1. GENERAL DESCRIPTION
1.1 OVERVIEW
V370H1-L03 is a 37” thin-film-transistor liquid-crystal (TFT-LCD) module with 20-CCFL Backlight unit and
2ch-LVDS interface. This module supports 1920 x 1080 HDTV format and can display true 16.7M colors
(8-bit/color). The inverter module for backlight is built-in.
1.2 FEATURES
- Ultra wide viewing angle – Super MVA technology
- High brightness (600 nits)
- High contrast ratio (1000:1)
- Fast response time (8 ms)
- High color saturation (NTSC 75%)
www.panelook.com
Issued Date:Nov,30 2005
Model No.: V370H1-L03
Approval
- HD (1920 x 1080 pixels) resolution
- DE (Data Enable) only mode
- LVDS (Low Voltage Differential Signaling) interface
1.3 APPLICATION
- TFT LCD TVs
1.4 GENERAL SPECIFICATI0NS
Item Specification Unit Note
Active Area 820.8 (H) x 461.7 (V) (37” diagonal) mm
Bezel Opening Area 828.8 (H) x 470.9 (V) mm
Driver Element a-si TFT active matrix - Pixel Number 1920x R.G.B. x 1080 pixel Pixel Pitch(Sub Pixel) 0.1425 (H) x 0.4275 (V) mm Pixel Arrangement RGB vertical stripe - Display Colors 16.7M color Display Operation Mode Transmissive mode / Normally black - -
Anti-reflective coating
Surface Treatment
Note (1) Please refer to the attached drawings in chapter 9 for more information about the front and
Hard coating (3H)
Reflection rate : < 2%
- (2)
(1)
back outlines.
Note (2) The spec of the surface treatment is temporarily for this phase. CMO reserves the rights to
change this feature.
1.5 MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note
Horizontal(H) 884.1 884.8 885.5 mm
Module Size
Vertical(V) 525.0 525.9 526.8 mm
Depth(D) 43.34 44.34 45.34 mm To PCB cover
Depth(D) 50.74 52.24 53.74 mm To inverter cover
Weight 8950 9150 9350 g
4
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.1
www.panelook.com
Global LCD Panel Exchange Center
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item Symbol
Storage Temperature TST -20 +60 ºC (1)
Operating Ambient Temperature TOP 0 50 ºC (1), (2)
Shock (Non-Operating) S
Vibration (Non-Operating) V
Note (1) Temperature and relative humidity range is shown in the figure below.
www.panelook.com
Issued Date:Nov,30 2005
Model No.: V370H1-L03
Approval
Value
Min. Max.
- 50 G (3), (5)
NOP
- 1.0 G (4), (5)
NOP
Unit Note
(a) 90 %RH Max. ( Ta
(b) Wet-bulb temperature should be 39 ºC Max. ( Ta > 40 ºC ).
(c) No condensation.
Note (2) The maximum operating temperature is based on the test condition that the surface temperature of
display area is less than or equal to 60 ºC with LCD module alone in a temperature controlled chamber.
Thermal management should be considered in your product design to prevent the surface temperature
of display area from being over 60 ºC. The range of operating temperature may degrade in case of
improper thermal management in your product design.
Note (3) 11 ms, half sine wave, 1 time for ± X, ± Y, ± Z.
Note (4) 10 ~ 200 Hz, 10 min, 1 time each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough so that
the module would not be twisted or bent by the fixture. The module would not be twisted or bent by the
fixture.
Љ 40 ºC ).
Relative Humidity (%RH)
100
90
80
60
Operating Range
40
20
10
Storage Range
Temperature (ºC)
5
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
8060-20 400 20-40
Version2.1
www.panelook.com
Global LCD Panel Exchange Center
2.2 ELECTRICAL ABSOLUTE RATINGS
2.2.1 TFT LCD MODULE
www.panelook.com
Issued Date:Nov,30 2005
Model No.: V370H1-L03
Approval
Item Symbol
Min. Max.
Power Supply Voltage VCC -0.3 20 V
Logic Input Voltage VIN -0.3 3.6 V
Note: (1) Permanent damage to the device may occur if maximum values are exceeded. Functional
operation should be restricted to the conditions described under normal operating conditions.
Value
Unit Note
(1)
2.2.2 BACKLIGHT UNIT
Item Symbol
Lamp Voltage VW
Power Supply Voltage VBL 0 30 V
Control Signal Level
Note (1) Permanent damage to the device may occur if maximum values are exceeded. Function operation
should be restricted to the conditions described under Normal Operating Conditions.
Note (2) No moisture condensation or freezing.
Note (3) The control signals includes On/Off Control, Internal PWM Control
Ё
Val ue
Min.Max.
Ё
-0.3 7 V
3000 V
Unit Note
RMS
(1)
(1), (3)
6
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.1
www.panelook.com
Global LCD Panel Exchange Center
3. ELECTRICAL CHARACTERISTICS
www.panelook.com
Issued Date:Nov,30 2005
Model No.: V370H1-L03
Approval
3.1 TFT LCD MODULE
Parameter Symbol
Ta = 25 ± 2 ºC
Value
Min. Typ. Max.
