock (SBB) slots are num bere d 0
through 7 from right to left with the power supply SBB in slot 7. On the IP simplex system,
the storage SBBs are in slots 0-6. On the duplex system, the available storage SBBs are in
slots 0-5.
After power is supplied to the IP Platform, observe the status LEDs for the following
successful indications:
•
On a power supply SBB, both green status LEDs should be on.
•
On a storage SBB, the green device activity LED is either on, flashing, or off. The amber
device fault LED is off.
Additional information on the following modular storage shelf BA35x-Sx components can be
found in the BA350 Modular Storage Shelf Subsystem User’s Guide.
Basic Operation
•
Component functions
•
Shelf status
•
Power unit status
•
Storage device status
•
StorageWorks building block SSB replacement procedures
•
Shelf replacement procedures
•
Power supplies
•
SCSI buses
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
3–7
Basic Operation
3.3.4 ISA Bus Expansion Chassis
The AlphaServer IP Platform supports a variety of voice/telephony options through the
addition of an ISA bus expansion chassis. The ISA bus expansion cha ssis is configured wit h a
20-slot ISA backplane. The EISA to ISA bridge uses one slot and the remaining 19 slots are
available for telephony options. The ISA bus expansion chassis has the following
characteristics:
•
Conforms to ISA bus specifications
•
Contains an ON/Off power switch for removing power for servicing
•
Contains an alarm sensor module for monitoring
Chassis temperature
–
Chassis voltage
–
Cooling fan rotation
–
•
Connector for communication with the alarm control module installed in the AlphaServer
1000A system
•
Slide mounted to allow front access to all modules
•
430 W power supply to support maximum output voltages (to voice boards) and
capacities as shown in the following table.
VoltageAmps*
570
-51.0
125.0
-121.0
* Provided that the maxim um
output power does not exceed the
power supply rating.
•
Contains a load module to provide minimum power supply pre-load (4.2 A @ +5 V).
This module may be rem ove d from t he ISA bus expansion chassis when the m i nim um
power supply pre-load can be attained with the installed telephony options.
Each simplex system contains one ISA bus expansion chassis. Each duplex system contains
two ISA bus expansion chassis. A connector on the alarm control module is dedicated to
bringing in physical alarm signals from the ISA bus expansion chassis. Any of the alarm
events listed above cause the alarm subsystem to generate an interrupt to the system software
in order to update the alarm database and also send alarm signals to the alarm indicator panel
for display.
3–8
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Reconfiguring the AlphaServer IP Platform
4.1 Introduction
In order to upgrade the AlphaSe rve r IP Pl at form or replace defective parts, you need to
remove and install components within the IP Platform. These components are within the
individual AlphaSe rve r 1000A system, ISA bus expansion chassis, and modular storage shelf
BA35x-Sx subsystems. After you change any IP Platform component, you may want to verify
or modify the system configuration.
This chapter lists the components of the IP Platform subsystem that may need to be removed
or installed, and the procedure for viewing and modifying the subsystem configurations using
the IP Platform console terminal SRM commands.
Before you attempt to install third-party devices inside your system unit, check with the thirdparty vendor to ensure that your system hardware and operating system software support the
device.
Static electricity can damage electronic components. Use the antistatic wriststrap
located in the inside rear cabinet door pocket. Additionally, use an antistatic mat
when you handle internal c om ponent s.
Elektrostatische Entladungen könnten elektronische Komponenten beschädigen.
Tragen Sie deshalb das Antistatikarmband, das sich in der Tasche an der
Innenseite der hinteren Gehäuseklappe befindet. Außerdem sollten Sie bei der
Berührung von internen Komponenten eine Antistatikmatte benutzen.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide 4–1
Reconfiguring the AlphaServer IP Platform
4.2 AlphaServer 1000A System Configurations
The components of the Al phaSe rver 1000A system that may need to be replaced or upgraded
include:
•
Storage devices (DAT tape drive, hard disk drive, floppy drive, CD-ROM drive)
•
Memory modules
•
CPU motherboard
EISA modules
–
DExxx Ethernet controller *
–
Access I/O transmitter module (AT bus expansion kit) *
–
PCI modules
–
* KZPSA-BB SCSI controller (qty=2) (optional)
* Alarm control module
•
Power supply
The KZPSA-BB PCI-to-SCSI adapter comes with its own utilities diskette that can be used to
modify the adapter parameters. See the StorageWorks KZPSA PCI-to-SCSI Storage AdapterUser's Guide for a complete description of the adapter.
