Comfort Stat CP2020 User Manual

Program Thermostat Owners Manual ModeCP2020
LCD Display:Shows Time,Day,Temperature, Program Number,and other feature information as required.
Temperature Keys: Keys for raising or lowering trmperature setting.
Reviews filter usage in hours and minutes. Also resets filter counter to zero.
L
Battery C ompartment: Front access allows easy insertion of two AA 1.5V batteries.
Front Door: Battery cover Open with one finger from top.
FEATURES
buttons (see below)
Structure of thermostat and explanation for the keypads
Overrides energy­saving program temperatures whi le you are at home for the day.
Measures and displays heating and cooli ng system operating ti me for Today, Yesterday,This Week,Last Week,or Total. By moni toring your energy usage, y ou can program the ther mostat to optimize energy savi ngs.
We are pleased you have selected one of our broad line of wall thermostat. Our products are manufactured to high quality standards and are design for years of service.
Read This Before Installing Thermostat IMPORTANT 1, Read the entire installation section of this Owner’s Manual thoroughly before you
begin to install or operate your Thermostat. REMOVE THE MYLAR LABEL FORM THE LCD DISPLAY WINDOW.
INSTALLATION 2, All installation is normally performed at your thermostat. ARMCHAIR PROGRAMMING 3,You can program your thermostat before installation by inserting the batteries and
following the instructions starting Feature selector switches .This can be done while
Automaticall y programs the thermostat to i ts built-in ENERGY STAR compliant program setti ng.
For entering hour of day.
HOME
TODAY
ENER
R
system
cool
heat
off
auto
Front Door:Covers keys Open with one finger from left or right.Soft touch programming
For entering minute of day.
PROG
DAY
HOLD
CLEAR
DAY
HOUR MIN
AUTO PROG
Selects the day or days to review or change i n Program Mode.
Fan Switch: Fan
fan
switch fo r Automatic or Continuous fan
auto
on
operation.
System Switch: Selecto r switch for Cool,O ff,Heat or auto.
For entering day of week.
Enters Program Mode for reviewin g and changing weekday, weekend,or daily
PROG
programs.
RUN
Returns displa y to current
time and temperatur e. Provides permanent temperature sett ing by overriding st ored programs. It also returns the ther mostat to current program control from man ual override or Home Today mode.
you relax in your favorite chair and is a very good way to familiarize yourself with all the functions of your thermostat.
The following time and temperature settings are pre-programmed into the thermostat:
Temperature in F˚ (C˚) Program Number Time Heat Cool
1 6:00 am 68˚F(20˚C) 78˚F(26˚C) 2 8:00 am 60˚F(16˚C) 85˚F(29˚C) 3 4:00 pm 68˚F(20˚C) 78˚F(26˚C) 4 10:00 pm 60˚F(16˚C) 82˚F(28˚C)
OPERATION
4Your Thermostat is designed to operate with most gas, oil, electric or 2-wire hot water heating and air conditioning systems. It will also operate single-stage heat pumps that do not have auxiliary or emergency heat. These have 24-volt or millivolt control systems and represent most central heating, air conditioning, or space heating units in use in the United States. This Thermostat will NOT control multi-stage heat pumps or 110/220Volt systems. COMPRESSOR PROTECTION 5, The thermostat provides a 4 minutes delay after shutting of the heating or cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. Note that this delay also applies to the heating system control. It does not provide a delay when there are power outages.
