Comark 3392-PG Installation Manual

C9550 EXTERNAL
PRESSURE METER
OPERATING MANUAL
1
CONTENTS
CALIBRATION, CERTIFICATION
1.1 Transducer Input . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.2 Transducer Operator Manual .................6
1.3 Transducer Range Data Sheet ...............6
1.4 Ranges, scales and resolutions ...............6
2.1 ON/OFF Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 ZERO Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3 SCALE Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.4 HOLD Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5 FILTER Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.6 RECORD Key . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.7 AUTO Switch Off . . . . . . . . . . . . . . . . . . . . . . . . . 8
4 OTHER FUNCTIONS .................... 10
4.1 Battery Low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2 Over 9999 Reading Indication ...............10
4.3 Absolute or Gauge Measurement . . . . . . . . . . . . 10
4.4 Error Messages ..........................10
4.5 Battery Replacement ......................11
5 UNITS OF MEASUREMENT .............. 12
5.1 The C9550 Pressure Scaling System . . . . . . . . . 12
5.2 Calibration Scale . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 3. Scale Conversion Factors ...............13
5.3 Table of Full Scale Pressures
and Resolutions . . . . . . . . . . . . . . . . . . . . . . . . . 14
1
6 OPTIONAL EQUIPMENT . . . . . . . . . . . . . . . . 15
7. WIRING OF INTERFACE CABLE .......... 16
8. INSTRUMENT SPECIFICATION ........... 17
Declaration of Conformity . . . . . . . . . . . . . . . . . . 18
FIGURE 1 View of the measurement system . . . . . . . . 19
2
GENERAL INFORMATION
TRANSDUCERS SHOULD NOT BE DISCONNECTED FROM THE
WARNING
PRESSURE SOURCE WHILST CONTAINING GASES WHICH ARE DANGEROUS AND/OR UNDER PRESSURE.
DO NOT APPLY PRESSURES BEYOND THE OVER RANGE MAXI­MUM FOR THE TRANSDUCER OR DAMAGE WILL OCCUR.
REFER TO SECTION 3 - CONNECTION TO PRESSURE SOURCES BEFORE OPERATING THE INSTRUMENT.
TO AVOID ELECTRIC SHOCK DO NOT ALLOW ANY TRANSDUCER OR CABLE TO COME INTO CONTACT WITH LIVE ELECTRICAL POWER CONDUCTORS WITH VOLTAGES IN EXCESS OF 30V AC RMS OR 60V DC.
CAUTION Pressure Transducers This precision instrument has been designed for use with the extensive range of Comark pressure transducers. The use of other transducers may impair the performance and accuracy of the instrument. Full details of Comark transducers may be obtained from Comark Customer Support department or your local distribu­tor.
Repeated sharp exing can break transducer connection cables.
To prolong lead life, avoid sharp bends or kinks in the leads, espe­cially near the connectors.
This instrument is manufactured in accordance with the company’s ISO 9001 Quality Approved System.
CERTIFICATE No. FM29700
This instrument complies with the Electromagnetic Compatibility Directive EN61326-1:2006.
Declarations of Conformity available. Contact Comark Customer Support or your local Distributor.
In line with its policy of continuous development, Comark Limited reserves the
right to alter the instrument specication without prior notice. Further information
is available from Comark Limited or your distributor.
3
CALIBRATION, CERTIFICATION AND SERVICE
Certication
Comark can provide certicates of calibration for its whole product
range, to suit ISO 9000 and other quality assurance procedures, food hygiene regulations, HACCPs and environmental regulations. Comark
certicates are produced by independent quality controlled processes
which compare product performance against agreed National Stand­ards. For peace of mind and best practice Comark recommend annual
certication/recalibration.
Two levels of certication are available for infra-red temperature and non temperature instruments, excluding humidity:- UKAS certicates via an external accredited laboratory and NPL traceable certicates from
the Comark calibration laboratory.
Three levels of certication are available for contact temperature and
humidity products and these are detailed here:
a) UKAS Temperature Certication
The Comark UKAS (United Kingdom Accreditation Service)
accredited temperature calibration laboratory is one of the n­est in the UK. Comark UKAS certicates can offer the lowest
uncertainty of 0.01°C and provide independent proof of correct calibration using equipment and procedures audited by UKAS inspectors. The equipment used is fully traceable to the Na­tional Physical Laboratory.
b) UKAS Humidity Certication
In addition to the Comark temperature laboratory, the humidity
laboratory continues the tradition of high accuracy certication
and a wide range (25% to 90%RH) with uncertainties of 2.8% of reading. This range also includes Dew point measurements.
c) NPL Traceable Certication
Comark NPL certicates are traceable to the National Physical
Laboratory and can offer uncertainty as low as 0.3°C.
4
Conformance
Certicates of conformance can be supplied for new, serviced and recalibrated instruments. These conrm that instruments are within their original manufactured specication.
Service/Repairs
Regular servicing and any required repairs, under warranty or after, are available from the Comark Service Department.
For more information on all Comark certication, calibration and service
facilities please call Comark Customer Support or contact your local distributor.
5
1 INTRODUCTION
1.1 Transducer Input
The C9550 external pressure meter accepts all Comark pressure transducers model 3392, 3393, 3397 or 3398. Connection is made by means of the 8-pin socket and the 1.5 metre interface cable. An inbuilt serial interface allows the C9550 to communicate with the transducer and provide correct display of the pressure value in any one of the pressure units selected. Suitable pressure transducers are:
Model Pressure range, bar Diaphragm Type
3392/PG Series 0.1 to 4000 Internal Gauge 3393/PA Series 0.25 to 16 Internal Absolute 3397/PGF Series 0.1 to 600 Front Flush Gauge 3398/PAF Series 0.25 to 16 Front Flush Absolute
Table 1. Transducer Model References
1.2 Transducer Operator Manual
The separate Transducer Operator Manual provides details of the installation, troubleshooting and calibra­tion of transducers.
1.3 Transducer Range Data Sheet
Pressure ranges extend from 0.1 to 4000 bar. The separate Transducer Range Data sheet, Ref: C089, lists all pressure ranges available in each of Gauge / Absolute, Internal Diaphragm / Front Flush Diaphragm,
0.5% / 0.25% accuracy types.
1.4 Ranges, scales and resolutions
A tabular listing of the scales and resolutions of Comark stocked ranges is provided in section 5.3. The com­plete listing for all 24 ranges is available separately as Engineering Note 18, and is available from the Cus­tomer Service Department.
6