After modifying the above c om ponent s, a nd be fore you boot t he Tru64 UNIX operating
system, you can use the SRM console commands from the IP Platform console terminal to
examine the system configurations of these components, and make modifications if
necessary.
The EISA Configuration Utility (ECU) must be run whenever you add, remove, or move a n
EISA or ISA card within the AlphaServer 1000A system. The ECU is a menu-based utility
run from the SRM console that provides online help to guide you through the configuration
process.
Table 4-1 describes some of the basic SRM console commands used to verify system
configurations on systems running the Tru64 UNIX operating system.
Table 4-1: SRM Console Configuration Commands
CommandDescription
show config
show device
show memory
set
and
show
Displays the buses on the system and the devi ces f ound on t hose bus es.
Displays the devices and controll er s on t he syst em .
Displays the main memory configuration.
Sets and displays the environm ent var iabl es .
Refer to the AlphaServe r 1000A R ack mount Owner's Guide for complete instructions on
using the ECU and SRM console commands, or t ype
The ISA bus expansion chassis provides a flexible capacity for adding voice modules of
varying types based on products from Dialogic. See Section 1.4 for a complete list of
available ISA bus expansion options.
Once the Dialogic voice modules are physically installed, you need to configure them by
running the ECU from the IP Platform console terminal. Use the ECU to register the modules
with the system hardware, and to reserve the addresses and interrupt request levels (IRQs)
that are to be used by the modules. The ECU attempts to identify and resolve resource
conflicts. The ECU may also be used to determine unused I/O ports, shared memory address,
and IRQs.
In addition to the Dialogic voice modules, other components within the ISA bus expansion
chassis include the:
•
Fan
•
Power supply
•
Alarm sensor module
•
Access I/O transceiver (AT bus expansion kit)
For a complete description of installing and configuring the voice-option modules, refer to the
Dialogic documentation shipped with the option.
For a complete description of removing and replacing the fan or power supply, refer to the I-Bus 4820 User Manual that is shipped with your system.
Refer to Section 4.3.1 and Section 4.3.2 for complete descriptions of removing and replacing
the alarm sensor module and the AT bus expansion kit.
4.3.1 Removing and Replacing the Alarm Sensor Module
The alarm sensor module is mounted in the drive bay area of the ISA bus expansion chassis.
The 2T-IPSEN-AA alarm sensor module kit consists of an alarm sensor module, a cable to
connect the alarm sensor module to the rear bulkhead, and a cable to connect the rear
bulkhead to the alarm control module in the AlphaServer 1000A.
Perform the following procedure to remove the alarm sensor module:
1. Remove power from the ISA bus expansion chassis by pressing the On/Off switch on the
front of the ISA bus expansion chassis.
2. Remove the screws that secure the ISA bus expansion chassis to the front rails and extend
the ISA bus expansion chassis on the slides.
3. Remove the screws that secure t he t op c over a nd re move t he t op c over from t he ISA bus
expansion chassis.
4. Disconnect the 6-pin bulkhead cable, the 4-pin power supply cable, and the 2-pin
temperature sensor cable from the alarm sensor module.
5. Remove the four screws that secure the alarm sensor module to the standoffs and remove
the alarm sensor module.
To replace the alarm sensor module, reverse steps 1 through 5 of the removal procedure.
4.3.2 Removing and Replacing the AT Bus Expansion Kit
The 2T-VC220-IP AT bus expansion kit consists of the transmit module installed in the
AlphaServer 1000A, the receive module installed in the ISA bus expansion chassis, and a 2meter cable that connects the two modules.
Perform the following procedure to remove the receive module from the ISA bus expansion
chassis:
1. Remove power from the ISA bus expansion chassis by pressing the On/Off switch on the
front of the ISA bus expansion chassis.
2. Remove the screws that secure the ISA bus expansion chassis to the front rails and extend
the ISA bus expansion chassis on the slides.
3. Remove the screws that secure t he t op c over a nd re move t he t op c over from t he ISA bus
expansion chassis.
4. Disconnect the cable from the receive module.
5. Remove the hold-down bar from ac ross the t op of the m odule s in t he ISA bus expansion
chassis.
6. Remove the screw that secures the receive module to the rear bulkhead of the ISA bus
expansion chassis.
7. Remove the receive module from the ISA bus expansion chassis.
To replace the receive module in the ISA bus expansion chassis, reverse steps 1 through 7 of
the removal procedure. Ensure that the jumpers on the new receive module are set to match
the jumpers on the receive module being replaced.
Once a device has been initialized on a SCSI bus with a specific device address,
moving the device to another bus or changing the device address can cause
problems.
Refer to the BA350 Modular Storage Shelf Subsystem User’s Guide for specific instructions
on adding and removing StorageWorks components, and setting the correct device addresses.
The alarm indicator panel provides programmable visual and audible alarm indicators for the
AlphaServer IP Platform. The alarm indicator panel consists of a metal frame, graphics
panel(s), and alarm indicator module(s). A cable connects the alarm indicator module to the
alarm control module that is installed on the AlphaServer 1000A PCI bus.
4.5.1 Removing and Replacing the Alarm Indicator Module
The alarm indicator module is mounted inside the alarm indicator panel.
Perform the following procedure to replace an alarm indicator module:
1. Power down the AlphaServer 1000A system.
2. At the front of the cabinet, remove the four screws that secure the alarm indicator panel
frame to the front rails.
3. Disconnect the miniature 26-pin cable(s) from the connector(s) on the rear of the alarm
indicator panel(s).
4. If attached, disconnect any cables connected to the dry contact terminal blocks.
5. On the rear of the alarm indicator panel that contains the alarm indicator module to be
replaced, remove the two screws that secure the miniature 26-pin connector to the rear
cover.
6. Remove the three scre ws from the top e dge and t he thre e screws from the bot tom e dge of
the alarm indicator panel frame that secure the alarm indicator panel rear cover.
7. Remove the alarm indicator panel rear cover.
8. Remove the four screws that secure the alarm indicator module to the alarm indicator
panel frame.
To replace the alarm indicator module, reverse steps 1 through 8 of the removal procedure.
The alarm indicator panel should not be permanently removed without deconfiguring it in the Intelligent Peripheral Fault Manager (IPFM) config file.
Refer to the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation
This chapter describes procedures for resolving problems with the components of the
AlphaServer Intelligent Peripheral (IP) Platform. If the subsystem troubleshooting is
discussed in another manual, a reference is provided to that documentation.
Before servicing the system, be aware of any service agreement that exists for your system.
The agreement helps determine the level of maintenance for self-maintenance customers.
To correct a problem, locate the troubleshooting section for that component and refer to the
appropriate documentation. If you cannot correct the problem, report it to your service
representative.
Only a qualified service person should install the system. A qualified service
person is an individual who has the technical training and experience to be
aware of the:
•
Hazards to which they are exposed in performing a task
•
Measures to minimize the danger to themselves or other persons
A qualified service person need not be a Compaq service representative.
Das System darf nur von qualifizierten Fachleuten installiert werden.
Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult
sind und über die nötige E r f a hr ung verfügen, um :
•
die Gef a hr e n zu erkenne n, denen sie be i der Ausführung de r Arbeit
ausgesetzt sein könnten
•
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst
und für andere Personen zu ergreifen.
Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des CompaqKundendienstes.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide 5–1
System Troubleshooting
5.2 AlphaServer 1000A Subsystem
The AlphaServer 1000A Rackmount Owner's Guide provides the instructions on completing
the following tasks or resolving these particular problems:
•
Confirming that EISA modules or memory modules are properly configured
•
Running a diagnostic test of the entire system, showing its status, or terminating the
testing
•
Checking the startup displa y when you t urn on the system
•
What to do if:
−
The power supply has shut down
−
Startup tests do not complete
−
The system cannot boot the operating system
−
The operating system reports errors, is hung, or crashes
−
The system cannot access a mass storage device
−
Storage devices are missing from the show device display
−
The system indicates network problems, an EISA module is not configured,
or a PCI module is unseen by the system
−
The monitor or the te rm ina l is not working
−
The keyboard and mouse are not working
−
The system repeatedly shuts down after 10 seconds
−
The system does not see or cannot access RAID drives
−
The Flash ROM is corrupted and the system cannot access console mode
5.3 Alarm Indicator Panel
The alarm indicator panel (see Figure 3-1) uses visual and audio alarm indicators to display
the status of the IP Platform, including the ISA bus expansion chassis and the -48 Vdc power
inverter or user alarm inputs. The alarm indicator panel displays alarms as long as it can
communicate with the alarm control module in the AlphaServer 1000A, or until its backup
batteries become fully discharged.
Refer to Section 3.3.1 for a description of the alarm indicator panel alarms and status
displays. Refer to Section 3.3.1.1 for the procedure for replacing the batteries in the alarm
indicator panel.
5–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
5.4 ISA Bus Expansion Chassis
The ISA bus expansion chassis contains alarm sensors that detect fault conditions and send
the information to the alarm control module in the AlphaServer 1000A system chassis.
