Cleveland ES2446 User Manual

Cleveland
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
STEAMCRAFT®GENERATOR STYLE HIGH SPEED CONVECTION STEAMERS
SteamCraft®Ultra 3 & 5 Stacking Equipment Stand
OPEN TYPE STAND, ALL STAINLESS STEEL SLIDING SHELF, ONE SET OF PAN RACKS
Cleveland Standard Features
II
Stand designed specifically for mounting two 21CET8 Steamers or One 21CET8 and One 21CET16 or Two 21CET16’s
II
All Stainless Steel welded construction with 1.25" square Tubing
II
Adjustable Flanged Feet (rear) for Floor Bolting
I
I
Sliding Shelf provided at bottom
II
Standard with one set of Pan Racks
II
Includes Plumbing for a single common Water Line connection, and common Drain Line connection for both units (21CET8 or 21CET16)
II
Comes with two sets of Mounting Bolts to attach units on to a Stainless Steel Platform
MODEL: ES2446
Model ES-2446
Options & Accessories
Ë Pan Racks (PR-ES)
Ë Perforated Cafeteria Pans (PP)
Ë Solid Cafeteria Pans (SP)
Model ES2446 shown with optional 21CET8 Steamers
Short Form Specifications
Shall be CLEVELAND, Stacking Equipment Stand designed to stack two (2) 21CET8 ES2446, Open type stand with provision for one set of Pan Racks. All Stainless Steel Welded Construction with 1.25" square Tubing. Furnished with Level Adjustable Flanged Feet for bolting to floor.
SteamCraftUltra 3
Steamers. Model
SECT. IV PAGE 23
0609
74.78”
1899mm
48.34”
1288mm
19.53”
496mm
5.78”
147mm
1.34”
37mm
24.00”
610mm
29.00”
737mm
22.00”
559mm
50.80”
1290mm
1
.02”
259mm
2
0.32”
5
16mm
1.02”
259mm
3
.05”
776mm
4.00”
119mm
6.00”
170mm
10.00”
264mm
FRONT VIEW
R
IGHT SIDE VIEW REAR VIEW
C
CDC
D
*NOTES: The diagrams above are shown with the model 21-CET-8 mounted on the
ES-2446 Stacking Equipment Stand. Cleveland’s ES-2446 model Stacking Equipment Stand does not include
the model 21-CET-8 SteamCraft The SteamCraft
®
Ultra 3 must be specified, and priced separately from the
®
Ultra 3 Steamer.
model ES-2446.
D
ELECTRIC
Two separate electrical connections are required
VOLTAGE KW 1PH AMPS 3PH AMPS
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4.
each / total each / total each / total
208 8.5 / 17 41 / 82 25 / 50
220 8.0 / 16 35 / 70 21 / 42
240 9.0 / 18 39 / 78 23 / 46
440 8.0 / 16 18 / 36 11 / 22
480 9.0 / 18 29 / 58 12 / 24
WATER DRAINAGE CLEARANCE
1
Cold water:
35 psi minimum 60 psi maximum
1
2˝ NPT Tubing:
Two
• one for Condenser
• one for Steam Generator
1
4˝ N.P.T. tube
Do not connect other units to this drain.
Drain line must be vent­ed.
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoining wall or equipment is over 30” high for service access)
Contact factory for variances to clearances.
WATER QUALITY REQUIREMENTS
The quality of water varies greatly from region to region. Steam equipment generators must be drained daily and chemically descaled periodically to ensure proper operation. To minimize service problems caused by the accumula­tion of minerals and chemi­cals in water review the following quality guidelines with a local water treatment specialist. Inlet water that is beyond these specified guidelines should be treated to achieve these acceptable limits. Total Dissolved Solids less than 60 ppm, Alkalinity less than 20 ppm, Silica less than 13 ppm, pH factor greater than
7.5, Chlorine less than 30 ppm.
(NOT TO SCALE)
SECT. IV PAGE 24
Litho in U.S.A.
0609