Code 3 Zenith User Manual

INSTALLATION GUIDE
Z1000
SOLID COLOR
TECHNICAL SPECIFICATIONS
SOLID COLOR:
INPUT VOLTAGE ........................10 to 30 Volts DC.
INPUT CURRENT .......................1.25A @ 12.8V, 0.6A @ 25.6V
LIGHT OUTPUT ...........................AMBER: 358+ LUMENS
BLUE: 240+ LUMENS GREEN: 312+ LUMENS RED: 358+ LUMENS CLEAR, PURPLE: 1100+ LUMENS
INPUT VOLTAGE .........................10 to 30 Volts DC.
INPUT CURRENT .......................0.6A @ 12.8V, 0.3A @ 25.6V
LIGHT OUTPUT ...........................AMBER: 180+ LUMENS
(For each 3 LED group) BLUE: 120+ LUMENS GREEN: 104+ LUMENS RED: 180+ LUMENS CLEAR: 550+ LUMENS
CABLE LENGTH ..........................9 FT.
LED ELEMENTS ..........................6
FLASH PATTERNS ......................16 (8 Standard, 8 optional cycle)
MAX NUMBER OF
SYNCHRONIZED HEADS ...........64
WARRANTY PERIOD ..................5 YEARS
DIMENSIONS
0.96"
1.50"
1.28"
SPLIT COLOR
0.92"
833 W. Diamond St Boise, Idaho 83705 TEL: 800-635-5900 www.eccogroup.com
MOUNTING
Drill a 1” diameter hole in the reector of the lens assembly. A 1” hole saw is typically used. The HIDE-A-LED™ may be used as a template to mark the location of the two screw holes. The Z1000 may be mounted in either the back surface, bottom or sides of a reector. Drill pilot holes with a 7/64” drill bit. Install the HIDE-A-LED™ into the lens assembly using the supplied gasket and screws. If the mount­ing surface is curved additional sealing may be necessary. Use RTV Silicone sealant if needed.
7/64” PILOT
REFLECTOR
HOLES
GASKET
1” HOLE
! HOT !
THE HEATSINK WILL BE HOT AFTER RUNNING FOR AN EXTENDED PERIOD. DO NOT TOUCH. IT WILL NOT MELT ANY OF THE PLASTIC PARTS OF THE LENS ASSEMBLY.
STRAP THE WATERPROOF POWER MODULE TO THE BODY OF THE VEHICLE AWAY FROM
ANY HIGH HEAT SOURCES.
DO NOT DRILL HOLES THROUGH THE POWER MODULE!
THE Z1000 HAS AN INTEGRATED HEATSINK WHICH MUST BE USED TO MAINTAIN A SAFE OPERATING TEMPERATURE.
! THE HEATSINK MUST NOT BE REMOVED !
THE HEATSINK CAN BE BENT INTO ANY SHAPE NEEDED TO FIT THE SPACE AVAILABLE FOR THE APPLICATION.
INTEGRATED HEATSINK
SCREWS
TIP: APPLY RTV SILICONE TO THE SCREWS TO SEAL THE THREADS.
4.83"
1.27"
0.94"
1.94"
CABLE
LED HEAD
0.48"
POWER MODULE
ITEMS INCLUDED
(1) HIDE-A-LED™ HEAD WITH INTEGRATED HEATSINK, BUILT IN POWER MODULE AND 9’ CABLE. (1) MOUNTING GASKET (2) #6 X 1/2” STAINLESS STEEL MOUNTING SCREWS
ELECTRICAL CONNECTIONS
The cable on the HIDE-A-LED™ was made long enough to run across the front or the rear of a vehicle. Trim the cable shorter if needed. The
wiring diagram on page 2 shows a typical install.
RED: +V
Connect to +V through an ON/OFF switch.
The use of a fuse located close to the voltage source is recommended. Size the fuse according to the number of heads used in the system.
18AWG or larger wire is recommended.
BLACK: - GROUND Connect to - GROUND vehicle chassis. 18AWG or larger wire is recommended.
BLUE: Flash pattern SYNC and SELECTION wire.
If you wish to have all the LED heads synchronize their ash timings and patterns with each other then all the BLUE wires must be connected together (64 Heads Maximum). The BLUE wire is also used to select the ash pattern. Touch the BLUE wire to +V to select the next pattern in the FLASH PATTERN LIST. The BLUE wire can also be run to a momentary push-button located on the dashboard to allow the ash pattern to be
changed when desired.
Note: Do not connect the BLUE wire to - Ground.
It will disrupt the ash pattern sync signal.
PAGE 1920-9120-00 REV. A
ELECTRICAL CONNECTIONS FLASH PATTERNS
YELLOW: Alternating / Simultaneous selection.
(It is assumed that all BLUE wires are connected together.)
Connect to either +V or GROUND (GND).
Heads with YELLOW connected to +V re at the same time. Heads with YELLOW connected to GND re at the same time. Heads with YELLOW connected to +V will ALTERNATE with heads that have
YELLOW connected to GND.