For a complete description of alarm sensor interaction with the IP Fault Manager software,
see the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide.
The status of the Dialogic voice modules is handled at the application level and not by the IP
Fault Manager software.
5.5 Modular Storage Shelf BA35x-Sx Subsystem
The modular storage shelf BA35x-Sx uses the LE Ds of its StorageWorks buil ding bl oc ks
(SBBs) to indicate problems within the power unit, storage devices, and StorageWorks shelf.
Depending upon the problem, these displays can be flashing, on, or off. The BA350 ModularStorage Shelf Subsystem User’s Guide provides instructions on how to interpret these
displays.
5.6 AlphaServer IP Power Controllers
If the power controllers do not function properly, perform the following steps:
System Troubleshooting
1. Prior to turning on the circuit breakers for the 120 Vac or 250 Vac controllers, ensure
that the neon indicator is on, indicating that an ac voltage is present. The -48 Vdc
controller does not have an indicator for voltage. It should be connected to the -48 Vdc
battery/power source prior to turning on the circuit breakers.
2. Check that the circuit breakers are on for each of the power controllers installed.
3. Refer to the DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac P owe r Inverte r Owner’s Guide
for more troubleshooting information on the -48 Vdc controller.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
5–3
is some white text.
AlphaServer IP Platform Specifications
A.1 Physical Dimensions
Table A-1 contains the physical dimensions for the AlphaServer Intelligent Peripheral (IP)
Platform.
Table A-1: Physical Dimensions
DimensionS pecification
Depth96.52 cm (38.0 in.) i ncl uding door s
Width55.88 cm (22.0 in.)
Height220.01 cm (86.62 in.) including cable tr ough
Height204.77 cm (80.62 in.) without cabl e t r ough
Weight385.56 kg (850 lbs) for ful l y l oaded duplex s yst em
Front aisle76.2 cm (30.0 in.) minimum cl earance
Rear aisle60.96 cm (24.0 in.) m i nim um cl earance
A
A.2 Electrical Specifications
Table A-2 contains the electrical specifications for each IP Platform power controller.
Table A-2: Electrical Specifications for Each Power Controller
SpecificationRange
Input voltage120 Vac or
Frequency (ac only) 50-60 Hz
Input current maxim um8.0 A at 120 Vac or
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide A–1
250 Vac or
-48 Vdc
4.0 A at 250 Vac or
50 A at -48 Vdc
AlphaServer IP Platform Specifications
A.3 System Environmental Specifications
Table A-3 contains the environmental specifications for the AlphaServer IP Platform.
Table A-3: Environmental Specifications
Operating/Storage Conditions
Temperature range10°C to 40°C (50°F to 104°F)
Barometric pressur e760 mm (29.92 in. Hg)
Relative humidity20% to 80% (noncondensing)
Minimum dew point2°C (36°F)
Maximum altitude2,438 m (8,000 ft)
Maximum wet bulb tem per at ure28°C (82°F)
Nonoperating Conditi ons
Temperature range-40°C to 66°C (-40°F to 151°F)
Relative humidity20% to 85% (noncondensing)
Maximum altitude4,877 m (16,000 ft)
1
The maximum allowable operati ng t em perat ur e above 2, 438 m ( 8, 000 ft ) i s r educed
1.8°C/1,000 m (1.0°F/ 1, 000 f t ) .
1
1
A–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
A.4 Dry Contact Specifications
Table A-4 contains the rating, input, and output specifications for the dry contact terminals.
Table A-4: Dry Contact Specifications
Material and Ratings
Contact materialGold-clad silver
Rating (resistive)
Maximum switching power60 W, 125 VA
Maximum switching vol t age220 Vdc, 250 Vac
Maximum switching cur r ent2 A DC, 2 A AC
Maximum carrying curr ent3 A DC, 3 A AC
Input Specifi cat i ons
TypeRelay coil
Rated input voltage5 Vdc nominal
Maximum input10 Vdc at 50 C
Pick-up voltage3.5 Vdc maximum
Drop-out voltage0.5 Vdc minimum
Coil resistance125 ohms, +/- 10%
Output Specifi cations
Contact rating (switching)
Voltage220 Vdc, 250 Vac (maximum)
Curren t2 A DC, 2 A AC (maxim u m )
UL/CSA0.6 A, 125 Vac
Coil rating200 mW typicall y
AlphaServer IP Platform Specifications
0.6 A, 110 Vdc
2.0 A, 30 Vdc
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
A–3
AlphaServer IP Platform Specifications
A.5 Central Office Compatibility
The AlphaServer IP Platform is intended for deployment in telecommunications central
office (CO) environments, and is compatible with some of Bellcore's Network EquipmentBuilding Systems (NEBS) specifications TR-NWT-000063.
