Compaq EK-ASIP2-OG, D01 User Manual

AlphaServer Intelligent Peripheral Platform
Hardware Owner's Guide
Part Number: EK-ASIP2-OG. D01
May 1999
Compaq Computer Corpora ti on Houston, Texas
May 1999
COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HERE IN, NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE S RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIAL. T HIS INFORMATION IS PROVIDED “AS IS” AND COMPAQ COMPUTER CORPORATION DISCLAIMS ANY W ARRANT IE S , EXPRESS, IMPLIED OR STATUTORY AND EXPRESSLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR P URPOSE, GOOD TITLE AND AGAINST INFRINGEMENT.
This publication contains information protected by copyright. No part of this publicati on may be photocopied or reproduced in any form w ithout prior w r itten consent from Compaq Computer Corporation.
1999 Digital Equipment Corpor ation. All rights reser ved. Printe d in the U.S.A.
The software des cribed in this guide is furnished under a license agreement or nondi s closure agreement. The software may be used or copied only in accor dance with the terms of the agreement.
Compaq, the Compaq logo, and the Digital logo registered in United S tates Patent and Trademark Office.
AlphaServer, DIGITAL, Tru64 UNIX, DECevent, DEChub, H U Bwatch, LA75 Plus Companion, RX, RZ, StorageWorks , and ThinWir e , are trademarks of Compaq Computer Corporation.
The followi ng ar e third-party trademarks: Access I/O is a registered tr ademark of Access I/O C or poration. Amphenol is a regi s tered trademark of C anadian Imperial Bank of Commerce (N.Y. Agent). Dialogic is a registered tr ademark and D/121B, DT I /211, DTI/212, LSI/120, and PEB are t rademarks of Dialogic Corporation. Microsoft and Windows are registered trademarks and Windows NT is a trademark of Mi cr os oft Corporation. UNIX is a registered trademar k in the United States and other countr ies licensed exclus ively through X/Open C ompany Ltd.
All other trademarks and regist ered trademarks are t he pr operty of their r es pective owners.
S3757
FCC Notice: This equipment gener ates, uses, and may emi t radio frequency energy. The equipment has been t ype tested and found to comply with the l imits for a Class A digi tal device pursuant to Part 15 of FCC rules, which are designed to provide reasonable protection against such radio frequency interference.
Operation of t his equipment in a residential area may cause interference in w hich case the user at his ow n expens e w ill be required to take w hatever measures may be required to correct the interference.
Any modifications to this device - unless express ly approved by the manufacturer - can void the user’ s authority to operate this equipment under part 15 of the FCC rul es.
Note: Additional information on the need to interconnect the devi ce w ith shielded (dat a) cables or the need for s pecial devices, such as fer rite beads on cables, is required i f such means of interf e r ence s uppression was used in the qualification test for the device. This information will vary from device to device and needs to be obtained from the EMC group or pr oduct manager.
EMI Notice: This product complies with the f ollowing domesti c and international s tandards:
Domestic: FCC Part 15, Class A
Internati onal: CISPR22 (Europe EN 55022 Class A).
EC Notice:
Warning! This is a Class A product. In a domestic environment this product may cause radio interference in whi ch case the user may be requir e d to take adequate measures.
Achtung! Dieses ist ein Gerät der Funkstör gr e nzw ertklasse A. In Wohnbereichen können bei B e trieb dieses G erätes Rundfunkstörungen auftreten, i n w elchen Fällen der Benutzer für ent s pr echende Gegenmaßnahmen verantwortlich ist.
Attention! Ceci est un produi t de Classe A. D ans un environnement domestique, ce produit ri s que de créer des interférences radioélectriques, il appartiendra alors à l'utilisateur de prendre les mesures spécifiques appropriées.
ACOUSTICS:
Preliminary declared values per I SO 9296 and ISO 7779:
Sound Power Level
, B
L
wAd
Sound Pressure Level L
, dBA (Bystander Positions))
pAm
Idle 6.5 50 Operating 6.5 50
Current values for specific configurations are avai lable from Compaq repr es entatives. 1 B = 10 dBA.
This is some white text.

Table of Contents

Preface
1 Product Overview
1.1 Introduction.........................................................................................................................................1–1
1.2 IP Platform Overview..........................................................................................................................1–1
1.2.1 IP Simplex System.....................................................................................................................1–2
1.2.2 IP Duplex System......................................................................................................................1–2
1.2.3 Factory Installed Software .........................................................................................................1–3
1.3 System Features...................................................................................................................................1–4
1.3.1 User Interfaces...........................................................................................................................1–4
1.3.2 Alarm Subsystem .......................................................................................................................1–4
1.3.3 Maintainability ..........................................................................................................................1–4
1.3.4 Reliability..................................................................................................................................1–4
1.3.5 Upgrading................................................................................................................................. .1–5
1.3.6 Compaq Computer Corporation and Industry Standards.............................................................1–5
1.3.6.1 Telecommunications Interfaces........................................................................................1–5
1.3.6.2 Safety and Electromagnetic Compatibility.......................................................................1–5
1.3.7 System Security.........................................................................................................................1–6
1.4 Required and Optional Hardware.........................................................................................................1–6
1.4.1 AlphaServer 1000A System .......................................................................................................1–6
1.4.1.1 Overview .........................................................................................................................1–6
1.4.1.2 AlphaServer 1000A Require d Hardware........................................................................... 1–7
1.4.2 Modular Storage Shelf Subsystem (BA35x-Sx)..........................................................................1–8
1.4.2.1 Overview .........................................................................................................................1–8
1.4.2.2 Modular Storage Shelf Optional Hardware .......................................................................1–8
1.4.3 ISA Bus Expansion Chassis.......................................................................................................1–8
1.4.3.1 Overview .........................................................................................................................1–8
1.4.3.2 ISA Bus Expansion Chassis Required and Optional Hardware..........................................1–9
1.4.4 IP Power Controller Subsystem................................................................................................1–10
1.4.4.1 Overview .......................................................................................................................1–10
1.4.4.2 IP Power Controller Options...........................................................................................1–10
1.4.5 Alarm Indicator Panel..............................................................................................................1–10
1.4.6 External Hardware Options...................................................................................................... 1–11
12 Installing the AlphaServer IP Platform Hardware
2.1 Introduction.........................................................................................................................................2–1
2.2 Factory Installed Hardware..................................................................................................................2–1
2.3 Site Preparation...................................................................................................................................2–2
v
2.3.1 Preinstallation Considerations....................................................................................................2–2
2.4 Hardware Installation...........................................................................................................................2–3
2.4.1 Installing the IP Platform...........................................................................................................2–4
2.4.1.1 Connecting the Network Hardware...................................................................................2–4
2.4.1.1.1 Connecting Dialogic D/240SC-T1 and DTI/211 T-1 Modules ................................2–5
2.4.1.1.2 Connecting Dialogic DTI/212 E-1 Modules (75-Ohm) ...........................................2–6
2.4.1.1.3 Connecting Dialogic DTI/212 E-1 Modules (120-Ohm).......................................... 2–6
2.4.1.1.4 Connecting Dialogic LSI/120 Loop-Start Module...................................................2–7
2.4.1.2 IP Power Controller.......................................................................................................... 2–8
2.4.1.3 User Alarms.....................................................................................................................2–8
2.4.2 Locking Your System ................................................................................................................2–9
3 Basic Operation
3.1 Introduction.........................................................................................................................................3–1
3.2 Turning on the AlphaServer IP Platform.............................................................................................. 3–1
3.2.1 Step I: Power Controller Circuit Breakers..................................................................................3–1
3.2.2 Step II: ISA Bus Expansion Chassis........................................................................................... 3–1
3.2.3 Step III: AlphaServer 1000A System..........................................................................................3–1
3.3 Basic Operation of the IP Platform Subsystem Components ................................................................3–2
3.3.1 Alarm Indicator Panel................................................................................................................3–2
3.3.1.1 Replacing Batteries in the Alarm Indicator Panel.............................................................3–4
3.3.1.2 Dry Contacts....................................................................................................................3–5
3.3.2 AlphaServer 1000A System .......................................................................................................3–6
3.3.3 Modular Storage Shelf BA35x-Sx Subsystem ............................................................................3–7
3.3.4 ISA Bus Expansion Chassis.......................................................................................................3–8
4 Reconfiguring the AlphaServer IP Platform
4.1 Introduction.........................................................................................................................................4–1
4.2 AlphaServer 1000A System Configurations......................................................................................... 4–2
4.3 ISA Bus Expansion Chassis Configuration...........................................................................................4–3
4.3.1 Removing and Replacing the Alarm Sensor Module ..................................................................4–3
4.3.2 Removing and Replacing the AT Bus Expansion Kit.................................................................4–4
4.4 Modular Storage Shelf BA35x-Sx Subsystem Configuration................................................................4–4
4.5 Alarm Indicator Panel Configuration...................................................................................................4–5
4.5.1 Removing and Replacing the Alarm Indicator Module ...............................................................4–5
5 System Troubleshooting
5.1 Introduction.........................................................................................................................................5–1
5.2 AlphaServer 1000A Subsystem ............................................................................................................5–2
5.3 Alarm Indicator Panel..........................................................................................................................5–2
5.4 ISA Bus Expansion Chassis.................................................................................................................5–3
5.5 Modular Storage Shelf BA35x-Sx Subsystem ......................................................................................5–3
5.6 AlphaServer IP Power Controllers.......................................................................................................5–3
A AlphaServer IP Platform Specifications
A.1 Physical Dimensions..........................................................................................................................A–1
A.2 Electrical Specifications ....................................................................................................................A–1
A.3 System Environmental Specifications................................................................................................A–2
A.4 Dry Contact Specifications ................................................................................................................A–3
A.5 Central Office Compatibility.............................................................................................................. A–4
vi
B Alarm Input Wiring
B.1 Alarm Input Wiring Dia gram .............................................................................................................B–1
B.2 Wiring User Alarm Inputs..................................................................................................................B–2
C Field Wiring the -48 Vdc Power Inverter
C.1 Field Wiring the -48 Vdc Power Controllers......................................................................................C–1
C.1.1 Installing Suitable Field Wiring................................................................................................C–2
D AlphaServer IP Platform Duplex System Diagrams
D.1 Introduction....................................................................................................................................... D–1
D.2 AlphaServer IP Platform Duplex AC System .....................................................................................D–2
D.3 AlphaServer IP Platform Duplex DC System .....................................................................................D–4
E AlphaServer IP Platform Simplex System Diagrams
E.1 Introduction.........................................................................................................................................E-1
E.2 AlphaServer IP Platform Simpl ex AC System .....................................................................................E-2
E.3 AlphaServer IP Platform Simpl ex DC System .....................................................................................E-4
Glossary
Index

Figures

Figure 3-1: Alarm Indicator Panel (Front and Rear View)........................................................................3–3
Figure 3-2: Dry Contact Terminal Connectors.......................................................................................... 3–6
Figure B-1: Alarm Input Wiring Dia gra m................................................................................................B–1
Figure B-2: Alarm Control Module 8-Pin MJ Connector.........................................................................B–2
Figure D–1: IP Platform Duplex AC System Front and Side View...........................................................D–2
Figure D–2: IP Platform Duplex AC System Rear View ..........................................................................D–3
Figure D–3: IP Platform Duplex DC System Front and Side Views.........................................................D–4
Figure D–4: IP Platform Duplex DC System Rear View ..........................................................................D–5
Figure E–1: IP Platform Simplex AC System Front and Side View ......................................................... E–2
Figure E–2: IP Platform Simplex AC System Rear View......................................................................... E–3
Figure E–3: IP Platform Simplex DC System Front and Side Views........................................................ E–4
Figure E–4: IP Platform Simplex DC System Rear View......................................................................... E–5

Tables

Table 1-1: AlphaServer 1000A Require d Hardware..................................................................................1–7
Table 1-2: Modular Storage Shel f (BA35x-Sx) Optional Hardware ..........................................................1–8
Table 1-3: ISA Bus Expansion Chassis Required and Optiona l Hardware.................................................1–9
Table 1-4: IP Power Controller Options..................................................................................................1–10
Table 1-5: Alarm Indicator Panel Options .............................................................................................. 1–10
Table 1-6: Externa l Hardware Opti ons....................................................................................................1–11
Table 2-1: T-1 to D/240SC-T1 Pin Designations ......................................................................................2–5
Table 2-2: T1 to DTI/211 Pin Designations..............................................................................................2–5
vii
Table 2-3: E-1 to DTI/212 75-Ohm Pin Designations...............................................................................2–6
Table 2-4: E-1 to DTI/212 120-Ohm Pin Designations.............................................................................2–6
Table 2-5: LSI/120 Loop-Start 25-Pin Designations .................................................................................2–7
Table 2-6: LSI/120 Loop-Start 50-Pin Designations .................................................................................2–8
Table 3-1: Dry Contact Relay Functional Specification............................................................................3–6
Table 4-1: SRM Console Configuration Commands.................................................................................4–2
Table A-1: Physical Dimensions..............................................................................................................A–1
Table A-2: Electrical Specifications for Each Power Controller...............................................................A–1
Table A-3: Environmental Specifications................................................................................................A–2
Table A-4: Dry Contact Specifications....................................................................................................A–3
Table B–1: Alarm Control Module 8-Pin MJ Connector Pinout............................................................... B–2
Table C–1: Field Wire Recommendations for Each Power Feed..............................................................C–2
viii

About This Guide

The AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide describes how to set up, operate, troubleshoot, and maintain an AlphaServer Intelligent Peripheral (IP) Platform. If information is available elsewhere, this manual provides a reference to the appropriate documentation.

