CLASSIC CONVECTION STEAMERS 15 PSI BOILER BASE STYLE
CONVECTION
Cleveland Classic Series
STEAMERS
TWO COMPARTMENT, PRESSURELESS, PLUS ONE 6 GALLON KETTLE, 200, 300M BTU GAS FIRED STEAM GENERATOR 42” WIDE CABINET BASE DESIGN, with NICKELGUARD™
Cleveland Standard Features
II
Cooking Capacity for up to six 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans.
I
I
Pressureless cooking with forced convection steam, permitting doors to be opened while cooking continues.
II
Solid State Controls operate water level and safety functions.
II
Each compartment is equipped with a 60 minute mechanical timer, separate bypass switch for constant steaming and a cold water condenser for superior cooking results.
II
Instant Steam Standby Mode: Holds generator at steaming temperature. Allows unit to start cooking instantly.
II
Durable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
II
Separate Main Power Switch for “On/Off”
II
Exclusive Steam Cooking Distribution System:
Convection Jets produce a high velocity convection steam without fans. Coved Corner design in cooking compartment distributes heat evenly and is easy to keep clean. Creased top & bottom enhance drainage. Cold Water Condenser for each compartment maintains a dry steam. Fully insulated cooking compartment for thermal efficiency. Removable Stainless Steel Slide Racks for easy cleaning.
II
Exclusive “Cool to the Touch” Compartment Door Design:
Free floating inner door with reversible door gasket provides an air tight seal. Stainless Steel Slam/Latch Door Latch mechanism provides greater reliability.
II
Left Hand Door Hinging: Compartment Doors hinged left, controls on the right.
II
Modular Cabinet Base with Hinged Door.
II
High Efficiency Gas Steam Generator with Electronic Spark Ignition and Automatic Water Fill on start up.
II
Automatic Generator Drain at shutdown: Large 3⁄4˝ drain valve contains a “Water Jet” Spray Rinse Cleaning Cycle to keep drain clear.
II
Automatic Water Level Control System with Low Water Power Cut-Off.
II
Steam generator equipped with High Limit Pressure Safety Switch, 15 psi Safety Valve, and Steam Generator Pressure Gauge.
II
NSF Certified 6˝ Stainless Steel Legs with adjustable flanged feet for a one inch level adjustment.
II
Gas Pressure Regulator and Control Valve. Standard Voltage for Control: 115 volts, 60 Hz, single phase.
II
II
Table Top includes 2˝ deep Drain Trough with 3⁄4˝ Drain and Grate 6 gallon Tilting Kettle made of type 304 Stainless Steel, 2⁄3jacketed
II
Kettle includes:
II
Trunnion mounted Steam Control Valve
II
50 psi Kettle Steam Jacket Rating
II
Lift Off Cover
II
Double Pantry Faucet with Swing Spout
II
Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
The
exclusive
MODELS:
42-CKGM-20042-CKGM-300
Shown with optional Electronic Timer
Short Form Specifications
Shall be Two Compartments, CLEVELAND Convection Steamer, plus one 6 gallon Direct Steam, tilting, kettle, Model 42-CKGM- _____ , Gas-fired Steam Generator, NickelGuard, _____ M BTU. Solid State Controls operate timing, water level and safety functions. Steam Generator with Automatic Water Fill on start-up, Automatic Blowdown with additional Manual Drain Valve and Electronic Spark Ignition. For each cooking compartment: 60 minute Mechanical Timer, Manual Operation Mode and Cold Water Condenser. Type 304 Stainless Steel cooking compartment.
Options & Accessories
Ë Right Hand Door Hinging, Controls and Kettles on the Left (DHR) Ë Electronic Timer with Compensating Load Feature (ETC) Ë ON/OFF Steam Switch only for compartment controls (MC) Ë Compartment Door Steam Shut Off Switch (SCS) Ë Cafeteria pans in depths of 1˝, 2 Ë Power Take Off Kit (GPTO), Kettle Interconnecting Kit (IMK) Ë Correctional Packages Ë Stainless Steel Base Frame (FSS) Ë Stainless Steel Insulated Flue Cover (SSF) Ë Quick Disconnect for gas line (QDC) Ë Type 316 Stainless Steel Liner for high acid products (316-6G) Ë Boiler Descaling Pump Kit (107142) Ë Water Filters Ë Rear Gas Connection (RGT) Ë
Compartment Door Steam Shut Off Switch
1
2˝, 4˝ and 6˝
SECT. III PAGE 19
0609
ACTUAL CAPACITIES: Kettle 6 gallons/23 liters or 192, 4 oz. servings.
• Other size servings may be calculated.
Each compartment has capacity for:
• Three, 12˝ x 20˝ x 2
1
2˝ or six, 12˝ x 20˝ x 1˝
deep Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality stan­dards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
of the steam
Right - 6”, Left - 6”, Rear - 6” on control side if adjoining wall or equipment is over 30” high for
5.0 Amps
** Do not connect to GFI outlet. See note below.
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, NSF and CSA (AGA, CGA).
1 1/2” IPS common drain. Do not connect other units to this drain. Do not use PVC pipe for drain.
service access)
For use in non­combustible locations.
Contact factory for variances to clearances
(12”
(NOT TO SCALE)
SECT. III PAGE 20
0609