Polarizer (CF side) Super Wide View Anti-glare coating, 709.7(H) x 405(W)
Polarizer (TFT side) Super Wide View, 709.7(H) x 405(W).
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
1366
768
(Typical value measured at CMO’s module: V315B6-L01)
(Typical value measured at CMO’s module: V315B6-L01)
G=0.278, 0.597
B=0.145, 0.068
W=0.285, 0.293
(Typical value measured at CMO’s module: V315B6-L01)
5.8%Typ.
(Typical value measured at CMO’s module: V315B6-L01)
Hardness:2H
1.3 MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note
Weight 1150 g I/F connector mounting
position
Note (1) Please refer to the attached drawings for more information of front and back outline dimensions.
(2) Connector mounting position
The mounting inclination of the connector makes
the screen center within ±0.5mm as the horizontal.
+/- 0.5mm
4
(2)
Version2.0
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT (BASED ON CMO MODULE V315B6-L02)
Item Symbol
Storage Temperature TST -20 +60 ºC (1), (3)
Operating Ambient Temperature TOP 0 50 ºC (1), (2), (3)
Altitude Operating A OP 0 5000 M (3)
Altitude Storage A ST 0 12000 M (3)
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Љ 40 ºC).
Relative Humidity (%RH)
100
90
80
Min. Max.
Value
Unit Note
Note (2) The maximum operating temperature is based on the test condition that the surface temperature
of display area is less than or equal to 65 ºC with LCD module alone in a temperature controlled
chamber. Thermal management should be considered in your product design to prevent the
surface temperature of display area from being over 65 ºC. The range of operating temperature
may degrade in case of improper thermal management in your product design.
60
40
20
10
Operating Range
Storage Range
Temperature (ºC)
8060-20 400 20-40
Note (3) The rating of environment is base on LCD module. Leave LCD cell alone, this environment condition
can’t be guaranteed. Except LCD cell, the customer has to consider the ability of other parts of LCD
module and LCD module process.
5
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
2.2 ABSOLUTE RATINGS OF ENVIRONMENT (OPEN CELL)
Storage Condition: With shipping package.
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
Storage temperature range: 25±5
Storage humidity range: 50±10%RH
Shelf life: a month
2.3 ELECTRICAL ABSOLUTE RATINGS
2.3.1 TFT LCD OPEN CELL
Item Symbol
Power Supply Voltage Vcc -0.3 13.0 V
Input Signal Voltage VIN -0.3 3.6 V
Note (1) Permanent damage to the device may occur if maximum values are exceeded. Functional
operation should be restricted to the conditions described under normal operating conditions.
к
Value
Min. Max.
Unit Note
(1)
6
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
3. ELECTRICAL CHARACTERISTICS
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
3.1 TFT LCD OPEN CELL
Parameter Symbol
Ta = 25 ± 2ºC
Value
Min. Typ. Max.
Unit Note
Power Supply Voltage VCC 11.4 12.0 12.6 V (1)
Power Supply Ripple Voltage VRP - - 100 mV
Rush Current I
- - 3.9 A (2)
RUSH
White - 0.45 0.52 A
Power Supply Current
Differential Input High
LVDS
Interface
Threshold Voltage
Differential Input Low
Threshold Voltage
Common Input Voltage V
Terminating Resistor R
Black - 0.33 - A
Vertical Stripe
ICC
(3)
- 0.45 - A
- - +100 mV
V
LVT H
-100 - - mV
V
LVTL
1.125 1.25 1.375 V
LVC
- 100 - ohm
T
Input High Threshold Voltage VIH 2.7 - 3.3 V CMOS
interface
Input Low Threshold Voltage V
0 - 0.7 V
IL
Note (1) The module should be always operated within above ranges.
Note (2) Measurement Conditions:
+12.0V
Q1 Si4435DY
FUSE
R1
1K
C3
1uF
Vcc
(LCD Module Input)
VR1
(Low to High)
(Control Signal)
SW
R2
1K
47K
Q2
2N7002
C1
0.01uF
Vcc rising time is 470us
+12V
0.9Vcc
0.1Vcc
GND
470us
7
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
Note (3) The specified power supply current is under the conditions at Vcc =12V, Ta = 25 ± 2 ºC, fv = 60
Hz, whereas a power dissipation check pattern below is displayed.
