Cleveland KGL-25-T Service Manual

Page 1
Statement of Responsibilities
This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and equipment they service.
Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage resulting from use of, improper use of, or failure to use the information contained in this document.
Cleveland Range, LLC has made every effort to provide accurate information in this document, but cannot guarantee that this document does not contain unintentional errors and omissions.
The information in this document may be subject to technical and technological changes, revisions, or updates.
Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or updates.
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out / tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas, electric, and steam powered equipment and / or appliances
All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of operation according to OSHA approved practices during any servicing of Cleveland Ran ge equipment
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date knowledge, skills, materials and equipment.
Page 2
Cleveland Range, LLC
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110
Ph: 1-216-481-4900 Fx: 1-216-481-3782 Visit our Web Site at www.clevelandrange.com
Page 3
CLEVELAND RANGE KGL-25
SEQUENCE OF OPERATIONS
1. To turn the unit on, turn the switch to the on position.
Power is sent to primary side of the 120vac/16vac transformer.
Power is sent to the normally closed high limit.
From the high limit power is sent to the normally open contacts of the 12VDC relay.
2.
From the secondary of the transformer 16VAC is sent to the controller
Power is sent to the red LED (low water indicator light) from terminal 4 of the
controller.
If the water probe is grounded through water the LED will go off.
If the water probe is not grounded the LED will remain on and the unit will not
heat.
If the resistance of the thermistor is higher than the setting of the potentiometer( the
unit is calling for heat) then 16VDC is sent to the coil of the relay and the green LED (heat indicator light)
The 12VDC relay will close until the unit reaches temperature
3. With the contacts of the relay closed, power is sent to the 24 VAC transformer.
The transformer sends 24 VAC to the ignition module.
Ignition module sends 24 VAC to the Amber LED
The ignition module will send spark to the igniter and 24 VAC to the gas valve.
With 24VAC to the gas valve the valve opens and gas is sent to the burner.
Spark and gas together cause ignition.
When this happens and the module reads at least 0.7 micro amps DC within 4
seconds, the Amber light will go out and the 24 VAC will remain on the gas valve.
The unit will heat causing the water to boil and steam to be generated.
If the module does not see the 0.7 micro-amps in 4 seconds, the module will try
again in 15 seconds. It will try 3 times then lock out.
4. The kettle will heat (build pressure) until the controller is satisfied by the thermistor at the
setting of the potentiometer.
The controller will then turn off the heat circuit until the temperature of the kettle is
below the setting.
When the temperature drops below the setting the controller will send 12 VDC to the
relay and the heat circuit will be energized again.
5. To turn the unit off, place the switch in the off position.
Power will be removed from the controller and the heat circuit will de-energize.
.
Page 4
Replace
the on/off
switch (toggle
or rotary).
Replace the transformer.
PROBLEM:
KGT
KGL-25
Kettle Won't
Heat
Is 16 VAC at the
secondary side of
Yes
the transformer?
Is there 115 VAC
Yes
to the primary of
the transformer?
Supply115 VAC to the
No
No
kettle.
Does red light
come on when unit
is first turned on?
Is 16 VAC
measured acros s
No
Pins 9 and 10 on
the controller?
Replace the
Replace the
high limit.
Replace the
transformer
No
relay.
ignition
Does red light g o
Yes
off shortly after unit
is turned on?
potentiometer set
at 10, is 12 VDC at
Yes
No
No
the coil of t he
Does the relay pull
Is there 115 VAC
to the primary of
No
transformer?
Is there 24 VAC t o
Yes
With the
relay?
Yes
in?
Yes
the ignition
Yes
the ignition
Module?
Add water to
No
jacket of Kett l e.
With a jumper
across pins 5 and
7 on the controller,
No
is there 12 VDC
across the coil of
the DC relay?
Does the
potent iomer h ave
a resistance of
50,000 ohms on
low and 0 ohms at
Does the probe
have a resist ance
of 100,000 ohms +
10% at room
temperature?
Replace Probe
Yes
high?
Yes
No
removed and the
No
probe, is 12 VDC measured acros s the coil of t he D C
No
Yes
Replace the
wire harness in
the trunion
No
With the jumper
probe wi r e
grounded at the
relay?
Yes
Add water
Replace the
potentiometer
Replace the
controller
No
Replace
the Ignition
module.
No
Yes
Is there 24 VAC t o
the Gas valve for 4
Seconds?
Yes
Is there Gas to the
burner?
Yes
Is there Spark t o
the ignitor for 4
seconds.
Yes
If there
is spark and gas t o
the burner assmbly
there shoul d b e
flame. Check
alighnment.
No
Replace the
gas valve
Page 5
PROBLEM:
KGT
KGL-25
Kettle Not
Hot Enough
Does the kettle
heat at all ?
Yes
With kettle pot
empty a nd
temperature knob
set at 10, is the
temperature of t h e
surface of the p ot
260 degrees?
No
Yes
See Problem:
kettle won't heat .
Unit is
operating
properly
Yes
Vent the kettle per instructions in
the manual.
When unit is cold
(room temp) is t h e
No
pressure gauge in
the green ?
When the unit is
calling for heat (t h e
green light is on),
is there flame at
the burner?
Is the resistance of
the thermister
100,000 ohms
+10% at room
temperature?
No
Yes
Yes
Is there 24 VAC t o
Is there 115 VAC
No
No
to the primary of
Replace the
igniton
transformer
No
the ignition
module?
Yes
the ignition
module?
Replace the
thermister.
No
Replace the
high limit
Replace
controller.
Yes
ohms at low and 0
Yes
Is the
potentiometer
resistance 50,000
ohms at high?
No
Replace the
potentiometer.
Page 6
PROBLEM:
KGT
KGL-25
Kettle Gets
Too Hot
The
kettle is workin g
properly.
temperature s et at
Yes
continue to call f or
260-265 degrees?
With the kettle empty and the
10, is the surface
temp 260-265
degrees?
No
Does the kettle
heat (green light
stays on) when
the kettle reaches
No
Is the resistance of
Yes
;the thermister
100,000 ohms +
10% at room
temperature?
Yes
No
Replace the
thermister.
Replace the
gas valve.
Replace the
Relay
Is there 115 vac to
No
No
the primary of th e
ignition
transformer?
Yes
Is there DC
voltage to the coi l
of the relay?
Yes
Replace the
controller
Is the resistance of the thermister the s ame as
the previous step wh en
measured between p i n
2 at the controller and
ground?
Calibrate or
replace the
controller
PROBLEM: Red Add Water LED Stays On
Yes
No
Replace the
wire harness
Add the proper
amount of distilled
water and rust
inhibitor.
Clean or
replace water
probe.
Replace the
wire harness in
the trunion.
Does Red LED st ay on after adding the prop er
No
No
No
amount of distilled
water and rust inhibitor?
Is the red LED on
with probe grounded?
Does the r ed L E D
stay on with a
jumper between
pins 5 and 7 on t h e
controller?
Yes
Yes
Yes
Replace the
controller.