SPLIT COLOR HEADS:
Z1000 heads with 2 colors always alternate from side to side within themselves. The YELLOW wire reverses the direction so that two heads can either ash the same color at the same time or different colors at the same time.
BLUE
RED
The Z1000 will also synchronize with any HIDE-A-LED™ SD24 or BULL LED™ head. The wiring colors and functions are identical.
ELECTRICAL CONNECTIONS
INSTALLATION OF 4 HIDE-A-LED™ USING AN ON/OFF SWITCH AS WELL AS A MOMENTARY SWITCH TO SELECT FLASH PATTERNS (NOT SUPPLIED)
ALTERNATE FLASHING
YELLOW TO +V
YELLOW
RED
BLUE
RED
RED
TO - GND
BLACK
BLUE
FUSE
ON/OFF
YELLOW TO +V
BLACK
BLUE
YELLOW
CHASSIS GROUND
BLACK
PATTERN
SELECT
ALTERNATE FLASHING
ALTERNATE FLASHING
© 2010
RED
BLACK
BLUE
YELLOW
ORANGE
BLUE
BLACK
RED
YELLOW
YELLOW TO - GND
ALTERNATE FLASHING
POWER-UP RESET:
After installing the system it is best to do a POWER-UP RESET the rst time to ensure that all heads are in sync.
Touch BLUE wires to +V (RED wire) while applying power. Release BLUE wires. All heads will reset to Pattern #2.
If you have installed a pattern select push-button, press and hold pat­tern select while turning power switch ON.
To select a ash pattern, touch BLUE to +V or press pattern select switch to increment the ash pattern. The heads will remember the selected pattern even if power is removed.
STANDARD PATTERNS
# Pattern: Frequency: Description:
1 Quad Flash 1.25 Hz 75 Quad Flashes Per Minute
2 Double Flash 1.25 Hz 75 Double Flashes Per Minute
3 Triple Flash 1.53 Hz 92.3 Triple Flashes Per Minute
4 DeciBlast 1.42 Hz 85.5 Deci Flashes Per Minute
5 Single Flash 1.25 Hz 75 Single Flashes Per Minute
6 Mega Flash 1.90 Hz 114 Single Flashes Per Minute
STANDARD ONLY
7 Triple+Burst 1.37 Hz 82.5 Triple+Burst Flashes Per Minute
8 Steady On Steady on. Split Color = Fast Mega
CYCLE PATTERNS
9 Cycle All Cycle through patterns 1 to 7
STANDARD + CYCLE
10 Double-Triple+Burst 2 Double, 2 Triple+Burst cycle
11 Cycle Classic 1 Double, 1 Quad, 2 Mega cycle
12 Quad-Mega 3 Quad, 4 Mega cycle
13 Single-Quad 2 Single, 2 Quad cycle
14 DeciBlast-Quad 2 DeciBlast, 2 Quad cycle
15 Single-Triple-DeciBlast 2 Single, 2 Triple, 2 DeciBlast cycle
16 Mega-Triple+Burst 1 Mega, 1 Triple+Burst cycle
STANDARD PATTERNS:
The HIDE-A-LED™ ships with only the standard patterns enabled. To enable cycle ash patterns follow the procedure below.
CYCLE PATTERNS:
You may add patterns 9 through 16 by following this procedure:
1) Touch BLUE wires to +V (RED wire) while applying power.
If you have installed a pattern select push-button, press and hold pattern select
while turning power switch ON.
2) Hold BLUE wires on +V for 5 SECONDS (heads will not be ashing during this time). After 5 SECONDS the heads will ash once or twice to indicate the ash pattern list that has been selected:
ONE FLASH = Standard Patterns only. TWO FLASHES = Standard + Cycle Patterns.
3) Remove the BLUE wires from +V (or release push-button).
You may switch the pattern set at any time as many times as you wish. All
heads will remember the pattern set that was selected even when power is removed.
TROUBLESHOOTING
HEAD NOT FLASHING:
Check the RED and BLACK wires for a reversed connection. (Reverse connec­tion will not damage the unit). Check RED and BLACK wires for either a bad
splice or a corroded ground connection.
HEADS NOT SYNCHRONIZING:
Check for a short circuit on the BLUE wire to either +V or GROUND.
Saltwater on the wire connections will short circuit the sync signal on the BLUE
wire. Check for non-functional heads in the system. If any one of the heads has a bad GROUND connection it can cause the sync signal to become corrupted. If any one of the heads has it’s RED and BLACK wires reverse connected it will
corrupt the sync signal.
FLASH PATTERN CHANGING:
If the ash pattern changes on it’s own there may be an intermittent short be­tween the BLUE wire and +V. Check for water in the wiring connections. If any one of the heads in the system has an intermittent GROUND connection it can also cause the ash pattern to change.
PAGE 2920-9120-00 REV. A