WIRING DIAGRAM
POWER IN
DMX
CABLE
POWER
IN
+
-
SC
H
DM
X
L = 1.5 mt.
L = 1.5 mt.
N
F
ODEON
POWER IN
CABLE
AC LINE
AC LINE
FOR NEXT
FIXTURE
EXAMPLE OF POWER
CONNECTION VIA
COMMERCIAL IP65 (or better)
JUNCTION BOX (NOT INCLUDED)
-
+
ODEON
DMX
CABLE
FROM
FIXTURE OR
CONTROLLER
TO NEXT
FIXTURE
EXAMPLE OF POWER
CONNECTION VIA
COMMERCIAL JUNCTION BOX
IP 65 ( NOT INCLUDED )
!
WARNING
TO AVOID ELECTRIC SHOCK, DISCONNECT MAIN POWER SUPPLY BEFORE CARRYING OUT ANY ELECTRICAL WORK.
SCH
WIRING DIAGRAM
-
+
S C H
POWER
-
+
S C H
DMX
-
+
S C H
POWER
-
+
S C H
DMX
-
+
S C H
POWER
-
+
S C H
DMX
TO AC MAINS
POWER LINE
TO DMX
CONTROLLER
TO NEXT FIXTURE
NOTICE
THE POWER CABLE SIZES MUST BE PROPERLY CALCULATED ACCORDING TO THE TOTAL LINE LOAD
NOTICE
CABLE DMX LINE MUST COMPLY WITH USITT DMX512-A
ASYNCHRONOUS SERIAL DIGITAL DATA TRANSMISSION STANDARD FOR CONTROLLING LIGHTING EQUIPMENT AND ACCESSORIES.
FOR OUTDOOR INSTALLATIONS, USE WEATHERPROOF JUNCTION BOXES AND SEAL ALL POSSIBLE WATER ENTRY POINTS AND COVERS (JUNCTION BOXES AND SEALING NOT INCLUDED)
!
WARNING
FOR THE FOLLOWING MODELS:
ODEON FLOOD MAXI 15° RGBW ODEON FLOOD MEDIUM 15° RGBW ODEON FLOOD MINI 15° RGBW
ODEON FLOOD MAXI 25° RGBW ODEON FLOOD MEDIUM 25° RGBW ODEON FLOOD MINI 25° RGBW
ODEON FLOOD MAXI 35° RGBW ODEON FLOOD MEDIUM 35° RGBW ODEON FLOOD MINI 35° RGBW
FOR THE FOLLOWING MODELS:
ODEON FLOOD MAXI 25° RGBW ODEON FLOOD MEDIUM 25° RGBW ODEON FLOOD MINI 25° RGBW
ODEON FLOOD MAXI 35° RGBW ODEON FLOOD MEDIUM 35° RGBW ODEON FLOOD MINI 35° RGBW
ODEON FLOOD MAXI 15° RGBW ODEON FLOOD MEDIUM 15° RGBW ODEON FLOOD MINI 15° RGBW
WIRING DIAGRAM
TO DMX
CONTROLLER
TO AC MAINS
POWER LINE
NOTICE
THE POWER CABLE SIZES MUST BE PROPERLY CALCULATED ACCORDING TO THE TOTAL LINE LOAD
WIRING DIAGRAM
POWER
+
DMX
S C
-
+
H
S C
-
H
WARNING
!
TO AVOID ELECTRIC SHOCK, DISCONNECT MAIN POWER SUPPLY BEFORE CARRYING OUT ANY ELECTRICAL WORK.
AC LINE
EXAMPLE OF POWER
CONNECTION VIA
COMMERCIAL IP65 (or better)
!
JUNCTION BOX (NOT INCLUDED)
WARNING : INSTALLATION MUST BE CARRIED OUT IN ACCORDANCE WITH NATIONAL LAW BY QUALIFIED STAFF. FAILURE TO COMPLY WITH THE GENERAL INSTALLATION GUIDELINES MAY RESULT IN SERIOUS DAMAGE.
ODEON
POWER IN
CABLE
F
AC LINE
FOR NEXT
FIXTURE
N
DMX
S C
-
+
H
POWER
S C
-
+
H
POWER IN
NOTICE
CABLE DMX LINE MUST COMPLY WITH USITT DMX512-A
ASYNCHRONOUS SERIAL DIGITAL DATA TRANSMISSION STANDARD FOR CONTROLLING LIGHTING EQUIPMENT AND ACCESSORIES.
L = 1.5 mt.
L = 1.5 mt.
DM
X
SC
H
-
+
POWER
IN
DMX
CABLE
WARNING
!
FOR OUTDOOR INSTALLATIONS, USE WEATHERPROOF JUNCTION BOXES AND SEAL ALL POSSIBLE WATER ENTRY POINTS AND COVERS (JUNCTION BOXES AND SEALING NOT INCLUDED)
FROM
FIXTURE OR
CONTROLLER
COMMERCIAL JUNCTION BOX
IP 65 ( NOT INCLUDED )
POWER
ODEON
DMX
CABLE
-
S C
-
+
H
SCH
+
EXAMPLE OF POWER
CONNECTION VIA
DMX
S C
-
+
H
TO NEXT FIXTURE
TO NEXT
FIXTURE
Loading...