Unit Note
Power Supply Voltage VCC 16.2 18 19.8 V (1)
Power Supply Ripple Voltage VRP - - 200 mV
Rush Current I
- - 3.5 A (2)
RUSH
White - 0.80 - A
Power Supply Current
Differential Input High
LVDS
Interface
Threshold Voltage
Differential Input Low
Threshold Voltage
Common Input Voltage V
Terminating Resistor R
Black - 0.45 - A
Vertical Stripe
ICC
(3)
- 0.65 - A
- - +100 mV
V
LVT H
-100 - - mV
V
LVTL
1.125 1.25 1.375 V
LVC
- 100 - ohm
T
Input High Threshold Voltage VIH 2.7 - 3.3 V CMOS
interface
Input Low Threshold Voltage V
0 - 0.7 V
IL
Note: (1) The module should be always operated within the above ranges.
(2) Measurement condition:
+18.0V
R1
47K
Q1 2SK1475
FUSE
C3
1uF
Vcc
(LCD Module Input)
(High to Low)
(Control Signal)
SW
+12V
R2
1K
47K
VR1
C1
1uF
0.01uF
Q2
2SK1470
C2
Vcc rising time is 470us
+18V
0.9Vcc
0.1Vcc
GND
470us
7
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.1
www.panelook.com
Global LCD Panel Exchange Center
Note (3) The specified power supply current is under the conditions at Vcc = 18 V, Ta = 25 ± 2 ºC, fv = 60 Hz,
whereas a power dissipation check pattern below is displayed.
www.panelook.com
Issued Date:Nov,30 2005
Model No.: V370H1-L03
Approval
a. White Pattern
Active Area
c. Vertical Stripe Pattern
b. Black Pattern
Active Area
R
G
R
B
G
B
B
R
R
G
G
B
B
R
R
Active Area
B
RR
G
G
B
B
R
G
G
B
B
R
.
8
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Operating Frequency Fo 40 - 70 KHz (3)
Lamp Life Time LBL 50,000 - - Hrs (4)
3.2.2 INVERTER CHARACTERISTICS (Ta =25
Parameter Symbol
Min. Typ. Max.
2кккк
)
Val ue
Unit Note
Power consumption PBL - 140 - W (5), IL = 4.8mA
Power Supply Voltage VBL 22.8 24 25.2 VDC
Power Supply Current IBL - 5.8 - A Non Dimming
Input Ripple Noise - -
VBS 2780 - - V
- 500
mVp-pVBL=22.8V
RMS
Ta = 0 ºC
Backlight Turn on Voltage
- 2440 - - V
Ta = 25 ºC
RMS
Oscillating Frequency FW 51 54 57 kHz
Dimming frequency FB 150 160 170 Hz
Minimum Duty Ratio D
- 20 - %
MIN
Note (1) Lamp current is measured by utilizing high frequency current meters as shown below:
9
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.1
www.panelook.com
Global LCD Panel Exchange Center
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
LCD
Module
www.panelook.com
HV (Pink,+)
HV (White,+)
HV (Pink,-)
HV (White,-)
HV (Pink,+)
HV (White,+)
HV (Pink,-)
HV (White,-)
HV (Pink,+)
HV (White,+)
HV (Pink,-)
HV (White,-)
HV (Pink,+)
HV (White,+)
HV (Pink,-)
HV (White,-)
HV (Pink,+)
HV (White,+)
Issued Date:Nov,30 2005
Model No.: V370H1-L03
Approval
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Inverter
A
A
HV (Pink,-)
HV (White,-)
1
2
Return Cable
Note (2) The lamp starting voltage V
should be applied to the lamp for more than 1 second under starting
S
up duration. Otherwise the lamp could not be lighted on completely.
Note (3) The lamp frequency may produce interference with horizontal synchronous frequency from the
display, and this may cause line flow on the display. In order to avoid interference, the lamp
frequency should be detached from the horizontal synchronous frequency and its harmonics as far
as possible.
Note (4) The life time of a lamp is defined as when the brightness is larger than 50% of its original value and
the effective discharge length is longer than 80% of its original length (Effective discharge length is
defined as an area that has equal to or more than 70% brightness compared to the brightness at
the center point.) as the time in which it continues to operate under the condition
Ta = 25
2к and I
= 4.3~5.3mA
L
RMS
.
Note (5) The power supply capacity should be higher than the total inverter power consumption P
10
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
. Since
BL
Version2.1
www.panelook.com
Global LCD Panel Exchange Center
X
the pulse width modulation (PWM) mode was applied for backlight dimming, the driving current
changed as PWM duty on and off. The transient response of the power supply should be
considered for the changing loading when inverter dimming.
3.2.3 INVERTER INTERTFACE CHARACTERISTICS
Parameter Symbol
On/Off Control Voltage
Voltage
Control Signal Rising Time Tr
Control Signal Falling Time Tf
Input impedance RIN
BLON Delay Time1 T
BLON Off Time1 T
Note (1) The power sequence and control signal timing are shown in the following figure.
ON
OFF
MA
MIN
www.panelook.com
Issued Date:Nov,30 2005
Model No.: V370H1-L03
Te st
Condition
V
BLON
V
IPWM
Ё 1 Ё Ё ms
on1
Ё 1 Ё Ё ms
off1
Ё
Ё
Ё
Ё Ё Ё
Ё Ё Ё
Ё
Min.Typ.Max.
2.0
Val ue
Ё
0
ЁЁ
Ё
1
Ё
Ё Ё MӨ
Unit Note
5.0V
0.8V
3.0Vmaximum duty ratioInternal PWM Control
0
Ё
100 ms
100 ms
Vminimum duty ratio
Approval
Note (2) The power sequence and control signal timing must follow the figure below. For a certain reason,
the inverter has a possibility to be damaged with wrong power sequence and control signal timing.