Item Specification Unit Note
Active Area 575.769 (H) x 323.712 (V) (26” Diagonal) mm
Bezel Opening Area 580.8 (H) x 328.8 (V) mm
Driver Element a-si TFT Active Matrix
Pixel Number 1366 x R.G.B. x 768 pixel
Pixel Pitch (Sub Pixel) 0.1405 (H) x 0.4215 (V) mm
Pixel Arrangement RGB Vertical Stripe
Display Colors 16.2M color
Display Operation Mode Transmissive Mode / Normally White Ё
Surface Treatment
Anti-Glare Coating (Haze 25%)
Hard Coating (3H)
Ё
Ё
Ё
1.5 MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note
Horizontal(H) 625 626 627 mm
Module Size
Note (1) Please refer to the attached drawings for more information of front and back outline dimensions.
Vertical(V) 372 373 374 mm
Depth(D) 31 32 33 mm To Rear
Depth(D) 45.7 46.7 47.7 mm To Inverter Cover
Weight
Ё
4200
Ё
g
(1)
4
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 5
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item Symbol
Storage Temperature TST -20 +60 ºC (1)
Operating Ambient Temperature TOP 0 +50 ºC (1), (2)
Shock (Non-Operating) S
Vibration (Non-Operating) V
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note (2) The maximum operating temperature is based on the test condition that the surface temperature of
display area is less than or equal to 65 ºC with LCD module alone in a temperature controlled chamber.
Thermal management should be considered in final product design to prevent the surface temperature of
display area from being over 65 ºC. The range of operating temperature may degrade in case of improper
Љ 40 ºC).
NOP
NOP
Min. Max.
Ё
Ё
Value
Unit Note
50 G (3), (5)
1.0 G (4), (5)
thermal management in final product design.
Note (3) 11 ms, half sine wave, 1 time for ± X, ± Y, ± Z.
Note (4) 10 ~ 500 Hz, 10 min, 1 time each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
Relative Humidity (%RH)
100
90
80
60
Operating Range
40
20
10
Storage Range
Temperature (ºC)
5
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
8060-20400 20-40
Version 1.0
www.panelook.com
Page 6
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
2.2 ELECTRICAL ABSOLUTE RATINGS
2.2.1 TFT LCD MODULE
Item Symbol
Power Supply Voltage Vcc -0.3 13.0 V
Input Signal Voltage VIN -0.3 3.6 V
Min. Max.
2.2.2 BACKLIGHT UNIT
Item Symbol
Lamp Voltage VW
Power Supply Voltage VBL
Control Signal Level
Note (1) Permanent damage to the device may occur if maximum values are exceeded. Functional
operation should be restricted to the conditions described under normal operating conditions.
Note (2) No moisture condensation or freezing.
Condition
Ta = 25
Ё Ё
Value
Te st
кЁ Ё
Ё
Unit Note
(1)
Min.TypeMax.UnitNote
0
-0.3
Ё
Ё
3000V
30 V
7 V
RMS
(1)
(1), (3)
Note (3) The control signals includes Backlight On/Off Control, Internal PWM Control and External PWM
Control.
6
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 7
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD MODULE
Parameter Symbol
Power Supply Voltage VCC 11.4 12.0 12.6 V (1)
Power Supply Ripple Voltage VRP
Rush Current I
White
Power Supply Current
Differential Input High
LVDS
Interface
Threshold Voltage
Differential Input Low
Threshold Voltage
Common Input Voltage V
Terminating Resistor R
CMOS
interface
Input High Threshold Voltage VIH 2.7
Input Low Threshold Voltage V
Note (1) The module should be always operated within above ranges.
Black
Vertical Stripe
Ta = 25 ± 2 ºC
Value
Min. Typ. Max.
Ё Ё
RUSH
ICC
V
LVT H
-100
V
LVTL
1.125 1.25 1.375 V
LVC
T
Ё Ё
Ё
Ё
Ё
0.2
0.5
0.4
Ё Ё
Ё Ё
Ё
100
Ё
0
IL
Ё
300 mV
3.0 A (2)
Ё
Ё
Ё
+100 mV
Ё
3.3 V
0.7 V
Unit Note
A
A
A
mV
ohm
(3)
Note (2) Measurement Conditions:
+12.0V
R1
200K
(Low to High)
(Control Signal)
SW
R2
1K
Vcc rising time is 470us
Q1 AO4409
2N7002
Q2
47K
VR1
C1
10uF
+12V
FUSE
C3
1uF
Vcc
(LCD Module Input)
0.9Vcc
0.1Vcc
GND
470us
7
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 8
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
Note (3) The specified power supply current is under the conditions at Vcc = 12 V, Ta = 25 ± 2 ºC, fv = 60
Hz, whereas a power dissipation check pattern below is displayed.
9SELLVDS Select LVDS data format
10NC No connection
11GND Ground
12RX0- Negative transmission data of pixel 0
13RX0+ Positive transmission data of pixel 0
14GND Ground
15RX1- Negative transmission data of pixel 1
16RX1+ Positive transmission data of pixel 1
17GND Ground
18RX2- Negative transmission data of pixel 2
19RX2+ Positive transmission data of pixel 2
20GND Ground
21RXCLK- Negative of cloc
22RXCLK+ Positive of cloc
23GND Ground
24RX3- Negative transmission data of pixel 3
25RX3+ Positive transmission data of pixel 3
26GND Ground
27NC No connection
28NC No connection
29GND Ground
30GND Ground
Note (1) Connector Part No.: P-TWO,196108-30041 or compatible
mbolDescriptionNote
Preliminary
Note (2) Ground or OPEN: Normal, High: JEIDA LVDS format
Please refer to 5.5 LVDS INTERFACE (Page 17)
Note (3) Reserved for internal use. Please leave it open.
13
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 14
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
5.2 BACKLIGHT UNIT
The pin configuration for the housing and leader wire is shown in the table below.
CN2-CN6 (Housing) : CP0404S000(CviLux) or equivalent.
Pin No. Symbol Description
1 HV High Voltage Pink
2 HV High Voltage White
Note (1) The backlight interface housing for high voltage side is a model CP0404S000 (CviLux) or equivalent.
The mating header on inverter part number is CP042CP1MRO-LF (CyiLux) or equivalent.
Wire Color
5 Male Connectors
CP0404S000(CviLux)
or Equivalent
1.HV(Pink,+)
2.HV(White,-)
1.HV(Pink,+)
2.HV(White,-)
1.HV(Pink,+)
2.HV(White,-)
1.HV(Pink,+)
2.HV(White,-)
1.HV(Pink,+)
2.HV(White,-)
14
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 15
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
5.3 INVERTER UNIT
CN1 (Header) : 1.S14B-PH-SM4-TB (JST) 2.CI0114M1HRO-LF(Cvilux) or equivalent.
Pin No. Symbol Description
1
2
3
4
5
6
7
8
9
10
11 ERR
12 BLON BL ON/OFF
13 I_PWM Internal PWM Control
14 E_PWM External PWM Control
Notice:
#PIN 13:Analog Dimming Control (Use Pin 13) : 0V~3.3V and Pin 14 must open.
VBL +24V Power input
GND Ground
Normal (GND)
Abnormal(Open collector)
Preliminary
#PIN 14:PWM Dimming Control (Use Pin 14) : Pin 13 must open.
#Pin 13 (I_PWM) and Pin 14 (E_PWM) can not open in same period.
CN2-CN6 (Header) : CP042CP1MRO-LF(Cvilux) or equivalent.
Pin Name Description
1
2
CCFL HOT
CCFL HOT
CCFL High Voltage
CCFL High Voltage
15
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 16
Global LCD Panel Exchange Center
p
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
5.4 BLOCK DIAGRAM OF INTERFACE
R0-R7
-
B0-B7
DE
Host
Graphics
Controller
LVDS Transmitter
THC63LVDM83A
(LVDF83A)
CNF1
Rx0+
-
Rx1+
Rx1-
Rx2+
Rx2-
Rx3+
Rx3-
CLK+
CLK-
51
Ө
100pF
51
Ө
51
Ө
51
51
51
51
51
51
51
100
Ө
Ө
100pF
Ө
Ө
100pF
Ө
Ө
100pF
Ө
LVDS Receiver
THC63LVDF84A
Preliminary
RxOUT
R0-R7
G0-G7
F
B0-B7
DE
DCLK
Timing
Controller
R0~R7 : Pixel R Data
G0~G7 : Pixel G Data
B0~B7 : Pixel B Data
DE : Data Enable Signal
Note (1) The system must have the transmitter to drive the module.
Note (2) LVDS cable impedance shall be 50 ohms per signal line or about 100 ohms per twist-pair line when it is
used differentially.
16
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 17
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
5.5 LVDS INTERFACE
SIGNAL
SELLVD=
L or OPEN
R0
R1
R2
R3
R4
R5
G0
G1
G2
G3
G4
G5
B0
B1
24
bit
B2
B3
B4
B5
DE
R6
R7
G6
G7
B6
B7
RSVD 1
RSVD 2
RSVD 3
DCLK 31 TxCLK IN TxCLK OUT+
R0~R7: Pixel R Data (7; MSB, 0; LSB)
SELLVDS
=H
R2
R3
R4
R5
R6
R7
G2
G3
G4
G5
G6
G7
B2
B3
B4
B5
B6
B7
DE
R0
R1
G0
G1
B0
B1
RSVD 1
RSVD 2
RSVD 3
TRANSMITTER
THC63LVDM83A
PIN INPUT Host TFT-LCDPINOUTPUT
51
52
54
55
56
3
4
6
7
11
12
14
15
19
20
22
23
24
30
50
2
8
10
16
18
25
27
28
TxIN0
TxIN1
TxIN2
TxIN3
TxIN4
TxIN6
TxIN7
TxIN8
TxIN9
TxIN12
TxIN13
TxIN14
TxIN15
TxIN18
TxIN19
TxIN20
TxIN21
TxIN22
TxIN26
TxIN27
TxIN5
TxIN10
TxIN11
TxIN16
TxIN17
TxIN23
TxIN24
TxIN25
INTERFACE
CONNECTOR
TA OUT0+
TA OUT0-
TA OUT1+
TA OUT1-
TA OUT2+
TA OUT2-
TA OUT3+
TA OUT3-
TxCLK OUT-
Rx 0+
Rx 0-
Rx 1+
Rx 1-
Rx 2+
Rx 2-
Rx 3+
Rx 3-
RxCLK IN+
RxCLK IN-
RECEIVER
THC63LVDF84A
Rx OUT0
27
Rx OUT1
29
Rx OUT2
30
Rx OUT3
32
Rx OUT4
33
Rx OUT6
35
Rx OUT7
37
Rx OUT8
38
Rx OUT9
39
Rx OUT12
43
Rx OUT13
45
Rx OUT14
46
Rx OUT15
47
Rx OUT18
51
Rx OUT19
53
Rx OUT20
54
Rx OUT21
55
Rx OUT22
1
Rx OUT26
6
Rx OUT27
7
Rx OUT5
34
Rx OUT10
41
Rx OUT11
42
Rx OUT16
49
Rx OUT17
50
Rx OUT23
2
Rx OUT24
3
Rx OUT25
5
26 RxCLK OUTDCLK
Preliminary
TFT CONTROL
INPUT
SELLVD=
L or OPEN
R0
R1
R2
R3
R4
R5
G0
G1
G2
G3
G4
G5
B0
B1
B2
B3
B4
B5
DE
R6
R7
G6
G7
B6
B7
NC
NC
NC
SELLVDS
=H
R2
R3
R4
R5
R6
R7
G2
G3
G4
G5
G6
G7
B2
B3
B4
B5
B6
B7
DE
R0
R1
G0
G1
B0
B1
NC
NC
NC
G0~G7: Pixel G Data (7; MSB, 0; LSB)
B0~B7: Pixel B Data (7; MSB, 0; LSB)
DE : Data enable signal
Notes(1) RSVD(reserved)pins on the transmitter shall be “H” or “L”.
17
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 18
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
5.6 COLOR DATA INPUT ASSIGNMENT
The brightness of each primary color (red, green and blue) is based on the 8-bit gray scale data input for
the color. The higher the binary input, the brighter the color. The table below provides the assignment of
Note (1) 0: Low Level Voltage, 1: High Level Voltage
Blue
Cyan
Magenta
Yellow
White
Red(0) / Dark
Red(1)
Red(2)
:
:
Red(253)
Red(254)
Red(255)
Green(0) / Dark
Green(1)
Green(2)
:
:
Green(253)
Green(254)
Green(255)
Blue(0) / Dark
Blue(1)
Blue(2)
:
:
Blue(253)
Blue(254)
Blue(255)
0
1
1
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
:
:
:
:
1
1
1
1
1
1
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
Red Green Blue
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
0
0
0
0
0
1
0
1
1
1
1
0
0
0
0
0
1
1
1
1
1
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
1
1
1
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
:
:
1
1
1
1
1
1
0
0
0
0
0
0
:
:
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0
0
0
0
1
0
:
:
:
:
0
1
1
1
1
1
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0
0
0
1
0
1
0
1
1
1
0
0
1
1
1
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0
0
0
1
0
0
:
:
:
:
0
1
0
0
0
1
0
0
0
0
0
0
:
:
:
:
1
0
1
0
1
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
1
1
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
1
1
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
0
0
0
1
1
1
0
0
0
0
0
0
0
0
0
:
:
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
0
:
:
:
:
:
:
1
0
1
0
1
1
1
1
1
18
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 19
Global LCD Panel Exchange Center
g
y
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
6. INTERFACE TIMING
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
The input signal timing specifications are shown as the following table and timing diagram.
nalItemSymbolMin.Typ.Max.UnitNote
Si
Frequenc
LVDS Receiver Clock
LVDS Receiver Data
Vertical Active Display Term
Horizontal Active Display Term
Note (1) Since this module is operated in DE only mode, Hsync and Vsync input signals should be set to
Input cycle to
cycle jitter
Setup Time Tlvsu 600
Hold Time Tlvhd 600
Frame Rate
Total Tv
Display Tvd
Blank Tvb 1038 120 Th Tota l T h
Display Thd
Blank Thb 76194 570 Tc -
1/Tc607682MH
Trcl
Fr
5
Fr
6
Ё
475053Hz
576063Hz
778
768
1442
1366
Ё
Ё Ё
Ё Ё
806 888 Th Tv=Tvd+Tvb
768 768 Th -
1560 1936 Tc Th=Thd+Thb
1366 1366 Tc -
200 ps
ps
ps
Z
low logic level. Otherwise, this module would operate abnormally.
INPUT SIGNAL TIMING DIAGRAM
DE
DCLK
DE
T
h
Tvd
Tv
Tvb
Thd
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
DATA
Valid Display Data (1366clocks)
19
Version 1.0
www.panelook.com
Page 20
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
RXCLK+/-
RXn+/-
Tlvsu
Tlvhd
1T
14
LVDS RECEIVER INTERFACE TIMING DIAGRAM
Tc
3T
14
5T
14
7T
14
9T
14
11T
14
13T
14
Preliminary
20
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 21
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
6.2 POWER ON/OFF SEQUENCE
To prevent a latch-up or DC operation of LCD module, the power on/off sequence should be as the
diagram below.
CC
Power Supply
V
0.5ЉT
0
0
1s
CC
1
Љ
10 ms
Љ
T
2
Љ
50 ms
Љ
T
3
Љ
50 ms
Љ
T4
Signals
0.9 V
CC
0V
0.1V
CC
3
T1
T
2
T
VALI D
0V
Power On
Power Off
0.9 V
0.1Vcc
T4
Backlight (Recommended)
Љ
500 ms
100 msЉT
T5
6
50%
5
T
50%
T
6
Power ON/OFF Sequence
Note (1) The supply voltage of the external system for the module input should follow the definition of Vcc.
Note (2) Apply the lamp voltage within the LCD operation range. When the backlight turns on before the LCD
operation or the LCD turns off before the backlight turns off, the display may momentarily become
abnormal screen.
Note (3) In case of Vcc is in off level, please keep the level of input signals on the low or high impedance.
Note (4) T4 should be measured after the module has been fully discharged between power off and on period.
Note (5) Interface signal shall not be kept at high impedance when the power is on.
21
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 22
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
7. OPTICAL CHARACTERISTICS
7.1 TEST CONDITIONS
Item Symbol Value Unit
Ambient Temperature Ta
Ambient Humidity Ha
Supply Voltage VCC 12.0 V
Input Signal According to typical value in "3. ELECTRICAL CHARACTERISTICS"
Lamp Current IL
Oscillating Frequency (Inverter)FW
Vertical Frame Rate
Fr 60 Hz
25±2
50±10
7.5 ± 0.5
66 ± 3
7.2 OPTICAL SPECIFICATIONS
The relative measurement methods of optical characteristics are shown in 7.2. The following items should be
measured under the test conditions described in 7.1 and stable environment shown in Note (6).
