Clay Paky ALPHA SPOT HPE 1500 Instruction Manual

Page 1
1
C61325
®
1
INSTRUCTION MANUAL
INDEX
Carefully read this instruction manual in its entirety and keep it safe for future reference. It is essential to know the information and comply with the instructions given in this manual to ensure the fitting is installed, used and serviced correctly and safely. CLAY PAKY S.p.A. disclaims all liability for damage to the fitting or to other property or persons deriving from installation, use and maintenance that have not been carried out in conformity with this instruction manual, which must always accompany the fitting. CLAY PAKY S.p.A. reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice.
PRE
LIM
INAR
Y
ENGLISH
ALPHA SPOT HPE 1500
Pag.
2
3
4
5
7
14
22
22
23
Contents
Safety information
Unpacking and preparation
Installation and start-up
Control panel
Menu setting
Maintenance
Technical information
Cause and solution of problems
Channel functions
Page 2
2
ALPHA SPOT HPE 1500
• Installation
Make sure all parts for fixing the projector are in a good state of repair. M
ake sure the point of anchorage is stable before positioning the projector. The safety chain must be properly hooked onto the fitting and secured to the framework, so that, if the primary support system fails, the fitting falls as little as possible. If the safety chain gets used, it needs to be replaced with a genuine spare.
• Minimum distance of illuminated objects
The projector needs to be positioned so that the objects hit by the beam of light are at least 5 metres (16'5'') from the lens of the projector.
Minimum distance from flammable materials
The projector must be positioned so that any flammable materials are at least 0.20 metres (8") from every point on the surface of the fitting.
• Mounting surfaces
It is permissible to mount the fitting on normally flammable surfaces.
• Maximum ambient temperature
Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
• IP20 protection rating
The fitting is protected against penetration by solid bodies of over 12mm (0.47”) in diameter (first digit 2), but not against dripping water, rain, splashes or jets of water (second digit 0).
• Protection against electrical shock
Connection must be made to a power supply system fitted with efficient earthing (Class I appliance according to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the projectors from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
• Connection to mains supply
Connection to the electricity mains must be carried out by a qualified electrical installer. Check that the mains frequency and voltage correspond to those for which the projector is designed as given on the electrical data label. This label also gives the input power to which you need to refer to evaluate the maximum number of fittings to connect to the electricity line, in order to avoid overloading.
• Temperature of the external surface
The maximum temperature that can be reached on the external surface of the fitting, in a thermally steady state, is 150°C (302°F).
• Maintenance
Before starting any maintenance work or cleaning the projector, cut off power from the mains supply. After switching off, do not remove any parts of the fitting for at least 10 minutes. After this time the likelihood of the lamp exploding is virtually nill. If it is necessary to replace the lamp, wait for another 20 minutes to avoid getting burnt. The fitting is designed to hold in any splinters produced by a lamp exploding. The lenses must be mounted and, if visibly damaged, they have to be replaced with genuine spares.
• Lamp
The fitting mounts a high-pressure lamp that needs an external igniter. This igniter is fitted onto the apparatus.
- Carefully read the "operating instructions" provided by the lamp manufacturer.
- Immediately replace the lamp if damaged or deformed by heat.
• Battery
This product contains a rechargeable lead-acid battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force. Instructions on how to remove the battery from the product are available on www.claypaky.it
SAFETY INFORMATION
The products referred to in this manual conform to the European Community Directives to which they are subject:
Low Voltage 2006/95/CE
Electromagnetic Compatibility 2004/108/CE
5
1500W
IP20
Pb
Page 3
3
ALPHA SPOT HPE 1500
UNPACKING AND PREPARATION
Lamp 1500W
(fitted into projector)
099105
2 x 183102/802
1
90°
9
9
90
°
LOCKED
UNLOCKED
PAN Mechanism Lock and Release (every 90°) - Fig. 2
TILT Mechanism Lock and Release (every 45°) - Fig. 3
2
4
4
5
°
4
4
5
°
45°
4
UNLOCKED
LOCKED
3
Packing contents - Fig. 1
Page 4
4
ALPHA SPOT HPE 1500
INSTALLATION AND START-UP
4
1
2
1
2
3
5
Connecting and disconnecting power cable - Fig. 5
Installing the projector - Fig. 4
The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall.
WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/003 available on request). This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base.
Page 5
5
ALPHA SPOT HPE 1500
CONTROL PANEL
Continue
Switching on the projector - Fig. 8 Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:
Model Firmware xxx (Fixture ID) System errors
Alpha SPOT HPE Version X.X.X Dmx Address xxx E: .........................
1500 Date - Hour W: .........................
On conclusion of resetting in case of absence of dmx signal, Pan and Tilt move to the “Home” position (Pan 50% - Tilt 50%). The control panel (Fig.
8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address (if set). During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status. It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the
F
key will be cancelled.
