COMBI OVEN-STEAMER Options & Accessories
MODEL: C9797-K2PF
Kleensteam II
(for Combi's with a Generator, models OEB & OGB):
(with Prefilter, two Carbon-Block Cartridges & one Scale Stick Cartridge)
Cleveland Standard Features :
Kleensteam II
I
I
Recommended filter delivering high quality filtered water with scale
inhibition
I
I
System includes: one prefilter, two carbon-block cartridges and one scale stick cartridge.
I
I
Dual cartridge design provides enhanced performance for low or high flow capacity steamers
I
I
2 five micron carbon block filters improve performance, maximize energy efficiency and increase the life of combi oven steamers
I
I
Reduces chlorine-induced corrosion
I
I
Long lasting SS-10 cartridge is more effective in higher alkalinity/hardness/TDS/temperature installations.
I
I
Sophisticated Hydroblend compound prevents limescale formation in high temperature steam applications
I
I
System is simple to install, operate and maintain
Prefilter:
I
I
Filters out larger dirt and rust particles
I
I
Extends the life of primary filter cartridges
I
I
Tightly spun EC210 sediment cartridge delivers 10 micron nominal filtration
I
I
Durable slim bowl design makes cartridge change outs easy to handle
I
I
Clear housing allows for visually inspection of trapped particles and makes determining when to change the cartridge easy
Prefilter
Kleensteam II
Short Form Specifications
Shall be Cleveland Model C9797-K2PF Kleensteam II with one prefilter, two carbon-block cartridges and one scale stick cartridge, dual cartridge design for Combi's with a Generator, models OEB & OGB, 2 five micron carbon block filters and SS-10 cartridge for higher alkalinity / hardness / TDS / temperature installations.
Options and Accessories
Ë Replacement Cartridges
SECT. IIB PAGE 12A
0810
2
0.50”
5
21mm
5.16”
131mm
25.50”
521mm
22.44”
570mm
O
utlet to
C
ombi
O
ven-Steamer
Inlet
3/4” FNPT
Kleensteam II
for Combi's with a Generator, models OEB & OGB):
(
(with Prefilter, two Carbon-Block Cartridges & one Scale Stick Cartridge)
Technical Data
Overall Dimensions:
Inlet Connection:
Outlet Connection:
Service Flow Rate:
Pressure Requirements:
Maximum Water Temperature at Inlet: 100°F (38°C)
Alkalinity Range: 2 to 12 grains per gallon
Electrical: No electrical connection required
Shipping Weight:
Operating Weight:
25.50”H x 20.50”W x 7.00”D
3/4” FNPT
3/4” FNPT
Maximum 3.5 gpm (13.2 Lpm) - twin cartridges
10 - 125 psi (0.7 – 8.6 bar), non-shock
34 lbs.
42 lbs.
Kleensteam IIPrefilter
The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts.
NSF Certified under NSF/ANSI Standard 42 for materials
NOTES: