2 1. Safety information
3 2. Unpacking and preparation
4 3. Installation and start-up
4 3.1 Installing the fixture
4 3.2 Connecting to manis supply
5 3.3 Connecting the control signal line: DMX / Art-Net
5 3.4 Switching on the fixture and basic SetUp
9 4.3 Effects module removal
11 4.4 Cleaning of the filters
13 4.5 Rotating gobos
14 4.6 Battery removal
15 5. Specifications
Congratulations on choosing a Claypaky product!
We thank you for your custom.
Please note that this product, as all the others in the
rich Claypaky range, has been designed and made with
total quality to ensure excellent performance and best
meet your expectations and requirements.
1. SAFETY INFORMATION
EN
IT
DE
ES
SAFETY INFORMATION
IMPORTANT: Claypaky recommends you carefully read and keep the safety information on this product, also
available in digital format at the following link:
www.claypaky.com
Ref: FIS00T - Safety Information Axcor 400 series
INFORMAZIONI DI SICUREZZA
IMPORTANTE: Claypaky raccomanda di leggere accuratamente e conservare le informazioni di sicurezza relative
a questo prodotto, sempre reperibili in versione digitale al seguente link:
www.claypaky.com
Rif: FIS00T - Safety Information Axcor 400 series
NFORMATIONEN ZUR SICHERHEIT
I
WICHTIG: Claypaky empfiehlt, die Sicherheitsinformationen bezüglich dieses Produkts genau zu lesen und
aufzubewahren. Sie sind in Digitalversion immer unter folgendem Link auffindbar:
www.claypaky.com
Ref: FIS00T - Safety Information Axcor 400 series
INFORMACIONES DE SEGURIDAD
IMPORTANTE: Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este
producto. Además, está disponible una versión digital de la misma en el siguiente enlace:
www.claypaky.com
Ref: FIS00T - Safety Information Axcor 400 series
FR
RU
CONSIGNES DE SÉCURITÉ
IMPORTANT: Claypaky recommande de lire attentivement et de conserver les informations de sécurité relatives à
ce produit, disponibles en version digitale au lien suivant:
www.claypaky.com
Réf. : FIS00T - Safety Information Axcor 400 series
ИНСТРУКЦИЮ ПО ТЕХНИКЕ БЕЗОПАСНОСТИ
ВАЖНО: Claypaky рекомендует внимательно прочитать и сохранить инструкцию по технике безопасности
данного изделия, которая всегда доступна в электронном формате по следующей ссылке:
www.claypaky.com
Наименование: FIS00T - Safety Information Axcor 400 series
AXCOR SPOT 400 - 400 HC
2
1
9
0
°
9
0
°
9
0
°
9
0
°
LOCKED
UNLOCKED
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
LOCKED
UNLOCKED
2. UNPACKING AND PREPARATION
2 x 183102/805
Packing contents - Fig. 1
23
PAN Mechanism Lock and Release (every 90°) - Fig. 2
TILT Mechanism Lock and Release (every 45°) - Fig. 3
AXCOR SPOT 400 - 400 HC
3
4
2
1
1
2
3
3. INSTALLATION AND START-UP
.1 Installing the fixture
3
Installing the projector - Fig. 4
The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall.
WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/001 available on request).
This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base.
3.2 Connecting to manis supply
5
Connecting and disconnecting power cable - Fig. 5
AXCOR SPOT 400 - 400 HC
4
1
Dmx Address
War ning Message
S
IGNAL
S
CREEN
DMX 512
5 PIN
1
2
3
4
5
SIGNAL
6
Mains
Connecting to the mains supply - Fig. 6
3.3 Connecting the control signal line: DMX / Art-Net
7
Connecting to the control signal line (DMX) - Fig. 7
Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 5 pin male/female
connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.
IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the
shield braid and to pin 1 of the connectors.
3.4 Switching on the fixture and basic SetUp
8
Switching on the projector - Fig. 8
Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:
Model Firmware Dmx Address xxx System errors
Axcor Version X.X.X .........................
400 Date - Hour .........................
On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control panel
(Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions:
rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address.
During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the
AXCOR SPOT 400 - 400 HC
5
key will be cancelled.
F
Continue
➔
28
28
9
Reversal of the display - Fig. 9
To activate this function, press UP
maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again.
etting the projector starting address
S
On each projector, the starting address must be set for the control signal (addresses from 1 to 512).
The address can also be set with the projector switched off.
Functions of the buttons - Using the menu
and DOWN Ckeys simultaneously while the display is in the rest mode. This status will be memorised and
B
Confirms the displayed value, or activates the displayed function, or enters the successive
F
C
DOWN
B
D
LEFT
E
RIGHT
USING THE MENU:
1) Press LEFT
2) Use the UP
• Setup (Setup Menu): To set the setting options.
• Option (Option Menu): To set the operating options
• Informations (Informations Menu): To read the counters, software version and other information.
• Manual Control (Manual control Menu): To trigger the test and manual control functions.
• Test (Test Menu): To check the proper functionning of effects
• Advanced (Advanced Menu): Access to the "Advanced menu" is recommended for a trained technical personnel.
3) Press
4) Use the UP
F
once – “Main Menu” appears on the display.