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
a. White Pattern
Active Area
c. Vertical Stripe Pattern
b. Black Pattern
Active Area
R
G
R
B
G
B
B
R
R
G
G
B
B
R
R
Active Area
B
RR
G
G
B
B
R
G
G
B
B
R
8
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
(+/
)
4. BLOCK DIAGRAM
4.1 TFT LCD OPEN CELL
RX0(+/-)
RX1(+/-)
RX2(+/-)
RX3(+/-)
RXCLK
-
Vcc
GND
P-TWO 187053-30091)
093G30-B0001A or
(STARCONN
INPUT CONNECTOR
www.panelook.com
FRAME BUFFER
TIMING
CONTROLLER
DC/DC CONVERTER &
REFERENCE VOLTAGE
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
SCAN DRIVER IC
TFT LCD PANEL
(1366x3x768)
DATA DRIVER IC
9
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
5. INTERFACE PIN CONNECTION
5.1 TFT LCD OPEN CELL
CNF1 Connector Pin Assignment
Pin No. Symbol Description Note
1 VCC Power supply: +12V
2 VCC Power supply: +12V
3 VCC Power supply: +12V
4 VCC Power supply: +12V
5 GND Ground
6 GND Ground
7 GND Ground
8 GND Ground
9 SELLVDS Select LVDS data format (2)
10 ODSEL Overdrive Lookup Table Selection (3)
11 GND Ground
12 RX0- Negative transmission data of pixel 0
13 RX0+ Positive transmission data of pixel 0
14 GND Ground
15 RX1- Negative transmission data of pixel 1
16 RX1+ Positive transmission data of pixel 1
17 GND Ground
18 RX2- Negative transmission data of pixel 2
19 RX2+ Positive transmission data of pixel 2
20 GND Ground
21 RXCLK- Negative of clock
22 RXCLK+ Positive of clock
23 GND Ground
24 RX3- Negative transmission data of pixel 3
25 RX3+ Positive transmission data of pixel 3
26 GND Ground
27 NC No connection (4)
28 NC No connection (4)
29 GND Ground
30 GND Ground
Note (1) Connector type: STARCONN 093G30-B0001A or P-TWO 187053-30091 or compatible
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
Note (2) Ground or OPEN: VESA, High: JEIDA LVDS format
Please refer to 5.3 LVDS INTERFACE
Note (3) Overdrive lookup table selection. The Overdrive lookup table should be selected in accordance to the
frame rate to optimize image quality.
ODSEL Note
L or Open Lookup table was optimized for 60 Hz frame rate.
H Lookup table was optimized for 50 Hz frame rate.
Note (4) Reserved for internal use. Left it open.
10
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
5.2 BLOCK DIAGRAM OF INTERFACE
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
CNF1
Rx0+
-
R0-R7
-
-
Rx1+
Rx1-
Rx2+
-
Rx3+
-
Host
Graphics
Controller
CLK+
-
LVDS Transmitter
THC63LVDM83A
(LVDF83A)
51
Ө
100pF
51
Ө
51
Ө
51
51
51
51
51
51
51
100pF
Ө
Ө
100pF
Ө
Ө
100pF
Ө
Ө
100pF
Ө
LVDS Receiver
THC63LVDF84A
RxOUT
R0-R7
-
-
DCLK
Timing
Controller
R0~R7 : Pixel R Data
G0~G7 : Pixel G Data
B0~B7 : Pixel B Data
DE : Data enable signal
Note (1) The system must have the transmitter to drive the module.
Note (2) LVDS cable impedance shall be 50 ohms per signal line or about 100 ohms per twist-pair line when it is
used differentially.
11
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
5.3 LVDS INTERFACE
SELLVDS = L or Open (VESA)
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
SELLVDS = H (JEIDA)
R0~R7: Pixel R Data (7; MSB, 0; LSB)
G0~G7: Pixel G Data (7; MSB, 0; LSB)
B0~B7: Pixel B Data (7; MSB, 0; LSB)
DE : Data enable signal
Note (1) RSVD(reserved)pins on the transmitter shall be “H” or( “L” or OPEN)
12
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
5.4 COLOR DATA INPUT ASSIGNMENT
The brightness of each primary color (red, green and blue) is based on the 8-bit gray scale data input
for the color. The higher the binary input, the brighter the color. The table below provides the assignment
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
RXCLK+/-
RXn+/-
Tlvsu
Tlvhd
1T
14
LVDS RECEIVER INTERFACE TIMING DIAGRAM
Tc
3T
14
5T
14
7T
14
9T
14
11T
14
13T
14
15
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
6.2 POWER ON/OFF SEQUENCE
To prevent a latch-up or DC operation of LCD module, the power on/off sequence should be as
the diagram below.