Intended Audience

This manual is intended for qualified system managers and technical end users trained in the installation and the servicing of computer systems.

Structure of This Document

This guide is organized as follows: Chapter 1, Product Overview – Describes the basic AlphaSe rver IP P l atf orm
configurations, the required and optional hardware, and the factory-installed software. Chapter 2, Installing the AlphaServer IP Platform Software – Provides instructions for
installing the AlphaServer IP Platform hardware. Chapter 3, Basic Operation – Describes how to turn on the AlphaServer IP Pl at form.

Preface

Chapter 4, Reconfiguring the AlphaServer IP Platform – Explains how to reconfigure the
AlphaServer IP Platform.
Chapter 5, System Troubleshooting – Provides basic troubleshooting information. Appendix A, AlphaSe r ve r P latform Specifications – Provides system and environmental
specifications. Appendix B, Al a r m Input W iring – Provides a wiring diagram of all of the alarm inputs and
wiring information for user alarm inputs. Appendix C, Field Wiring the -48 Vdc Power Inverter – Provides field wiring details for
the -48 Vdc power controllers. Appendix D, AlphaSer v e r IP P l atfor m Dupl e x Syste m Di agr ams – Contains diagrams of
the IP duplex platforms. Appendix E, AlphaSer v e r IP P l atfor m Dupl e x Syste m Di agr ams – Contains diagrams of
the IP simplex platforms. The Glossary defines technical terms related to the product. The Index locates the main topics in this guide.
ix

Conventions

This document uses the following c onve nti ons:
Convention Meaning
IP Note
Caution Warning
Italic type

Related Documen tation

Describes an industry-st andard acr onym for Int e lligent Peripheral. A note calls the reader’s attention to any item of information that may be of
special importance. A caution contains informat i on esse nti al t o avoi d dam age t o the equi pm ent . A warning contains information es sent i al t o t he saf et y of per sonnel . Circled numbers provide a li nk bet ween figur es or exam pl es and t ext . Italic type emphasi zes i m port ant i nfor mat i on, i ndicat es vari abl es, and
indicates complete titles of manuals.
For additional information on the
AlphaServer Intelligent Peripheral (IP) Platform
subsystem components and related software, refer to the documentation in the following table. Order numbers may change as documents are revised or updated. Check with your Compaq sales representative for additional information.
Document Part Number AlphaServer IP Platform
Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide
AlphaServer Intelligent Peripheral Platform System Manager's Guide
AlphaServer 1000A Processor
AlphaServer 1000A Rackmount Owner’s Guide DIGITAL UNIX Installa tion Guide StorageWorks KZPSA PCI-to-SCSI Adapter User’s Guide Site Environmental Preparation Guide
BA35x-Sx Modular Storage Shel f
BA350 Modular Storage Shelf Subsystem User’s Guide BA350 Modular Storage Shelf Subsyst em Configurat i on Guide DWZZB SCSI Signal Converter User’s Guide RZ Series Disk Drive Installati on Guide - M odels RZ35, RZ26, RZ27, RZ28
-48 Vdc Power Inverter
DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac Power Inverter Owner's Guide
ISA Bus Expansion Chassis
I-Bus 4820 User Manual Dialogic Voice Hardware Reference Dialogic Network Hardware Reference Dialogic VR/160 Hardware Reference Dialogic FAX/120 Hardware Ref er ence
AA-QN0FD-TE
AA-QU0JC-TE
EK-RMNOR-OG AA-QTLGB-TE EK-KZPSA-UG EK-CSEPG-MA
EK-BA350-UG EK-BA350-CG EK-DWZZB-UG EK-DRZ01-IG
EK-48VDC-OG
109-40020-00 BX-QLTUA-TE BX-QLTTA-TE BX-QLTVA-TE BX-QLTSA-TE
x

1.1 Introduction

This chapter includes the following topics:
IP Platform Overview
IP Platform Features
IP Platform Required and Optional Hardware

1.2 IP Platform Overview

The AlphaServer Intelligent Peripheral (IP) Platform provides a full suite of hardware and software components for voice processing, telephony and data communications, management, processing, and storage. The se c ompone nt s are c om bine d t o ma ke a hi gh pe rforma nc e, hi gh availability, rackmount-configured IP Platform, that meets certain standards and specifications.
There are two basic AlphaServer IP Platf orm configurations upon which all platform systems are built:
1

Product Overview

IP Simplex System
IP Duplex System There may also be custom variations of the IP platform. Each rackmount platform requires a console terminal to display all system alarm messages
and manage alarm conditions. Basic AlphaServer IP Platform management functions are designed to ensure the integrity of
the platform and to allow for the management of the platform itself. The management functions include alarming based on critical events, for example; hardware failure, logging of events and activities, management of the individual resources, and system security. These functions are described in t he Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide 1–1
Product Overview

1.2.1 IP Simplex System

The simplex system is a central office compatible rackmount system intended for Telco central office environments. It contains one each of the following components:
• AlphaServer 1000A system running the Compaq Tru64 UNIX (formerly DIGITAL
UNIX) opera t ing system
ISA bus expansion chassis
Alarm indicator panel
• StorageWorks BA35x-Sx mass storage disk drive subsystem (optional)
Rackmount power controller (120 Vac, 250 Vac, or -48 Vdc models)
Refer to Appendix E for diagrams of the IP simplex system.

1.2.2 IP Duplex System

The duplex rackmount configuration is a central office compatible rackmount system intended for Telco central office environments and is suitable for live network implementations. The duplex system includes two each of the following components:
• AlphaServer 1000A system running the Tru64 UNIX operating system
ISA bus expansion chassis
Alarm indicator panel
• StorageWorks BA35x-Sx mass storage disk drive subsystems (optional) (connected
together with BN21W-0B and BN21K-XX SCSI bus cables) with disks that can be striped and/or mirrored
Two rackmount power controllers (120 Vac, 250 Vac) or one rackmount power controller (-48 Vdc)
TruCluster software can be ordered separately and is recommended for enhanced availability with application-defined failover services.
Refer to Appendix D for diagrams of the IP duplex system.
1–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide

1.2.3 Factory Installed Software

The IP platform supplied by Compaq Computer Corporation is delivered to the customer with the following factory-installed software:
• Tru64 UNIX operating system
Dialogic drivers for Tru64 UNIX that offer the following functionality:
Voice processing (digitization, call control)
Telephony network interfaces (loop-start, T-1, E-1)
FAX
Voice recognition
• ServerWORKS Agent
• Advanced File System Utilities
• Logical Storage Manager
• TruCluster Available Server for Tru64 UNIX (optional)
• Intelligent Peripheral Fault Manager (IPFM) for the Tru64 UNIX operating system
Product Overview
• DECevent Translation Utility All systems include the IP Fault Manager software that detects various system events and
performs pre-configured actions for each event. Solution developers can also use the IP Fault Manager to display application alarmed events
on the IP alarm panel and to log events. A complete description of the IP Fault Manager is included in the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide.
For additional information on how to use the factory-installed software, refer to the individual product's documentation.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–3
Product Overview

1.3 System Features

This section provides a brief description of the system features of the AlphaServer IP Platform.

1.3.1 User Interfaces

The AlphaServer IP Platform is designed to work in real-time public networks of telecommunications service providers. System and network management activities are performed by means of a separate data communications network rather than the telephony communications network (for example, voice or signaling). Both graphical user interfaces (GUIs) and character cell displays are supported, depending on the interfaces provided by the layered products on the IP Platform.
Command line or character cell displays are used for objects that do not have a GUI, or as a supplement to those with a GUI. Command line interfaces can be run over a low-speed dial­up modem with minimal communication protocol support.

1.3.2 Alarm Subsystem

The alarm subsystem of the AlphaServer IP Platform provides alarming functions to the platform. These functions include the following:
Visual indication of an alarmed event
Audible indication of an alarmed event
Programmable external event notification
Diagnostic capability
Battery-backup for alarm indicators
Programmable software interface with interrupt capability
Dry contacts for remote monitoring of alarms
The alarm subsystem is comprised of two physical modules: an alarm control module that resides on the PCI bus, and an alarm indicator panel, which contains all of the visual and audible indicators.

1.3.3 Maintainability

All configurations are designed with front access for all user devices contained in the AlphaServer 1000A system, the ISA bus expansion chassis, and the modular storage shelf BA35x-Sx subsystem. All nonuser devices have rear access.
The AlphaServer 1000A system and the ISA bus expansion chassis are slide mounted for ease of maintenance.
The BA35x-Sx application storage disks are hot-swappable.

1.3.4 Reliability

Each Compaq Computer Corporation component of this system will function reliably over time as long as the hardware options used are not altered. All of the Compaq options used in the design of this system meet Compaq Computer Corporation standards for reliability. However, the reliability of the equipment supplied by other vendors is determined by the manufacturer of each device.
1–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide

1.3.5 Upgrading

Additional hardware and software opt i ons may be a dded t o your A l phaServe r IP P lat f orm components. For a complete list of available options, refer to the individual component's documentation listed in the Related Documentation section of the Preface in this guide.
___________________________ Important _________________________
FCC and safety review is valid only for options listed in this guide.
______________________________________________________________

1.3.6 Compaq Computer Corporation and Industry Standards

The AlphaServer IP Platform conforms to the industry standards outlined in the following subsections.
1.3.6.1 Telecommunications Interfaces
The AlphaServer IP Platform conforms to the following telecommunications interface standards when Telephony boards are installed:
T-1 (24-channel, PCM encoded analog) digital network interface
E-1 (30-channel, PCM encoded analog) digital network interface
Product Overview
Loop-start signaling
Ground-start signaling
E&M wink-start signaling
1.3.6.2 Safety and Electromagnetic Compatibility
The AlphaServer IP Platform conforms to the following safety and electromagnetic compatibility standards:
FCC Part 15, Subpart J
CSA (Canad i an Standards Association) C22.2 No. 950-93
UL (Underwriters Laboratory) 1950
TUV EN 60950
CE Class A
C-Tick Mark
BSMI
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–5
Product Overview

1.3.7 System Security

The AlphaServer IP Platform contains front and rear key locking doors to limit access to system components. Each AlphaServer IP Platform comes with a duplicate set of front and rear door keys.
In addition, each AlphaServer 1000A system contains a key to lock the individual processor. Refer to the AlphaServe r 1000A R ack mount Owner's Guide for instructions on locking the
AlphaServer 1000A system.
______________________________ Note ____________________________
Record the key number for each cabinet door and each CPU. Store this information in a safe place; you will need the information if replacement is necessary.
_______________________________________________________________

1.4 Required and Optional Hardware

This section provides a brief description of each major component of the AlphaServer IP Platform, and lists the required and optional hardware. Contact your Compaq sales
representative for the current supported options and ordering information.

