Comnet FDX60M1A User Manual

INSTALLATION AND OPERATION MANUAL
FDX60(M)(S)(-M)
SINGLE OR DUAL RS232/RS422/RS485(2/4W) DATA TRANSCEIVER
transmission of simplex or duplex EIA RS232/RS422/RS485 (2W/4W) data
signals over one or two optical fibers. The transceivers are transparent to data
encoding allowing for broad-range compatibility. Models within this series are
available for use with multimode or single mode optical fiber.
Each transceiver incorporates a bi-color (Red/Green) indicating LED for
monitoring proper system operation. See Figure 8 on Page 6 for LED Indicator
explanations.
The FDX60(M)(S)(-M) has a built-in fiber link test feature that allows for the
testing of the fiber. See Figure 13 on Page 8 for an explanation of the Loop
Back Test Mode.
The FDX60(M)(S) may be directly plugged into the ComNet Rack (Part C1) or
they can operate as standalone modules. The FDX60(M)(S)-M has a small
footprint and is designed for surface mounting. See Figures A and B on
Page 9 for mounting instructions.
See Figures 1 – 13 for complete installation details.
INS_FDX60_REV–
04/23/10
PAGE 1
INSTALLATION AND OPERATION MANUAL FDX60(M)(S)(-M)
FIGURE 1 – FDX60 1 FIBER TRANSCEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPE/RED
FIGURE 2 – FDX60 1 FIBER TRANSCEIVER
REAR PANELFRONT PANEL
TECH SUPPORT: 1.888.678.9427
NOTE: Remove Electrical Connector for Rack Mount Units
INS_FDX60_REV–
04/23/10
PAGE 2
INSTALLATION AND OPERATION MANUAL FDX60(M)(S)(-M)
FIGURE 3 – FDX60 2 FIBER TRANSCEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPE/RED
FIGURE 4 – FDX60 2 FIBER TRANSCEIVER
REAR PANELFRONT PANEL
TECH SUPPORT: 1.888.678.9427
NOTE: Remove Electrical Connector for Rack Mount Units
INS_FDX60_REV–
04/23/10
PAGE 3
INSTALLATION AND OPERATION MANUAL FDX60(M)(S)(-M)
FIGURE 5 – FDX60-M 1 FIBER TRANSCEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE
STRIPE/RED
FIGURE 6 – FDX60-M 1 FIBER TRANSCEIVER
REAR PANELFRONT PANEL
NOTE: Remove Electrical Connector for Rack Mount Units
TECH SUPPORT: 1.888.678.9427
INS_FDX60_REV–
04/23/10
PAGE 4
INSTALLATION AND OPERATION MANUAL FDX60(M)(S)(-M)
FIGURE 7 – FDX60-M 2 FIBER TRANSCEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE
STRIPE/RED
FIGURE 8 – FDX60-M 2 FIBER TRANSCEIVER
REAR PANELFRONT PANEL
NOTE: Remove Electrical Connector for Rack Mount Units
TECH SUPPORT: 1.888.678.9427
INS_FDX60_REV–
04/23/10
PAGE 5
INSTALLATION AND OPERATION MANUAL FDX60(M)(S)(-M)
FIGURE 9 – LED INDICATORS
LINK DATA (TX/RX) LOOP BACK (Test Mode) POWER
GREEN Unit In Sync Activity Fiber Link Connections are Correct Unit Powered Up
RED Unit Not In Sync No Acvitiy Fiber Link Issue Exists (Head End)
OFF No Optical Link Fiber Link Issue Exists (Far End);
OR Test Mode is Off
Unit Powered Down
FIGURE 10 – SWITCH POSITIONS
Switch
Located on front panel in full size modules and on back on small size modules.
The first two switches set the data type, the third toggles Loop Back Test Mode.