Some of the central office compatible (conforming) hardware requirements supported by the
AlphaServer IP Platform are:
•
Simplex or duplex system housed within a single electronic equipment cabinet.
•
Cabinet of welded steel construction has locking front and rear doors, bolt-down
provisions at the cabinet ba se and t op (for use onl y when a -48 Vdc power i nve rte r i s
installed in the cabinet), four-wheel rugged castor base, four-point leveling, and cable
egress from top or bottom of the ca bi net .
•
Integral cable trough attached to the top-rear half of the cabinet, and for larger systems,
forms a continuous cable trough a l ong the c abi ne t t op-re ar.
•
120 Vac, 250 Vac, and -48 Vdc dual-feed power models are available for the duplex
system.
Floor loading is approximately 38.56 kg (85 lbs) per square foot according to
NEBS weight calculation rules. Maximum allowed is 52.16 kg (115 lbs) per
square foot.
Meets UL and other international safety specifications.
NEBS nonconforming features are:
•
Cabinet depth is 96.52 c m (38 i n. )
•
Printer and terminal are table-top mounted.
•
Fire testing not performed.
•
Convenience outlets not provided.
•
Earthquake testing for Z one s 2, 3, a nd 4 not pe rform ed.
The AlphaServer IP Platform simplex and duplex systems are contained within one single
bay 177.8 cm (70 in.) panel space cabinet (except for console terminal).
A–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
B.1 Alarm Input Wiring Diagram
The following diagram of the Intelligent Peripheral (IP) duplex platform displays the alarm
input wiring connections between the ISA bus expansion chassis, the AlphaServer 1000A
processors, and the alarm indicator panel.
Figure B-1: Alarm Input Wiring Diagram
2
3
5
4
6
B
Alarm Input Wiring
AlphaServer 1000A
1
ISA
7
➊
Alarm control module ins tal l ed i n
AlphaServer
the
➋
-48 Vdc power inverter
➌
D-sub 25-pin connector
➍
Inverter alarm cable
➎
Alarm indicator panel
8
1000A system
9
➏
Alarm indicator panel cable
➐
Alarm sensor module in t he ISA bus
expansion chassis
➑
D-sub 9-pin connector
➒
ISA bus expansion chassis alarm cabl e
ML014035
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide B–1
Alarm Input Wiring
B.2 Wiring User Alarm Inputs
This section provides information for wiring user TTL signal alarm inputs to the 8-pin MJ
connector on the alarm control module installed in the AlphaServer 1000A system.
Figure B-2 shows the 8-pin MJ connector on the alarm control module that is used for
connecting user alarm inputs.
Figure B-2: Alarm Control Module 8-Pin MJ Connector
1
Table B–1 provides a pinout listing of the pins on the alarm control module 8-pin MJ
connector. This table should be used to determine the correct wiring required for user alarm
inputs.
8
ML014036
Table B–1: Al arm Control M odule 8-Pin MJ Connector Pinout
Pin No.Signal
1Inverter Fail or user input 1 Retur n
2Inverter Fail or user input 1
3Inverter Minor or user i nput 2 Ret urn
4Inverter Minor or user i nput 2
5Inverter Major or user i nput 3 Ret urn
6Inverter Major or user i nput 3
7Not used
8Not used
B–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Field Wiring the -48 Vdc Power Inverter
C.1 Field Wiring the -48 Vdc Power Controllers
The following sections describe how to field wire the -48 Vdc power controllers.
The person(s) installing the system should be aware of the 1993 NEC
(National Electrical Code) requirements for data processing equipment
installation, Article 645, 645-2. Failure to follow these requirements could
result in personal injury and damage to the equipment.
Only a qualified service person should install the system. A qualified service
person is an individual who has the technical training and experience to be
aware of the:
•
Hazards to which they are exposed in performing a task
•
Measures to minimize the danger to themselves or other persons
A qualified service person need not be a Compaq service representative.
Die Personen, die das System installieren, sollten die Voraussetzungen de s
1993 NEC (National Electrical Code) zur Installation von
Datenverarbeitungsgeräten, Artikel 645, 645-2, kennen. Mi ßachtung dieser
Voraussetz ung e n kö nnte zu Personen- und Geräteschade n führen.
Das System darf nur von qualifizierten Fachleuten installiert werden.
Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult
sind und über die nötige E r f a hr ung verfügen, um :
•
die Gef a hr e n zu erkenne n, denen sie be i der Ausführung de r Arbeit
ausgesetzt sein könnten
•
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst
und für andere Personen zu ergreifen.
Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des CompaqKundendienstes.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide C–1
Field Wiring the -48 Vdc Power Inverter
C.1.1 Installing Suitable Field Wiring
The following subsections describe how to install suitable field wiring.
C.1.1.1 Field Wiring Recommendations
Table C–1 lists the field wiring recommendations for each side of the -48 Vdc power
controller. The -48 Vdc power controller has dual power feeds.
Table C–1: F ield Wi ring Recommendations for Each Power Feed
Input Power Requi r em e nt-48 Vdc Power Contr oller
Input voltage-48 Vdc
Input current50 A max
Inrush peak6 A max soft start limited
Recommended wire: Wire should be U/L recognized and CSA certified for 105°C (221°F),
with insulation rated for 600 Vac. Each of the 3-wire conductors should be a minimum of 6
AWG stranded.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Duplex System
D.1 Introduction
This appendix contains diagrams of the AlphaServer Intelligent Peripheral (IP) Platform
duplex, ac and dc, systems.
D
Diagrams
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide D–1
AlphaServer IP Platform Duplex System Diagrams
D.2 AlphaServer IP Platform Duplex AC System
This section contains the front, side, and rear views of the duplex ac system.
Figure D–1: IP Platform Duplex AC System Front and Side View
1
2
3
4
5
Front View
➊
Alarm indicator panels
➋
BA35x-Sx modular storage shelf (opt ional )
➌
ISA bus expansion chassis
Side View
➍ AlphaServer
➎
H7600 power controller
1000A
ML014018
D–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Duplex System Diagrams
Figure D–2: IP Platform Duplex AC System Rear View
1
2
3
4
5
Back View
ML014028
➊Alarm indicator panels➍ AlphaServer 1000A
➋BA35x-Sx modular storage shelf (opti onal )➎ H7600 power controll er
➌ISA bus expansion chassis
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
D–3
AlphaServer IP Platform Duplex System Diagrams
D.3 AlphaServer IP Platform Duplex DC System
This section contains the front, side, and rear views of the duplex dc system.
Figure D–3: IP Platform Duplex DC System Front and Side View
1
2
3
4
MX ALARM CARDMX ALARM CARD
AC POWERAC POWER
Front View
➊
Alarm indicator panels
➋
BA35x-Sx modular storage shelf (opt ional )
➌
ISA bus expansion chassis
5
Side View
➍ AlphaServer
➎
-48 Vdc power controller
1000A
ML014017
D–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Duplex System Diagrams
Figure D–4: IP Platform Du plex DC System Rear View
1
2
3
4
_
+
_
+
Back View
_
_
5
+
+
ML014027
➊Alarm indicator panels➍ AlphaServer 1000A
➋BA35x-Sx modular storage shelf (opti onal )➎ -48 Vdc power controll er
➌ISA bus expansion chassis
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
D–5
is some white text.
AlphaServer IP Platform Simplex System
E.1 Introduction
This appendix contains diagrams of the AlphaServer Intelligent Peripheral (IP) Platform
simplex, ac and dc, systems.
E
Diagrams
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide E- 1
AlphaServer IP Platform Simplex System Diagrams
E.2 AlphaServer IP Platform Simplex AC System
This section contains the front, side, and rear views of the simplex ac system.
Figure E–1: IP Platform Simplex AC System Front and Side View
1
2
3
4
5
Front View
➊
Alarm indicator panel
➋
BA35x-Sx modular storage shelf (opt ional )
➌
ISA bus expansion chassis
Side View
➍ AlphaServer
➎
H7600 power controller
1000A
ML014022
E-2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Simplex System Diagrams
Figure E–2: IP Platform Simplex AC System Rear View
1
2
3
4
5
Back View
ML014032
➊Alarm indicator panel➍ AlphaServer 1000A
➋BA35x-Sx modular storage shelf (opti onal )➎ H7600 power controll er
➌ISA bus expansion chassis
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
E-3
AlphaServer IP Platform Simplex System Diagrams
E.3 AlphaServer IP Platform Simplex DC System
This section contains the front, side, and rear views of the simplex dc system.
