Industrial 2-Port Optical Bypass Switch
with 4 × LC Duplex Connectors
CN-OB(M,S)
DIN RAILREDUNDANT
The ComNet CN-OB(M,S) external bypass switches for 100M/1G/10G fiber optic
networks protect the network from failures and ensure network integrity during power
loss. Each of these fiber optical bypass switches includes Network ports and Monitor
ports. The Network ports are used for connection to main-network connections and
provide protection mechanism, and the Monitor ports are used for down-link local
networking device. When the power is on, the operation mode of the Bypass switch is
set to Normal, and the local networking device is connected with main-network. When
power failure occurs, the Bypass switch is swiftly set to bypass mode to isolate the mainnetwork from the local networking device.
-20 TO +70ºC
2 DUPLEX 2 DUPLEX
FEATURES
› Support 100M/1G/10G optical bypass function of 2 port duplex or 4 port simplex
fiber connection
› Different models supported for multi-mode or single-mode optical fiber
› Low insertions loss
› Throughput not affected and no extra delay
› Bypass switching time < 10ms
› Dual wide-range power inputs: 12~48VDC
› Relay output for power failure warning
› Rigid IP-30 housing design
› Surface, Wall or DIN-Rail tmount form factor
› Lifetime Warranty
LIFETIME WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427
CN-OB(M,S)
SPECIFICATIONS
Industrial 2-Port Optical Bypass Switch
with 4 × LC Duplex Connectors
Fiber Optic
Optical Ports 4 Duplex LC connectors
Fiber Single mode 9/125μm 1260 ~ 1570 nm
or Multimode 50/125μm or 62.5/125μm 780 ~
1350 nm (model dependent)
Insert Loss 1.6 dB (Single mode) or <1.0 dB (Multimode)
Switch Time < 10 ms
DIP Switch Settings
DIP Switch 1 Power-1 failure detec tion – relay enable (ON) /
disable (OFF)
DIP Switch 2 Power-2 failure detection – relay enable (ON) /
disable (OFF)
Fault contact
Relay Relay output for power failure warning
Power
Input Power Dual 12~48 VDC power inputs at DC-Jack and
4-pin terminal block
Power Consumption 2.7 W, Typical
Current Protection Overload Current /Reverse Polarity Protected
(Terminal Block Only)
Electrical & Mechanical
Indicating LEDs Power Normal Fault
Enclosure IP-30
Size 1.03 × 3.74 × 5.68 in (2.61 × 9.49 × 14.43 cm)
Shipping Weight 0.89 lb / 405 g
Environmental
MTBF 1,000,000 hours
Operating Temperature -20˚ to +70˚ C
Storage Temperature -40˚ to +85˚ C
Relative Humidity 10% to 90%
Regulatory Approvals
EMI FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-
4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6
(CS), EN61000-4-8, EN61000-4-11
Shock IEC60068-2-27
Free Fall IEC60068-2-32
Vibration IEC60068-2-6
GENCY COMPLIANCE
ORDERING INFORMATION
Part Number Description
CN-OBM Industrial 2-port bypass s witch for fiber optical network with 4 × LC duplex, Multimode, LC connector
CN-OBS Industrial 2-port bypass s witch for fiber optical network with 4 × LC duplex, Single mode, LC connector
Included Accessories Wall-mount Kit
DIN-Rail Kit
Options Power Supply (extra charge, consult fac tory)
NOTE: This product requires a fiber installation with a minimum 30 dB connector return loss. The use of Super Polish Connectors is
recommended. Complies with FDA Performance Standard for Laser Products, Title 21, Code of Federal Regulations, Subchapter J.
In a continuing effort to improve and advance technology, product specifications are subject to change without notice.
TYPICAL APPLICATIONS
Normal Operation Bypass Operation
Power
Supply
CN-OBS
Active
Device
3 CORPORATE DRIVE
© 2016 Communic ation Netwo rks. All Right s Reserv ed. “ComNet ” and the “ComNe t Logo” are regis tered tra demarks of Com munication Net works.
8 TURNBERRY PARK ROAD
|
DANBURY, CONNECTICUT 06810
|
GILDERSOME
|
MORLEY
|
|
USA
T: 203.796.5300
|
LEEDS, UK LS27 7LE
CN-OBS
|
F: 203.796.5303
|
T: +44 (0)113 307 6400
Active
Device
Power
Supply
|
TECH SUPPORT: 1.888.678.9427
|
F: +44 (0)113 253 7462
|
INFO-EUROPE@COMNET.NET
Optical Fiber
|
INFO@COMNET.NET
11 Mar 2016