CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
CONVECTION
®
ConvectionPro XVI
TWO LARGE COMPARTMENTS
PRESSURELESS, DIRECT STEAM
36” WIDE CABINET BASE DESIGN
Cleveland Standard Features
II
Cooking Capacity for up to eight 12˝ x 20˝ x 21⁄2˝ deep
Cafeteria Pans per compartment or four 18˝ x 26˝ Bun Pans.
II
Pressureless cooking with forced convection steam,
permitting doors to be opened while cooking continues.
II
Each compartment is equipped with a 60 minute
mechanical timer, separate bypass switch for constant
steaming and a cold water condenser for superior
cooking results.
II
Durable 10 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity
II
Separate Main Power Switch for “On/Off”
II
Exclusive Steam Cooking Distribution System: The
exclusive Convection Jets produce a high velocity
convection steam without fans. Coved Corner design in
cooking compartment distributes heat evenly and is easy
to keep clean. Creased bottom enhances drainage. Cold
Water Condenser for each compartment maintains a dry
steam. Fully insulated cooking compartment for thermal
efficiency. Removable Stainless Steel Slide Racks for
easy cleaning.
II
Heavy duty, one piece, solid compartment door design
with replaceable door gasket.
II
Left Hand Door Hinging: Compartment Doors hinged left,
control on the right.
II
Modular Cabinet Base with Hinged Door.
II
Heavy duty Stainless Steel Base Frame
II
Moisture Separator Trap for incoming steam
II
Pressure Reducing Valve: For 35-50 psi incoming steam
pressure based on a
II
Single Cold Water Connection
II
NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
II
Standard voltage for controls 115 volts, 60 Hz, single phase.
II
All Controls are serviceable from the front.
II
Compartment Door Steam Shut Off Switch.
3
⁄4˝ steam line. (minimum size)
STEAMERS
MODEL: 36-CDM-16
Shown with optional
Electronic Timer
Short Form Specifications
Shall be Two Large Compartments, CLEVELAND Convection Steamer, Direct
Steam, Model 36-CDM-16. Solid State Controls operate timing, water level
and safety functions.Type 304 Stainless Steel cooking compartment.
Insulated cooking compartments. One 60 minute Mechanical Timer with
Touch Control per compartment. Audible and Visual Signals for cycle completion and steam shut-off.
Options & Accessories
Ë Electronic Timer with Compensating Load Feature. (ETC)
Ë ON/OFF Steam Switch for compartment controls (MC)
Ë Cafeteria pans in depths of 1˝, 2
Ë 18˝ x 26˝ Bun Pans
Ë Voltages for controls other than standard
Ë Correctional Packages
Ë Second Pressure Reducing Valve for 50-120 psi steam pres-
sure (PRV)
1
⁄2˝, 4" and 6˝
JJ
Clean non-toxic, uncontaminated steam is required
for all “Direct Steam” steamers
SECT. III PAGE 31
0609
ach compartment has capacity for:
E
Eight, 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans. Can
•
ccomodate 18˝ x 26˝ Bun Pans.
a
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
hether untreated or pre-treated, based upon 10 hours of
w
use per day, and a Daily Blowdown, are as follows:
OTAL DISSOLVED SOLIDS less than 60 parts per million
T
TOTAL ALKALINITY less than 20 parts per million
ILICA less than 13 parts per million
S
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
ater analysis for recommendations concerning steam
w
generator feed water treatment (if required), in order to
emove or reduce harmful concentrations of minerals. The
r
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it
will be suitable for the generator.
1 1/2” IPS common drain.
Do not connect other units to
this drain.
Floor Drain must be located
outside the confines of the
equipment base
Drain line must be vented
Do not use PVC pipe for drain
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA.
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoining
wall or equipment is over 30”
high for service access)
Contact factory for
variances to clearances.