1
2
Dmx Address
Warning Message
Fixture ID
M
AINS
8
Connecting to the control signal line (DMX) - Fig. 7 Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 3 or 5-pin male/female connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3. IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the shield braid and to pin 1 of the connectors.
L
N
6
7
SIGNAL
SCREEN
DMX 512
5 PIN
1
2
3
4
5
SIGNAL
SCREEN
1
3
2
DMX 512
3 PIN
SIGNAL
SIGNAL
DMX 512
C
onnecting to the mains supply - Fig. 6
Mains
Page 6
6
ALPHA SPOT HPE 1500
28
28
Reversal of the display - Fig. 9 To activate this function, press UP
B
and DOWN Ckeys simultaneously while the display is in the rest mode. This status will be memorised and
maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again.
Setting the projector starting address
On each projector, the starting address must be set for the control signal (addresses from 1 to 512). The address can also be set with the projector switched off. Setting the address: see pag. 8.
Setting the projector Fixture ID
On each projector, the Fixture ID address must be set for an easy identification of the fixtures in an installation (ID from 1 to 255). The Fixture ID address can be set with the projector switched off. Setting the Fixture ID: see pag. 8.
9
Functions of the buttons - Using the menu
Setting addresses and options with the projector disconnected
The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply. All that is needed is to press
F
to momentarily activate the display and thus access the settings. Once the required operations have been carried out,
the display will switch off again after a wait time of 30 seconds.
USING THE MENU:
1) Press
F
once – “Main Menu” appears on the display.
2) Use the UP
B
and DOWN Ckeys to select the menu to be used:
• Setup (Setup Menu): To set the setting options.
• Option (Option Menu): To set the operating options
• Informations (Informations Menu): To read the counters, software version and other information.
• Manual Control (Manual control Menu): To trigger the test and manual control functions.
• Test (Test Menu): To check the proper functionning of effects
• Advanced (Advanced Menu): Access to the "Advanced menu" is recommended for a trained technical personnel. To enable the "Advanced" see pag.13
3) Press
F
to display the first item in the selected menu.
4) Use the UP
B
and DOWN Ckeys to select the MENU items.
Confirms the displayed value, or activates the displayed function, or enters the successive menu.
Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.
Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.
Return to the top level
Commute from units, tens, hundreds, in the "Address", "Fixture ID" and "Calibration" menù.
F
C
DOWN
B
UP
D
LEFT
E
RIGHT
Page 7
7
ALPHA SPOT HPE 1500
S
ystem
E
rrors
Information
Fixture
H
ours
L
amp
Hours
4
Lamp
Manual Control
Reset
Channel
65
MAIN MENU
MENU SETTING
Set Up
D
mx
A
ddress
Channel
M
ode
E
thernet
F
ixture ID
Option
I
nformation
M
anual
C
ontrol
T
est
Advanced
13
L
amp
S
trikes
System V
ersion
Board
Diagnost.
D
mx
Monitor
F
ans
M
onitor
Access code
1234
Advanced
Calibration
Upload
Firmware
Setup Model
Pan / Tilt
Colour
Beam
Gobo
All
T
est
Continue
2
Lamp Dmx
P
an / Tilt
Color
Display
Option
Invert
P
an
I
nvert
T
ilt
S
wap
P
an-Tilt
E
ncoder
Pan-Tilt
C
olor
Mixing
Fixed Wheel
Shortcut
Setting
Default
Preset
User
Preset 1
User
Preset 2
User
Preset 3
S
hutter
Shutter
O
n Error
D
immer On
Shutter
Power Mode
1500-1200
F
ull fan speed
1200
Low fan speed
1500-1200
Auto fan speed
Page 8
8
ALPHA SPOT HPE 1500
DMX ADDRESS NOTE: without the DMX signal the Address (XXX) flashing
Allows you to select the DMX ADDRESS
1) Press
F
- the current DMX Adress appear on the display.
2) Use the UP
B
, DOWN C, RIGHT Ekeys to plan the DMX
Address.
3) Press
F
to confirm the selection or LEFT Dto keep current settings.
CHANNEL MODE
Allows you to select a channel arrangement from the two available.
1) Press
F
- the current settings appear on the display (Standard or
Vector).
2) Use the UP
B
and DOWN Ckeys to select one of the following
settings:
- Standard
- Vector
3) Press
F
to confirm the selection or LEFT Dto keep current settings.
ETHERNET
Work in progress
FIXTURE ID
Allows you to select the FIXTURE ID
1) Press
F
- the current Fixture ID appear on the display.
2) Use the UP
B
, DOWN C, RIGHT Ekeys to plan the Fixture ID.
3) Press
F
to confirm the selection or LEFT Dto keep current settings.
NOTE: On grey the default options
LAMP DMX
Used for enabling lamp remote control channel.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys to enable (On) or disable (Off)
the lamp remote control channel.