Temperature Range
This thermostat can be programmed between 45˚F and 95˚F (7˚C and 35˚C). However, it will display room temperatures from 30˚F to 99˚F (0˚C and 37˚C). “HI” will be displayed if the temperature is higher than 99˚F (37˚C), and “LO” will be displayed if the temperature is lower than 30˚F (0˚C). This thermostat will automatically cutoff in Heat mode if the temperature rises above 95˚F (35˚C), and automatically cutoff in Cool mode if the temperature drops below 45˚F (7˚C). NOTE: The thermostat will automatically change to the Cool mode if the thermostat measure a temperature over 99˚F(37), ”HI” will be displayed on the LCD, and the Cooling system will turn On. Similarly, the thermostat will automatically change to the Heat mode if the temperature is below 32˚F(0). and ”LO” will be displayed on the LCD, and the Heating system will turn On. POWER FAILURE 7, Whenever the main power is interrupted or fails, the battery power retains and current time. AUTO RECOVERY 8, Your thermostat is set from the factory to gradually recover the room temperature from an energy saving program to your comfort program. Therefore, the thermostat may turn your system on several minutes prior to your programmed the Selector Switches information on Selector switches BATTERY WARNING 9,Fresh alkaline batteries should provide over one year of service. However, when the batteries become drained, “BATT” will alternate on the display with the current time. When this message occurs, install 2 new AA batteries, You have approximately 1 minute to change the batteries and keep thermostat’s clock and program settings. Once the batteries have become too low to ensure proper operation, your system will be turned Off, and the display will be cleared except for “BATT” flashing on the LCD display.
CAUTION: Once only the “BATT” only display occurs, the thermostat is shut down, and
your system will no longer operate. In this condition, there is no temperature control of your dwelling. NOTE: The backlight will not function when the
thermostat is in low battery condition.
NOTE: If you plan to be away from the premises over 30 days, we recommend that you replace the old batteries with new alkaline batteries prior to leaving.
INSTALLATION
What You Need This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your thermostat, you should have the following tools and materials.
y Slotted Screwdriver(s) y Small Philips screwdriver y Hammer y Electric drill and 3/16” bit y Two1.5V (AA) size alkaline batteries (included)
Remove Old Thermostat
CAUTION: Do not remove any wiring from existing thermostat before r eading the instructions carefully. Wires must be labeled prior to removal. INPORTANT! Turn off the power to the furnace at the main power panel or at the furnace.
Remove existing thermostat cover and thermostat. See Figure 1. Some thermostats will have screws or other locking devices that must first be removed. Once the wall mounting plate is exposed, look for wires. If wires are not visible, they may be connected to the back of the wallplate. Again, look for screws, tabs, etc. Some models have doors that open to expose wires and mounting screws. See Figure 1.
Typical Home Thermostats
Wall mounting Plate Thermostat Cover
Figure
1
Wiring Labeling
y Each wire coming from the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a code latter as shown in Table A below. y Note that this thermostat has multiple function terminals that allow Single-Stage Heat Pump capability. Standard systems use: Rh, Rc, G, Y, W. [Single-Stage Heat Pumps use: R, Y, G, and O or B.] Table A below shows the multiple functions of the terminals. Use the terminals that match your system. y The number of wires in your system can be as few as two (for heat only systems), as many as eight, or any number in between. If you follow the labeling procedures correctly, you do not have to be concerned about how many wires there are. y There is often no terminal marking on the existing thermostat of two wire, heat only systems. Just connect either of the wires to the RH terminal, then connect the other wire to the W terminal to complete the circuit.
y IMPORTANT! BEFORE DISCONNECTING ANY WIRES, APPLY THE SELFADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN TABLE A BELOW. (For example, attach the label marked W to the wire that toes to the W or H
terminal on your existing thermostat.) IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard. y After labeling wires, disconnect them from the existing thermostat.
Y
RH
G
W
RC
y Remove existing wallplate. To make sure wires do not fall back into wall opening, you may want to tape them to the wall. y If hole in wall is larger than necessary for wires, seal this hole with insulating material so that no hot or cold air can enter the back of the thermostat from the wall. This air could cause a false thermostat reading.
If the code letter on
your existing
Thermostat is
RH,R, VR or 4 24 Volt
RC,VC, 24 Volt C ool
G or F Fan
Y,Y1 C or M (S ee N ote ) Air Conditioning C om pressor
W or H Heating Not for heat pum ps
O , B , o r R Reversing V alve (S ingle-stage Heat Pum ps only)
Tab l e A
then mark the wire with
label shown
and connect to
thermostat terminal
shown
RH
RC
G
Y/Y1
W
O/B
NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to non-battery powered thermostats.
