This lightning flash with arrowhead symbol is intended to alert The user to
the presence of un-insulated “dangerous voltage”
Within the product’s enclosure that may be of sufficient magnitude
To constitute a risk of electric shock to
ersons.
This exclamation point symbol is intended to alert the user to
The presence of important operating and maintenance (servicing)
instructions in the literature accom
the appliance.
~ Important Safety Instructions
Read Instructions
• Read all of the safety and operation instructions before using the product.
Retain Instructions
• Save these instructions for future reference.
Attachments / Accessories
• Do not use attachments or accessories unless recommended by the appliance manufacturer as they may cause hazards, damage product
and void warranty.
Installation
• Do not place or mount this product in or on an unstable or improperly supported location. Improperly installed product may fall, causing
serious injury to a child or adult, and damage to the product. Use only with a mounting device recommended by the manufacturer, or
sold with the product. To insure proper mounting, follow the manufacturer’s instructions and use only mounting accessories.
recommended by manufacturer.
Power source
• This product should be operated only from the type of power source indicated on the marking label.
~ Precautions
Operating
• Before using, make sure power supply and others are properly connected.
• While operating, if any abnormal condition or malfunction is observed, stop using the camera immediately and then contact your local
dealer.
Handling
• Do not disassemble or tamper with parts inside the camera.
• do not drop or subject the camera to shock and vibration as this can damage camera.
• Care must be taken when you clean the clear dome cover. Especially, scratch and dust will ruin your quality of camera.
Installation and Storage
• Do not install the camera in areas of extreme temperature, which exceed the allowable range.
• Avoid installing in humid or dusty places.
• Avoid installing in places where radiation is present.
• Avoid installing in places where there are strong magnetic fields and electric signal.
• Avoid installing in places where the camera would be subject to strong vibrations.
2
XPEED Indoor Series WWW.CNBTEC.COM
~ Table of Contents
1. Introduction
Features 4
Product & Accessories 5
Parts Name & Functions 6
2. Installation
Dip Switch Setup 8
Installation Using the Wall Mount 10
Installation Using the Pendant Mount 11
Wire Connections 14
3. Operation
Check Points before Operation 16
Preset and Pattern Function Pre-Check 16
Starting OSD Menu 16
Reserved Preset 16
Preset 17
Swing 17
Pattern 17
Group 18
Other Functions 18
4. OSD Menu
OSD Display of Main Screen 19
General Rules of key Operation for Menu 20
Main Menu 20
Display Setup 20
Privacy Zone Mask Setup ( 26x (S1465N(P)X), 36x (S1965N(P)X) EXview 27x(SBN-22Z27F /SBN-23Z27F) (Option) Models Only ) 21
Camera Setup (27x (SBN-22Z27F /SBN-23Z27F(P) models) 22
Camera Setup (26x (S1465N(P)X), 36x (S1965N(P)X ) EXview Models) 24
Motion Setup 26
Preset Setup 27
Swing Setup 29
Patten Setup 30
Group Setup 31
System Initialize 33
5. Specifications
26x (S1465N(P)X) EXview Models 34
27x (SBN-22Z27F/SBN-23Z27F) Models 35
36x (S1965N(P)X) EXview Models 36
Dimensional Drawings 37
3
XPEED Indoor Series WWW.CNBTEC.COM
1. Introduction
~ Features
Camera Specifications
• Image Pick-up Device: 1/4" Interline Transfer CCD
• Zoom Magnification: 26x Optical Zoom, 12x Digital Zoom (Max. 312x Zoom) → Model S1465N(P)X
27x Optical Zoom, 10x Digital Zoom (Max. 270x Zoom) → Model SBN-22Z27F /SBN-23Z27F
36x Optical Zoom, 12x Digital Zoom (Max. 432x Zoom) → Model S1965N(P)X
• Day & Night Function
• Various Focus Mode : Auto-Focus / Manual Focus / SemiAuto Focus.
• Each Preset has its own video configuration, label, relay output setting values.
You can adjust each Preset setting independently.