3) Press
F
to confirm the selection or LEFT Dto keep current settings.
PAN / TILT Invert pan
Used for reversing Pan movement.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys to enable (On) or disable (Off)
PAN inversion.
3) Press
F
to confirm the selection or LEFT Dto keep current settings.
Invert tilt
Used for reversing tilt movement.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys to enable (On) or disable (Off)
Tilt inversion.
3) Press
F
to confirm the selection or LEFT Dto keep current settings.
SET UP MENU
OPTIONS MENU
S
et Up
D
mx
Address
C
hannel
Mode
E
thernet
Fixture Id
A
ddress xxx
S
tandard
V
ector
Value xxx
Lamp Dmx
Pan / Tilt
Option
On
Off
Invert
Pan
On
Off
Invert
Tilt
On
Off
Page 9
9
ALPHA SPOT HPE 1500
Continue
Swap Pan-Tilt
Used for swapping Pan and Tilt channels (as well as Pan fine and Tilt fine).
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys to enable (On) or disable (Off)
Pan and Tilt channel swap.
3) Press
F
to confirm the selection or LEFT Dtto keep current settings.
Encoder Pan-Tilt
Used for enabling the Pan / Tilt encoders.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys to enable (On) or disable (Off)
Pan / Tilt encoders.
3) Press
F
to confirm the selection or LEFT Dto keep current settings.
COLOR Color mixing
Used for reversing the CMY color mixing system.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys select one of the following settings: RGB color mixing mode CMY color mixing mode
3) Press
F
to confirm the selection or LEFT Dto keep current settings.
Fixed wheel short-cut
Used for optimizing color change time so that the disc turns in the direc­tion that requires shorter movement.
1) Press
F
– the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys to enable (On) or disable (Off)
color change optimization.
3) Press
F
to confirm the selection, or LEFT Dto keep current settings.
SHUTTER Shutter on error
Used for automatically closing the stop/strobe in the event of Pan/Tilt position error.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys to enable (On) or disable (Off)
automatic stop/strobe closing in the event of Pan/Tilt position error.
3) Press
F
to confirm the selection, or LEFT Dto keep current settings.
Dimmer on Shutter
Enables automatic closing of the dimmer when the strobe is completely closed.
1) PressF– the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys to enable (On) or disable (Off)
the automatic closing of the dimmer.
3) Press
F
to confirm the selection or LEFT Dto keep current settings.
POWER MODE
Allows you to select a Power Mode from the three available.
1) Press
F
- the current settings appear on the display.
2) Use the UP
B
and DOWNCkeys to select one of the following settings:
- 1500-1200W Full fan speed: Lamp can change from full-power
(1500W) to half-power (1200W) using the LAMP CONTROL channel. Fans always work at Full speed
- 1200W Low fan speed: Lamp constantly works in half-power mode
(1200W) while the Fan always works at Low speed. With LAMP CONTROL channel you can only switch the lamp ON and OFF.
- 1500-1200W Auto fan speed: Lamp can change from full-power
(1500W) to half-power (1200W) using the LAMP CONTROL channel. Automatically the fans switch from Full speed to Low speed respectively.
3) Press
F
to confirm the selection or LEFT Dto keep current setting.
C
olor
S
wap
P
an-Tilt
O
n
O
ff
Encoder
Pan-Tilt
On
O
ff
Color
Mixing
R
gb
Cmy
Fixwheel
S
hortcut
O
n
O
ff
Shutter
Shutter
On Error
On
Off
Dimmer On
Shutter
On
Off
Power Mode
1500-1200
Full fan speed
1200
Low fan speed
1500-1200
Auto fan speed
Page 10
10
ALPHA SPOT HPE 1500
DISPLAY
Used for automatically reduce brightness on the display after about 30 seconds in idle.
1) Press
F
- the current settings appear on the display (On or Off).
2) Use the UP
B
and DOWN Ckeys to enable (On) or disable (Off)
the decreasing of display brightness.
3) Press
F
to confirm the selection or LEFT Dto keep current
settings.
S
ETTING
U
sed to save 3 different settings of the items in the options menu and
relative submenus.
1) Press
F
- “Default preset” appears on the display.
2) Use the UP
B
and DOWN Ckeys to select one of the following
configurations:
- Default preset (*)
-
User preset 1
- User preset 2
- User Preset 3
3) Press
F
- “Load preset X” appears on the display.
4) Use the UP
B
and DOWN Ckeys to select:
- Load preset X to recall a previously stored configuration.
- Save to preset X to store the current configuration. a confirmation message (Are you sure?) appears on the display.
5) Select YES to confirm the selection or NO to keep the current setting and return to the next higher level.
(*) DEFAULT PRESET Used for restoring default values on all options menu items and relevant submenus.
1) Press
F
, a confirmation message (Are you sure?) appears on the
display .