Figure E–3: IP Platform Simplex DC System Front and Side View
1
2
3
4
MX ALARM CARD
AC POWER
5
Front View
➊
Alarm indicator panel
➋
BA35x-Sx modular storage shelf (opt ional )
➌
ISA bus expansion chassis
Side View
➍ AlphaServer
➎
-48 Vdc power controller
1000A
ML014021
E-4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Simplex System Diagrams
Figure E–4: IP Platform Simplex DC System Rear View
1
2
3
4
_
+
_
+
Back View
_
_
5
+
+
ML014031
➊Alarm indicator panel➍ AlphaServer 1000A
➋BA35x-Sx modular storage shelf (opti onal )➎ -48 Vdc power controll er
➌ISA bus expansion chassis
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
E-5
is some white text.
Glossary
10Base-T Ethern et network
The IEEE standard 802.3-compliant Ethernet products used for local distribution of data.
These networking products characteristically use twisted-pair cable.
agent
A background task running on the object being managed. The agent responds to requests for
information by the network management station (NMS). The agent i s re sponsi bl e for
performing get and set operations, for generating the appropriate traps, and for controlling
access.
AlphaServer system
Compaq’s new generation of server systems based on the Alpha 64-bit computing
architecture.
ARC
Advanced RISC Computing (ARC) is the user interface to the console firmware for operating
systems that expect firmware compliance with the Windows NT Portable Boot Loader
Specification.
availability
The amount of scheduled time that a computing system provides application service during
the year. Availability is typically measured as a percentage of up time per year.
backbone
A core network (usually high speed) to which multiple local area networks (LANs) are
connected using bridges or routers and over which internetwork traffic can pass.
backplane
The main module (board or panel) that connects all of the modules in a computer system.
boot
Short for bootstrap. To load an operating system into memory.
boot device
The device from which the system bootstrap software is acquired.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide Gl ossar y- 1
Glossary
bus
A collection of many transmission lines or wires. The bus interconnects computer system
components, providing a communications path for addresses, data, and control information or
external terminals and systems in a communications network.
cache
A small, high-speed memory placed between slower main memory and the processor. A
cache increases effective memory transfer rates and processor speed. It contains copies of
data recently used by the processor and fetches several bytes of data from memory in
anticipation that the processor will access the next sequential series of bytes.
CD-ROM
Compact disc read-only memory. The optical removable media used in a compact disc
reader.
central pro cessing unit (CPU)
The unit of the computer that is responsible for interpreting and executing instructions.
command line interface
One of two interfaces in the AlphaServer operator interface. The command line interface
supports OpenVMS and Tru64 UNIX operating systems. It allows you to configure and boot
the operating system.
console mode
The state in which the system and the console terminal operate under the control of the
console program.
console subsystem
The subsystem that provides the user interface for a computer system when the operating
system is not running.
console terminal
The terminal connected to the console subsystem. It is used to start the system and to direct
activities between the user and the computer system.
CSU
Channel service unit. A device that terminates a digital channel on a customer's premises. It
contains certain line conditioning and equalization functions, and responds to loopback
commands sent from the central office.
daughterboard
A PC module that attaches to the component side of the host module.
diagnostic program
A program that finds and corrects problems with a computer system.
Glossary-2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Glossary
dry contacts
An electromagnetic device for remote or automatic control that is activated by variation in
conditions of an electric circuit and that in turn operates other devices (such as switches) in
the same or a different circuit.
DSX-1
Digital Signal Cross-connect Level 1. Any equipment that supports a set of parameters for
cross-connecting DS-1 (either T-1 or E-1) lines.
E-1
Another name given to the CEPT (Conference of European Postal and Telecommunications
Administrations) digital telephony format. E-1 is a digital transmission channel that carries
data at the rate of 2.048 Mb/s (DS-1 level).
ECC
Error correction code. The code and algorithms used by logic to facilitate error detection and
correction.
EISA bus
Extended Industry Standard Architecture bus. A 32-bit industry-standard I/O bus used
primarily in high-end PCs and servers.
EISA Configuration Utility (ECU)
A feature of the EISA bus that helps you select a conflict- free system configuration and
perform other system services. The ECU must be run whenever you change, add, or remove
an EISA or ISA controller.
environment variables
The global data structures that can be accessed from console mode. The setting of these data
structures determines how a system powers up, boots the operating system, and operates.
Ethernet
The IEEE 802.3 standard local area network.
firmware
The software code stored in hardware .
initialization
The sequence of steps that prepare the computer system to start. Initialization occurs after a
system has been powered up.
Interrup t request lines (IRQs)
The bus signals that connect an EISA or ISA module (for example, a disk controller) to the
system so that the module can get the system's attention by means of an interrupt.