Mount Wallplate and Thermostat
Figure 2
y Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2.
y Position wallplate on wall and pull existing wires through large opening. Then level for appearance. Mark holes for plastic anchors provided, if your existing holes do not line up with those on the wallplate. y Drill holes with 3/16” bit and gently tap anchors into the boles until flush with wall. y Reposition wallplate to wall, pulling wires through large opening. Insert mounting. Figure3
R
C
Y
/Y
1
R
W
H
OB
G
screws provided into wall anchor and tighten. See Figure 3.
NOTE: 5- Wire Systems
If your thermostat has one wire marked R or Rh (2, 3, or 4-wire system), then leave the jumper wire between the Rh and Rc terminals on the wallplate. Otherwise, if you have separate Rh and Rc wires (5-wire system), then remove the jumper wire between the Rh and Rc terminals.
Connect Wires and Mount Thermostat to Wallplate Figure 5 y Match and connect the labeled wires to
the appropriate coded terminal screws on the wallplate. (See Figure 4, 5) Ignore any wires which may be present, but which were note connected to the old thermostat.
Figure4
RH
y Refer to the Wiring Diagrams below to be sure your system is wired correctly. y Be sure to tighten the terminal screws securely, otherwise a loose wire could cause
operational problems with your system or thermostat.
y Push excess wire back into the hole to prevent interference when installing the
thermostat to the wallplate.
y Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO. y If your system is a single stage heat pump and uses an O or B wire, you must move the
System Selector switch inside the thermostat to the Heat Pump position. If you have a normal furnace or electric system, leave the switch in the Standard position. Refer to the System Selector section on the back for more information on this switch. yInsert the tabs on top of the thermostat body into the slots at the top of the wallplate. Press the bottom of the thermostat body into the snap on the bottom of the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not work.) y Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment. y Switch on the main power at the panel or furnace.
Selector Switches
In order for this thermostat to control your system, the system type must be specified by the selector switches on the printed circuit board inside the thermostat. There is also a selector switch for your choice of Fahrenheit or Celsius temperature display. y Heating System Selector (HG – HE switch) The factory position for this switch is in the “HG” position. Leave in this position if you have a gas furnace or an oil burner. If you have an electric furnace, test to see whether the Heat and Fan come on as expected after installation. If the Fan operation is normal, leave it in the “HG” position. If the Fan does not come on within minute of the thermostat calling for heating, change the switch position to “HE”. The system selector has no effect in the cooling mode. NOTE: “HG” position is for gas and most other systems. “HE” position is for certain electric systems having a fan relay.
y Furnace or Heat Pump selector (NORMAL-O-B switch) The factory position for this switch is in the
NORMAL position. Leave it in this position if you have ANY system that uses gas, oil, electric, or hot water heating. If you have a single-stage Heat Pump (no auxiliary or emergency heat source), then slide the switch to the position that
O
K3
(NORMAL-O-B SWITCH)
B
NORMAL
SYSTEM SETTING
NAME
ALTERNATE
* STANDAND
F/C
CELSIUS
FAHRENHEIT
12/24
24 HOURS
12 HOURS
SPAN
+2F/-1F
+1F/-1F
RECOVERY
DISABLE
ENABLE
* DEFAULT SETTING
HG HE
(HG-HE SWITCH)
CELSIUS
(+2F/-1F)
24 HOURS
DISABLE
K2
JP1
1234
12 HOURS
FAHRENHEIT
SPAN (+1F/-1F)
RECOVERY ENABLE
matches your Reversing Valve type. If your heat pump system has a “B” wire, slide the switch to ”B” for your reversing valve that activates in HEAT mode. If your heat pump system has an “O” wire, slide the switch to “O” for your reversing valve that activates in COOL mode.
Feature Selector Switches:
y F˚ / C˚ selector (Fahrenheit / Celsius)
Your thermostat is set for F˚ mode from the factory. In order to change to C˚ mode, slide the switch to C˚ and Move the battery out and wait for about 1 minute then place the batteries .
NOTE: Unless press any key about 2 seconds without the battery, then place the battery again. the thermostat will not change temperature mode. All progra ms and settings will be lost..