1.4.1 AlphaServer 1000A System

This section describes the AlphaServer 1000A system. It also lists the required hardware for this system.
1.4.1.1 Overview
The AlphaServer 1000A system is an Alpha uniprocessor server running the Tru64 UNIX operating system. A single IP cabinet can support up to two AlphaServer 1000A systems. The AlphaServer 1000A system drives all functions within the IP Platform, including voice processing, management, and communications. In addition, application, service, and other layered software run on an Al phaServe r 1000A system. The AlphaServer 1000A offers high reliability features such as ECC memory and ECC cache.
The AlphaServer 1000A system includes:
9 expansion slots: 7 PCI slots and 2 EISA slots
256 MB memory, expandable to 1 GB memory
Integrated Fast-Wide Single-Ended SCSI-2 controller (supports wide and narrow drives)
Multiple drive bays supporting a 1.44 MB floppy diskette, RRD4 x-xx CD-ROM, 1 available removable media drive bay, and 3 3.5-inch hard disks
2 serial ports (9-pin) and one enhanced bi-directional parallel port (25-pin)
For additional information on the AlphaServer 1000A system features and capabilities, see the AlphaServer 1000A Rackmount Owner's Guide.
1–6
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1.4.1.2 AlphaServer 1000A Required Hardware
Table 1-1 lists the requi re d hardware for t he Al phaSe rve r 1000A system. Refer to the DIGITAL Systems and Options Catalog for descriptions of optional hardware.
Table 1-1: AlphaServer 1000A Required Hardware
Part Number Description Simplex Duplex
PB79D-RA RM
PB7MA-CE 256 MB memory 1 2 2T-VC220-IP AT bus expansion kit (EISA/ISA module) Access
2T-IPCON-AA Alarm control module 1 2 RZ1CB-BS 4.3 GB SCSI hard disk drive
RRD47-AA 32 X CD-ROM drive 1 2 PBXTL-DA 8.0 GB SCSI 4 mm DAT drive 1 2
AlphaServer
System, includes RX23 floppy dri ve
I/O transmitter and receiver modules and 2-meter
cable
Note:
Each simplex and duplex configurat i ons ar e preconfigured with one wide disk for sys tem f i l es and data
1000A 5/500
AlphaServer
Tru64 UNIX
1000A system in the
12
12
12
Product Overview
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–7
Product Overview

1.4.2 Modular Storage Shelf Subsystem (BA35x-Sx)

This section provides a brief description of the modular storage shelf subsystem.
1.4.2.1 Overview
The StorageWorks disk drive subsystem is a rackmount storage resource provided to solution developers and service developers creating applications on the AlphaServer IP Platform. The shelves are contained in a separate chassis that provides a flexible capacity for adding and hot-swapping disks.
The shelf is a self-contained unit with embedded backplane routing with two SCSI buses. It can be configured for maximum connectivity (1 SCSI bus) or for maximum performance (2 SCSI buses).
Each StorageWorks modular storage shelf houses all the application storage disks in a rackmount shelf. The following table lists the type of disks that can be used. For additional information, see the BA350 Modular Storage Shelf Subsystem Configuration Guide.
1.4.2.2 Modular Storage Shelf Optional Hardware
Table 1-2 lists the hardware opt ions for the BA35x-Sx modula r storage shel f.
Table 1-2: Modular Storage Shelf (BA35x-Sx) Opt ional Hardware
Part Number Description
BA35x-Sx Rackmount DS-RZ1CF-VW DWZZB-VW Fast, wide, different i al to s i ngle ended SCSI conver t er f or BA35x-Sx.
KZPSA-BB Fast, wide, differential SCSI controller. H885-AA Tri-link connector block. H879-AA SCSI termi nat or .
StorageWorks
Terminates SCSI bus at storage unit.

1.4.3 ISA Bus Expansion Chassis

This section describes the ISA bus expansion chassis.
1.4.3.1 Overview
The I-Bus 4820-2819 enclosure is used as a 20-slot ISA bus expansion chassis for the AlphaServer 1000A system. The ISA bus expansion chassis contains all Dialogic voice modules for its associated AlphaServer 1000A simplex and duplex systems. The I-Bus 4820­2819 enclosure contains an alarm sensor module which monitors temperature, dc power, and
cooling fan rotation. If any of these reach a point of failure, an alarm signal is sent to the AlphaServer 1000A.
The ISA bus expansion chassis connects to the AlphaServer 1000A system as follows:
The ISA bus expansion chassis connects to the AlphaServer 1000A EISA bus by means of the AT (ISA) bus expansion kit (PN 2T-VC220-IP).
StorageWorks
disks for BA35x enclosure. 4.3 GB disks.
in BA35x-Sx enclosure.
The ISA bus expansion chassis alarm inputs connect to the AlphaServer 1000A system by means of a cable.
1–8
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1.4.3.2 ISA Bus Expansion Chassis Required and Optional Hardware
The ISA bus expansion chassis connects to the AlphaServer 1000A EISA bus by means of the AT (ISA) bus expansion kit. The AT (ISA) bus expansion kit includes transmitter and receiver modules and an interconnecting cable. The transmitter module resides in the AlphaServer 1000A system, the receiver module resides in the ISA bus expansion chassis, and the cable connects both modules.
Table 1-3 contains the required and optional hardware for the ISA bus expansion chassis. All hardware listed in Table 1-3 can be ordered separately as spare parts.
Table 1-3: ISA Bus Expansion Chassis Required and Optional Hardware
Part Number Description Simplex Duplex
2T-VC221-IB ISA bus expansion chassis 1 2 2T-VC220-IP 2T-LDMOD-AA Load module 1 2 2T-VC24T-xx
2T-VC211-xx
2T-VC212-xx
2T-VC320-xx
2T-VCLSI-xx
2T-VC121-xx
2T-VCFAX-xx
2T-VCF4E-xx
2T-VCVRP-xx
2T-VCVR4-xx
2T-VCVR2-xx
2T-VCDMX-xx
1
xx represents a two-lett er count r y code. Contact your Compaq sal es repr esent at i ve for add i t i onal
information.
2
Confirm that there are no cards in the ISA bus expansion chassis that use the Compressed Wri te
Timing (“zero-wait-state”) signal . The 2T-VC220-IP option does not servi ce thi s si gnal .
2
Access I/O AT bus expansion kit with 2-meter cabl e 1 2
1
Dialogic D/240SC-T1, 24-channel, high-densi t y voice­processing and network-interface m odul e
1
Dialogic DTI/211, 24-channel, standar d- densi ty, T-1 network-interface module
1
Dialogic DTI/212, 30-channel, standar d- densi ty, E-1 network-interface module
1
Dialogic D/320SC, 32-channel, high-densi t y, voice­processing module
1
Dialogic LSI/120, 12-channel, st andar d-dens it y, anal og loop-start network-inter face m odule
1
Dialogic D/121B, 12-channel, standard- densi t y, anal og loop-start call- pr ocessi ng m odul e
1
Dialogic FAX/120, 12-channel, standard-dens i ty, FAX processing module
1
Dialogic VFX/40E, 4-channel, low-density, anal og l oop­start call-proces si ng and 14, 400 b/s FAX processing module
1
Dialogic VRP, 4/8/12/16-channel, st andar d-dens it y, voice-recognition modul e
1
Dialogic VRM/40, 4-channel, discrete voice-recognition daughterboard
1
Dialogic VRM/2C, 2-channel, continuous voi ce­recognition daughterboard
1
Dialogic DMX: Digital Matrix Switch connecting up to four PCM expansion buses (PEBs)
Product Overview
Opt Opt
Opt Opt
Opt Opt
Opt Opt
Opt Opt
Opt Opt
Opt Opt
Opt Opt
Opt Opt
Opt Opt
Opt Opt
Opt Opt
_____________________________ Note____________________________
The list of supported options is updated on a regular basis. Please contact your Compaq sales representative for a current list of supported options.
______________________________________________________________
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–9
Product Overview

1.4.4 IP Power Controller Subsystem

This section briefly describes the IP power controller subsystem.
1.4.4.1 Overview
Each rackmount simplex and duplex IP Platform contains one or two power controllers located in the bottom rack of the cabinet. Each controller provides power to one ISA bus expansion chassis, one BA35x-Sx modular storage shel f, and one A lphaSe rve r 1000A processor.
The AlphaServer IP Platform supports the following power controller models: 120 Vac, 250 Vac, or -48 Vdc. In addition, each processor and associated voice, storage, and communication resource has its own individual power supply.
Refer to Appendix C for instructions on field wiring the -48 Vdc power controllers for power.
1.4.4.2 IP Power Controller Options
Table 1-4 lists the IP power controller options.
Table 1-4: IP Power Controller Options
Part Number Description Simplex Duplex
H7600-AA 120 Vac power distributi on unit t hat provi des t en ( 10) ac
outlets, an attached power cord wit h an L5-30P plug, an on/off circuit br eaker, and a power-on l i ght .
H7600-DB 250 Vac power distributi on unit t hat provi des t welve (12)
IEC 320 ac outlets, an attached power cord with an I EC 309 plug, an on/off circui t breaker , and a power-on l i ght.
2T-48VDC-AA 3 kW (N+1) -48 Vdc power inverter (-48 Vdc to 120 Vac
dual converter).
2T-48VDC-AB 2 kW (N+1) -48 Vdc power inverter ( -48 Vdc to 120 Vac
dual converter).
12
12
01
10

1.4.5 Alarm Indicator Panel

The alarm indicator panel provides programmable visual and audible alarm indicators for the IP Platform.
Table 1-5 lists the alarm indicator panel options.
Table 1-5: Alarm Indicator Panel Options
Part Number Description Simplex Duplex
2T-IPAIP-CA Alarm indicator panel for t he si m plex I P Pl atf orm s . 1 NA 2T-IPAIP-CB Alarm i ndi cat or panel f or t he dupl ex IP Pl at for ms . NA 1
1–10
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide

1.4.6 External Hardware Options

Table 1-6 contains external hardware options.
Table 1-6: E xt ernal Hardware Options
Part Number Description
LA75S-AA FR-B16AP-EG
(or equivalent) VT520, VT525
(or equivalent)
LA75 Plus Companion
Personal computer for
Console terminal
Product Overview
printer for hardcopy syst em output
ServerWORKS
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
1–11
is some white text.
2

Installing the AlphaServer IP Platform Hardware

2.1 Introduction

This chapter includes the following topics:
Factory installed hardware
Site preparation
Hardware installation

2.2 Factory Installed Hardware

The AlphaServer Intelligent Peripheral (IP) Platform is configured and delivered according to customer specification, with all hardware and software factory-installed. It is shipped ready for connection to a customer's power source and network hardware.
_____________________________ Note____________________________
Value-added Implementation Services (VIS) is available for the AlphaServer IP Platform products. VIS provides high-quality integration, test verification, and
site installation; each process is performed by experienced service personnel. See your Compaq sales representative for additional information.
______________________________________________________________
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide 2–1
Installing the AlphaServer IP Platform Hardware

2.3 Site Preparation

This section describes the site-specific installation requirements for the IP Platform.
_____________________________Caution___________________________
Review your system warranty. It may require that a Compaq service representative install your system to prevent damage to equipment or software.
_______________________________________________________________
____________________________ Achtung __________________________
Überprüfen Sie die Garantie Ihres Systems. Eventuell muß Ihr System, gemäß der Garantie, vom Compaq-Kundendienst installiert werden, um Beschädigungen am Gerät oder an der Software zu verhi nde rn.
_______________________________________________________________

2.3.1 Preinstallation Considerations

Before you install the AlphaServer IP Platform, ensure that:
The installation site meets the specifications and environmental conditions listed in Appendix A. For more information about planning and preparing the installation site for a computer network for a free-standing system, refer to the Site Environmental Preparation Guide. (PN EK-CSEPG-MA. Available by calling 1-800-344-4825.)
The power source is correct for your system, and is one of the following models: 120 Vac, 250 Vac, or -48 Vdc.
You have the correct number of T-1, E-1, or loop-start network connections and adequate cabling.
______________________________ Note ____________________________
The T-1 cable le ngt h from t he net work to t he A l phaServe r IP P lat f orm cannot exceed 199.6 m (655 ft) without a repeater. Do not use a repeater for cable lengths less than 199.6 m (655 ft).
_______________________________________________________________
The system is located in an area that provides 61 cm (24 in.) clearance from the rear of the cabinet, and 76.2 cm (30 in.) from the front of the cabinet for ventilation and servicing.
Personnel are appropriately trained in the installation and operation of this system.
2–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide

2.4 Hardware Installation

This section describes the installation and setup of the IP Platform.
___________________________ WARNING _________________________
Only a qualified service person should install the system. A qualified service person is an individual who has the technical training and experience to be aware of the:
Hazards to which they are exposed in performing a task
Measures to minimize the danger to themselves or other persons
A qualified service person need not be a Compaq service representative.
______________________________________________________________
___________________________VORSICHT _________________________
Das System darf nur von qualifizierten Fachleuten installiert werden. Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult sind und über die nötige E r f a hr ung verfügen, um :
die Gef a hr e n zu erkenne n, denen sie be i der Ausführung de r Arbeit ausgesetzt sein könnten
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst
und für andere Personen zu ergreifen. Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des Compaq­Kundendienstes.
______________________________________________________________
Installing the AlphaServer IP Platform Hardware
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
2–3
Installing the AlphaServer IP Platform Hardware

2.4.1 Installing the IP Platform

After you have verified the installation site, install the AlphaServer IP Platform by performing the following steps:
1. Position the cabinet, allowing a 60.96 cm (24 in) minimum rear aisle clearance and a
76.2 cm (30 in) minimum front aisle clearance.
2. Level the cabinet using the four-point leveling hardware.
3. If a -48 Vdc power inverter is installed in the platform, bolt the AlphaServer IP Platform to the floor at the cabinet base using the front and rear shipping brackets (and optionally at the top, using the appropriate central office conforming hardware). Local codes may prohibit bolting the cabinet to the floor if H7600 power distribution units are installed.
4. Connect to the network hardware (see Section 2.4.1.1).
5. Connect the IP Platform to the appropriate power supply. See Appendix C for instructions on wiring the -48 Vdc controllers if your system has them installed. Refer to the power ratings listed on the cabinet part number label located at the rear of the cabinet above the door.
6. Verify the hardware setup. Before you turn on the system, check to ensure that the IP Platform is properly secured, and the power controller and network hardware connections are correct.
7. Power up the system. See Section 3.2.
2.4.1.1 Connecting the Network Hardware
This section describes how to install Dialogic's voice-processing, voice-recognition, and network-interface T-1, E-1, and loop-start modules to the building's network hardware.
Refer to the Dialogic Network Hardware Reference and the Dialogic Voice Hardware Reference for diagrams of the Dialogic modules and for additional information on the Dialogic modules. All Dialogic modules are installed in the ISA bus expansion chassis.
2–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Installing the AlphaServer IP Platform Hardware
2.4.1.1.1 Connecting Dialogic D/240SC-T1 and DTI/211 T-1 Modules
On the rear bracket of the D/240SC-T1 and DTI/211 network modules is an RJ-48C jack for connecting to the T-1 network. The cabling between this jack and the CSU or other DSX-1 equipment should be 4-pair telephone line or equivalent. The network interface module of the cable should consist of an RJ-48C plug. The user is responsible for supplying an appropriate cable for these connections. The pin designations for the network interface module cable end for D/240SC-T1 modules are specified in Table 2-1.
Table 2-1: T-1 to D/240SC- T1 Pin Designations
Signal Pin(s)
Receive ring: input to network int er face m odul e 1 Receive tip: input to network int er f ace modul e 2 No connection 3, 6 Transmit ring: output from network interface module 5 Transmit tip: output from network interface module 4 Optional shield 7, 8
The pin designations for the network interface module cable end for DTI/211 T-1 modules are specified in Table 2-2.
Table 2-2: T1 to DTI/211 Pin Designations
Signal Pin(s)
Receive ring: input to network int er face m odul e 1 Receive tip: input to network int er f ace modul e 2 No connection 3, 6 Transmit ring: output from network interface module 4 Transmit tip: output from network interface module 5 Optional shield 7, 8
Refer to the Dialogic Network Hardware Reference for additional information on DTI/211 T­1 modules. Refer to the Dialogic Voice Hardware Reference for additional information on D/240SC-T1 modules.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
2–5
Installing the AlphaServer IP Platform Hardware
2.4.1.1.2 Connecting Dialogic DTI/212 E-1 Modules (75-Ohm)
The Dialogic DTI/212 E-1 m odul es com e in 75-ohm a nd 120-ohm ve rsions. If you ha ve a DTI/212 120-ohm module, see Section 2.4.1.1.3. Refer to the Dialogic Net work Hardware Reference for additional information on DTI/212 E-1 modules.
On the rear bracket of the DTI/212 75-ohm module are two BNC-type jacks for connecting to the external E-1 network. The cabling between these jacks and the external E-1 network should be 75-ohm coaxial. The DTI/212 end of the cable should consist of a BNC-type male connector. The user is responsible for supplying an appropriate cable for these connections. The pin designations for the DTI/ 212 75-ohm ca bl e ends are gi ve n in T a ble 2-3.
Table 2-3: E - 1 to DTI/ 212 75- Ohm Pin Designations
Signal Jack/Pin
Transmit data: output from DTI/212 (tip) J201A center Transmit data: output from DTI/212 (ring) J201A shield Receive data: input to DTI/212 (ti p) J201B center Receive data: input to DTI/212 (ri ng) J201B shield
To cable the DTI/212 75-ohm m odule t o the E -1 net work, fol l ow these ste ps:
1. Attach the appropriate end of the E-1 to DTI/212 (receive) cable to jack J201B on the rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and lock by turning a quarter-t urn c loc kwise.
2. Attach the appropriate end of the DTI/212 to E-1 (transmit) cable to jack J201A on the rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and lock by turning a quarter-t urn c loc kwise.
2.4.1.1.3 Connecting Dialogic DTI/212 E-1 Modules (120-Ohm)
On the rear bracket of the DTI/212 120-ohm module is an RJ-48C jack for connecting to the external E-1 network. The cabling between this jack and the CSU should be 120-ohm twisted pair or equivalent. The DTI/212 120-ohm end of the cable should consist of an RJ-48C plug. The user is responsible for supplying an appropriate cable for these connections. The pin designations for the DTI/212 120-ohm ca bl e e nds are gi ven i n T a ble 2-4.
Table 2-4: E - 1 to DTI/ 212 120- Ohm Pin Designations
Signal Pin(s)
Receive ring: input to the DTI/212 120-ohm m odul e 1 Receive tip: input to the DTI/212 120-ohm m odul e 2 No connection 3, 6 Transmit ring: output from the DTI/212 120-ohm module 5 Transmit tip: output from the DTI/212 120-ohm module 4 Optional shield 7, 8
2–6
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Installing the AlphaServer IP Platform Hardware
To cable the DTI/212 120-ohm m odule t o the E -1 net work, fol l ow these ste ps:
1. Align the RJ-48C connector at the DTI/212 120-ohm module end of the E-1 to DTI/212 120-ohm cable with jack J201 on the rear bracket of the DTI/212 module.
2. Gently push the cable connector into the RJ-48C jack until it snaps into place.
2.4.1.1.4 Connecting Dialogic LSI/120 Loop-Start Module
The customer is responsible for supplying additional cabling to connect the LSI/120 network interface module to the telephone company lines.
Refer to the Dialogic Network Hardware Reference for additional information on LSI/120 modules.
You can choose from the following connection options:
Use Compaq's BC22F cable. This cable has a DB-25 connector on one end (to connect to the LSI/120), and a 50-pin connector on the other end that provides 12 tip and ring pin pairs that are compatible with a standard RJ-21X USOC jack.
Use Dialogic's SA/120 RJ-11 assembly. This assembly accepts the 50-pin male connector from the SA/120 RJ-21 cable and terminates with 12 RJ-11 connectors. This cable allows you to connect individual subscriber lines to the LSI/120.
The pin-out specifications in Table 2-5 and Table 2-6 are for connector P3 on the LSI/120. This cable uses a 25-pin female DB-25 connector (Amphenol part number 745495-2 or equivalent) on the LSI/120 end, and a 50-pin jack (Amphenol part number 157-72500-3 or equivalent) that is compatible with an RJ-21X USOC jack.
Table 2-5: LSI/120 Loop-Start 25-Pin Designations
TIP 8 1 14 RING 12 RING 8 2 15 TIP 12 TIP 9 3 16 RING 11 RING 9 4 17 TIP 11 TIP 4 5 18 RING 10 RING 4 6 19 TIP 10 TIP 7 7 20 TIP 3 RING 7 8 21 RING 3 TIP 6 9 22 RING 1 RING 6 10 23 TIP 1 TIP 5 11 24 RING 2 RING 5 12 25 TIP 2 RESERVED 1 3
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
2–7
Installing the AlphaServer IP Platform Hardware
Table 2-6: LSI/120 Loop-Start 50-Pin Designations
RING 1 1 26 TIP 1 RING 2 2 27 TIP 2 RING 3 3 28 TIP 3 RING 4 4 29 TIP 4 RING 5 5 30 TIP 5 RING 6 6 31 TIP 6 RING 7 7 32 TIP 7 RING 8 8 33 TIP 8 RING 9 9 34 TIP 9 RING 10 10 35 TIP 10 RING 11 11 36 TIP 11 RING 12 12 37 TIP 12 RING NC 13 38 TIP NC RING NC 14 39 TIP NC RING NC 15 40 TIP NC RING NC 16 41 TIP NC RING NC 17 42 TIP NC RING NC 18 43 TIP NC RING NC 19 44 TIP NC RING NC 20 45 TIP NC RING NC 21 46 TIP NC RING NC 22 47 TIP NC RING NC 23 48 TIP NC RING NC 24 49 TIP NC RING NC 25 50 TIP NC
2.4.1.2 IP Power Controller
The
AlphaServer IP Platform
supports the following power controller models: 120 Vac, 250 Vac, or -48 Vdc. Each simplex and duplex rackmount system has one or two power controllers located in the bottom of the cabinet. Each controller supports one BA35x-Sx, ISA bus expansion chassis, and an
AlphaServer
1000A system.
Instructions for wiring the -48 Vdc power controllers to the building's power source are included in Appendix C.
2.4.1.3 User Alarms
If the
AlphaServer IP Platform
does not use the -48 Vdc power controller, the user can connect up to three external TTL signal alarms to the 8-pin MJ connector on the alarm control module. Refer to Appendix B for a pinout of this connector and the
Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide
configuring these alarms.
2–8
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Intelligent
for information on

2.4.2 Locking Your System

The AlphaServer IP Platform is protected by a key lock in the front and rear door panels. Duplicate interchangeable sets of keys are provided for both front and rear locks.
The AlphaServer 1000A system also comes with a set of keys for each CPU.
_____________________________ Note____________________________
Store the keys in a safe place. Record the key number for each cabinet door and each CPU. Store this information in a safe place; you will need the information if replacement is necessary.
______________________________________________________________
The AlphaServer 1000A Rackmount Owner's Guide contains additional information about the AlphaServer 1000A locking procedure.
Installing the AlphaServer IP Platform Hardware
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
2–9
This is some white text.

3.1 Introduction

This chapter describes:
Turning on the AlphaServer IP P l atf orm
Basic operation of the IP Platform subsystem components

3.2 Turning on the AlphaServer IP Platform

After the AlphaServer IP Platform is properly secured, plugged in, and connected to the building's network hardware, you are ready to power up the system. Refer to Appendix D and Appendix E for the IP Platform diagrams to assist you in locating the system components.

3.2.1 Step I: Power Controller Circuit Breakers

Prior to turning on the circuit breakers for the 120 Vac or 250 Vac controllers, ensure that the neon indicator is on, indicating that an ac voltage is present. The -48 Vdc controller does not have an indicator for voltage; it should be connected to the -48 Vdc battery/power source prior to turning on the circ ui t bre a kers.
3

Basic Operation

To start powering up the AlphaServer IP Platform, switch the circuit breakers at each power controller (located in the rear of the cabinet) to the on position. The modular storage shelf BA35x-Sx automatically powers up.

3.2.2 Step II: ISA Bus Expansion Chassis

To power up the ISA bus expansion chassis, press the On/Off switch on the front of the ISA bus expansion chassis. The green ON/Off indicator on the front of the ISA bus expansion chassis will illuminate.

3.2.3 Step III: AlphaServer 1000A System

Turn the AlphaServer 1000A system on by pressing the On/Off switch on the front of the AlphaServer 1000A unit. The green On/Off indicator on the front of the system will
illuminate. At this point in the IP Platform power on sequence, the alarm indicator panel should have the
green OK LED lit and the status display will contain either a “b” indicating discharged or partially charged batteries, or it will be blank.
As described in the following sections, each subsystem within the IP Platform initiates its own self-test at power-up. The following sections describe what a successful power-up of the subsystem components looks like.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide 3–1
Basic Operation

3.3 Basic Operation of the IP Platform Subsystem Components

The following sections describe the basic operation of the IP Platform subsystem components.

