MODULAR BASES
MODULAR BASE WITH KETTLES
200M or 300M BTU GAS-FIRED STEAM GENERATOR with NICKELGUARD™
TWO 10 GALLON KETTLES
CABINET BASE: 36" (900MM) WIDE
Cleveland Standard Features
II
Factory assembled Kettle/Steam Generator NickleGard Base
combination with two 10 gallon kettles with 200M or 300M
BTU Gas-Fired Steam Generator
II
Solid State steam generator Water Level Controls
II
Low Water Safety Cut-Off
II
Pressure Limit Controls with 15 psi Safety Valve
II
Type 430 Stainless Steel exterior enclosure, and table top
(with Drain Trough which has 1.50" diameter male drain),
#4 exterior finish
II
Type 304 Stainless kettles, #4 exterior finish
II
Separate "Start/Reset" Illuminated Switch Controls, plus
Pressure Gauge
II
Solid State Electronic Spark Ignition for energy savings
II
Major components serviceable from the front of the unit
II
10 gallon kettles are 2/3 Steam Jacketed and include
Lift-off Covers and Splash Guard
II
Hot and Cold Water Faucet with Swing Spout
II
Kettles have 50 psi Steam Jacket Rating, 50 psi chrome
plated Safety Valves and Manual Tilting, balanced design
II
Tilt Handles can be mounted on right side
II
Steam Generator empties under pressure (blowdown)
automatically upon each Shut-Down, Automatic Water
Refill on Start-Up
II
Standard voltage for controls is 115 volt, 60 Hz,
single phase
II
6" Stainless Steel Legs with Adjustable Flanged Feet (FF-A)
II
Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT.
NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
MODELS: 36-GM-K1010-200
36-GM-K1010-300
Short Form Specifications
Shall be CLEVELAND, Modular Cabinet Base with two 10 gallon kettles, Model
36-GM-K1010 -____ , 200M or 300M BTU Nickelguard Gas-Fired Steam
Generator, type 430 Stainless Steel exterior enclosure, Table Top, Back
Splash and 4 level adjustable feet. 2/3 Steam Jacketed type 304 Stainless
Steel kettles with 50 psi Steam Jacket Rating. Console mounted Controls,
Pressure Gauge and Illuminated "Start/Reset" Control Switches. Solid State
Water Level Steam Generator Controls and Electronic Spark Ignition. Steam
Generator drains under pressure (blowdown) after each Shut-Down with
Automatic Water Refill on Start-Up. 15 psi Safety Valve
Options & Accessories
Ë Power Take-Off Kit (GPTO)
Ë Gas, other than natural
Ë Type 316 Stainless Steel kettle interior for high acid food
products (316)
Ë Food Strainers (FS)
Ë Stainless Steel Base Frame (FSS)
Ë Boiler Descaling Pump Kit (107142)
SECT. VII PAGE 31
0609
H
C1
C1
D
D
C2
H
C2
GAS FLUE
2
8.31"
7
19mm
2.03"
52mm
5
.00"
1
27mm
19.00"
482mm
3.50"
89mm
24.00"
610mm
2
5.88"
657mm
2
9.56"
7
51mm
37.00"
940mm
3
.00"
7
6mm
6.12"
155mm
6.68"
170mm
29.65"
753mm
30.81"
782mm
35.43"
900mm
5.38"
137mm
1.38"
35mm
6.00"
152mm
7.50"
191mm
9.00"
229mm
12.50"
318mm
30.00"
762mm
62.00"
1575mm
32.21"
818mm
1.61"
41mm
1.61"
41mm
I.D.
15.75"
400mm
17.00"
432mm
WATER QUALITY
REQUIREMENT
The recommended minimum water quality
standards whether untreated or pretreated, based upon 10 hours of use per
day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS
less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for
an on site water analysis for recommendations concerning steam generator feed water
treatment (if required), in order to remove or
reduce harmful concentrations of minerals.
The use of highly mineralized water will
mean that more frequent servicing of the
steam generator will be necessary. The fact
that a water supply is potable is not proof
that it will be suitable for the generator.
CAPACITIES: (in 4 oz. servings,
other sizes may be calculated.)
10 Gallon / 36 liters . . . . . . .320 servings
ELECTRIC
50 watts for generator
115 V-1 PH
** Do not connect to GFI outlet. See
note below.
WATER
C1: 1/4" IPS Cold water for boiler
C2: 3/8" NPT Cold water for faucet
C2: 3/8" NPT Hot water for faucet
DRAIN
GAS
NATURAL
3/4" IPS for 200,000
1.00" IPS for 300,000
Supply Pressure
4.00" W.C. Minimum
14.00" W.C. Maximum
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).
PROPANE
3/4" IPS for 200,000
1.00" IPS for 300,000
Supply Pressure
12.00" W.C. Minimum
14.00" W.C. Maximum
1 1/2" IPS Common Drain
The floor drain must be
located outside the confines
of the equipment.
Do not connect to any other drain.
CLEARANCES
Right: 6.00"
Left: 6.00"
Rear: 6.00"
(NOT TO SCALE)
SECT. VII PAGE 32
0609