I 12Hr. / 24 Hr. selector Your thermostat is set from the factory in normal 12 (AM/PM) time format. To change to 24 hour (military) time, slide the Switch to the 24 position. This change may be made without resetting the thermostat, and will automatically change the current time display and all program times in memory. Span selector –Switch 7 Your thermostat is set temperature. If you require slower temperature cycles in Heat mode, you can select +2˚F/-1˚F by sliding the switch to the ALT position. This may be necessary if your heating system cycles too rapidly.
Auto Recovery select
Your thermostat is set from the factory with the Auto Recovery Feature enabled , If you prefer to use normal recovery, slide the switch to the ALT position. Table B below summarizes the Feature Switches discussed above. A similar table is printed directly on the circuit board for your quick reference.
Switch Setting
Function Alternate Standard
˚F/ Celsius Fahrenheit
12Hr. / 24 Hr. 24 Hour 12 Hour
Span +2˚F/-1˚F +2˚F/-1˚F
Auto Recovery Disable Disable
Setting Time And Day
Tab l e B
Remove the mylar lable covering the LCD display window before operating thermostat.
Initial display after power-up. The temperature will
update after a few seconds. EXAMPLE: Set the Thermostat to the current to the current time of 9:43 a.m. on Saturday Refer to Figure at right
During time and day setting mode , the temperature
HOUR
and program display will go blank.
Press and hold to rapid advance to the current hour. Tap to advance one hour at a time. Note the AM /PM
MIN
indicator, as the display will cycle through 24 hours.
Press and hold to rapid advance to the current hour. Tap to current minute. Tap to advance one minute at
DAY
a time.
Tap to advance one day at a time.
When finished, press to RUN to the Normal time and
RUN
temperature display or wait 15 seconds for it to return to Normal mode automatically.
Auto Programming
Studies conducted by the Department of Energy estimate that setting your thermostat back 10˚F (6) for two 8-hour periods during winter can reduce your fuel bill by as much as much as 33%. By setting your thermostat up 5˚F (3) for tow 8 hour perids during summer you can reduce your fuel bill up to 25%. Your thermostat is capable of holding up to 4 separate programs for each day of the week. You can program all weekdays, Monday to Friday, to the same 4 programs as show in the table, or each weekday can have a different set of 4 programs. Simillarly weekend programs, Saturday and Sunday, can be the same 4 programs or each weekend day can have a different set of 4 programs. Your thermostat is pre-programmed to meet the ENERGY STAR guidelines for energy efficiency. Note that it is easier to modify these programs than to programs than to
program the thermostat manually.
Press once. During Auto Programming, the
AUTO
display will change as shown.
PROG
The thermostat will be programmed for all 7 days of the week as shown .below.
Temperature in ˚F/
Program Number Time Heat Standard
1 6:00am 68 ˚F (20℃) 78 ˚F (26℃)
2 8:00am 60 ˚F (16℃) 85 ˚F (29℃)
3 4:00am 68 ˚F (20℃) 78 ˚F (26℃)
4 10:00am 60 ˚F (16℃) 85 ˚F (29℃)
Refer to Manual Programming entering or changing the programs.
PROGRAMMING
Before programming or changing programs, use this Personal Program Schedule to determine which times and temperature Settings will best satisfy both your comfort and energy saving requirements. Use a pencil so you can revise yours records each time you change your temperature settings.
Heating
DAY Program1 Program2 Program3 Program4
Mon. Time
Tem p
Tues. Time
Tem p
Wed. Time
Tem p
Thurs. Time
Tem p
Fri. Time
Tem p
Sat. Time
Tem p
Sun. Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Cooling
DAY Program1 Program2 Program3 Program4
Mon. Time
Tem p
Tuse. Time
Tem p
Wed. Time
Tem p
Thurs. Time
Tem p
Fri. Time
Tem p
Sat. Time
Tem p
Sun. Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Time
Tem p
Manual Programming
Your thermostat can be programmed for weekdays and weekends , or have unique programs for all 7 days .Use Weekday /Weekend Programs below or 7-day .programming to enter or revise programs to match your Personal Program Schedule. The same steps are used when entering programs for the first time, or revising programs entered during Auto Programming.
