Congratulations on choosing a Clay Paky product!
We thank you for your custom.
Please note that this product, as all the others in the rich Clay
Paky range, has been designed and made with total quality to
ensure excellent performance and best meet your expectations
and requirements.
1
Page 2
SAFETY INFORMATION
EN
IT
DE
ES
SAFETY INSTRUCTIONS
IMPORTANT: Clay Paky recommends you carefully read and keep the safety information on this product, also
available in digital format at the following link:
http://www.claypaky.it/en
Ref: [FIS00L – Safety Information Scenius]
INFORMAZIONI DI SICUREZZA
IMPORTANTE: Clay Paky raccomanda di leggere accuratamente e conservare le informazioni di sicurezza relative
a questo prodotto, sempre reperibili in versione digitale al seguente link:
http://www.claypaky.it/en/download
Rif: [FIS00L – Safety Information Scenius]
NFORMATIONEN ZUR SICHERHEIT
I
WICHTIG: Clay Paky empfiehlt, die Sicherheitsinformationen bezüglich dieses Produkts genau zu lesen und
aufzubewahren. Sie sind in Digitalversion immer unter folgendem Link auffindbar:
http://www.claypaky.it/en/download
Ref: [FIS00L – Safety Information Scenius]
INFORMACIONES DE SEGURIDAD
IMPORTANTE: Clay Paky recomienda leer detenidamente y conservar la información de seguridad relativa a este
producto. Además, está disponible una versión digital de la misma en el siguiente enlace:
http://www.claypaky.it/en/download
Ref: [FIS00L – Safety Information Scenius]
FR
RU
CONSIGNES DE SÉCURITÉ
IMPORTANT: Clay Paky recommande de lire attentivement et de conserver les informations de sécurité relatives
à ce produit, disponibles en version digitale au lien suivant:
http://www.claypaky.it/en/download
Réf. : [FIS00L – Safety Information Scenius]
ИНСТРУКЦИЮ ПО ТЕХНИКЕ БЕЗОПАСНОСТИ
ВАЖНО: Clay Paky рекомендует внимательно прочитать и сохранить инструкцию по технике безопасности
данного изделия, которая всегда доступна в электронном формате по следующей ссылке:
http://www.claypaky.it/en/download
Наименование: [FIS00L – Safety Information Scenius]
SCENIUS PROFILE
2
Page 3
1
9
0
°
9
0
°
9
0
°
9
0
°
LOCKED
UNLOCKED
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
UNLOCKED
LOCKED
UNPACKING AND PREPARATION
2 x 183102/805
LAM00D
(fitted into fixture)
Packing contents - Fig. 1
23
PAN Mechanism Lock and Release (every 90°) - Fig. 2
TILT Mechanism Lock and Release (every 45°) - Fig. 3
SCENIUS PROFILE
3
Page 4
4
2
1
1
2
3
INSTALLATION AND START-UP
Installing the projector - Fig. 4
The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall.
WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/003 available on request).
This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base.
5
Connecting and disconnecting power cable - Fig. 5
SCENIUS PROFILE
4
Page 5
CONTROL PANEL
1
2
Dmx Address
Warning Message
Fixture ID
SIGNAL
SCREEN
DMX 512
5 PIN
1
2
3
4
5
SIGNAL
6
onnecting to the mains supply - Fig. 6
C
Mains
7
Connecting to the control signal line (DMX) - Fig. 7
Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 5-pin male/female
connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.
IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the
shield braid and to pin 1 of the connectors.
8
Switching on the projector - Fig. 8
Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:
Model Firmware xxx (Fixture ID) System errors
SCENIUS Version X.X.X Dmx Address xxx E: .........................
Date - Hour W: .........................
On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control
panel (Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two
conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address
(if set).
During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the
SCENIUS PROFILE
5
key will be cancelled.
F
Continue
➔
Page 6
28
28
9
Reversal of the display - Fig. 9
To activate this function, press UP
maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again.
Setting the projector starting address
On each projector, the starting address must be set for the control signal (addresses from 1 to 512).
The address can also be set with the projector switched off.
Setting the projector Fixture ID
On each projector, the Fixture ID address must be set for an easy identification of the fixtures in an installation (ID from 1 to 255).
The Fixture ID address can be set with the projector switched off.
and DOWN Ckeys simultaneously while the display is in the rest mode. This status will be memorised and
B
Functions of the buttons - Using the menu
F
C
DOWN
B
D
LEFT
E
RIGHT
USING THE MENU:
1) Press
2) Use the UP
• Setup (Setup Menu): To set the setting options.
• Option (Option Menu): To set the operating options
• Informations (Informations Menu): To read the counters, software version and other information.
• Manual Control (Manual control Menu): To trigger the test and manual control functions.
• Test (Test Menu): To check the proper functionning of effects
• Advanced (Advanced Menu): Access to the "Advanced menu" is recommended for a trained technical personnel.
To enable the "Advanced" see pag.16.
3) Press
4) Use the UP
once – “Main Menu” appears on the display.
F
and DOWN Ckeys to select the menu to be used:
B
to display the first item in the selected menu.
F
and DOWN Ckeys to select the MENU items.
B
Confirms the displayed value, or activates the displayed function, or enters the successive
menu.
Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.
Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.
UP
Return to the top level
Commute from units, tens, hundreds, in the "Address", "Fixture ID" and "Calibration" menù.
Setting addresses and options with the projector disconnected
The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply.
