Cleveland
™
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
CSI Section ____________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
COOK CHILL SYSTEMS
COOK/CHILL CONTROL CENTERS
Dual Remote Mounted Controls for
Horizontal or Inclined Mixer Kettles
Cleveland Standard Features
I Floor or wall mounting models (please specify)
I Independant controls for each mixer kettle
I Variable mixer speed control
I Mixer start/stop button
I Solid state temperature controls with digital read-out
I Two (2) time/temperature chart recorders to provide
permanent record of Batch Processing
I Controls for automatic and manual steam
I Controls for automatic and manual water cooling
I Simmer controls for delicate products
I Two (2) automatic water meters with accumulative “add on”
button and digital readout (for cold water only)
I All stainless steel construction
I Type 4X rating
I U.L. Listed
I Accepted for use in U.S.D.A. Inspected Facilities
Cook/Chill Systems
ODELS: HA-DE-CC HA-DE-CC/W (Wall Mount)
M
IA-DE-CC IA-DE-CC/W (Wall Mount)
Options & Accessories
Ë Lockable cover over controls
Ë
Dual water meter for hot and cold kettle fill
Ë Computer interface connections
Model HA-DE-CC shown
Short Form Specifications
Shall be Cleveland Model _____-DE-CC___ , COOK/CHILL CONTROL CENTER with individual controls for each mixer kettle;
Solid State Temperature Controls with digital read-out;
Time/Temperature Chart Recorders; Automatic and Manual
Water Cooling; Simmer Controls; Automatic Water Meters with
accumulative “add on” button and digital readout; Variable Mixer
Speed Control and Mixer Start/Stop Button.
SECT. XIV PAGE 17
0609
40"
15"
69"
18 3/4"
51"
18"
AFF
WALL MOUNTED
CONTROL PANEL
HEIGHT DIMENSION
I
NVERTERS ARE
EXTERNIALY MOUNTED
FOR WALL MOUNTED
CONTROL PANELS
PLAN VIEW
FRONT VIEW
DUAL CONTROL PANEL
MINIMUM CLEARANCE
FRONT 36"
SIDE 12"
REAR 0"
Cleveland Range reserves right of design improvement or modification, as warranted.
MODEL ELECTRICAL
208V/
3PH/60Hz
HA-DE-CC (floor mount)
HA-DE-CC/W (wall mount)
IA-DE-CC (floor mount)
IA-DE-CC/W (wall mount)
AMPERAGE
BASED ON
KETTLE SIZE
THE DEPTH AND WIDTH DIMENSIONS ARE THE SAME
FOR BOTH THE FLOOR MOUNT AND WALL MOUNT
CONTROL PANELS.
ELECTRICAL POWER TO AND FROM CONTROL PANEL
• CONTRACTOR MUST CUT ENTRY HOLE
• TOP OR BOTTOM POWER ENTRY RECOMMENDED
• MUST USE PROPER CONNECTIONS TO MAINTAIN
U.L. LISTING
(NOT TO SCALE)
SECT. XIV PAGE 18
0609
Litho in USA