Powerful Pan/Tilt Functions
• Max. 360°/sec high speed pan/Tilt Movement
• Using Vector Drive Technology, Pan/Tilt motions are accomplished in a shortest path. As a result, time to target view is reduced
dramatically and the video on the monitor is very natural to watch.
• For jog operation using a controller, since ultra slow speed 0.05°/sec can be reached, it is very easy to locate camera to desired target view.
Additionally it is easy to move camera to a desired position with zoom-proportional pan/tilt movement.
Preset, Pattern, Swing, Group, Privacy Mask and More...
• Max. 127 Presets are assignable and characteristics of each preset can be set up independently, such as white Balance, Auto Exposure, Label,
Digital Outputs and so on.
• Max. 8 set of Swing action can be stored. This enables to move camera repetitively between two preset positions with designated speed.
• Max. 4 of patterns can be recorded and played back. This enables to move camera to follow any trajectory operated by joystick as closely as
possible.
• Max. 8 set of Group action can be stored. This enables to move camera repetitively with combination of preset or pattern or Swing. A Group is
composed of Max. 20 entities of Preset/Patten/Swings.
• Privacy Masks are assignable, not to intrude on other’s privacy. (8 Privacy Zones)
→ Only available with Models S1465N(P)X, S1965N(P)X, SBN-22Z27F /SBN-23Z27F (option)
PTZ(Pan/Tilt/Zoom) Control
• With RS-485 communication, Max. 255 of cameras can be controlled at the same time.
• Pelco-D, Pelco-P, Samsung or Panasonic protocol can be selected as a control protocol in the current version of firmware.
OSD(On Screen Display) Menu
• OSD menu is provided to display the status of camera and to configure the functions interactively.
• The information such as Camera ID, Pan/Tilt Angle, Alarm I/O and Preset can be displayed on screen.
Alarm I/O Functions
• 4 alarm sensor inputs and 2 alarm Output relays are available.
• To reject external electric noise and shock perfectly, alarm sensor Input is decoupled with photo coupler and the relay is used for alarm output.
• The signal range of sensor input is from DC 5.0 to 12.0 volts to adopt various applications. Meanwhile, the maximum load of relay contact is
250VAC, 3A or 28VDC, 3A.
• If an external sensor is activated, camera con be set to move to the corresponding Preset position. Meanwhile, the output relay can be
matched to some specific preset positions to do counteractions such as turning on the light or sound the alarm.
Reserved Presets for Special Purpose
• Most camera characteristics can be set up easily and directly with reserved preset, not entering into OSD menu. For more information, refer to
“Reserved Preset” in this manual.
Easy Installation and Perfect Outdoor Environment Compatibility
• Fans and heaters are built-in camera for cold and hot temperature environment.
Also idealistic mechanical design protects camera from water and dust. (IP 66)
• It is easy to install and maintain camera with terminal for cable connection in brackets.
4
XPEED Indoor Series WWW.CNBTEC.COM
1. Introduction
⊙ Product & Accessories
■ Basic Components
■ Other Components (available to be ordered separately)
5
XPEED Indoor Series WWW.CNBTEC.COM
1. Introduction
⊙ Parts Name & Functions
① Bubble If the bubble is damaged or soiled by scratching or foreign matters, the damaged/dirty part will be visible on
the screen.
Therefore, do not undo the protective cover until the installation is complete.
② Mounting Base The mounting base is to used to install the camera onto the ceiling or camera brackets.
Disassemble the mounting base first and install it onto ceiling or brackets and then assemble it with the main
body.
③ Anti-drop
Spring & Hook
④ TORX Screw When the main body and the mounting base are assembled, be sure to insert the screw to the mounting base,
⑤ Fuse If a fuse is blown by over-voltage current, change it with a new one, and contact the manufacturer or dealer to
⑥ Cabling
Terminal Block
⑦ MainConnector With this connector, I/O board mounting base and the dome drive are connected.
⑧ Mounting Hole Fastening the mounting base to the ceiling or camera brackets using the three mounting screws provided.