Power Supply
V
0.5
0
0
500ms
ЉЉЉЉ
ЉЉЉЉ
ЉЉЉЉ
CC
T
1
ЉЉЉЉ
10ms
T
2
ЉЉЉЉ
50ms
T
3
ЉЉЉЉ
50ms
ЉЉЉЉ
0V
T4
LVDS Signals
0V
0
ЉЉЉЉ
T
7
ЉЉЉЉ
ЉЉЉЉ
T2
T
8
ЉЉЉЉ
T3
0
Option Signals
(SELLVDS, ODSEL)
www.panelook.com
0.9 V
CC
0.1V
CC
2
T
Power On
T7
VALI D
3
T1
T
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
CC
0.9 V
cc
0.1V
T4
Power Off
8
T
Backlight (Recommended)
500ms
100ms
ЉЉЉЉ
ЉЉЉЉ
T5
T
6
50%
5
T
50%
T
6
Note (1) The supply voltage of the external system for the module input should follow the definition of Vcc.
Note (2) Apply the lamp voltage within the LCD operation range. When the backlight turns on before the LCD
operation or the LCD turns off before the backlight turns off, the display may momentarily become
abnormal screen.
Note (3) In case of Vcc is in off level, please keep the level of input signals on the low or high impedance.
T2<0, that maybe cause electrica l overstress failures.
Note (4) T4 should be measured after the module has been fully discharged between power off and on period.
Note (5) Interface signal shall not be kept at high impedance when the power is on.
Power ON/OFF Sequence
If
16
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
7. OPTICAL CHARACTERISTICS
7.1 TEST CONDITIONS
Item Symbol Value Unit
Ambient Temperature Ta
Ambient Humidity Ha
Supply Voltage VCC 5.0 V
Input Signal According to typical value in "3. ELECTRICAL CHARACTERISTICS"
Inverter Current IL
Inverter Driving Frequency FL
7.2 OPTICAL SPECIFICATIONS
The relative measurement methods of optical characteristics are shown as below. The following items
should be measured under the test conditions described in 7.1 and stable environment shown in Note (5).
Item SymbolCondition Min. Typ. Max. UnitNote
Red
Color
Chromaticity
Center Transmittance T%
Contrast Ratio CR
Response Time
White Variation
Viewing Angle
Green
Blue
White
Gray to
average
Horizontal
Vertical
www.panelook.com
25±2
50±10
0.5
10.5
3
63
Rx
Ry 0.332
Gx
Gy 0.597
Bx
By 0.068
Wx
Wy
gray
δW
θx+
-
θ
x
θY+
θ
-
Y
=0°, θY =0°
θ
x
˩˼˸˼˺ʳ˴˺˿˸ʳ˴ʳ˴˿ʳ
˷˼˸˶˼
With CMO module
θ
=0°, θY =0°
x
With CMO Module
θ
=0°, θY =0°
x
With CMO
Module@60Hz
=0°, θY =0°
θ
x
With CMO Module
CR≥20
With CMO Module
Typ.-0.03
- 5.8 % (1), (7)
2000 3000- (1), (3)
-
1.5 - (1), (6)
80 88 80
80
80
0.643
0.278
0.145
0.285
0.293
6.5 12
88 88 88 -
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
o
C
%RH
mA
KHz
-
-
-
Typ+0.03
(1),(5)
-
-
-
-
ms (4)
Deg. (1), (2)
Note (1) Light source is CMO’s BLU and driving voltages are based on suitable gamma voltages. The calculated
method is as following:
1. Measure module’s and backlight’s spectrum. White and R, G, B are with signal input.
2. Calculate cell’s spectrum.
Note (2) Definition of Viewing Angle (θx, θy):
Viewing angles are measured by EZ-Contrast 160R (Eldim)
17
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
T
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
Note (3) Definition of Contrast Ratio (CR):
θX- = 90º
6 o’clock
θ
y-
= 90º
The contrast ratio can be calculated by the following expression.
Contrast Ratio (CR) = L255 / L0
x-
y-
Normal
θx = θy = 0º
θy-θy+
θx−
θx+
y+
12 o’clock direction
θ
y+
= 90º
x+
θX+ = 90º
L255: Luminance of gray level 255
L 0: Luminance of gray level 0
CR = CR (5), where CR (X) is corresponding to the Contrast Ratio of the point X at the figure in Note
(6).