D
and DOWN Ckeys to select the menu to be used:
B
to display the first item in the selected menu.
and DOWN Ckeys to select the MENU items.
B
menu.
Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.
Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.
UP
Return to the top level
Commute from units, tens, hundreds, in the "Address" and "Calibration" menù.
Setting addresses and options with the projector disconnected
The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply.
All that is needed is to press
carried out, the display will switch off again after a wait time of 30 seconds.
AXCOR SPOT 400 - 400 HC
RIGHT Eto momentarily activate the display and thus access the settings. Once the required operations have been
6
1/4 Turn
2
1
/4 Turn
1
2
1
4
3
4. MAINTENANCE
.1 Opening the covers
4
1011
Locking and releasing Pan and Tilt movements - Refer to the instructions in the UNPACKING AND PREPARATION section.
Opening the head covers - Fig. 10.
Closing the head covers - Fig. 11.
AXCOR SPOT 400 - 400 HC
7
Continue
➔
Lower side
U
pper side
12
NOTE: keep a careful cleaning
f the ''CMY/colour filters assembly''
o
to prevent rapid deterioration.
Light collimation system
This product contains internal light
collimation system. Avoid intense
light from any angle.
.2 Periodical cleaning
4
.
g
n
i
n
a
e
l
c
t
n
e
u
q
e
r
f
g
n
i
r
i
u
q
e
r
s
t
r
a
P
Periodical cleaning - Fig. 12
To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The
frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the
working environment (air humidity, presence of dust, salinity, etc.).
Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors, from the lenses and filters. It is recommended
that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations:
• General cleaning of internal parts.
• Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Claypaky.
• General visual check of the internal components, cabling, mechanical parts, etc.
• Electrical, photometric and functional checks; eventual repairs.
AXCOR SPOT 400 - 400 HC
8
1
2
U
pper side
13
.3 Effects module removal
4
Extraction of the effect modules - Fig. 13.
IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged.
Insertion of the effect modules: Repeat the operations indicated in Fig. 13 and 14 in reverse order.
NOTE:
- Do not disconnect wiring harnesses when the fixtures is switched-on, to avoid to damage electronic boards.
- Do not switch-on the fixtures with wiring harness disconnected.
AXCOR SPOT 400 - 400 HC
9
Continue
➔
U
pper side
2
1
1
4
Extraction of the effect modules - Fig. 14.
IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged.
Insertion of the effect modules: Repeat the operations indicated in Fig. 13 and 14 in reverse order.
NOTE:
- Do not disconnect wiring harnesses when the fixtures is switched-on, to avoid to damage electronic boards.
- Do not switch-on the fixtures with wiring harness disconnected.
AXCOR SPOT 400 - 400 HC
10
2
1
1/4 Turn
3
4
3
16
.4 - Cleaning of the filters
4
Cleaning of the filters - Fig. 16.
AXCOR SPOT 400 - 400 HC
11
1
1/4 Turn
2
5
4
5
4
3
5
4
1
7
Cleaning of the filters - Fig. 17.
AXCOR SPOT 400 - 400 HC
12
1
3
2
1.1
ø22.9
Immagine ø17.5
18
.5 - Rotating gobos
4
Bearing group replacement - Fig. 18
19
Replacing rotating gobos - Fig. 19
- Before use custom gobos contact Claypaky;
- The original gobos have a special coating designed specifically to resist to the high temperatures;
- The rotating gobo wheel only use dichroic glass gobos (it is not possible to use metal gobos);
- For more information contact Claypaky;
AXCOR SPOT 400 - 400 HC
13
1
2
3
20
.6 Battery removal
4
Battery removal - Fig. 20
This product contains a rechargeable battery. To preserve the environment, please dispose the battery at the end of its life according to the
regulation in force.
AXCOR SPOT 400 - 400 HC
14
647
(25.47")
276
(10.83")
350
(13.78")
376
(14.80")
470
(18.50")
490
(19.29")
531
(20.90")
5. SPECIFICATIONS
SOURCE
300W White LED Module
VERSION AVAILABLE
CRI 70 (standard version) - CT 6500 - Life 20000hrs
CRI 90 (HC version) - CT 5600 - Life 20000hrs
GENERAL INFO
125mm Frontal lens
One Color Wheel
CMY + Linear CTO based on flag
Rot Gobo Wheel with 7 Gobos 18mm image
Animation wheel
Rotating 4-facet Prism
Iris and Frost filter
Electronic Dimmer
Electronic strobe @25 f/sec.
THE PROJECTOR WILL NOT SWITCH ON
ELECTRONICS NON-OPERATIONAL
DEFECTIVE PROJECTION
REDUCED LUMINOSITY
POSSIBLE CAUSESCHECKS AND REMEDIES
No mains supply.
LED engine defective.
Signal transmission cable faulty or disconnected.
Incorrect addressing.
Fault in the electronic circuits.
Lenses broken
Dust or grease deposited.
AXCOR SPOT 400 - 400 HC
CAUSE AND SOLUTION OF PROBLEMS
Check the power supply voltage.
Replace LED engine.
Replace the cables.
Check addresses (see instructions).
Call an authorised technician.
Call an authorised technician.
Clean (see instructions).