Introduction
The HB Series LED light represents the latest in state-of-the-art LED warning technology. The latest in
MOSFET technology and advanced design provide efcient operation, superior performance, reliability and long life. The use of microprocessor control allows the HB Series to offer more light pattern options and versatility than any other remote system available. The user may select Single, Double, Triple, Quad, Variable Flash, Double-Double or Triple Flash Patterns.
Standard Features
The HB Series HIDE-A-BLAST LED light is available in a single unit package complete with installation instructions. Multiple HB Series LED Lights can be connected together and operated from the same control switch. All HB Series LED Lights have the following features:
12 OR 24 VDC OPERATION
REVERSE POLARITY PROTECTED
MULTIPLE USER SELECTABLE FLASH PATTERNS
See Flash Pattern Selection, page 6.
Note: A user supplied fuse must be installed in series with the red wire. Install the fuse near the power source. The fuse should be sized to the nearest standard size fuse that is approximately 125% of the combined total current of all HB Series LED Lights installed on the circuit. As an example, two HB Series LED Lights should be fused at 3A for 12VDC operation, 1A for 24V operation.
Specications
MODEL VARIANTS:
HB6PAKX & HB6PAKXX = 6 LEDs X denotes the LED color, Red, Blue, Amber or White (R, B, A or W) and dual color combinations of Amber/White, Red/Blue, Red/White or Blue/White (AW, BR, RW or BW). i.e. HB6PAKW has six white LEDs.
MECHANICAL SPECIFICATIONS:
CABLE LENGTH: 15 feet
DIMENSIONS: See gure A BOXED WEIGHT: 0.9lb UNBOXED WEIGHT: 0.8lb LED COLOR: Red, Blue, Amber or White (mixing of colors in the same unit is not supported)
LENS COLOR: clear
ELECTRICAL SPECIFICATIONS:
OPERATING VOLTAGE & POLARITY: 11-30VDC, Neg or Pos ground AVERAGE CURRENT: 0.6A @ 13.8VDC OPERATING TEMPERATURE: -30 to 150 F INPUT POWER: 8W OPERATING MODES: Synchronous and Non-Synchronous
!
WARNING!
The use of this or any warning device does not insure that all drivers can or will observe or react to an emergency warning signal. Never take the right-of-way for granted. It is your responsi­bility to be sure you can proceed safely before entering an intersection, driving against trac, responding at a high rate of speed, or walking on or around trac lanes. The eectiveness of this warning device is highly dependent upon correct mounting and wir­ing. Read and follow the manufacturer’s instructions before installing or using this device. The vehicle operator should insure daily that all features of the device operate correctly. In use, the vehicle operator should insure the projection of the warning signal is not blocked by vehicle components (i.e.: open trunks or compartment doors), people, vehicles, or other obstructions. This equipment is intended for use by authorized personnel only. It is the user’s responsibility to understand and obey all laws regarding emergency warning devices. The user should check all applicable city, state and federal laws and regulations. Public Safety Equipment, Inc., assumes no liability for any loss resulting from the use of this warning device. Proper installation is vital to the performance of this warning device and the safe operation of the emergency vehicle. It is important to recognize that the operator of the emergency vehicle is under psychological and physiological stress caused by the emergency situation. The warn­ing device should be installed in such a manner as to: A) Not reduce the output performance of the system, B) Place the controls within convenient reach of the operator so that one can oper­ate the system without losing eye contact with the roadway. Emergency warning devices often require high electrical voltages and/or currents. Properly pro­tect and use caution around live electrical connections. Grounding or shorting of electrical con­nections can cause high current arcing, which can cause personal injury and/or severe vehicle damage, including re. Do not touch the strobe light tubes, the strobe light head assemblies or the strobe power supply while the system is in operation. Wait 10 minutes after turning o the power from system before touching any internal componentry. PROPER INSTALLATION COMBINED WITH OPERATOR TRAINING IN THE PROPER USE OF EMER­GENCY WARNING DEVICES IS ESSENTIAL TO INSURE THE SAFETY OF EMERGENCY PERSONNEL AND THE PUBLIC.
Unpacking and Pre-installation
Remove the product from the box and examine the unit for any shipping damage. Report any damage to the carrier immediately. Inspect the contents to be certain that the following items are included:
A. 1 HB6PAK Series LED Light with 15 ft. Cable
B. 1 Installation Manual
3