MODULAR BASES
MODULAR BASE WITH KETTLES
200M BTU GAS-FIRED STEAM GENERATOR with NICKELGUARD™ ONE 3 GALLON KETTLE AND ONE 6 GALLON KETTLE CABINET BASE: 36" (900MM) WIDE
Cleveland Standard Features
II
Factory assembled Kettle/Steam Generator NickleGard Base combination with one 3 gallon and one 6 gallon kettle with 200M BTU Gas-Fired Steam Generator
II
Solid State steam generator Water Level Controls
II
Low Water Safety Cut-Off
II
II
Type 430 Stainless Steel exterior enclosure, and table top (with Drain Trough which has 1.50" diameter male drain), #4 exterior finish
II
Type 304 Stainless kettle(s), #4 exterior finish
II
Separate "Start/Reset" Illuminated Switch Controls, plus Pressure Gauge
II
Solid State Electronic Spark Ignition for energy savings
II
Major components serviceable from the front of the unit
II
Kettle(s) are 2/3 Steam Jacket rating, and include Lift-off Covers
II
Hot and Cold Water Faucet with Swing Spout
II
Kettle(s) have 50 psi Steam Jacket Rating, 50 psi chrome plated Safety Valve(s) and Manual Tilting, balanced design
II
Tilt Handles can be mounted on either side
II
Steam Generator empties under pressure (blowdown) automatically upon each Shut-Down. Automatic Water Refill on Start-Up
II
Standard voltage for controls is 115 volt, 60 Hz, single phase
II
Adjustable Flanged Feet (FF-A)
II
Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
Options & Accessories
MODELS: 36-GM-K36-200
Short Form Specifications
Shall be CLEVELAND, Modular Cabinet Base with one 3 gallon and one 6 gallon kettle, Model 36-GM-K36-200, 200M Nickelguard BTU Gas-Fired Steam Generator, type 430 Stainless Steel exterior enclosure, Table Top, Back Splash and 4 level adjustable feet. 2/3 Steam Jacketed type 304 Stainless Steel kettle(s) with 50 psi Steam Jacket Rating; needle type Steam Control Valve on each kettle. Console mounted Controls, Pressure Gauge and Illuminated "Start/Reset" Control Switches. Solid State Water Level Steam Generator Controls and Electronic Spark Ignition. Steam Generator drains under pressure (blowdown) after each Shut-Down with Automatic Water Refill on Start-Up. 15 psi Safety Valve
Ë Power Take-Off Kit (GPTO) Ë Gas, other than natural Ë Type 316 Stainless Steel kettle interior for high acid food
products (316)
Ë Food Strainers (FS) Ë Stainless Steel Base Frame (FSS) Ë 300,000 BTU Gas-Fired Boiler with Nickelguard Ë Boiler Descaling Pump Kit (107142)
SECT. VII PAGE 25
0609
6.00”
6.00”
6.00”
CAPACITIES
(in 4 oz. servings)
Other sizes may be calculated.)
(
3 gallon / 11 liters ..... 48 per kettle
6 gallon / 23 liters ..... 160 per kettle
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water
upply is potable is not proof that it will be suitable for the generator.
s
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).
(NOT TO SCALE)
SECT.
VII PAGE 26
Litho in U.S.A.