Familiarize yourself with Manual Programming, so that you can easily modify your programs as your comfort needs change. The example below demonstrates the Manual Programming method. NOTE: The program time can be set in 10 minute increments, and remains the same for
both Heat and Cool programs. The program temperature can be set in increments of 1˚F (1˚C).
3,The Heat setpoint can not be set higher than the Cool set point, and the Cool set point can not be set lower than the Heat set point. 4, If the system selector is in AUTO mode, the current operating mode will be used for programming. 5, After 15 seconds without a key press, the thermostat will return to normal display mode.
6, When setting the program time, note the AM/PM indicator.
y
7, With the Auto Recovery feature enabled, you do not need to set your comfort program times early. Auto Recovery will determine how early Recovery will determine how early to turn your system on, so that the room is comfortable at the program time.
Weekday/Weekend Programming Step1
Slide System Selector Switch to HEAT or COOL to program the corresponding system. NOTE: If the system selector is in the OFF position, no
system
cool
heat
auto
off
Programming Your Thermostat (Continued)
Permanent Override or a Designated Day Override
To hold your Manual Override for vacation or Until a Designated Day
programming is permitted. The LCD display will show only dashes when the program key is pressed. Weekday/ Weekend Programming (cont.)
Press PROG key to enter program mode,
Step2
PROG
display shows weekday programs.
Display for HEAT mode shown.
Step3 Use and to change the set point time.
HOUR
MIN
Use and to change the set point temperature.
y You can confirm the held set temperature by pressing for less than 1 second.
y Press again. Hold day will be displayed on the lcd and the clock
will disappear
yPress Day key to add override days. Press Program key to
Step4 Press to move to programs 2,3 and 4.
Repeat Step3 to complete the weekday
programs.
PROG
Step5 Press to change to the next day’s programs.
DAY
Repeat Step 3 and 4 to complete the weekend programs
.
RUN
Step6 If you desire only weekend and weekday programs, press to RUN to
normal mode.
After 15 seconds, the thermostat will return to normal
mode automatically.
system
Step7 ■ Change the System Selector Switch to the other system. And
cool
heat
off
repeat Step2 through 6 above.
auto
7-DAY Programming
system
Step1 Slide System Selector Switch to HEAT or
COOL to program the corresponding system.
cool
heat off
Step2 Press to enter program mode, display shows
auto
weekday programs.
PROG
Step3 Use and to change the setpoint time.
DAY
HOUR
MIN
Use and to change the setpoint temperature.
Step4 Press to move to programs 2, 3 and 4.
PROG
Repeat Step 3 to complete the programs for Monday.
Step5 Press to change the next day’s programs.
Step6 When finished press to return to normal mode.
PROG
DAY
RUN
Continue repeating Step3,4 and 5 to
program all 7 days of the week.
To end Override:
yUnder Permanent Override Press hold/return key twice. Under a Designated Day
Override press the hold once. The thermostat will return to the current program, and the
HOLD display will be canceled. NOTE: The Auto Season Changeover feature will not operate while the thermostat is in permanent Manual Override .Refer to the Auto Season Changeover feature for more information.
Auto Season Changeover
When the System Selector is in AUTO position , the thermostat will automatically change between Heating and Cooling systems, depending on your program .We recommend keeping your programmed heating and cooling temperature at least 4˚F (2˚C) apart to allow the Auto Season Changeover to occur when the appropriate temperature span has been reached. However, if your heating and cooling programs set temperatures are close, there is a built-in program to prevent the thermostat is in Temporary, a Designated Day Override or Permanent Override , as these overrides are energy saving settings. Auto Season Changeover will still function in Home Today mode, as this is a comfort setting. For example, you may have the following temperatures programmed at a given time: Heat Set Temp=68˚F Cool Set Temp=78˚F If the room temperature rises above 78˚F, then the thermostat will automatically change to cool mode and turn on the air conditioner. Likewise, the thermostat will automatically change to heart mode and turn On heat when the room temperature falls below 68˚F.
HOME TODAY
This patent pending feature allows you to quickly and temporarily override your energy saving program setting on days when you are normally away from home with one key press.
