2
GENERAL INFORMATION
TRANSDUCERS SHOULD NOT BE DISCONNECTED FROM THE
WARNING
PRESSURE SOURCE WHILST CONTAINING GASES WHICH ARE
DANGEROUS AND/OR UNDER PRESSURE.
DO NOT APPLY PRESSURES BEYOND THE OVER RANGE MAXIMUM FOR THE TRANSDUCER OR DAMAGE WILL OCCUR.
REFER TO SECTION 3 - CONNECTION TO PRESSURE SOURCES
BEFORE OPERATING THE INSTRUMENT.
TO AVOID ELECTRIC SHOCK DO NOT ALLOW ANY TRANSDUCER
OR CABLE TO COME INTO CONTACT WITH LIVE ELECTRICAL
POWER CONDUCTORS WITH VOLTAGES IN EXCESS OF 30V AC
RMS OR 60V DC.
CAUTION
Pressure Transducers
This precision instrument has been designed for use with the
extensive range of Comark pressure transducers. The use of
other transducers may impair the performance and accuracy of the
instrument. Full details of Comark transducers may be obtained
from Comark Customer Support department or your local distributor.
Repeated sharp exing can break transducer connection cables.
To prolong lead life, avoid sharp bends or kinks in the leads, especially near the connectors.
This instrument is manufactured in accordance with the company’s ISO 9001 Quality Approved System.
CERTIFICATE No. FM29700
This instrument complies with the Electromagnetic Compatibility Directive EN61326-1:2006.
Declarations of Conformity available. Contact Comark Customer Support or your local Distributor.
In line with its policy of continuous development, Comark Limited reserves the
right to alter the instrument specication without prior notice. Further information
is available from Comark Limited or your distributor.
3
CALIBRATION, CERTIFICATION AND SERVICE
Certication
Comark can provide certicates of calibration for its whole product
range, to suit ISO 9000 and other quality assurance procedures, food
hygiene regulations, HACCPs and environmental regulations. Comark
certicates are produced by independent quality controlled processes
which compare product performance against agreed National Standards. For peace of mind and best practice Comark recommend annual
certication/recalibration.
Two levels of certication are available for infra-red temperature and
non temperature instruments, excluding humidity:- UKAS certicates via
an external accredited laboratory and NPL traceable certicates from
the Comark calibration laboratory.
Three levels of certication are available for contact temperature and
humidity products and these are detailed here:
a) UKAS Temperature Certication
The Comark UKAS (United Kingdom Accreditation Service)
accredited temperature calibration laboratory is one of the nest in the UK. Comark UKAS certicates can offer the lowest
uncertainty of 0.01°C and provide independent proof of correct
calibration using equipment and procedures audited by UKAS
inspectors. The equipment used is fully traceable to the National Physical Laboratory.
b) UKAS Humidity Certication
In addition to the Comark temperature laboratory, the humidity
laboratory continues the tradition of high accuracy certication
and a wide range (25% to 90%RH) with uncertainties of 2.8% of
reading. This range also includes Dew point measurements.
c) NPL Traceable Certication
Comark NPL certicates are traceable to the National Physical
Laboratory and can offer uncertainty as low as 0.3°C.
4
Conformance
Certicates of conformance can be supplied for new, serviced and
recalibrated instruments. These conrm that instruments are within their
original manufactured specication.
Service/Repairs
Regular servicing and any required repairs, under warranty or after, are
available from the Comark Service Department.
For more information on all Comark certication, calibration and service
facilities please call Comark Customer Support or contact your local
distributor.
5
1 INTRODUCTION
1.1 Transducer Input
The C9550 external pressure meter accepts all Comark
pressure transducers model 3392, 3393, 3397 or 3398.
Connection is made by means of the 8-pin socket and
the 1.5 metre interface cable. An inbuilt serial interface
allows the C9550 to communicate with the transducer
and provide correct display of the pressure value in any
one of the pressure units selected. Suitable pressure
transducers are:
Model Pressure range, bar Diaphragm Type
3392/PG Series 0.1 to 4000 Internal Gauge
3393/PA Series 0.25 to 16 Internal Absolute
3397/PGF Series 0.1 to 600 Front Flush Gauge
3398/PAF Series 0.25 to 16 Front FlushAbsolute
Table 1. Transducer Model References
1.2 Transducer Operator Manual
The separate Transducer Operator Manual provides
details of the installation, troubleshooting and calibration of transducers.
1.3 Transducer Range Data Sheet
Pressure ranges extend from 0.1 to 4000 bar. The
separate Transducer Range Data sheet, Ref: C089,
lists all pressure ranges available in each of Gauge /
Absolute, Internal Diaphragm / Front Flush Diaphragm,
0.5% / 0.25% accuracy types.
1.4 Ranges, scales and resolutions
A tabular listing of the scales and resolutions of Comark
stocked ranges is provided in section 5.3. The complete listing for all 24 ranges is available separately as
Engineering Note 18, and is available from the Customer Service Department.