This is used to prevent the main body of camera from dropping during installation.
Attach the anti-drop spring to the hook when assembling the main body to the mounting base.
otherwise there is a risk of the main body dropping from the mounting base by vibration, jarring or movement.
check the cause of the over-voltage and remove it.
The breaking capacity of a fuse is 250V, 2A
During installation, Power, Video, Communication, Alarm I/O cables are connected on to this cabling terminal
block.
6
XPEED Indoor Series WWW.CNBTEC.COM
1. Introduction
⊙ Disassembling the Mounting Base
⊙ Assembling the Mounting Base
7
XPEED Indoor Series WWW.CNBTEC.COM
2. Installation
9 Before installing the camera, you should set the DIP switches to configure the camera ID, communication protocol. Do not use the
system upgrade terminal.
~ DIP Switch Setup
■ Camera ID Setup
■ Communication Protocol Setup
• ID number of camera is set using binary number.
The example is shown bellow.
Pin 1 2 3 4 5 6 7 8
ID Value 1 2 4 8 16 32 64 128
ex) ID=5 ON OFF ON OFF OFF OFF OFF OFF
Ex) ID=10 OFF ON OFF ON OFF OFF OFF OFF
• The range of ID 1~255. Do not use 0 as camera ID.
• Factory default of Camera ID is 1.
• If you want to control a certain camera, you must match the camera ID with Cam ID setting of
DVR or Controller.
• Select the appropriate Protocol With DIP switch combination.
Switch state
Protocol/Baud rate
P0 (Pin 1) P1(Pin 2) P2(Pin 3)
OFF OFF OFF PELCO-D, 2400bps
ON OFF OFF PELCO-D, 9600bps
8
OFF ON OFF PELCO-P, 4800bps
ON ON OFF PELCO-P, 9600bps
OFF OFF ON SAMSUNG, 4800bps
ON OFF ON PANASONIC, 9600bps
Others Reserved
XPEED Indoor Series WWW.CNBTEC.COM
• If you want to control using DVR or P/T controller, their protocol must be identical to camera.
Otherwise, you can not control the camera.
• It you changed camera protocol by changing DIP S/W, the change will be effective after you
reboot the camera.
• Factory default of protocol is “Pelco-D, 2400bps”.
■ Input Sensor Active Type
• When a sensor input is used, its functional type should be set.
There are two types; Normal Open type and Normal Close type.
-Normal Open : Voltage is let out when the sensor is activated
-Normal Close : Voltage is let out when the sensor is not activated
Pin Switch position Sensor type
ST1 (Pin 4)
ST2 (Pin 5)
ST3 (Pin 6)
ST4 (Pin 7)
• If a wrong type of sensor is selected, it activates in the opposite way to the sensor input.
ON Sensor 1 Normal Close
OFF Sensor 1 Normal Open
ON Sensor 2 Normal Close
OFF Sensor 2 Normal Open
ON Sensor 3 Normal Close
OFF Sensor 3 Normal Open
ON Sensor 4 Normal Close
OFF Sensor 4 Normal Open
■ Termination Switch Setting
Termination switch (Pin 4) is used in cases listed below.
• Long-distance communication between the controller and the camera (1-to-1 connection)
When the connection distance between the two units is especially long, communication errors
may occur due to the impedance of transmission cable. In this case, set the termination switch
of both units to ON.
• Controlling multiple cameras (Multiple connection)
The camera may not operate correctly if multiple cameras are connected and controlled. In this
case, set the termination switch of the controller and the last connected camera to ON and the
switch of other cameras is OFF.
Ex) Using the Terminating Resistance.
Termination Switch ON
9
XPEED Indoor Series WWW.CNBTEC.COM
2. Installation
⊙ Installation Using the Wall Mount
10
XPEED Indoor Series WWW.CNBTEC.COM
2. Installation
⊙ Installation Using the Pendant Mount
11
XPEED Indoor Series WWW.CNBTEC.COM
2. Installation
⊙ Installation using the Pendant Mount