PROG
After 15 seconds, the thermostat will return to
normal automatically.
7-Day Programming (continue)
s
stem
Step 7 Change the System Selector
cool
heat
auto
off
Reviewing Programs
You may want to review the programs to confirm that the settings are compatible with your lifestyle. Weekday Programs Press to display M-F programs.
PROG
Switch to The other system, and repeat 2 through 6 above.
Auto Season Changeover) during the “Home Today” override period, the setpoint temperature will be automatically update.It will automatically change from the highest heat program setpoint to the highest heat program setpoint .
Press repeatedly to cycle through the 4 programs.
Weekend Programs Press to display the Sa-Su programs.
Press repeatedly to cycle through the 4
PROG
DAY
PROG
Daily Programs Press to display M-F programs. NOTE: Time and Temperature display will be blank when at least one weekday program is different.
Press to change to Sa-Su. Again, if the display is blank , one
PROG
DAY
of the weekend programs is different.
Press again to change to Monday’s program.
PROG
Continue pressing to cycle through each day.
Energy Monitor
Press repeatedly to cycle through the 4 programs.
Press to return to normal mode.
RUN
After 15 seconds, the thermostat will return to normal mode. automatically . NOTE: Programs take affect as soon as the thermostat returns to normal mode. If you are armchair programming the thermostat, slide the system selector to the OFF
position before mounting the thermostat to the wall plate.
Reviewing the Current Temperature Setting
Current time and temperature.
Thermostat is set to AUTO , and the heating system is
on.
Press for 1 second or less.
Set Temperature is shown above current room
temperature.
OPERATION
System Selector Switch
The System Selector Switch on the front of the thermostat determines the Operating mode of the thermostat. You may select COOL ,OFF ,
system
HEAT,AUTO. In order to take full advantage of this thermostat’s feature, we recommend using the AUTO mode. Refer to the Auto Season Changeover information on Auto Season Changeover..
cool
heat
auto
off
NOTE: Anytime you install or remove the thermostat form the wallplate, slide the System Selector to the OFF position to prevent the possibility of a rapid system On-Off.
Fan Switch
fan
The Fan switch should normally be located in the AUTO position. The Fan will be turned on along with normal operation of your system. In a normal gas or oil furnace, the Fan will be turned on by
auto
on
your furnace after its warm-up delay. For electric heat, air conditioning, and heat pump operation, the Fan will turn on with the system. To run the Fan on continuously, slide the Fan switch to the ON position.
Temporary Manual Override
To temporarily change the current set temperature without affecting your program:
Press and hold or for less than 1 second to enter Manual Override mode..
Press and to change to your desired new temperature.
Press to RUN to normal mode, or wait 15 seconds for it to return
RUN
automatically.
The current program number will flash to signify the Temporary Override. At the next program change, the Temporary Override, and the next program temperature becomes the set point temperature. To end the Temporary Manual Override:
HOLD
CLEAR
Press and wait for HOLD to display on the LCD.
Press hold key. This will return the set temperature to the current program
set temperature.
NOTE: The Auto Season Changeover feature will not operate while the thermostats is
NOTE: Clearing the Energy Monitor counter will also clear the Filter Monitor
counter , as Filter usage and Total Energy usage are the same. Also, clearing the filter Monitor counter will clear ALL Energy Monitor counters as well. Filter Monitor
Your thermostat also keeps a record of the number of hours your filter has been in use. To maximize your system’s performance and energy efficiency, change or clear your filter regularly.
When the total system run time for heat and cool reaches 500 hours, you to clean or change your system’s filter, “FILT” will contunre to flash until the counter is set back to zero.
Press to review total filter usage. The display will blink “FILT” Then show the filter Monitor counter. After 15seconds, the display will return to normal mode, or you can hit RETURN to exit immediately. The Filter Monitor will display up to 999 hours and 59 minutes of usage. In this example, the counter is at 410 Hours, 26 minutes.
To reset the Filter Monitor counter, depress FILTER for 3 seconds. The display will blink, and The counter will be reset to zero.