3.3.1 Alarm Indicator Panel

The alarm indicator panel (see Figure 3-1) contains the following:
Visual indicators
Audible indicator
Battery backup logic
Keep-alive function
Dry contacts
Visual Indicators
The alarm indicator panel has three alarm LED indicators. These LED indicators are defined as follows:
Critical (red LED)
Major (red LED)
Minor (amber LED)
The LED for a particular level of severity will be lit as long as at least one event of that level is active. Multiple LEDs may be simultaneously lit.
The alarm indicator panel has two other indicators used for status information. These are the following:
Status display
Alarm indicator panel OK LED (green)
The status display is used to output status as a result of the diagnostic testing and to display other status information as shown in the following tables.
The OK LED is lit after a successful reset and will remain lit until either an unsuccessful reset or a loss of battery power occurs.
Refer to the Intelligent Peripheral Fault Manager For Tru64 UNIX Installation and User's Guide for additional information on the alarm indicator panel and fault management.
______________________________ Note ___________________________
The alarm indicator panel should not be permanently removed without de­configuring it in the Intelligent peripheral Fault Manager (IPFM) config file. Refer to the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation
and User's Guide.
______________________________________________________________
3–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Basic Operation
The following table describes the normal conditions of the alarm indicator panel when the AlphaServer 1000A is powered on and the Intelligent Peripheral Fault Manager (IPFM) software is running.
Condition OK LED Minor Alarm LED Status Display Audible Alarm
Fully discharged batteri es On Off “b” Off Fully charged batteries On Off “Rotating bar” Off Partially charged
batteries Software Diagnostics On Off “d” Off Softwa re Test On Off “t” Off
If the AlphaServer 1000A system looses power while the IPFM software is running, the following table describes the possible conditions of the alarm indicator panel.
Condition OK LED Minor Alarm LED Status Display Audible Alarm
Fully discharged batteri es Off Off blank Off Fully charged batteries On On “p” On Partially charged
batteries
On Off “b” Off
On On “b” On
Figure 3-1 shows a front and rear view of the alarm indicator panel.
Figure 3-1: Alarm Indicator Panel (Front and Rear View)
Front View
CRITICAL
MAJOR
MINOR
_
Battery
_
Battery
A
L P H A S E R V E R
+
+
AUDIBLE
DISABLE
I P F
A U L T M A N A G E R
_
Battery
_
Battery
STATUS
OK
+
_
Battery
+
+
J8
J3 J5 J4 J2
_
J1
Rear View
J6 J14 J15
Battery
_
Battery
+
+
ML014057
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
3–3
Basic Operation
Audible Indicator
The audible indicator has three distinct sounds associated with the three levels of alarming. This indicator is controlled by software through the alarm control module or by a disable switch on the alarm indicator panel itself. The audible indicator will sound at the level of the most severe alarmed event that is currently active. No more than one level of audible alarm can be enabled at any one time. The disable switch turns off the current audible alarm until a new event occurs that is of equal or greater severity level than the highest level alarm currently active, or until the event causing the audible alarm is cleared and another alarmed event is pending.
The three audible alarm levels are defined as follows:
Critical is two beeps, the first separated from the second by 0.5 seconds or less. This double beep pattern is repeated every 1.5 seconds.
Major is one beep every 1.5 sec onds.
Minor is one beep every 5 seconds.
Battery Backup Logic
The battery backup logic is designed to keep the current indicator status functioning for the life of the batteries (approximately 60 to 120 minutes) in the event of a power failure. It provides an indication if the batteries are low by displaying a “b” in the status display.
Keep-Alive Function
The alarm indicator panel houses a timer that is used to ensure that the CPU controlling it is still running. The function is enabled by software, which starts a timer. As long as software resets the timer before expiration, a “rotating bar” is displayed in the status display, otherwise a minor alarm is generated. A minor alarm will also be generated if power to the alarm indicator panel is lost and a “p” will be displayed in the status display.
3.3.1.1 Replacing Batteries in the Alarm Indicator Panel
The alarm indicator panel contains seven 1.2 V, 600 mA, NICD type AA rechargeable batteries that provide battery backup for providing alarm information when the system loses power or is turned off. When an alarm indicator panel continuously indicates a low battery condition in the absence of a power loss, the batteries should be replaced. These batteries should be replaced only with the same type batteries (PN 12-41230-04) or the equivalent batteries.
______________________________ Note ___________________________
Compaq recommends that batteries be replaced every two to two and a half years as preventative maintenance.
______________________________________________________________
Perform the following procedure to replace the batteries in an alarm indicator panel:
1. Power down the AlphaServer 1000A system.
2. At the front of the cabinet, remove the four screws that secure the alarm indicator panel frame to the front rails.
3. Disconnect the miniature 26-pin cable(s) from the connector(s) on the rear of the alarm indicator panel(s).
4. On the rear of the alarm indicator panel that indicates a low battery condition, remove the two screws that secure the miniature 26-pin connector to the rear cover.
3–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Basic Operation
5. Remove the three scre ws from the top e dge and t he thre e screws from the bot tom e dge of the alarm indicator panel frame that secure the alarm indicator panel rear cover.
6. Remove the alarm indicator panel rear cover.
7. Remove the seven batteries from the battery holders.
___________________________ WARNING _________________________
Replace the batteries with the same type (PN 12-41230-04) or an equivalent type recommended by the battery manufacturer. Danger of explosion exists if batteries are incorrectly replaced. Discard used batteries according to battery manufacturer instructions. Be certain to follow any applicable country, state, or local statutes for proper battery disposal.
______________________________________________________________
___________________________ VORSICHT _________________________
Ersetzen Sie die Batterien nur durch Batterien des gleichen (PN 12-41230-04) oder ähnlichen Typs, so wie es vom Hersteller empfohlen wird. Wenn Sie die Batterien falsch auswechseln, besteht Explosionsgefahr. Folgen Sie bei der Beseitigung der alten Batterien sowohl den Anweisungen des Batterieherstellers als auch den jeweiligen länderspezifischen bzw. lokalen Vorschriften zur richtigen Batteriebeseitigung.
______________________________________________________________
8. Observing proper polarity, install the seven new batteries in the battery holders.
After installing the new batteries, reverse steps 1 through 6.
3.3.1.2 Dry Contacts
The dry contacts terminal connectors (see Figure 3-2) are located on the rear panel of the alarm display unit. The four contacts on the input terminal block correspond to Critical, Major, Minor, and Audio Shut-off alarm inputs. The output terminal block contacts correspond to Critical, Major, Minor, and Audio Shut-off alarm outputs. These terminal blocks can be used to connect remote alarm indicators. When an alarm condition occurs, the corresponding relay is closed to connect a voltage on the input terminal to a remote alarming device on the output terminal. See Table 3-1 for the dry contact relay functional specification. Additionally, an audible alarm can be remotely disabled by connecting to the Shut-off Alarm contacts. Refer to Appendix A for the dry contact electrical specifications.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
3–5
Basic Operation
Figure 3-2: Dry Contact Terminal Connectors
A B
1 2 3 4 5 6 7 8 9 10
LJ-06572.AI7
A Input Term i nal Block B Output Terminal Block
Ext. Critical Alarm Critical Alarm Ext. Major Alarm Major Alarm Ext. Minor Alarm Minor Alarm Ext. Shut-off Alarm Shut-off Alarm Ground Ground
Table 3-1: Dry Contact Relay Functional Specification
Power Condition Cri tical Major Minor
On No alarm Open Open Open
Critical Closed Open Open Minor Open Open Closed Major Open Closed Open
Off Battery OK Op e n Open Clos e d
Batter y NOK Closed Closed Closed

3.3.2 AlphaServer 1000A System

Once the
AlphaServer
console displays test codes and initialization messages. When the startup procedure is complete, the following occurs:
The IP Platform console terminal emulation window displays the SRM console prompt
(>>>). The operator control pa ne l on t he front of t he
message "Model 5/500."
Boot the
Tru64 UNIX
boot at each processor window. The the
Tru64 UNIX
1000A system power is turned on, the screen on the IP Platform
system by typing boot at the console prompt. For duplex systems, type
prompt (#) appears.
Relay State
AlphaServer
AlphaServer
1000A system displays the
1000A system has booted successfully when
Refer to the
Tru64 UNIX
Refer to the operation of the
3–6
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
DIGITAL UNIX I n st a l l a t ion Guide
system.
AlphaServer 1000A Rackmount Owner's Guide
AlphaServer
1000A system.
for installation instructions on booting a
, for additional information on the

3.3.3 Modular Storage Shelf BA35x-Sx Subsystem

There may be up to eight StorageWorks building blocks (SBBs) on each modular storage shelf BA35x-Sx subsystem. The StorageWorks Buildi ng Bl ock (SBB) slots are num bere d 0 through 7 from right to left with the power supply SBB in slot 7. On the IP simplex system, the storage SBBs are in slots 0-6. On the duplex system, the available storage SBBs are in slots 0-5.
_____________________________ Note____________________________
The SCSI address for the SSB device is defined automatically by the SSB slot location.
______________________________________________________________
After power is supplied to the IP Platform, observe the status LEDs for the following successful indications:
On a power supply SBB, both green status LEDs should be on.
On a storage SBB, the green device activity LED is either on, flashing, or off. The amber device fault LED is off.
Additional information on the following modular storage shelf BA35x-Sx components can be found in the BA350 Modular Storage Shelf Subsystem User’s Guide.
Basic Operation
Component functions
Shelf status
Power unit status
Storage device status
StorageWorks building block SSB replacement procedures
Shelf replacement procedures
Power supplies
SCSI buses
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
3–7
Basic Operation

3.3.4 ISA Bus Expansion Chassis

The AlphaServer IP Platform supports a variety of voice/telephony options through the addition of an ISA bus expansion chassis. The ISA bus expansion cha ssis is configured wit h a 20-slot ISA backplane. The EISA to ISA bridge uses one slot and the remaining 19 slots are available for telephony options. The ISA bus expansion chassis has the following characteristics:
Conforms to ISA bus specifications
Contains an ON/Off power switch for removing power for servicing
Contains an alarm sensor module for monitoring
Chassis temperature
Chassis voltage
Cooling fan rotation
Connector for communication with the alarm control module installed in the AlphaServer 1000A system
Slide mounted to allow front access to all modules
430 W power supply to support maximum output voltages (to voice boards) and capacities as shown in the following table.
Voltage Amps*
570
-5 1.0 12 5.0
-12 1.0 * Provided that the maxim um
output power does not exceed the power supply rating.
Contains a load module to provide minimum power supply pre-load (4.2 A @ +5 V). This module may be rem ove d from t he ISA bus expansion chassis when the m i nim um power supply pre-load can be attained with the installed telephony options.
Each simplex system contains one ISA bus expansion chassis. Each duplex system contains two ISA bus expansion chassis. A connector on the alarm control module is dedicated to bringing in physical alarm signals from the ISA bus expansion chassis. Any of the alarm events listed above cause the alarm subsystem to generate an interrupt to the system software in order to update the alarm database and also send alarm signals to the alarm indicator panel for display.
3–8
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide

Reconfiguring the AlphaServer IP Platform

4.1 Introduction

In order to upgrade the AlphaSe rve r IP Pl at form or replace defective parts, you need to remove and install components within the IP Platform. These components are within the individual AlphaSe rve r 1000A system, ISA bus expansion chassis, and modular storage shelf BA35x-Sx subsystems. After you change any IP Platform component, you may want to verify or modify the system configuration.
This chapter lists the components of the IP Platform subsystem that may need to be removed or installed, and the procedure for viewing and modifying the subsystem configurations using the IP Platform console terminal SRM commands.
Before you attempt to install third-party devices inside your system unit, check with the third­party vendor to ensure that your system hardware and operating system software support the device.
____________________________ Caution __________________________
______________________________________________________________
4
Static electricity can damage electronic components. Use the antistatic wriststrap located in the inside rear cabinet door pocket. Additionally, use an antistatic mat when you handle internal c om ponent s.
____________________________ Achtung __________________________
Elektrostatische Entladungen könnten elektronische Komponenten beschädigen. Tragen Sie deshalb das Antistatikarmband, das sich in der Tasche an der Innenseite der hinteren Gehäuseklappe befindet. Außerdem sollten Sie bei der Berührung von internen Komponenten eine Antistatikmatte benutzen.
______________________________________________________________
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide 4–1
Reconfiguring the AlphaServer IP Platform

4.2 AlphaServer 1000A System Configurations

The components of the Al phaSe rver 1000A system that may need to be replaced or upgraded include:
Storage devices (DAT tape drive, hard disk drive, floppy drive, CD-ROM drive)
Memory modules
CPU motherboard
EISA modules
DExxx Ethernet controller *
Access I/O transmitter module (AT bus expansion kit) *
PCI modules
* KZPSA-BB SCSI controller (qty=2) (optional) * Alarm control module
Power supply
The KZPSA-BB PCI-to-SCSI adapter comes with its own utilities diskette that can be used to modify the adapter parameters. See the StorageWorks KZPSA PCI-to-SCSI Storage Adapter User's Guide for a complete description of the adapter.
After modifying the above c om ponent s, a nd be fore you boot t he Tru64 UNIX operating system, you can use the SRM console commands from the IP Platform console terminal to examine the system configurations of these components, and make modifications if necessary.
The EISA Configuration Utility (ECU) must be run whenever you add, remove, or move a n EISA or ISA card within the AlphaServer 1000A system. The ECU is a menu-based utility run from the SRM console that provides online help to guide you through the configuration process.
______________________________ Note ___________________________
Do not move the slot location of the Access I/O transmitter module. Changing the location of this module may result in configuration problems.
______________________________________________________________
Table 4-1 describes some of the basic SRM console commands used to verify system configurations on systems running the Tru64 UNIX operating system.
Table 4-1: SRM Console Configuration Commands
Command Description
show config show device show memory set
and
show
Displays the buses on the system and the devi ces f ound on t hose bus es. Displays the devices and controll er s on t he syst em . Displays the main memory configuration. Sets and displays the environm ent var iabl es .
Refer to the AlphaServe r 1000A R ack mount Owner's Guide for complete instructions on using the ECU and SRM console commands, or t ype
4–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
help
at the SRM prompt (>>>).
Reconfiguring the AlphaServer IP Platform

4.3 ISA Bus Expansion Chassis Configuration

The ISA bus expansion chassis provides a flexible capacity for adding voice modules of varying types based on products from Dialogic. See Section 1.4 for a complete list of available ISA bus expansion options.
Once the Dialogic voice modules are physically installed, you need to configure them by running the ECU from the IP Platform console terminal. Use the ECU to register the modules with the system hardware, and to reserve the addresses and interrupt request levels (IRQs) that are to be used by the modules. The ECU attempts to identify and resolve resource conflicts. The ECU may also be used to determine unused I/O ports, shared memory address, and IRQs.
In addition to the Dialogic voice modules, other components within the ISA bus expansion chassis include the:
Fan
Power supply
Alarm sensor module
Access I/O transceiver (AT bus expansion kit)
For a complete description of installing and configuring the voice-option modules, refer to the Dialogic documentation shipped with the option.
For a complete description of removing and replacing the fan or power supply, refer to the I- Bus 4820 User Manual that is shipped with your system.
Refer to Section 4.3.1 and Section 4.3.2 for complete descriptions of removing and replacing the alarm sensor module and the AT bus expansion kit.

4.3.1 Removing and Replacing the Alarm Sensor Module

The alarm sensor module is mounted in the drive bay area of the ISA bus expansion chassis. The 2T-IPSEN-AA alarm sensor module kit consists of an alarm sensor module, a cable to connect the alarm sensor module to the rear bulkhead, and a cable to connect the rear bulkhead to the alarm control module in the AlphaServer 1000A.
Perform the following procedure to remove the alarm sensor module:
1. Remove power from the ISA bus expansion chassis by pressing the On/Off switch on the front of the ISA bus expansion chassis.
2. Remove the screws that secure the ISA bus expansion chassis to the front rails and extend the ISA bus expansion chassis on the slides.
3. Remove the screws that secure t he t op c over a nd re move t he t op c over from t he ISA bus expansion chassis.
4. Disconnect the 6-pin bulkhead cable, the 4-pin power supply cable, and the 2-pin temperature sensor cable from the alarm sensor module.
5. Remove the four screws that secure the alarm sensor module to the standoffs and remove the alarm sensor module.
To replace the alarm sensor module, reverse steps 1 through 5 of the removal procedure.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 4–3
Reconfiguring the AlphaServer IP Platform

4.3.2 Removing and Replacing the AT Bus Expansion Kit

The 2T-VC220-IP AT bus expansion kit consists of the transmit module installed in the AlphaServer 1000A, the receive module installed in the ISA bus expansion chassis, and a 2­meter cable that connects the two modules.
Perform the following procedure to remove the receive module from the ISA bus expansion chassis:
1. Remove power from the ISA bus expansion chassis by pressing the On/Off switch on the front of the ISA bus expansion chassis.
2. Remove the screws that secure the ISA bus expansion chassis to the front rails and extend the ISA bus expansion chassis on the slides.
3. Remove the screws that secure t he t op c over a nd re move t he t op c over from t he ISA bus expansion chassis.
4. Disconnect the cable from the receive module.
5. Remove the hold-down bar from ac ross the t op of the m odule s in t he ISA bus expansion chassis.
6. Remove the screw that secures the receive module to the rear bulkhead of the ISA bus expansion chassis.
7. Remove the receive module from the ISA bus expansion chassis.
To replace the receive module in the ISA bus expansion chassis, reverse steps 1 through 7 of the removal procedure. Ensure that the jumpers on the new receive module are set to match the jumpers on the receive module being replaced.

4.4 Modular Storage Shelf BA35x-Sx Subsystem Configuration

The modular storage shelf BA35x-Sx contains the following components that may need to be removed and replaced:
StorageWorks building blocks (SBBs)
DWZZB-VW SCSI bus converter
H885-AA tri-link connector block
H879-AA SCSI terminator
Disk drives
Power supply
____________________________Important _________________________
Once a device has been initialized on a SCSI bus with a specific device address, moving the device to another bus or changing the device address can cause problems.
______________________________________________________________
Refer to the BA350 Modular Storage Shelf Subsystem User’s Guide for specific instructions on adding and removing StorageWorks components, and setting the correct device addresses.
4–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Reconfiguring the AlphaServer IP Platform

4.5 Alarm Indicator Panel Configuration

The alarm indicator panel provides programmable visual and audible alarm indicators for the AlphaServer IP Platform. The alarm indicator panel consists of a metal frame, graphics panel(s), and alarm indicator module(s). A cable connects the alarm indicator module to the alarm control module that is installed on the AlphaServer 1000A PCI bus.

4.5.1 Removing and Replacing the Alarm Indicator Module

The alarm indicator module is mounted inside the alarm indicator panel. Perform the following procedure to replace an alarm indicator module:
1. Power down the AlphaServer 1000A system.
2. At the front of the cabinet, remove the four screws that secure the alarm indicator panel frame to the front rails.
3. Disconnect the miniature 26-pin cable(s) from the connector(s) on the rear of the alarm indicator panel(s).
4. If attached, disconnect any cables connected to the dry contact terminal blocks.
5. On the rear of the alarm indicator panel that contains the alarm indicator module to be replaced, remove the two screws that secure the miniature 26-pin connector to the rear cover.
6. Remove the three scre ws from the top e dge and t he thre e screws from the bot tom e dge of the alarm indicator panel frame that secure the alarm indicator panel rear cover.
7. Remove the alarm indicator panel rear cover.
8. Remove the four screws that secure the alarm indicator module to the alarm indicator panel frame.
To replace the alarm indicator module, reverse steps 1 through 8 of the removal procedure.
_____________________________ Note____________________________
The alarm indicator panel should not be permanently removed without de­configuring it in the Intelligent Peripheral Fault Manager (IPFM) config file. Refer to the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation
and User's Guide.
______________________________________________________________
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 4–5
is some white text.

5.1 Introduction

This chapter describes procedures for resolving problems with the components of the AlphaServer Intelligent Peripheral (IP) Platform. If the subsystem troubleshooting is discussed in another manual, a reference is provided to that documentation.
Before servicing the system, be aware of any service agreement that exists for your system. The agreement helps determine the level of maintenance for self-maintenance customers.
To correct a problem, locate the troubleshooting section for that component and refer to the appropriate documentation. If you cannot correct the problem, report it to your service representative.
___________________________ WARNING _________________________
______________________________________________________________

System Troubleshooting

Only a qualified service person should install the system. A qualified service person is an individual who has the technical training and experience to be aware of the:
Hazards to which they are exposed in performing a task
Measures to minimize the danger to themselves or other persons
A qualified service person need not be a Compaq service representative.
5
___________________________VORSICHT _________________________
Das System darf nur von qualifizierten Fachleuten installiert werden. Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult sind und über die nötige E r f a hr ung verfügen, um :
die Gef a hr e n zu erkenne n, denen sie be i der Ausführung de r Arbeit ausgesetzt sein könnten
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst
und für andere Personen zu ergreifen. Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des Compaq­Kundendienstes.
______________________________________________________________
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide 5–1
System Troubleshooting

5.2 AlphaServer 1000A Subsystem

The AlphaServer 1000A Rackmount Owner's Guide provides the instructions on completing the following tasks or resolving these particular problems:
Confirming that EISA modules or memory modules are properly configured
Running a diagnostic test of the entire system, showing its status, or terminating the testing
Checking the startup displa y when you t urn on the system
What to do if:
The power supply has shut down
Startup tests do not complete
The system cannot boot the operating system
The operating system reports errors, is hung, or crashes
The system cannot access a mass storage device
Storage devices are missing from the show device display
The system indicates network problems, an EISA module is not configured, or a PCI module is unseen by the system
The monitor or the te rm ina l is not working
The keyboard and mouse are not working
The system repeatedly shuts down after 10 seconds
The system does not see or cannot access RAID drives
The Flash ROM is corrupted and the system cannot access console mode

5.3 Alarm Indicator Panel

The alarm indicator panel (see Figure 3-1) uses visual and audio alarm indicators to display the status of the IP Platform, including the ISA bus expansion chassis and the -48 Vdc power inverter or user alarm inputs. The alarm indicator panel displays alarms as long as it can communicate with the alarm control module in the AlphaServer 1000A, or until its backup batteries become fully discharged.
Refer to Section 3.3.1 for a description of the alarm indicator panel alarms and status displays. Refer to Section 3.3.1.1 for the procedure for replacing the batteries in the alarm indicator panel.
5–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide

5.4 ISA Bus Expansion Chassis

The ISA bus expansion chassis contains alarm sensors that detect fault conditions and send the information to the alarm control module in the AlphaServer 1000A system chassis.
For a complete description of alarm sensor interaction with the IP Fault Manager software, see the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide.
The status of the Dialogic voice modules is handled at the application level and not by the IP Fault Manager software.

5.5 Modular Storage Shelf BA35x-Sx Subsystem

The modular storage shelf BA35x-Sx uses the LE Ds of its StorageWorks buil ding bl oc ks (SBBs) to indicate problems within the power unit, storage devices, and StorageWorks shelf. Depending upon the problem, these displays can be flashing, on, or off. The BA350 Modular Storage Shelf Subsystem User’s Guide provides instructions on how to interpret these displays.

