PRESSURE/CONVECTION STEAMERS
PRESSURE/CONVECTION
®
SteamPro XVI
STEAMERS
LARGE COMPARTMENTS, HIGH VOLUME
300M BTU GAS FIRED STEAM GENERATOR
36” WIDE CABINET BASE DESIGN with NICKELGUARD™
Cleveland Standard Features
I
I
Cooking Capacity for up to eight 12" x 20" x 21⁄2˝ deep
Cafeteria Pans per compartment, or four 18˝ x 26˝ Buns Pans.
I
I
Each compartment can operate independently as a pressure
steamer, or as a convection steamer, user selectable.
II
In the Convection Mode; Pressureless cooking with
convection steam, permitting doors to be opened while
cooking continues.
I
I
In the Pressure Mode; door is locked and sealed,
compartment operates at 5 psi steam pressure
II
Solid State Controls operate water level and safety functions.
II
Each compartment is equipped with a 60 minute mechanical
timer, separate bypass switch for constant steaming
(Convection only).
Durable 10 Gauge Stainless Steel Construction:
II
For Compartment Door and Steam Cooking Cavity.
II
Separate Main Power Switch for “On/Off”
II
Exclusive Steam Cooking Distribution System: The
Exclusive Convection Jets produce a high velocity
convection steam without fans. Coved Corner design in
cooking compartment distributes heat evenly and is easy to
keep clean. Creased bottom enhances drainage. Cold
Water Condenser for each compartment maintains a dry
steam. Fully insulated cooking compartment for thermal
efficiency. Removable Stainless Steel Slide Racks for easy
cleaning.
II
Heavy duty, one piece, solid compartment door design
with replaceable door gasket
II
Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
II
Heavy duty Stainless Steel Base Frame: 36˝ modular
cabinet
II
High Efficiency Gas Steam Generator with NickelGard,
Electronic Spark Ignition and Automatic Water Fill on start up.
II
Automatic Generator Drain at shutdown: Contains a
“Water Jet” Spray Rinse Cleaning Cycle to keep drain clear.
II
Automatic Water Level Control System with Low Water
Power Cut-off Circuit.
II
Steam generator equipped with High Limit Pressure Safety
Switch, 15 psi Safety Valve, and Steam Pressure Gauge.
NSF Certified 6˝ Stainless Steel Legs with adjustable
II
flanged feet for a one inch level adjustment.
II
Gas Pressure Regulator and Control Valve.
II
Standard Voltage for Control: 115 volts, 60 Hz, single phase.
II
All Controls are serviceable from the front.
II
Compartment Door Steam Shut Off Switch.
II
Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT.
NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
MODEL: 36-PCGM-300
Shown with optional
Electronic Timer
Short Form Specifications
Shall be Two Compartments, CLEVELAND Pressure/Convection Steamer,
Gas-fired Steam Generator, Model 36-PCGM-300, NickelGard, 300M gas,
115 volts, 60 Hz, single phase. Pressure/Convection Modes to be selectable
at user’s option with no restrictions as to any combination of modes. Type 304
Stainless Steel cooking compartment. Insulated cooking compartments. One
60 minute Mechanical Timer with Touch Control per compartment. Audible
and Visual Signals for cycle completion and steam shut-off. Separate visual
indication for each operational mode.
Options & Accessories
Ë Electronic Timer with Compensating Load Feature. (ETC)
Ë Cafeteria pans in depths of 1˝, 2
Ë 18˝ x 26˝ Bun Pans
Ë Stainless Steel Insulated Flue Cover (SSF)
Ë Quick Disconnect for gas line (QDC)
Ë Correctional Packages
Ë Boiler Descaling Pump Kit (107142)
Ë Water Filters
Ë Rear Gas Connnection (RGT)
1
⁄2˝, 4˝ and 6˝
SECT. V PAGE 3
0609
Each compartment has capacity for:
•
Eight, 12˝ x 20˝ x 2
1
⁄2˝ deep Cafeteria Pans. Can
accomodate four, 18˝ x 26˝ Bun Pans.
Many regional, state and local codes exist and it is the
•
responsibility of the owner and installer to comply with
those codes.
Cleveland Range equipment is built to comply with
•
applicable standards for manufacturers. Included
among those approval agencies are: UL, A.G.A.,
NSF, ASME/N.Bd., CSA, CGA, ETL, and others.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it will
be suitable for the generator.
1 1/2” IPS common drain.
Do not connect other units
3
⁄8˝ NPT
5.0 Amps
** Do not connect to GFI
outlet. See note below.
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).
Condenser feed
1
⁄2˝ NPT
Boiler Feed
to this drain.
The Floor Drain must be
located outside the confines of the equipment.
Do not use PVC pipe for
drain.
Right - 6”, Left - 6”, Rear - 6”
(12” on control side if adjoining
wall or equipment is over 30”
high for service access)
For use in non-combustible
locations.
Contact factory for
variances to clearances.
(NOT TO SCALE)