NOTE: Clearing the Filter Monitor counter will also clear ALL Energy Monitor counters, as Filter usage and Total Energy usage are the same. Also, clearing the Energy Monitor counters will clear the Filter Monitor counter as well. Auto Recover y
Auto Recovery calculates how early to turn you system back on, so that the room temperature is already comfortable by the start of the comfort temperature program period. Auto Recovery work’s in both Heat and Cool modes. yWhen the thermostat is in Auto Recovery mode, the display will alternate “RECO” with time, and the program indicator will flash. yAuto Recovery can be disabled by sliding the Recovery switch on the circuit board to disable.
yAuto Recovery will not operate if Permanent hold or Temporary hold is in operation. yAuto Recovery can be canceled manually if Hold/RETURN is pressed during the
recovery process. yAuto Recovery will be canceled and change to next period.
Details of Auto Recovery Operation:
in Temporary Manual Override .Refer to the Auto Season Changeover feature for more information. NOTE; If the thermostat has not been programmed, then a Temporany Override becomes a Permanent Override. See the next section for more information.
HOLD
y Press to make the current program temperature the
CLEAR
HOLD temperature. HOLD will be displayed on the LCD,
and the Program number will disappear.
y Follow the Temporary Manual Override instructions
above to change the
Permanent Manual Override temperature.
reduce override days
HOLD
CLEAR
y Follow the Temporary a Designated Day Override instructions above to
change the Permanent Manual Override temperature.
DAY
HOUR
Press to enter the Home Today override .The highest program temperature for today will be selected from your programs in Heat mode
HOLD
and become the set temperature.(In Cool mode ,Home
CLEAR
Today will select the lowest program temperature for today to be the set temperature.)
The display will alternate between “HOME” and the current time.
When pressed during the day, the thermostat will remain in Home Today mode
HOME TODAY
until the first program of the next day.
If the system is changed between Heat and Cool modes (either manually or by
Press to exit Home Today mode before the schedule ending time. “Home
Today” override period, the setpoint temperature will be automatically updated. It will automatically change from the lowest cool program setpoint to the highest heat program setpoint.
Press to exit Home Today mode before the schedule ending time.”HOME” is no longer displayed on the LCD screen, and the thermostat returns to the current program.
You can manually change the setpoint temperature while in Home Today mode. Refer to the Temporary Manual Override instructions .Manually changing the set temperature while in Home Today mode will not affect the Home Today ending time, However, the set temperature will not change automatically with a manual or Automatic change between heating and cooling.
The Energy monitor feature measures and stores the amount of time the heating and air conditioning system operates. Usage can be display for Today (since 12 am), Yesterday, This Week (since Monday), Last Week (last Monday through Sunday), and Total (up to 999 Hrs).By monitoring your energy usage, you see how much the set-back periods are saving , and you can test
ENER
program adjustment to save even more. To review energy usage, press to cycle through Today, Yesterday, this Week, Last Week, and Total. Press again to return to normal mode, or wait 15 seconds for the display to return to normal mode .You can also return to normal mode at any time by pressing RERURN.
For example: This LCD display shows Today’s usage to be 10 Hours, 26 minutes.
ENER
Press and hold for 3 seconds to reset the Energy Monitor ’s counters. The display will blink, and counters will be cleared to zero.
Auto Recovery can be disabled by sliding the Recovery switch on the circuit board
to the ALT position.
Today is in operation.
Auto Recovery can be canceled manually if HOLE/CLEAR is pressed during the
recovery process. If a recovery process is canceled manually then the recovery process will not start again until the next program period starts (an exception is that if time or program is changed then the thermostat will check Auto Recovery conditions immediately).
Auto Recovery will be canceled and change to Home Today mode if HOME TODAY is pressed during the recovery process.
Keyboard lock
The keyboard can be locked to prevent unauthorized changes to the thermostat.
To lock or unlock the keyboard, press and hold BOTH the Keys for 3 seconds. The keyboard is locked when LOCK appears on the display.
All keys are locked, Any time a key is pressed, LOCK will appear on the display for 1 second.
Backlighting
Your thermostat has an electroluminescent lamp that backlights the display for easy viewing in the dark. When any key is pressed the display is illuminated. The display will remain illuminated for 8 seconds after the last key is pressed. This allows the light to stay on if you need to operate several keys. Note: If the thermostat is in Low Battery warning condition, the backlight will not operate. Replace with 2 new AA alkaline batteries to restore the Backlight function.
Low Battery Warning
Your thermostat has a two-stage lower battery warning system. When the batteries are first detected to be weak, the first stage low battery warning is indicated by battery symbol flashing on the LCD display. At your earliest convenience, you need to replace the batteries with 2 new AA alkaline batteries. When the batteries become too week for normal operation, the thermostat enters the second stage low battery warning which shuts down the thermostat. In this condition, “BATT” flashes alone on the display, and the thermostat will turn your system Off. Your system will remain shut-off until the batteries are replaced. Note: The thermostat will still keep the current Set Temperature and Filter run time in memory until new batteries are installed. After confirming that new batteries have been inserted, the thermostat will return to normal operation.
Error Mode
If the thermostat is unable to control your system due to an unexpected battery problem, the thermostat will enter Error Mode. In this condition, the thermostat flashes “E1”or “E2”on the LCD display, and shuts off your system. To correct this problem, replace the batteries with 2 new AA alkaline batteries, even if you have recently replaced them. Move the battery out hold any key then place the battery again. You will need to reprogram your thermostat and confirm normal operation.
If Error Mode returns, please call us for further information.
Auto Cut Off
Your thermostat will automatically cutoff in Heat mode if the room temperature rises above 95˚F (35˚C). It will cutoff in Cool mode if the room temperature drops below 40˚F (4˚C). Note that if your system has malfunctioned and no longer responds to thermostat controls, the Auto Cut-Off will have no effect.
THERMOSTAT
RH
THERMOSTAT
G
O/B
Y
RC RH
G
O/B
Y
Wiring Diagrams
RC
THERMOSTAT
RC
RH
G
O/B
Y
THERMOSTAT
RC
RH
G
O/B
Y
THERMOSTAT
RC
RH
G
O/B
Y
THERMOSTAT
RC
RH
G
O/B
Y
TROUBLESHOOTING
Solution
Problem
SCRAMBLED OR
1. Remove clear mylar sticker. DOUBLE DISPLAY (numbers over numbers)
NO DISPLAY 1. Check battery connections and batteries
2. Move the battery out hold any key then place. The
battery again.
ENTIRE DISPLAY DIMS
PROGRAM DOES NOT CHANGE AT YOUR DESIRE SETTING
1. Replace Batteries
1. Check that the time is set properly to “A M” or “P M”
2. Check that the thermostat is not in “HOLD” o r“ Home
Today” mode.
3. Check for the correct day settings.
AUTO/FAN DOES NOT TURN ON
GO
ON OR OFF
1,Move HG/HE selector to opposite position (“HEAT,”COOL” or “AUTO”) 2,The thermostat may be in the AUTO Mode. Look for ”AUTO” on the LCD display. If the Heat and Cool program temperature are close, then the thermostat requires a larger room temperature change before changing from Heat or Cool. 3,There may be as much as 4 minute delay before the Heat or Cool system turns On-wait and check. (Compressor protection delay). 4,Check your circuit breaks and switches to ensure there is power to the system.
5. Replace batteries.
6. Make sure your furnace blower door is closed properly.
7. If your system only uses 4-wires, be sure the jumper wire is
installed between the RC and RH terminals.
8. Check the position of the Furnace or Heat Pump selector
switches: Normal/O/B.
is in the correct position
Problem (cont.) Solution (cont.)
ERRATIC DISPLAY 1. Move the battery out hold any key then place the battery
again.
IF UNIT CONTINUES TO OPERATE IN
1. Replace unit
THE OFF POSITI ON
THERMOSTAT PERMANENTLY
1. Replace unit.
READS“HI”, “LO,” OR “ERR-” AFTER PRESSING TER PRESSING
If you experience any other problems, call us for technical assistance.
The service number is 1-866-591-9898
Loading...