5.6 AlphaServer IP Power Controllers

If the power controllers do not function properly, perform the following steps:
System Troubleshooting
1. Prior to turning on the circuit breakers for the 120 Vac or 250 Vac controllers, ensure that the neon indicator is on, indicating that an ac voltage is present. The -48 Vdc controller does not have an indicator for voltage. It should be connected to the -48 Vdc battery/power source prior to turning on the circuit breakers.
2. Check that the circuit breakers are on for each of the power controllers installed.
3. Refer to the DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac P owe r Inverte r Owner’s Guide for more troubleshooting information on the -48 Vdc controller.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
5–3
is some white text.
AlphaServer IP Platform Specifications

A.1 Physical Dimensions

Table A-1 contains the physical dimensions for the AlphaServer Intelligent Peripheral (IP) Platform.
Table A-1: Physical Dimensions
Dimension S pecification
Depth 96.52 cm (38.0 in.) i ncl uding door s Width 55.88 cm (22.0 in.) Height 220.01 cm (86.62 in.) including cable tr ough Height 204.77 cm (80.62 in.) without cabl e t r ough Weight 385.56 kg (850 lbs) for ful l y l oaded duplex s yst em Front aisle 76.2 cm (30.0 in.) minimum cl earance Rear aisle 60.96 cm (24.0 in.) m i nim um cl earance
A

A.2 Electrical Specifications

Table A-2 contains the electrical specifications for each IP Platform power controller.
Table A-2: Electrical Specifications for Each Power Controller
Specification Range
Input voltage 120 Vac or
Frequency (ac only) 50-60 Hz Input current maxim um 8.0 A at 120 Vac or
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide A–1
250 Vac or
-48 Vdc
4.0 A at 250 Vac or 50 A at -48 Vdc
AlphaServer IP Platform Specifications

A.3 System Environmental Specifications

Table A-3 contains the environmental specifications for the AlphaServer IP Platform.
Table A-3: Environmental Specifications
Operating/Storage Conditions
Temperature range 10°C to 40°C (50°F to 104°F) Barometric pressur e 760 mm (29.92 in. Hg) Relative humidity 20% to 80% (noncondensing) Minimum dew point 2°C (36°F) Maximum altitude 2,438 m (8,000 ft) Maximum wet bulb tem per at ure 28°C (82°F)
Nonoperating Conditi ons
Temperature range -40°C to 66°C (-40°F to 151°F) Relative humidity 20% to 85% (noncondensing) Maximum altitude 4,877 m (16,000 ft)
1
The maximum allowable operati ng t em perat ur e above 2, 438 m ( 8, 000 ft ) i s r educed
1.8°C/1,000 m (1.0°F/ 1, 000 f t ) .
1
1
A–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide

A.4 Dry Contact Specifications

Table A-4 contains the rating, input, and output specifications for the dry contact terminals.
Table A-4: Dry Contact Specifications
Material and Ratings
Contact material Gold-clad silver Rating (resistive) Maximum switching power 60 W, 125 VA Maximum switching vol t age 220 Vdc, 250 Vac Maximum switching cur r ent 2 A DC, 2 A AC Maximum carrying curr ent 3 A DC, 3 A AC
Input Specifi cat i ons
Type Relay coil Rated input voltage 5 Vdc nominal Maximum input 10 Vdc at 50 C Pick-up voltage 3.5 Vdc maximum Drop-out voltage 0.5 Vdc minimum Coil resistance 125 ohms, +/- 10%
Output Specifi cations
Contact rating (switching) Voltage 220 Vdc, 250 Vac (maximum) Curren t 2 A DC, 2 A AC (maxim u m ) UL/CSA 0.6 A, 125 Vac
Coil rating 200 mW typicall y
AlphaServer IP Platform Specifications
0.6 A, 110 Vdc
2.0 A, 30 Vdc
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
A–3
AlphaServer IP Platform Specifications
A.5 Central Office Compatibility
The AlphaServer IP Platform is intended for deployment in telecommunications central office (CO) environments, and is compatible with some of Bellcore's Network Equipment­Building Systems (NEBS) specifications TR-NWT-000063.
Some of the central office compatible (conforming) hardware requirements supported by the AlphaServer IP Platform are:
Simplex or duplex system housed within a single electronic equipment cabinet.
Cabinet of welded steel construction has locking front and rear doors, bolt-down provisions at the cabinet ba se and t op (for use onl y when a -48 Vdc power i nve rte r i s installed in the cabinet), four-wheel rugged castor base, four-point leveling, and cable egress from top or bottom of the ca bi net .
Integral cable trough attached to the top-rear half of the cabinet, and for larger systems, forms a continuous cable trough a l ong the c abi ne t t op-re ar.
120 Vac, 250 Vac, and -48 Vdc dual-feed power models are available for the duplex system.
Weight is 385.56 kg (850 lbs).
______________________________ Note ____________________________
Floor loading is approximately 38.56 kg (85 lbs) per square foot according to NEBS weight calculation rules. Maximum allowed is 52.16 kg (115 lbs) per square foot.
_______________________________________________________________
Operating relative humidity of 20% to 80%.
Acoustic noise is less than 65 dBA.
Designed to meet earthquake Zone 2.
Meets FCC Class A specifications.
Meets UL and other international safety specifications.
NEBS nonconforming features are:
Cabinet depth is 96.52 c m (38 i n. )
Printer and terminal are table-top mounted.
Fire testing not performed.
Convenience outlets not provided.
Earthquake testing for Z one s 2, 3, a nd 4 not pe rform ed.
The AlphaServer IP Platform simplex and duplex systems are contained within one single bay 177.8 cm (70 in.) panel space cabinet (except for console terminal).
A–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide

B.1 Alarm Input Wiring Diagram

The following diagram of the Intelligent Peripheral (IP) duplex platform displays the alarm input wiring connections between the ISA bus expansion chassis, the AlphaServer 1000A processors, and the alarm indicator panel.
Figure B-1: Alarm Input Wiring Diagram
2
3
5
4
6
B
Alarm Input Wiring
AlphaServer 1000A
1
ISA
7
Alarm control module ins tal l ed i n
AlphaServer
the
-48 Vdc power inverter
D-sub 25-pin connector
Inverter alarm cable
Alarm indicator panel
8
1000A system
9
Alarm indicator panel cable
Alarm sensor module in t he ISA bus expansion chassis
D-sub 9-pin connector
ISA bus expansion chassis alarm cabl e
ML014035
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide B–1
Alarm Input Wiring

B.2 Wiring User Alarm Inputs

This section provides information for wiring user TTL signal alarm inputs to the 8-pin MJ connector on the alarm control module installed in the AlphaServer 1000A system.
Figure B-2 shows the 8-pin MJ connector on the alarm control module that is used for connecting user alarm inputs.
Figure B-2: Alarm Control Module 8-Pin MJ Connector
1
Table B–1 provides a pinout listing of the pins on the alarm control module 8-pin MJ connector. This table should be used to determine the correct wiring required for user alarm inputs.
8
ML014036
Table B–1: Al arm Control M odule 8-Pin MJ Connector Pinout
Pin No. Signal
1 Inverter Fail or user input 1 Retur n 2 Inverter Fail or user input 1 3 Inverter Minor or user i nput 2 Ret urn 4 Inverter Minor or user i nput 2 5 Inverter Major or user i nput 3 Ret urn 6 Inverter Major or user i nput 3 7 Not used 8 Not used
B–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Field Wiring the -48 Vdc Power Inverter

C.1 Field Wiring the -48 Vdc Power Controllers

The following sections describe how to field wire the -48 Vdc power controllers.
___________________________ WARNING _________________________
The person(s) installing the system should be aware of the 1993 NEC (National Electrical Code) requirements for data processing equipment installation, Article 645, 645-2. Failure to follow these requirements could result in personal injury and damage to the equipment. Only a qualified service person should install the system. A qualified service person is an individual who has the technical training and experience to be aware of the:
Hazards to which they are exposed in performing a task
Measures to minimize the danger to themselves or other persons
A qualified service person need not be a Compaq service representative.
______________________________________________________________
C
___________________________VORSICHT _________________________
Die Personen, die das System installieren, sollten die Voraussetzungen de s 1993 NEC (National Electrical Code) zur Installation von Datenverarbeitungsgeräten, Artikel 645, 645-2, kennen. Mi ßachtung dieser Voraussetz ung e n kö nnte zu Personen- und Geräteschade n führen. Das System darf nur von qualifizierten Fachleuten installiert werden. Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult sind und über die nötige E r f a hr ung verfügen, um :
die Gef a hr e n zu erkenne n, denen sie be i der Ausführung de r Arbeit ausgesetzt sein könnten
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst
und für andere Personen zu ergreifen. Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des Compaq­Kundendienstes.
______________________________________________________________
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide C–1
Field Wiring the -48 Vdc Power Inverter

C.1.1 Installing Suitable Field Wiring

The following subsections describe how to install suitable field wiring.
C.1.1.1 Field Wiring Recommendations
Table C–1 lists the field wiring recommendations for each side of the -48 Vdc power controller. The -48 Vdc power controller has dual power feeds.
Table C–1: F ield Wi ring Recommendations for Each Power Feed
Input Power Requi r em e nt -48 Vdc Power Contr oller
Input voltage -48 Vdc Input current 50 A max Inrush peak 6 A max soft start limited
Recommended wire: Wire should be U/L recognized and CSA certified for 105°C (221°F), with insulation rated for 600 Vac. Each of the 3-wire conductors should be a minimum of 6 AWG stranded.
____________________________WARNING_________________________
High energy hazard. Proper precautions required.
______________________________________________________________
___________________________ VORSICHT ________________________
Hochspannungsgefahr. Geeignete Vorsichtsmaßnahmen sind notwendig.
______________________________________________________________
C.1.1.2 Installing the Wiring
1. Strip the wire insulation to approximately 1.27 cm (.50 in.).
2. Insert the wire into the terminal block as follows: a. Observe the wire color/polarity
– – –
b. Torque the #10-32 compression screws to 40 to 45 inc h-pounds.
______________________________ Note ___________________________
Refer to the DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac P owe r Inverte r Owner’s Guide for information on powering up and testing the -48 Vdc inverter.
______________________________________________________________
Black: -48 Vdc White: +48 Vdc Green/yellow: Ground
C–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Duplex System

D.1 Introduction

This appendix contains diagrams of the AlphaServer Intelligent Peripheral (IP) Platform duplex, ac and dc, systems.
D
Diagrams
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide D–1
AlphaServer IP Platform Duplex System Diagrams

D.2 AlphaServer IP Platform Duplex AC System

This section contains the front, side, and rear views of the duplex ac system.
Figure D–1: IP Platform Duplex AC System Front and Side View
1
2
3
4
5
Front View
Alarm indicator panels
BA35x-Sx modular storage shelf (opt ional )
ISA bus expansion chassis
Side View
AlphaServer
H7600 power controller
1000A
ML014018
D–2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Duplex System Diagrams
Figure D–2: IP Platform Duplex AC System Rear View
1
2
3
4
5
Back View
ML014028
Alarm indicator panels AlphaServer 1000A BA35x-Sx modular storage shelf (opti onal ) H7600 power controll er ISA bus expansion chassis
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
D–3
AlphaServer IP Platform Duplex System Diagrams

D.3 AlphaServer IP Platform Duplex DC System

This section contains the front, side, and rear views of the duplex dc system.
Figure D–3: IP Platform Duplex DC System Front and Side View
1
2
3
4
MX ALARM CARDMX ALARM CARD
AC POWERAC POWER
Front View
Alarm indicator panels
BA35x-Sx modular storage shelf (opt ional )
ISA bus expansion chassis
5
Side View
AlphaServer
-48 Vdc power controller
1000A
ML014017
D–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Duplex System Diagrams
Figure D–4: IP Platform Du plex DC System Rear View
1
2
3
4
_
+
_
+
Back View
_
_
5
+
+
ML014027
Alarm indicator panels AlphaServer 1000A BA35x-Sx modular storage shelf (opti onal ) -48 Vdc power controll er ISA bus expansion chassis
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
D–5
is some white text.
AlphaServer IP Platform Simplex System

E.1 Introduction

This appendix contains diagrams of the AlphaServer Intelligent Peripheral (IP) Platform simplex, ac and dc, systems.
E
Diagrams
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide E- 1
AlphaServer IP Platform Simplex System Diagrams

E.2 AlphaServer IP Platform Simplex AC System

This section contains the front, side, and rear views of the simplex ac system.
Figure E–1: IP Platform Simplex AC System Front and Side View
1
2
3
4
5
Front View
Alarm indicator panel
BA35x-Sx modular storage shelf (opt ional )
ISA bus expansion chassis
Side View
AlphaServer
H7600 power controller
1000A
ML014022
E-2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Simplex System Diagrams
Figure E–2: IP Platform Simplex AC System Rear View
1
2
3
4
5
Back View
ML014032
Alarm indicator panel AlphaServer 1000A BA35x-Sx modular storage shelf (opti onal ) H7600 power controll er ISA bus expansion chassis
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
E-3
AlphaServer IP Platform Simplex System Diagrams

E.3 AlphaServer IP Platform Simplex DC System

This section contains the front, side, and rear views of the simplex dc system.
Figure E–3: IP Platform Simplex DC System Front and Side View
1
2
3
4
MX ALARM CARD
AC POWER
5
Front View
Alarm indicator panel
BA35x-Sx modular storage shelf (opt ional )
ISA bus expansion chassis
Side View
AlphaServer
-48 Vdc power controller
1000A
ML014021
E-4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
AlphaServer IP Platform Simplex System Diagrams
Figure E–4: IP Platform Simplex DC System Rear View
1
2
3
4
_
+
_
+
Back View
_
_
5
+
+
ML014031
Alarm indicator panel AlphaServer 1000A BA35x-Sx modular storage shelf (opti onal ) -48 Vdc power controll er ISA bus expansion chassis
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
E-5
is some white text.

Glossary

10Base-T Ethern et network
The IEEE standard 802.3-compliant Ethernet products used for local distribution of data. These networking products characteristically use twisted-pair cable.
agent
A background task running on the object being managed. The agent responds to requests for information by the network management station (NMS). The agent i s re sponsi bl e for performing get and set operations, for generating the appropriate traps, and for controlling access.
AlphaServer system
Compaq’s new generation of server systems based on the Alpha 64-bit computing architecture.
ARC
Advanced RISC Computing (ARC) is the user interface to the console firmware for operating systems that expect firmware compliance with the Windows NT Portable Boot Loader Specification.
availability
The amount of scheduled time that a computing system provides application service during the year. Availability is typically measured as a percentage of up time per year.
backbone
A core network (usually high speed) to which multiple local area networks (LANs) are connected using bridges or routers and over which internetwork traffic can pass.
backplane
The main module (board or panel) that connects all of the modules in a computer system.
boot
Short for bootstrap. To load an operating system into memory.
boot device
The device from which the system bootstrap software is acquired.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide Gl ossar y- 1
Glossary
bus
A collection of many transmission lines or wires. The bus interconnects computer system components, providing a communications path for addresses, data, and control information or external terminals and systems in a communications network.
cache
A small, high-speed memory placed between slower main memory and the processor. A cache increases effective memory transfer rates and processor speed. It contains copies of data recently used by the processor and fetches several bytes of data from memory in anticipation that the processor will access the next sequential series of bytes.
CD-ROM
Compact disc read-only memory. The optical removable media used in a compact disc reader.
central pro cessing unit (CPU)
The unit of the computer that is responsible for interpreting and executing instructions.
command line interface
One of two interfaces in the AlphaServer operator interface. The command line interface supports OpenVMS and Tru64 UNIX operating systems. It allows you to configure and boot the operating system.
console mode
The state in which the system and the console terminal operate under the control of the console program.
console subsystem
The subsystem that provides the user interface for a computer system when the operating system is not running.
console terminal
The terminal connected to the console subsystem. It is used to start the system and to direct activities between the user and the computer system.
CSU
Channel service unit. A device that terminates a digital channel on a customer's premises. It contains certain line conditioning and equalization functions, and responds to loopback commands sent from the central office.
daughterboard
A PC module that attaches to the component side of the host module.
diagnostic program
A program that finds and corrects problems with a computer system.
Glossary-2
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Glossary
dry contacts
An electromagnetic device for remote or automatic control that is activated by variation in conditions of an electric circuit and that in turn operates other devices (such as switches) in the same or a different circuit.
DSX-1
Digital Signal Cross-connect Level 1. Any equipment that supports a set of parameters for cross-connecting DS-1 (either T-1 or E-1) lines.
E-1
Another name given to the CEPT (Conference of European Postal and Telecommunications Administrations) digital telephony format. E-1 is a digital transmission channel that carries data at the rate of 2.048 Mb/s (DS-1 level).
ECC
Error correction code. The code and algorithms used by logic to facilitate error detection and correction.
EISA bus
Extended Industry Standard Architecture bus. A 32-bit industry-standard I/O bus used primarily in high-end PCs and servers.
EISA Configuration Utility (ECU)
A feature of the EISA bus that helps you select a conflict- free system configuration and perform other system services. The ECU must be run whenever you change, add, or remove an EISA or ISA controller.
environment variables
The global data structures that can be accessed from console mode. The setting of these data structures determines how a system powers up, boots the operating system, and operates.
Ethernet
The IEEE 802.3 standard local area network.
firmware
The software code stored in hardware .
initialization
The sequence of steps that prepare the computer system to start. Initialization occurs after a system has been powered up.
Interrup t request lines (IRQs)
The bus signals that connect an EISA or ISA module (for example, a disk controller) to the system so that the module can get the system's attention by means of an interrupt.
ISA
Industry Standard Architecture. An 8-bit or 16-bit industry-standard I/O bus, widely used in personal computer products. The E ISA bus is a superset of the ISA bus.
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Glossary-3
Glossary
LAN
Local area network. A high-speed network that supports computers connected over limited distances.
light-emitting diode (LED)
An indicator of status on an IP subsystem.
MAC (media access control) ad dress
A unique 48-bit binary number (usually represented as a 12-digit hexadecimal number) encoded in a device's circuitry to identify it on a local area network.
Maintenance Operations Protocol (MOP) session
A logical connection using the Maintenance Operations Protocol (MOP).
mass storage devi ce
An input/output device on which data is stored. Typical mass storage devices include disks, magnetic tapes, and CD-ROM.
module
A hardware or software component that is a self-contained system interacting with a larger system. Hardware modules are often made to plug into a main system.
network
A collection of computers, terminals, and other devices together with the hardware and software that enables them to exchange data and share resources over either short or long distances.
network man agement station (NMS)
A PC or workstation equipped with an Ethernet, FDDI, or Token Ring network module an d HUBwatch software that enables it to communicate with and manage network modules.
network modules
Modular devices that provide network connectivity or services that can be installed in a DEChub backplane or used as standalone devices. Network modules include repeaters, concentrators, bridges, brouters, access servers, switches, and SNMP agent s.
PCI
Peripheral component interconnect. An industry-standard expansion I/O bus that is the preferred bus for high-performance I/O options. PCI is available in a 32-bit version and a 64­bit version.
PCI-to-EISA bridge
The capability to transfer commonly available EISA and ISA options to the PCI bus.
protocol
A formal set of rules governing the format, timing, sequencing, and error control of exchanged messages on a data network.
Glossary-4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Glossary
RAID
Redundant arrays of independent disks. A technique that organizes disk data to improve performance and reliability. RAID has three attributes: it is a set of physical disks viewed by the user as a single logical device; the user's data is distributed across the physical set of drives in a defined manner; and redundant disk capacity is added so that the user's data can be recovered even if a drive fails.
redundant
Pertaining to duplicate or extra computing components that protect a computing system from failure.
reliability
The probability that a device or system will not fail to perform its intended functions during a specified time.
repeater
A level 1 hardware device that restores signal amplitude, waveform, and timing of signals before transmission to another ne t work segment .
SBB
StorageWorks building block. The basic bui ldi ng bl ock of t he StorageWorks product l ine . Any device conforming to shelf mechanical and electrical standards installed in either a 3½­inch or 5¼-inch carrier is considered to be an SBB, whether it be a storage device, a power supply, or other device.
SCSI
Small Computer Systems Interface. An ANSI-standard interface for connecting disks and other peripheral devices to computer systems. Some devices are supported under the SCSI-1 specification; others are supported under the SCSI-2 specification.
server
A network node or specialized device that provides and manages access to shared network resources, such as hard disks, printers, a nd software.
SIMM
Single in-line mem ory m odule . A plug-i n modul e tha t has RAM chips on one side, a nd a n edge connector that matches a socket on the system module.
Simple Network Management Protocol (SNMP)
A high-level, standards-based protocol for network management, usually used in TCP/IP (Transmission Control Protocol/Inte rne t Protoc ol ) net works.
SNMP agent
An entity in a hardware device that executes SNMP request s.
SRM
The user interface to console firmware for operating systems that expect firmware compliance with the Alpha System Reference Manual (SRM).
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
Glossary-5
Glossary
StorageWorks
Compaq's modular storage subsystem (MSS), which i s the core technology of the Alpha SCSI-2 mass storage solution. StorageWorks consists of a family of low-cost mass storage products that can be configured to meet current and future storage needs.
system disk
The device on which the operating system resides.
T-1
The digital telephony format used in North America. T-1 is a digital transmission link handling 24 voice conversations on two pairs of twisted wires.
Telnet
The TCP/IP standard protocol for remote terminal connections. Using Telnet, a user at one site can connect to a timesharing system at another site as if the user's terminal is connected directly to the remote machine.
terminal server
A module that allows a terminal to connect to a network node.
ThinWire
Ethernet cabling and technology used for local distribution of data communications. ThinWire cabling is thinner than thick wire cabling.
Transmission Control Protocol (TCP)
The transport protocol offering a connection-oriented transport service in the Internet suite of protocols.
workgroup
A configuration that consists of a relatively small number of devices attached to a LAN that is isolated from the extended LAN backbone by a bridge or router.
Glossary-6
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide
A
Alarm indicator module
replacing, 4–5
Alarm indicator panel
diagram, 3–3 replacing batteries , 3–4
troubleshooting, 5–2 Alarm input wiring diagram , B–1 Alarm sensor module
replacing, 4–3 Alarm subsystem, 1–4 AlphaServer 1000A system
components, 4–2
optional hardware, 1–7
overview, 1–6
power-up, 3–1
reconfiguring, 4–2
required hardware, 1–7
troubleshooting, 5–2 AT bus expansion kit
replacing, 4–4
B
BA35x-Sx. See Modular storage
shelf
D
Dialogic modules, 1–9 Dry contact specifications, A–3 Dry contacts, 3–5 Duplex system. See IP Platform
ac system diagrams, D–2
dc system diagrams, D–4
duplex system, 1–2
E
E-1
120-ohm network connections,
2–6
120-ohm pin designations , 2–6

Index

75-ohm network connections,
2–6
75-ohm pin designations , 2–6
EISA Configuration Utility (ECU),
4–2 Electrical specifications, A–1 Environmental specifi cati ons , A–2 External hardware options, 1–11
F
Factory installed
hardware, 2–1
software, 1–3 Fault management, 1–3 Features
alarm subsystem, 1–4
corporation and industry
standards, 1–5 maintainability, 1–4 reliability, 1–4 system security, 1–6 upgrading, 1–5 user interfaces, 1–4
H
Hardware
factory installed, 2–1
Hardware setup, 2–3
connecting network hardware,
2–4 installing the plat f orm , 2–4
I
Installation
hardware installation, 2–3 preinstallati on consi derat i ons,
2–2 site preparation, 2–2
Intelligent Peripheral Platform. See
IP Platform
Interfaces
telecomminications, 1–5 user, 1–4
AlphaServer Int elligent Peripheral Platfor m Hardware Owner's G uide Index- 1
Index
IP Platform
duplex ac system diagrams , D–
2
duplex dc system diagrams , D–
4 duplex system, 1–2 electrical specificati ons, A–1 environmental specifi cat i ons,
A–2 installing, 2–4 overview, 1–1 physical dimensions, A–1 power controller, 2–8 power-up, 3–1 reconfiguration, 4–1 simplex ac system diagrams, E-
2 simplex dc system diagrams, E-
4 simplex system, 1–2 troubleshooting, 5–1
ISA bus expansion chassis
components, 4–3 hardware, 1–9 overview, 1–8 reconfiguring, 4–3 troubleshooting, 5–3
L
Loop-start network
25-pin designations, 2–7 50-pin designations, 2–8 hardware connections, 2–7
M
Modular storage shelf
components, 4–4 hardware, 1–8 operation, 3–7 overview, 1–8 reconfiguring, 4–4 status LEDs, 3–7 troubleshooting, 5–3
N
NEBS compatibility, A–4
P
Physical dimensions , A–1
Power controller subsyst em
dc field wiring, C–1 hardware, 1–10 overview, 1–10 troubleshooting, 5–3
R
Replacing alarm indicator m odule,
4–5
Replacing alarm indicator panel
batteries, 3–4 Replacing alarm sensor modul e, 4–3 Replacing AT bus expansion kit, 4–4
S
Simplex system. See IP Platform
ac system diagrams, E-2 dc system diagrams, E-4
simplex system, 1–2 Site preparation, 2–2 Software
factory installed, 1–3 SRM console commands, 4–2 Standards
electromagnetic, 1–5
safety, 1–5
telecommunications , 1–5 StorageWorks. See Modular stor age
shelf
System security, 1–6
T
T-1
cable length, 2–2
network connections, 2–5
pin designations, 2–5 Telecommunications interf aces, 1–5 Troubleshooting
alarm indicator panel , 5–2
AlphaServer 1000A, 5–2
IP platform, 5–1
ISA bus expansion chassis, 5–3
modular storage shelf, 5–3
power controller
subsystem, 5–3
U
User alarm input wiring, B–2 User interfaces, 1–4
Index-2
DIGITAL AlphaServer Intelligent Per ipher al Plat form Hardwar e Owner’s Guide