RS232 Data
1 2 3*
RS485 2-Wire,
Sensornet Data
1 2 3*
Loop Back
Test
1 2 3*
RS422, Bi-Phase or
Manchester Data
1 2 3*
RS485
4-Wire Data
1 2 3*
TECH SUPPORT: 1.888.678.9427
* Loop Back Test Mode
(see Page 8)
INS_FDX60_REV–
04/23/10
PAGE 6
INSTALLATION AND OPERATION MANUAL FDX60(M)(S)(-M)
FIGURE 11 – DATA CONNECTIONS
– Data In/Out + Data In/Out – Data Out + Data Out RS232 Out RS232 In GND
FIGURE 12 – DATA SETTINGS
RS232
RS422
Bi-phase or Manchester
2-Wire RS485
Customer
Equipment
Data Transmit
Data Receive
Signal Ground
Data Out (+)
Data Out (–)
Data In (+)
Data In (–)
Data Out (+)
Data Out (–)
Data (A)
Data (B)
FDX60
Signal – Pin
IN – 2
OUT – 3
GND – 1
FDX60
Signal – Pin
+IN/OUT – 6
–IN/OUT – 7
+OUT – 4
–OUT – 5
FDX60
Signal – Pin
+IN/OUT – 6
–IN/OUT – 7
FDX60
Signal – Pin
+IN/OUT – 6
–IN/OUT – 7
FDX60
Signal – Pin
OUT – 3
IN – 2
GND – 1
FDX60
Signal – Pin
+OUT – 4
–OUT – 5
+IN/OUT – 6
–IN/OUT – 7
FDX60
Signal – Pin
+OUT – 4
–OUT – 5
FDX60
Signal – Pin
+IN/OUT – 6
–IN/OUT – 7
Customer
Equipment
Data Receive
Data Transmit
Signal Ground
Data In (+)
Data In (–)
Data Out (+)
Data Out (–)
Data In (+)
Data In (–)
Data (A)
Data (B)
4-Wire RS485
TECH SUPPORT: 1.888.678.9427
Data Out (A)
Data Out (B)
Data In (A)
Data In (B)
FDX60
Signal – Pin
+IN/OUT – 6
–IN/OUT – 7
+OUT – 4
–OUT – 5
FDX60
Signal – Pin
+OUT – 4
–OUT – 5
+IN/OUT – 6
–IN/OUT – 7
Data In (A)
Data In (B)
Data Out (A)
Data Out (B)
INS_FDX60_REV–
04/23/10
PAGE 7
INSTALLATION AND OPERATION MANUAL FDX60(M)(S)(-M)
FIGURE 13 – LOOP BACK TEST MODE
1. On one end (Head End), put unit into Loop Back Mode by setting Switch 3 to “OFF.” Switch 1 and 2 can be in any position. Data will not pass during Loop Back Test, LEDs may flash if data is sent during Loop Back Test.
2. If the Far End unit is powered on and the fiber link connections are correct, the Far End unit Loop Back LED will light GREEN.
3. If the Head End unit has Switch 3 in the “ON” position, and if there is a fiber link issue, then the Far End unit Loop Back LED will remain OFF. This is an error condition.
4. If the Far End unit Loop Back LED is GREEN and the fiber link and optical connections back to the Head End unit are correct, then the Head End unit Loop Back LED will light GREEN.
5. If there is a fiber link issue from the Far End back to the Head End, or the Far End unit is not working, the Head End unit Loop Back LED will light RED when the Loop Back switch is set to OFF. This is an error condition.
6. When not in Loop Back Test Mode the Loop Back LED on both ends will be OFF.
TECH SUPPORT: 1.888.678.9427
INS_FDX60_REV–
04/23/10
PAGE 8
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
FIGURE A
Dimensions are for a standard ComNet™ one slot module
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
FIGURE B
Dimensions are for a small size ComNet™ surface mount module
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
© 2010 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Net works, LLC.
INS_FDX60_REV–
04/23/10
PAGE 9
Loading...