ISA
Industry Standard Architecture. An 8-bit or 16-bit industry-standard I/O bus, widely used in
personal computer products. The E ISA bus is a superset of the ISA bus.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Glossary-3
Glossary
LAN
Local area network. A high-speed network that supports computers connected over limited
distances.
light-emitting diode (LED)
An indicator of status on an IP subsystem.
MAC (media access control) ad dress
A unique 48-bit binary number (usually represented as a 12-digit hexadecimal number)
encoded in a device's circuitry to identify it on a local area network.
Maintenance Operations Protocol (MOP) session
A logical connection using the Maintenance Operations Protocol (MOP).
mass storage devi ce
An input/output device on which data is stored. Typical mass storage devices include disks,
magnetic tapes, and CD-ROM.
module
A hardware or software component that is a self-contained system interacting with a larger
system. Hardware modules are often made to plug into a main system.
network
A collection of computers, terminals, and other devices together with the hardware and
software that enables them to exchange data and share resources over either short or long
distances.
network man agement station (NMS)
A PC or workstation equipped with an Ethernet, FDDI, or Token Ring network module an d
HUBwatch software that enables it to communicate with and manage network modules.
network modules
Modular devices that provide network connectivity or services that can be installed in a
DEChub backplane or used as standalone devices. Network modules include repeaters,
concentrators, bridges, brouters, access servers, switches, and SNMP agent s.
PCI
Peripheral component interconnect. An industry-standard expansion I/O bus that is the
preferred bus for high-performance I/O options. PCI is available in a 32-bit version and a 64bit version.
PCI-to-EISA bridge
The capability to transfer commonly available EISA and ISA options to the PCI bus.
protocol
A formal set of rules governing the format, timing, sequencing, and error control of
exchanged messages on a data network.
Glossary-4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Glossary
RAID
Redundant arrays of independent disks. A technique that organizes disk data to improve
performance and reliability. RAID has three attributes: it is a set of physical disks viewed by
the user as a single logical device; the user's data is distributed across the physical set of
drives in a defined manner; and redundant disk capacity is added so that the user's data can be
recovered even if a drive fails.
redundant
Pertaining to duplicate or extra computing components that protect a computing system from
failure.
reliability
The probability that a device or system will not fail to perform its intended functions during a specified
time.
repeater
A level 1 hardware device that restores signal amplitude, waveform, and timing of signals
before transmission to another ne t work segment .
SBB
StorageWorks building block. The basic bui ldi ng bl ock of t he StorageWorks product l ine .
Any device conforming to shelf mechanical and electrical standards installed in either a 3½inch or 5¼-inch carrier is considered to be an SBB, whether it be a storage device, a power
supply, or other device.
SCSI
Small Computer Systems Interface. An ANSI-standard interface for connecting disks and
other peripheral devices to computer systems. Some devices are supported under the SCSI-1
specification; others are supported under the SCSI-2 specification.
server
A network node or specialized device that provides and manages access to shared network
resources, such as hard disks, printers, a nd software.
SIMM
Single in-line mem ory m odule . A plug-i n modul e tha t has RAM chips on one side, a nd a n
edge connector that matches a socket on the system module.
Simple Network Management Protocol (SNMP)
A high-level, standards-based protocol for network management, usually used in TCP/IP
(Transmission Control Protocol/Inte rne t Protoc ol ) net works.
SNMP agent
An entity in a hardware device that executes SNMP request s.
SRM
The user interface to console firmware for operating systems that expect firmware
compliance with the Alpha System Reference Manual (SRM).
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Glossary-5
Glossary
StorageWorks
Compaq's modular storage subsystem (MSS), which i s the core technology of the Alpha
SCSI-2 mass storage solution. StorageWorks consists of a family of low-cost mass storage
products that can be configured to meet current and future storage needs.
system disk
The device on which the operating system resides.
T-1
The digital telephony format used in North America. T-1 is a digital transmission link
handling 24 voice conversations on two pairs of twisted wires.
Telnet
The TCP/IP standard protocol for remote terminal connections. Using Telnet, a user at one
site can connect to a timesharing system at another site as if the user's terminal is connected
directly to the remote machine.
terminal server
A module that allows a terminal to connect to a network node.
ThinWire
Ethernet cabling and technology used for local distribution of data communications.
ThinWire cabling is thinner than thick wire cabling.
Transmission Control Protocol (TCP)
The transport protocol offering a connection-oriented transport service in the Internet suite of
protocols.
workgroup
A configuration that consists of a relatively small number of devices attached to a LAN that
is isolated from the extended LAN backbone by a bridge or router.
Glossary-6
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide