Cleveland KGL-100-T, KGL Service Manual

INSTALLATION, OPERATION AND REPAIR MANUAL
9102 REV:0
222-01CO
GAS KETTLE
MODEL # KGL KGL-T
CLEVELAND RANGE INC. 1333 East 179th St. Cleveland, Ohio U.S.A. 44110
(216)481-4900
KET-07
IMPORTANT
THE FOLLOWING POINTS ARE TO INSURE THE SAFE INSTALLATION AND OPERATION OF THIS EQUIPMENT :
INSURE ALL GAS AND ELECTRICAL SUPPLIES MATCH RATING PLATE AND ELECTRICAL STICKERS
OBSERVE ALL CLEARANCE REQUIREMENTS DISCONNECT THE ELECTRICAL POWER SUPPLY TO THE APPLIANCE BEFORE
CLEANING OR SERVICING UNIT
ONLY A QUALIFIED SERVICE TECHNICIAN SHOULD REPAIR UNIT
THE INSTALLATION AND CONNECTION MUST COMPLY WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH CAN1 B149 INSTALLATION CODE OR WITH THE NATIONAL FUEL GAS CODE, ANSI 2223.1-1988.
POST IN A PROMINENT LOCATION, INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLER.
THE APPLIANCE AND ITS INDIVIDUAL SHUT OFF VALVE M UST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF 1/2 PSIG. (3.45 KPA).
THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING ITS INDIVIDUAL MANUAL SHUT OFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (3.45 KPA).
RETAIN THIS MANUAL FOR YOUR REFERENCE.
1
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS AND VAPOURS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
- -IF YOU SMELL GAS - -
OPEN WINDOWS DO NOT TOUCH
ELECTRICAL SWITCHES.
3. EXTINGUISH ANY OPEN FLAME.
4. CALL YOUR GAS SUP PLIER IMMEDIATELY.
GENERAL INSTALLATION INSTRUCTIONS
Installation of kettle must be accomplished by qualified installation personnel, working to all applicable local and national codes. Improper installation of product could cause injury or damage.
This equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, A.G.A, NSF. ASME/N.Bg, CSA, CGA, ETL, and others. Many local codes exist, and it is the responsibility of the owner and installer to comply with these codes.
Observe all clearance requirements to provide proper make-up air flow as well as sufficient clearance for servicing. Dimensions and clearance specifications are shown on the specification sheet. Do not install kickplates or otherwise obstruct the flow of combustion and ventilation air. Check the rating plate to ensure that the kettle has been equipped to operate with the type of gas available at the installation.
Gas fired kettles are only to be installed under a ventilation hood in a room which has provisions for adequate make up air.
Electrical installation must be in accordance with local codes and/or the National Electric Code ANSI/NFPA 70-1987 (USA) or the Canadian Electrical Code CSA Standard C22.1 (Canada). The kettle must be electrically grounded by the installer. Standard supply voltage is 115 volts A.C. However, optional A.C. voltages can be supplied on special order. A separate fused disconnect switch must be supplied and installed in the high voltage electrical supply line. The wire gauge size and electric supply must match the power requirements specified on the kettle's rating plate. The conduit-enclosed permanent copper wiring must be adequate to carry the required current at the rated voltage. Refer to the specification sheet for electrical specifications and location of electrical connections.
INSPECTION
Before unpacking visually inspect the unit for evidence of damage during shipping. If damage is noticed, do not unpack the unit, follow shipping damage instructions.
SHIPPING DAMAGE INSTRUCTIONS
If shipping damage to the unit is discovered or suspected, observe the following guidelines in preparing a shipping damage claim.
1. Write down a description of the damage or the reason for suspecting damage as soon as it is discovered. This will help in filling out the claim forms later.