Item SymbolCondition Min. Typ. Max. UnitNote
Contrast Ratio CR (600) (800) - (2)
Response Time
Center Luminance of WhiteL
White Variation
Cross Talk CT (4) % (5)
Red
Green
Color
Chromaticity
Blue
TR
TF
C
δW
=0°, θY =0°
θ
Rx (0.639)-
Ry (0.330)-
Gx (0.275)-
Gy (0.593)-
Bx (0.151)-
By
x
Viewing Angle at
Normal Direction
(3) (5)
(5) (8)
(400) (500) (4)
(1.3) - (7)
Typ.
-0.03
(0.064)
Typ.
+0.03
o
C
%RH
mA
KHz
ms(3)
(6)
-
Viewing
Angle
White
Color GamutCG
Horizontal
Vertical
Wx (0.280)-
Wy
θx+
θ
x
θY+
θ
Y
(0.285)
(68) (72) %
(70) (80)
-
-
CR≥10
22
(70) (80)
(70) (80)
(60) (70)
-
NTSC
Ratio
Deg.(1)
Version 1.0
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Page 23
Global LCD Panel Exchange Center
T
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Note (1) Definition of Viewing Angle (θx, θy):
Viewing angles are measured by EZ-Contrast 160R (Eldim)
θX- = 90º
x-
6 o’clock
θ
y-
= 90º
y-
Normal
θx = θy = 0º
θy-θy+
θx−
θx+
y+
12 o’clock direction
θ
y+
= 90º
x+
θX+ = 90º
Preliminary
Note (2) Definition of Contrast Ratio (CR):
The contrast ratio can be calculated by the following expression.
Contrast Ratio (CR) = L255 / L0
L255: Luminance of gray level 255
L 0: Luminance of gray level 0
CR = CR (5),
CR (X) is corresponding to the Contrast Ratio of the point X at the figure in Note (7).
Note (3) Definition of Response Time (T
Gray Level 255
100%
90%
Optical
Response
10%
0%
R
TR
, TF):
Gray Level 0
T
Gray Level 255
F
ime
23
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 24
Global LCD Panel Exchange Center
(
)
(
)
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Note (4) Definition of Luminance of White (L
Measure the luminance of gray level 255 at center point and 5 points
LC = L (5)
L (X) is corresponding to the luminance of the point X at the figure in Note (7).
Note (5) Definition of Cross Talk (CT):
CT = | Y
– YA | / YA × 100 (%)
B
Where:
Y
= Luminance of measured location without gray level 0 pattern (cd/m2)
A
= Luminance of measured location with gray level 0 pattern (cd/m2)
Y
B
(0, 0)
Active Area
Y
(D/8,W/2)
A, L
Gray 128
Y
(D/2,7W/8)
A, D
Y
Y
D,W
A, U
A, R
):
C
(D/2,W /8)
(7D/8,W/2)
(D/4,W/4)
(D/8,W/2)
Y
B, L
Y
(D/2,7W/8)
B, D
0, 0
Active Area
Gray 0
Gray 128
Preliminary
Y
(D/2,W /8)
B, U
Y
(7D/8,W/2)
B, R
(3D/4,3W/4)
(D,W)
Note (6) Measurement Setup:
The LCD module should be stabilized at given temperature for 1 hour to avoid abrupt temperature
change during measuring. In order to stabilize the luminance, the measurement should be
executed after lighting Backlight for 1 hour in a windless room.
LCD Module
LCD Panel
Center of the Screen
Display Color Analyzer
(Minolta CA210)
Light Shield Room
(Ambient Luminance < 2 lux)
24
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 25
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Note (7) Definition of White Variation (δW):
Measure the luminance of gray level 255 at 5 points
δW = Maximum [L (1), L (2), L (3), L (4), L (5)] / Minimum [L (1), L (2), L (3), L (4), L (5)]
W
W/4
W/2
3W /4
Vertical Line
Horizontal Line
D
D/4D/23D/4
12
: Test Point
5
34
X
X=1 to 5
Preliminary
Active Area
25
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 26
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
8. DEFINITION OF LABELS
8.1 CMO MODULE LABEL
The barcode nameplate is pasted on each module as illustration, and its definitions are as following explanation.
E207943
CHIMEI
OPTOELECTRONICS
(a) Model Name: V260B1-L11
(b) Revision: Rev. XX, for example: A0, A1… B1, B2… or C1, C2…etc.
(c) Serial ID: X X
X X
V260B1 -L11 Rev. XX
X X X X X X X Y M D L N N N N
X
X X
Y M D
L
N N N N
Serial No.
Product Line
MADE IN TAIWAN
RoHS
Serial ID includes the information as below:
(a) Manufactured Date: Year: 1~9, for 2001~2009
Month: 1~9, A~C, for Jan. ~ Dec.
Day: 1~9, A~Y, for 1
(b) Revision Code: Cover all the change
(c) Serial No.: Manufacturing sequence of product
(d) Product Line: 1 -> Line1, 2 -> Line 2, …etc.
Year, Month, Date
CMO Internal Use
CMO Internal Use
Revision
CMO Internal Use
st
to 31st, exclude I ,O, and U.
26
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 27
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
9. PACKAGING
9.1 PACKING SPECIFICATIONS
(1) 6 LCD TV Modules / Carton
(2) Carton Dimensions : 713(L) X 429 (W) X 453 (H)
(3) Weight : Approximately 29 Kg ( 6 Modules Per Carton)
9.2 PACKING METHOD
Figures 9-1 and 9-2 are the packing method
LCD TV Module
Preliminary
Carton
Anti-Static Bag
Cushion(Bottom)
2 pcs Drier
Carton Label
Figure.9-1 packing method
27
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 28
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Sea / Land Transportation (40ft HQ Container)
Preliminary
Sea / Land Transportation (40ft Container)
PE Sheet
28
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 29
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Corner Protector
Air Transportation
Preliminary
Figure. 9-2 packing method
29
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 30
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
10. PRECAUTIONS
10.1 ASSEMBLY AND HANDLING PRECAUTIONS
(1) Do not apply rough force such as bending or twisting to the module during assembly.
(2) It is recommended to assemble or to install a module into the user’s system in clean working areas.
The dust and oil may cause electrical short or worsen the polarizer.
(3) Do not apply pressure or impulse to the module to prevent the damage of LCD panel and backlight.
(4) Always follow the correct power-on sequence when the LCD module is turned on. This can prevent the
damage and latch-up of the CMOS LSI chips.
(5) Do not plug in or pull out the I/F connector while the module is in operation.
(6) Do not disassemble the module.
(7) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is very soft and
easily scratched.
(8) Moisture can easily penetrate into LCD module and may cause the damage during operation.
(9) High temperature or humidity may deteriorate the performance of LCD module. Please store LCD
modules in the specified storage conditions.
(10) When ambient temperature is lower than 10ºC, the display quality might be reduced. For example, the
response time will become slow, and the starting voltage of CCFL will be higher than that of room
temperature.
10.2 SAFETY PRECAUTIONS
(1) The startup voltage of a backlight is over 1000 Volts. It may cause an electrical shock while assembling
with the inverter. Do not disassemble the module or insert anything into the backlight unit.
(2) If the liquid crystal material leaks from the panel, it should be kept away from the eyes or mouth. In
case of contact with hands, skin or clothes, it has to be washed away thoroughly with soap.
(3) After the module’s end of life, it is not harmful in case of normal operation and storage.
10.3 STORAGE PRECAUTIONS
When storing modules as spares for a long time, the following precaution is necessary.
(1) Do not leave the module in high temperature, and high humidity for a long time.
It is highly recommended to store the module with temperature from 0 to 35
condensation.
(2) The module shall be stored in dark place. Do not store the TFT-LCD module in direct sunlight or fluorescent
кat normal humidity without
light.
30
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 31
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
11. MECHANICAL CHARACTERISTICS
Preliminary
ڻႝηިҽԖϦљڻႝηިҽԖϦљ
CHI MEICH I MEI
31
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 32
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
ڻႝηިҽԖϦљڻႝηިҽԖϦљ
CHI MEICHI MEI
COLD CATHODE FLUORESCENT LAMP IN LCD PANEL CONTAINS A SMALL AMOUNT OF
MERCURY PLEASE FOLLOW L OCAL ORDINANCES OR REGULATIONS FOR DISPOSAL.
CAUTION
HIGH VOLTAGE
RISK OF ELE CTRIC SHOCK.
DISCONNECT THE ELECTRIC
POWER BEFORE SERVIC ING.
32
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 33
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
ڻႝηިҽԖϦљ
ڻႝηިҽԖϦљ
No.
CHI MEI
CHI MEI
33
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Page 34
Global LCD Panel Exchange Center
www.panelook.com
Issued Date: 15, Jan 2008
Model No.: V260B1 – L11
Preliminary
ڻႝηިҽԖϦљڻႝηިҽԖϦљ
CHI MEICHI MEI
34
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Version 1.0
www.panelook.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.