Note (4) Definition of Gray-to-Gray Switching Time:
Optical
Response
The driving signal means the signal of luminance 0%, 20%, 40%, 60%, 80%, 100%.
100%
90%
10%
0%
Gray to gray
Switching time
Gray to gray
Switching time
ime
Gray to gray average time means the average switching time of luminance 0%, 20%,
40%, 60%, 80%, 100% to each other.
Note (5) Measurement Setup:
The LCD module should be stabilized at given temperature for 60 minutes to avoid abrupt
18
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 60 minutes in a windless room.
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
Note (6) Definition of White Variation (δW):
Measure the luminance of gray level 255 at 5 points
δW = Maximum [L (1), L (2), L (3), L (4), L (5)] / Minimum [L (1), L (2), L (3), L (4), L (5)]
where L (X) is corresponding to the luminance of the point X at the figure below.
LCD Module
LCD Panel
Center of the Screen
Display Color Analyzer
(Minolta CA210)
Light Shield Room
(Ambient Luminance < 2 lux)
Horizontal Line
D
D/4D/23D/4
Note (7) Definition of Transmittance (T%):
Vertical Line
Module is without signal input.
Transmittance =
W
W/4
W/2
3W /4
12
5
34
Active Area
Luminance of LCD module
Ϡ 100%
Luminance of backlight
19
: Test Point
X
X=1 to 5
Version2.0
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
8. DEFINITION OF LABELS
8.1 OPEN CELL LABEL
The barcode nameplate is pasted on each open cell as illustration for CMO internal control.
www.panelook.com
-
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
XXXXXXXXXXXX
8.2 CARTON LABEL
The barcode nameplate is pasted on each box as illustration, and its definitions are as following explanation.
P.O. NO.
Parts ID.
Model Name V315B6-P01
Carton ID.
XXXXXXXXXXXXXX
Quantities 21
(a) Model Name: V315B6– P01
(b) Carton ID: CMO internal control
(c) Quantities: 21
Made In China
20
Version2.0
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
9. PACKAGING
9.1 PACKING SPECIFICATIONS
(1) 21 LCD TV panels / 1 Box
(2) Box dimensions : 970(L)x640(W)x319(H)mm
(3) Weight : approximately 38Kg ( 21 panels per box)
9.2 PACKING METHOD
Figures 9-1 and 9-2 are the packing method
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
panel
Carton
Top la yer for empty tray
Carton Label
Figure.9-1 packing method
21
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
Sea & Land Transportation
Gross : 471kg
(L1130*50*50mm)
Film
Carton Label
(L1300*W1000*H140mm)
PE Sheet
(L1130*50*50mm)
(L1850*50*50mm)
Film
PP Belt
(L1300*W1000*H140mm)
Air Transportation
Gross : 319kg
PE Sheet
(L1130*50*50mm)
PP Belt
Carton Label
Figure.9-2 packing method
22
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
10. PRECAUTIONS
10.1 ASSEMBLY AND HANDLING PRECAUTIONS
(1) Do not apply rough force such as bending or twisting to the product during assembly.
(2) To assemble backlight or install module into user’s system can be only in clean working areas. The
dust and oil may cause electrical short or worsen the polarizer.
(3) It’s not permitted to have pressure or impulse on the module because the LCD panel will be
damaged.
(4) Always follow the correct power sequence when the product is connecting and operating. This can
prevent damage to the CMOS LSI chips during latch-up.
(5) Do not pull the I/F connector in or out while the module is operating.
(6) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is very soft and
easily scratched.
(7) It is dangerous that moisture come into or contacted the product, because moisture may damage the
product when it is operating.
(8) High temperature or humidity may reduce the performance of module. Please store this product within
the specified storage conditions.
(9) When ambient temperature is lower than 10ºC may reduce the display quality. For example, the
response time will become slowly.
10.2 SAFETY PRECAUTIONS
(1) If the liquid crystal material leaks from the panel, it should be kept away from the eyes or mouth. In
case of contact with hands, skin or clothes, it has to be washed away thoroughly with soap.
(2) After the product’s end of life, it is not harmful in case of normal operation and storage.
23
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Global LCD Panel Exchange Center
11. Mechanical Drawing
www.panelook.com
Issued Date: Feb., 13, 2009
Model No.: V315B6-P01
Approval
24
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version2.0
www.panelook.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.