2. As soon as damage is discovered or suspected, notify the carrier that delivered the shipment.
2
3. Arrange for the carrier's representative to examine the damage.
4. Fill out all carrier claims forms and have the examining carrier sign and date each form.
INSTALLATION
The first installation step is to refer to the specification sheet for clearance requirements, in order to determine the location of the kettle. Next, carefully cut open the shipping carton for easy removal of the kettle.
Position the kettle in its permanent location, and level the kettle by tuning the adjustable feet.
Once positioned and leveled, permanently secure the kettle's flanged feet to the floor using 5/16 x 2 1/2 inch lag bolts and floor anchors (supplied by the installer). Three bolts per leg are required to secure each of the flanged feet.
pipe joint compound which is resistant to L.P. gas. Test all pipe joints for leaks with soap and water solution. Ensure that the gas pressure regulator is set for the manifold pressure indicated on the gas rating plate.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shut­off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).
ELECTRICITY Remove the two screws securing the
console cover, and remove the cover. A wiring diagram is affixed to the inside of the cover. Feed conduit-enclosed permanent copper wiring through the cutout in the bottom of the console and fasten to the terminal block. Fasten the ground wire to the ground lug, connected to the frame, beside the terminal block. Replace the console cover and secure it with the screws.
GAS It is recommended that a sediment trap
(drip leg) be installed in the gas supply line. If the gas pressure exceeds 14" water column, a pressure regulator must be installed, to provide a maximum of 14" water column gas pressure to the gas control valve.
Connect the gas supply piping to the input side of the gas control valve. Location and pressure data are shown on the specification sheet. Installation must be in accordance with local codes and/or the National Fuel Gas Code ANSI Z223.1-1984 (USA) or Installation Codes for Gas Burning Appliances and Equipment CANI B149.1 and B149.2 (Canada). Use a gas
WATER The sealed jacket of the gas-fired kettle is
precharged with the correct amount of a water-based formula, and therefore, no water connection is required to the kettle jacket.
3
OPERATION
1. Before turning the kettle on, read the vacuum/pressure gauge. The gauge's needle should be in the green zone. If the needle is in the "vent air" zone, call your service agent to locate and repair the source of the leak. Under normal circumstances the kettle should operate for years without venting.
2. Ensure that the electrical service to the kettle is turned on.
3. Place the kettle's power on/off switch to the "ON" position.
4. Pre-heat the kettle by turning the temperature control knob to the desired temperature setting. The green light will remain lit (indicating the gas burners are ignited) until the temperature setting is reached. When the green light goes off, the burners are off, and pre-heating is complete.
NOTE: When cooking egg and milk products, the kettle should not be preheated, as products of this nature adhere to hot cooking surfaces. These types of food should be placed in the kettle before heating is begun.
and the gas burners have been automatically shut off by the kettle's safety circuit. Water must be added to the reservoir before further use. Refer to the "Reservoir Fill Procedures" for details.
7. When cooking is completed, turn knob to minimum and place the power on/off switch to the "OFF" position.
8. Pour the contents of the kettle into an appropriate container by opening the draw-off valve. Care should be taken to pour slowly enough to avoid splashing of the product.
NOTE: As with cleaning food soil from any cookware, an important part of kettle cleaning is to prevent foods from drying on. For this reason, cleaning should be completed immediately after cooked foods are removed. Refer to the "Care and Cleaning Instructions" for detailed kettle washing procedures.
CARE AND CLEANING Your Cleveland kettle must be cleaned
regularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, reliable operations.
5. Place product into the kettle.
6. Turn the temperature control knob to the required temperature setting. The green light will cycle on and off with the solid state control, indicating the burners are cycling on and off to maintain the set temperature.
NOTE: The red "low water" light should not be lit during kettle operation. This light indicates that the water level has reached a critically low level,
1. Prepare a warm water and mild detergent solution in the kettle.
2. Remove food deposits inside the kettle using a nylon brush. Do not use a metal bristle brush, as this may permanently damage the kettle's stainless steel surface.
3. Loosen food which is stuck to the kettle by allowing it to soak at a low temperature setting.
4