All that is needed is to press
the display will switch off again after a wait time of 30 seconds.
SCENIUS PROFILE
to momentarily activate the display and thus access the settings. Once the required operations have been carried out,
F
6
Page 7
1/4 Turn
1/4 Turn
1
2
1
2
1/4 Turn
2
1
CLICK!!
MAINTENANCE
1011
Locking and releasing Pan and Tilt movements - Refer to the instructions in the UNPACKING AND PREPARATION section.
Opening the head covers - Fig. 10.
Closing the head covers - Fig. 11.
SCENIUS PROFILE
7
Continue
➔
Page 8
Upper Side
Upper Side
1
2
Periodical cleaning - Fig. 12
To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The
frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the
working environment (air humidity, presence of dust, salinity, etc.).
Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors, from the lenses and filters. It is recommended
that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations:
• General cleaning of internal parts.
• Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Clay Paky.
• General visual check of the internal components, cabling, mechanical parts, etc.
• Electrical, photometric and functional checks; eventual repairs.
NOTE: keep a careful cleaning of the ''CMY/colour filters assembly'' to prevent rapid deterioration.
SCENIUS PROFILE
8
Page 9
1
4
3
2
1
3
Cleaning of the filters - Fig. 13.
SCENIUS PROFILE
Continue
9
➔
Page 10
1
2
1
2
1
2
Upper Side
Lower Side
Upper Side
4
1
Extraction of the effect modules: Preliminary operations - Fig. 14.
SCENIUS PROFILE
10
Page 11
2
3
4
1
Upper Side
1
5
Extraction of the effect modules: Preliminary operations - Fig. 15.
SCENIUS PROFILE
11
Continue
➔
Page 12
1
2
Upper Side
1
6
Extraction of the effect modules - Fig. 16.
IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged.
Insertion of the effect modules: Repeat the operations indicated in Fig. 14, 15, 16, 17 and 18 in reverse order.
SCENIUS PROFILE
12
Page 13
1
2
Upper Side
1
7
Extraction of the effect modules - Fig. 17.
IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged.
Insertion of the effect modules: Repeat the operations indicated in Fig. 14, 15, 16, 17 and 18 in reverse order.
SCENIUS PROFILE
13
Continue
➔
Page 14
Upper Side
1
Lower Side
Lower Side
3
2
1
8
Extraction of the effect modules - Fig. 18.
IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged.
Insertion of the effect modules: Repeat the operations indicated in Fig. 14, 15, 16, 17 and 18 in reverse order.
SCENIUS PROFILE
14
Page 15
Upper Side
Lower Side
2
A
1
A
3
A
Upper Side
Lower Side
2
1
1
HOT SPOT
9
2
0
Opening and closing lamp compartment - Fig. 19
21
Lamp change - Fig 20
Take the new lamp out of its package and insert in the fitting.
WARNING: do not touch the lamp’s envelope with bare hands.
Should this happen, clean the bulb with a cloth soaked in alcohol
and dry it with a clean, dry cloth.
CAUTION: Fast lamp ON-OFF cycles (for example 10 minutes ON /
10 minutes OFF) will reduce the lamp life.
Lamp regulation - Fig. 21
To centre the lamp, turn the three adjusting screws as shown in the figure.
SCENIUS PROFILE
15
Continue
➔
Page 16
1
2
GOBO ROTATION
GOD00E/001
GOD00E/002
GOD00E/013
GOD00E/014
GOD00E/005
GOD00E/010
INDEX
22
Bearing group replacement - Fig. 22
23
Replacing rotating gobos (ø 32.8 mm - max 23 mm image – thickness 1.1 mm) - Fig. 23
- Before use custom gobos contact Clay Paky;
- The original gobos have a special coating designed specifically to resist to the high temperatures;
- The rotating gobo wheel only use dichroic glass gobos (it is not possible to use metal gobos);
- For more information contact Clay Paky;
SCENIUS PROFILE
16
Page 17
GOD00F/001
GOD00F/002
GOD00F/003
GOD00F/004GOD00F/005
GOD00F/006
GOD00F/007
GOD00F/009
2
1
24
Replacing fixed gobos (ø 31.5 mm - max 23 mm image - thickness 1.1 mm) - Fig. 24
IMPORTANT: Please contact CLAY PAKY before using customized gobos.
SCENIUS PROFILE
17
Continue
➔
Page 18
9
1
2
5
3
4
6
7
8
25
Battery removal - Fig. 25
This product contains a rechargeable lithium iron tetraphosphate battery. To preserve the environment, please dispose the battery at the end
of its life according to the regulation in force.
LiFePO4
SCENIUS PROFILE
18
Page 19
TECHNICAL INFORMATION
410
(16.14")
360
(14.17")
486
(19.13")
760
(29.92")
565
(22.24")
584
(22.99")
645
(25.39")
Power supplies
200/240V 50/60 Hz
Light source
Lamp OSRAM Lok-it 1400-PS
• Color Temperature: 6.000 K
• Life: 750 hrs
• Very high CRI
• Luminoux flux: 120000 lm
• Base PGJ28 Lok-it!
Motors:
28 stepper motors, operating with microsteps,
totally microprocessor controlled.
Channels:
37 control channels – 41 Vector
Inputs:
• DMX 512
• Ethernet
Moving body
Automatic repositioning of PAN and TILT after
accidental movement not controlled by control unit.