CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
CONVECTION
Cleveland Classic Series
STEAMERS
TWO COMPARTMENT, PRESSURELESS
DIRECT STEAM
36” WIDE CABINET BASE DESIGN
Cleveland Standard Features
II
Cooking Capacity for up to six 12˝ x 20˝ x 21⁄2˝ deep Cafeteria
Pans.
II
Pressureless cooking with forced convection steam,
permitting doors to be opened while cooking continues.
II
Each compartment is equipped with a 60 minute mechanical timer, separate bypass switch for constant steaming and
a cold water condenser for superior cooking results.
II
Durable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
II
Separate Main Power Switch for “On/Off”
II
Exclusive Steam Cooking Distribution System: The
exclusive Convection Jets produce a high velocity
convection steam without fans. Coved Corner design in
cooking compartment distributes heat evenly and is easy to
keep clean. Creased top & bottom enhance drainage. Cold
Water Condenser for each compartment maintains a dry
steam. Fully insulated cooking compartment for thermal
efficiency. Removable Stainless Steel Slide Racks for easy
cleaning.
II
Exclusive “Cool to the Touch” Compartment Door
Design: Free floating inner door with reversible door gasket
provides an air tight seal. Stainless Steel Slam/Latch Door
Latch mechanism provides greater reliability.
II Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
II
Modular Cabinet Base with Hinged Door.
II
Moisture Separator Trap for incoming steam.
II
Pressure Reducing Valve: For 15-50 psi incoming steam
pressure based on a
II
Single Cold Water Connection
II
NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
II
Standard Voltage for Controls: 115 volts, 60 Hz, single
phase.
II
All Controls are serviceable from the front.
3
⁄4˝ steam line. (minimum size)
MODEL: 36-CDM
Shown with optional
Electronic Timer
Short Form Specifications
Shall be Two Compartments, CLEVELAND Convection Steamer, Model 36CDM, Direct Steam, 115 volts, single phase. For each cooking compartment;
60 minute Mechanical Timer, Manual Operation Mode and Cold Water
Condenser. Type 304 Stainless Steel cooking compartment.
Options & Accessories
Ë Right Hand Door Hinging, Controls on the Left. (DHR)
Ë Electronic Timer with Compensating Load Feature. (ETC)
Ë Compartment Door Steam Shut Off Switch. (SCS)
Ë ON/OFF Steam Switch only for compartment controls (MC)
Ë Cafeteria pans in depths of 1˝, 2
Ë Voltages for controls other than standard
Ë Stainless Steel Base Frame (FSS)
Ë Second Pressure Reducing Valve for 50-120 PSI steam pres-
sure (PRV)
Ë Correctional Packages
1
⁄2˝, 4˝ and 6˝
JJ
Clean non-toxic, uncontaminated steam is required
for all “Direct Steam” steamers
SECT. III PAGE 15
0609
ach compartment has capacity for:
E
•
Three, 12˝ x 20˝ x 2
afeteria Pans.
C
1
⁄2˝ or six, 12˝ x 20˝ x 1˝ deep
WATER QUALITY REQUIREMENT
The recommended minimum water quality
standards whether untreated or pre-treated, based
upon 10 hours of use per day, and a Daily
Blowdown, are as follows:
OTAL DISSOLVED
T
SOLIDS less than 60 parts per million
OTAL ALKALINITY less than 20 parts per million
T
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on
site water analysis for recommendations concerning
steam generator feed water treatment (if required),
in order to remove or reduce harmful concentrations
of minerals. The use of highly mineralized water will
mean that more frequent servicing of the steam
generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable
for the generator.
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if
adjoining wall or equipment
is over 30” high for service
1 1/2” IPS common drain.
Do not connect other units to
this drain.
Do not use PVC pipe for drain.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, /NSF and CSA.
acess)
Contact factory for
variances to clearances.
(NOT TO SCALE)