2) Select YES to confirm the selction or NO to keep current setting.
OPTION DEFAULT Lamp DMX On Invert Pan Off Invert Tilt Off Swap Pan-Tilt Off Encoder Pan-Tilt On Colour mixing CMY Fixed Wheel Shortcut On Shutter on error Off Dimmer on Shutter Off Display On
SYSTEM ERRORS
Shows a list of warnings and messages relevant to errors occurred since the fixtures switching-on.
1) Pressing
F
you are allowed to reset the SYSTEM ERRORS list. A confirmation message (Are you sure you want to clear error list ?) appears on the display.
2) Select YES to reset the list or NO to go back.
FIXTURE HOURS
Used for displaying projector operating hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working life hours (from manufacture to date).
Partial counter
Counts the number of partial projector working life hours since the last reset to date.
2) Press
F
to reset partial projector working hours a confirmation
message (Are you sure?) appears on the display.
Information
INFORMATION MENU
Reset To
D
afault
G
o Back
S
etting
Default
Preset
Load
Preset 1
S
ave To
P
reset 1
User
Preset 1
Load
Preset 2
S
ave To
P
reset 2
User
Preset 2
Load
P
reset 3
Save To Preset 3
User
Preset 3
System
Errors
Fixture
Hours
Total XXX Partial XXX
Reset...
On
O
ff
D
isplay
Page 11
11
ALPHA SPOT HPE 1500
Continue
L
amp
H
ours
T
otal XXX
P
artial XXX
Reset...
3) Select YES to reset partial projectors counter or NO to keep the current setting and return to the top menu level.
LAMP HOURS
Used for displaying the lamp working hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working hours with the lamp on (from manufacture to date).
Partial counter
C
ounts the number of lamp working hours since the last reset to date.
2) Press
F
to reset partial lamp working hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting and return to the top menu level
L
AMP STRIKES
Used for displaying the number of times the lamp was turned on (total and p
artial).
1) Press
F
- the number of times the lamp was turned on (total and
partial) appears on the display.
Total counter
Counts the number of times the lamp was turned on (from manufacture to date).
Partial counter
Counts the number of times the lamp was turned on since the last reset to date.
2) Press
F
to reset partial lamp strikes hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting and return to the top menu level
SISTEM VERSION
Used for displaying the software and hardware version of each board installed in the projector. CPU brd (CPU board) 0: PT-3f (Pan / Tilt board) 1: 8-Ch (8 channel board) 2: 8-Ch (8 channel board) 3: 8-Ch (8 channel board)
BOARD DIAGNOSTIC
Used for displaying the status error of each board installed in the projector: 0: PT-3f (Pan / Tilt board) 1: 8-Ch (8 channel board) 2: 8-Ch (8 channel board) 3: 8-Ch (8 channel board)
DMX MONITOR
Used for displaying the projector DMX channel level in bit (Val) and in percentage (Perc).
System Version
Board Revis. Hw.rv. CPU brd x.x.x x.x com.dev x.x 0: PT-3f x.x x.x 1: 8-Ch x.x x.x 2: 8-Ch x.x x.x
Board
Diagnost.
Dmx
Monitor
Board Status Err% 0:PT-3f Good 0.00 1:8-Ch Good 0.00 2:8-Ch Good 0.00
Val Perc Cyan XXX X% Magenta XXX X% Yellow XXX X% Color W. XXX X% Strobe XXX X% Dimmer XXX X% Dimm.fine XXX X% Iris XXX X% Fix Gobo C. XXX X% Rot. Gobo C. XXX X% Gobo Rot. XXX X% Prism C. XXX X% Prism Rot. XXX X% L. Frost XXX X% M. Frost XXX X% H. Frost XXX X% Focus XXX X% Pan XXX X% Pan Fine XXX X% Tilt XXX X% Tilt Fine XXX X% Function XXX X% Reset XXX X% Lamp On/Off XXX X%
L
amp
S
trikes
T
otal XXX
P
artial XXX
Reset...
Page 12
12
ALPHA SPOT HPE 1500
LAMP
Used for turning lamp on and off from the projector control panel.
1) Pres
s F-
the current settings appear on the display (On or Off).
2) Use the
UP Band DOWN Ckeys to turn the lamp on (On) or off (Off)
3) Press
F
to confirm the selection or
LEFT Dto keep current settings
and return to the top level.
RESET
Used for resetting the projector.
1) Press
F
to reset the projectors, a confirmation message (Are you sure ?)
appears on the display.
2) Select YES to starting reset the fixture or NO to keep the current setting and return to the top menu level.
CHANNEL
Used for setting channel levels from the projector control panel.
1) Press
F
- the first channel appears on the display.
2) Use the UP
B
and DOWN Ckeys to select the required channel:
3) Press
F
and use the UP Band DOWN Ckeys to select the
required DMX level (value between 0 and 255).
4) Press LEFT
D
to return to the top menu level.
AUTOTEST
Allows you to check the proper functioning of effects.
1) Press
F
.
2) Use the UP
B
and DOWN Ckeys to select the required test.
3) Press
F
to confirm the selection or LEFT Dto return to the top
menu level.
Test sequence: Pan - Tilt effects (Pan & Tilt) Colour effects (CMY, colour wheel) Beam effects (Stopper-Strobe / Dimmer / Iris / Prism / Frost) Gobo effects (Fixed gobo / Rotating gobo) All effects
Channel
Cyan xxx xx% Magenta xxx xx% Yellow xxx xx% Colour W. xxx xx% Strobe xxx xx% Dimmer xxx xx% Dimm. fine xxx xx% Iris xxx xx% Fix Gobo C. xxx xx% Rot Gobo C. xxx xx% Gobo rot. xxx xx% Prism C. xxx xx% Prism rot. xxx xx% L. Frost xxx xx% M. Frost xxx xx% H. Frost xxx xx% Focus xxx xx% Pan xxx xx% Pan fine xxx xx% Tilt xxx xx% Tilt fine xxx xx% Function xxx xx% Reset xxx xx% Lamp On / Off xxx xx%
Test
Pan-Tilt Colour Beam Gobo All
TEST MENU
MANUAL CONTROL
Lamp
M
anual
Control
On
O
ff
No
Y
es
Reset
FANS MONITOR
Used for displaying the speed of each fan installed in the projector: Pwr.Sup (Power supply Fan) Ball. IN (Ballast IN Fan) Ball. Out (Ballast OUT Fan) Eff.IN (Effects IN Fan) Eff.OUT (Effects OUT Fan) Iris (Iris Fan) Lamp (Lamp Fan)
F
ans
M
onitor
F
an Speed (RPM) Pwr.Sup XXXX Ball.In. XXXX B
all.Out XXXX E
ff.In XXXX Eff.Out XXXX Iris XXXX L
amp XXXX
Page 13
13
ALPHA SPOT HPE 1500
To enable the "Advanced Menu" set up the "Access code" (1234) using the UP
B
, DOWN C, RIGHT Ekeys.
Press
F
- "Menu advanced" appears on the display
UP LOAD FIRMWARE
Allows you to transfer the firmware from 1 fixture to all the connected fixtures.
1) Press
F
, a confirmation message appears on the display.
2) Select YES to start the firmware loading or NO to keep the current set­ting and return to the top menu level
SETUP MODEL
Allows you to change the default model of projector.
1) Press
F
a confirmation message appears on the display.
2) Select YES to define the model of projector or NO to keep the current s
etting and return to the top menu level.
CALIBRATION
Allows you to adjust effects from the control panel to obtain perfect unifor­mity between the projectors.
1) Press
F
- “channels” appears on the display.
2) Using the UP
B
and DOWN Ckeys, select the effect you wish to
regulate.
3) Press
F
and use the RIGHT E, UPBand DOWN Cbuttons to
make the adjustment by setting a value between 0 and 255.
4) Press
F
to confirm the selection
or
LEFT Dto keep current set-
tings and return to the top level.
FACTORY DEFAULT
Allows you to restore default values of all channels (128).
1) Press
F
– a confirmation message appears on the display (Reset
calibration to factory default ?).
2) Select YES to reset calibration to factory default or NO to keep the current setting and return to the top menu level.
ADVANCED MENU
Advanced
Code
1
234
Calibration
P
an 128
T
ilt 128 Cyan 128 M
agenta 128
Y
ellow 128 Prism Chg 128 Prism Rot. 128 L
ight Frost 128
M
id Frost 128 Heavy Frost 128 D
immer 128 F.Gobo.Chg 128 I
ris 128
R
.Gobo.Chg 128 Gobo Rot. 128 C
olour Wheel 128 Stop/Strobe 128 Focus 128 Factory Default Yes / No
U
pload
F
irmware
Transfer the firmware on all the connected fixtures ? Are you sure ? Y
es/No
S
etup
Model
Changing to a wrong model m
ay damage the fixture.
A
re you sure ?
Yes/No
Page 14
14
ALPHA SPOT HPE 1500
Locking and releasing Pan and Tilt movements - Refer to the instructions in the UNPACKING AND PREPARATION section. Opening the head covers - Fig. 11.
Closing the head covers - Fig. 12.
1/4 Turn
1
3
2
1
2
1/4 Turn
1
4
5
11 12
MAINTENANCE
Page 15
15
ALPHA SPOT HPE 1500
Fan support plate opening and closing (Lower side) - Fig. 16
3
2
1
Lower Side
4
16
1
2
14
15
1
2
13
Lamp change - Fig 14 Take the new lamp out of its package and insert in the fitting.
WARNING: do not touch the lamp’s envelope with bare hands. Should this happen, clean the bulb with a cloth soaked in alcohol and dry it with a clean, dry cloth.
Lamp regulation - Fig. 15 To centre the lamp, turn the three adjusting screws as shown in the figure.
Opening and closing lamp compartment - Fig. 13
Continue
Page 16
16
ALPHA SPOT HPE 1500
Fan support plate opening and closing (Upper side) - Fig. 17
Upper Side
1
2
17
2
1
085911/001
085901/001
085903/001
085907/001
085912/001
085906/001
085904/001
085908/001
Lower Side
18
Replacing fixed gobos (ø 31.5 mm - max 25 mm image - thickness max 1 mm) - Fig. 18
Page 17
17
ALPHA SPOT HPE 1500
1
9
Upper Side
1
2
GOBO ROTATION 1
084632/001
105115/802 084629/001
084628/001
105115/801 084624/001
GOBO INDEX
GOBO ROTATION 2
084633/001
084630/001 084629/001
084627/001
08463/001 084624/001
GOBO INDEX
1
2
20
Replacing rotating gobos (ø 37.4 mm - max 25 mm image – thickness 1 mm) - Fig. 20 IMPORTANT: Use only glass gobos on the rotating gobos wheels. For any further information contact CLAY PAKY.
Bearing group replacement - Fig. 19
Continue
Page 18
18
ALPHA SPOT HPE 1500
Periodical cleaning - Fig. 22 To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the working environment (air humidity, presence of dust, salinity, etc.). Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors, from the lenses and filters. It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations:
General cleaning of internal parts.
Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Clay Paky.
General visual check of the internal components, cabling, mechanical parts, etc.
Electrical, photometric and functional checks; eventual repairs.
Upper Side Lower Side
22
2
1
Gobo orientation - Fig. 21 The pictures shown the correct gobos orientation.
To determine which side of a godo is coated, hold an odject up to it. On the uncoated side, there is a space between the object and its reflection.
COATED GLASS GOBOS TYPE 1 COATED GLASS GOBOS TYPE 2
Grey/Black side away
f
rom lamp
C
oated side
towards lamp
Coated side
Uncoated side
Uncoated side
Reflective side towards lamp
Page 19
19
ALPHA SPOT HPE 1500
Extraction of the effect modules: Preliminary operations - Fig. 23
1
3
4
2
23
Continue
Page 20
20
ALPHA SPOT HPE 1500
6
5
Lower Side
9
8
7
10
Upper Side
11
Upper Side
12
14
13
15
Upper Side
Extraction of the effect modules - Fig. 24 IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged. Insertion of the effect modules: Repeat the operations indicated in Fig. 24 and 25 in reverse order
24
Page 21
21
ALPHA SPOT HPE 1500
16
U
pper Side
17
18
U
pper Side
19
Upper Side
12
14
13
15
Upper Side
Extraction of the effect modules - Fig. 25 IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged. Insertion of the effect modules: Repeat the operations indicated in Fig. 24 and 25 in reverse order
25
Page 22
22
ALPHA SPOT HPE 1500
660
(
25.98")
620
(24.41")
488
(19.21")
835
(32.87")
232
(
9.13")
500
(19.69")
480
(18.90")
Power supplies available
200-240V 50/60Hz
Input power
2000VA a 230V 50Hz.
Lamp
Discharge lamp.
• Type HTI 1500W/60/P50 Lok-it Osram (L10096)
- Cap PGJ50
-
Colour temperature 6000 K
- Luminous flux 135000 lm
- Average life 750 h
- Any working position
• Type MSR Gold 1500 FastFit Philips (L10097)
- Cap PGJ50
- Colour temperature 6000 K
- Luminous flux 120000lm
-
Average life 750h
- Any working position
Motors
29 stepper motors, operating with microsteps, totally microprocessor controlled.
Optical unit
Elliptic reflector with high luminous efficiency
Channels
Max 40 control channels.
Inputs
DMX 512
Movable body
Movement by means of two stepper motors, con­trolled by microprocessor.
Automatic repositioning of PAN and TILT after accidental movement not controlled by control unit.
Travel:
- PAN = 540°
- TILT = 252°
Maximum speeds:
- PAN = 4.0 sec (360°)
- TILT = 3.2 sec (252°)
Resolution:
- PAN = 2.11°
- PAN FINE = 0.008°
- TILT = 0.98°
- TILT FINE = 0.004°
IP20 protection rating
• Protected against the entry of solid bodies larger than 12mm (0.47”).
• No protection against the entry of liquids.
CE Marking
In conformity with the European Union Low Voltage Directive 2006/95/CE and Electromagnetic compa-
tibility Directive 2004/108/CE.
S
afety Devices
• Bipolar circuit breaker with thermal protection.
• Automatic break in power supply in case of overheating or failed operation of cooling system.
Cooling
Forced ventilation with axial fans.
B
ody
• Aluminium structure with die-cast plastic cover.
• Two side handles for transportation.
• Device locking PAN and TILT mechanisms for transportation and maintenance.
Working position
Functioning in any position.
Weights
about 50.95 Kg (112lbs, 1oz).
TECHNICAL INFORMATION
CAUSE AND SOLUTION OF PROBLEMS
THE PROJECTOR WILL NOT SWITCH ON
PROBLEMS
ELECTRONICS NON-OPERATIONAL
DEFECTIVE PROJECTION
REDUCED LUMINOSITY
POSSIBLE CAUSES CHECKS AND REMEDIES
No mains supply. Lamp exhausted or defective. Signal transmission cable faulty or disconnected. Incorrect addressing. Fault in the electronic circuits. Lenses or reflector broken Dust or grease deposited.
Check the power supply voltage. Replace the lamp. (See instructions). Replace the cables. Check addresses (see instructions). Call an authorised technician. Call an authorised technician. Clean (see instructions).
Page 23
23
ALPHA SPOT HPE 1500
ALPHA SPOT HPE 1500
CHANNEL FUNCTION
CHANNEL
S
TANDARD VECTOR
CHANNEL MODE
CYAN M
AGENTA YELLOW C.T.O COLOUR WHEEL MACRO COLOURS STOP/STROBE DIMMER DIMMER FINE IRIS ANIMATED STAR GOBO STATIC GOBO CHANGE ROTATING GOBO 1 CHANGE GOBO 1 ROTATION GOBO 1 FINE ROTATING GOBO2 CHANGE GOBO2 ROTATION GOBO2 FINE ANIMATION DISK INSERTION ANIMATION DISK ROTATION ROTATING PRISM INSERTION PRISM ROTATION FROST INSERTION FOCUS FOCUS FINE ZOOM AUTOFOCUS DISTANCE AUTOFOCUS ADJUSTMENT MACRO EFFECTS PAN PAN FINE TILT TILT FINE FUNCTION RESET LAMP ON/OFF (with Option "Lamp DMX" ON)
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
CYAN M
AGENTA YELLOW C.T.O COLOUR WHEEL MACRO COLOURS STOP/STROBE DIMMER DIMMER FINE IRIS ANIMATED STAR GOBO STATIC GOBO CHANGE ROTATING GOBO 1 CHANGE GOBO 1 ROTATION GOBO 1 FINE ROTATING GOBO2 CHANGE GOBO2 ROTATION GOBO2 FINE ANIMATION DISK INSERTION ANIMATION DISK ROTATION ROTATING PRISM INSERTION PRISM ROTATION FROST INSERTION FOCUS FOCUS FINE ZOOM AUTOFOCUS DISTANCE AUTOFOCUS ADJUSTMENT MACRO EFFECTS PAN PAN FINE TILT TILT FINE FUNCTION RESET LAMP ON/OFF (with Option "Lamp DMX" ON) PAN-TILT TIME COLOUR TIME BEAM TIME GOBO TIME
Continue
Page 24
24
ALPHA SPOT HPE 1500
BIT % EFFECT
255 100
COLOUR EXCLUDED
0 0.0
COLOUR INSERTED
CHANNEL 1
C
YAN
CHANNEL 2
M
AGENTA
CHANNEL 3
Y
ELLOW
B
IT
%
EFFECT
255 100
COLOUR INSERTED
0 0.0
C
OLOUR EXCLUDED
CHANNEL 1
CYAN
CHANNEL 2
MAGENTA
CHANNEL 3
YELLOW
• COLOUR MIXING - channel 1 - 2 - 3
O
peration with option color mixing: RGB
O
peration with option color mixing: CMY
IMPORTANT: The lamp dim to half power 1 second after all the 3 channels stay at 100% level. The lamp goes back to full power when the channels level is put lower than 100%.
I
MPORTANT: The lamp dim to half power 1 second after all the 3 channels stay at 0%
level. The lamp goes back to full power when the channels level is put higher than 0%.
• DIMMER FINE - channel 9
BIT % EFFECT
255 100
0 0.0
• C.T.O. - channel 4
BIT % EFFECT
0 0.0
FILTER EXCLU DED
255 100
FILTER INSERT ED
CHANNEL 4
CTO
• STOP / STROBE - channel 7
IMPORTANT: The lamp dim to half power 1 second after the channel stay at
0% level. The lamp goes back to full power when the channel level is put higher than 0%.
MACRO
BIT % EFFECT
252 - 255 98.7 - 100
OPEN
0 - 3 0.0 - 1.2
CLOSED
2
13 - 225 83.7 - 88.2
RANDOM SLOW STROBE
4
1.7
SLOW STROBE (1 f lash/sec)
103 40.5
FAST STROBE (12 flash/sec)
1
04 - 107 41.0 - 42.0
OPEN
108 42.5
SLOW PULSATION
208 - 212 81.7 - 83.2
OPEN
226 - 238 88.7 - 93.2
RANDOM MEDIUM ST ROBE
239 - 251 93.7 - 98.2
RANDOM FAST STROBE
2
07 81.2
FAST PULSATION
MACRO COLOURS - channel 6
• COLOUR WHEEL - channel 5
BIT % EFFECT
255 100
FAST ROTATION 160 rpm
128050.0
0.0
SLOW ROTATION 0.2rpm
BLUE
ORANGE
AQUAMARINE
GREEN
CTO 3200
RED
WHITE
46.0
38.0
30.0
23.0
15.0
8.0
117
97
77
58
39
20
The lamp is linearly dimmed from full power to half power electronicaly and mechanically from half power to off.
• DIMMER - channel 8
BIT % EFFECT
255 100
0 0.0
Page 25
25
ALPHA SPOT HPE 1500
0 0.0
0° POSITIO N
21 8.2
90° POSITIO N
42 16.2
180° POSITIO N
63 24.7
270° POSITIO N
84 33.0
360° POSITIO N
105 41.7
450° POSITIO N
127 49.7
540° POSI TION
STOP
540°
360°
255 100
FAS T ROTATION (150 rpm)
193 75.5
SLOW ROTATION
(2,2 rph)
191 - 192 74.7 - 75.0
STOP
190 74.2
SLOW ROTATION
(2,2 rph)
B
IT % EFFECT
1
28 50.0
F
AST ROTATION (150 rpm)
• GOBO 1 ROTATION - channel 14
• GOBO 1 FINE - channel 15
• STATIC GOBO CHANGE - channel 12
GOBO 8 SHAKE, FAST SPEED
GOBO 8 SHAKE, SLOW SPEED GOBO 7 SHAKE, FAST SPEED
GOBO 7 SHAKE, SLOW SPEED GOBO 6 SHAKE, FAST SPEED
GOBO 6 SHAKE, SLOW SPEED GOBO 5 SHAKE, FAST SPEED
GOBO 5 SHAKE, SLOW SPEED GOBO 4 SHAKE, FAST SPEED
GOBO 4 SHAKE, SLOW SPEED GOBO 3 SHAKE, FAST SPEED
GOBO 3 SHAKE, SLOW SPEED GOBO 2 SHAKE, FAST SPEED
GOBO 2 SHAKE, SLOW SPEED GOBO 1 SHAKE, FAST SPEED
GOBO 1 SHAKE, SLOW SPEED FAST ROTATION (100 rpm)
SLOW ROTATION (5 rpm) STOP SLOW ROTATION (5 rpm)
FAST ROTATION (100 rpm)
GOBO 8
GOBO 7
GOBO 6
GOBO 5
GOBO 4
GOBO 3
GOBO 2
GOBO 1
WHITE
BIT % EFFECT
MACRO
255
244 243
232 231
220 219
208 207
196 1
95
184 183
172 171
160 159
118
114 - 117
113
72
64 - 71
56 - 63
48 - 55
40 - 47
32 - 39
24 - 31
16 - 23
8 - 15
0 - 7
100
95.5
95.0
91.0
90.5
86.2
86.0
81.7
81.2
76.7 7
6.2
72.0
71.7
67.5
67.0
63.0
62.5
46.2
44.7 - 46.0
44.2
28.2
25.0 - 28.0
22.0 - 24.7
18.7 - 21.7
15.5 - 18.2
12.5 - 15.0
9.5 - 12.0
6.2 - 9.0
3.2 - 6.0
0 - 3.0
ROTATING GOBO 1 CHANGE - channel 13
MACRO
GOBO 6 SHAKE, FAST SPEED
GOBO 6 SHAKE, SLOW SPEED GOBO 5 SHAKE, FAST SPEED
GOBO 5 SHAKE, SLOW SPEED GOBO 4 SHAKE, FAST SPEED
G
OBO 4 SHAKE, SLOW SPEED
GOBO 3 SHAKE, FAST SPEED
GOBO 3 SHAKE, SLOW SPEED GOBO 2 SHAKE, FAST SPEED
GOBO 2 SHAKE, SLOW SPEED GOBO 1 SHAKE, FAST SPEED
GOBO 1 SHAKE, SLOW SPEED GOBO 6
GOBO 5
GOBO 4
GOBO 3
GOBO 2
GOBO 1
WHITE
BIT % EFFECT
255
235 234
214 2
13
1
93
192
1
72
171
151 1
50
130
112-129
93-111
75-92
56-74
38-55
19-37
0-18
100
92.0
91.7
84.0
83.7
7
5.5
75.0
67.5
67.0
59.0
58.7
51.0
44.0-50.5
36.2-43.7
29.5-36.0
22.0-29.0
14.7-21.7
7.5-14.2
0-7.0
Continue
0
0
.
0
M
I
N
I
M
U
M
A
P
E
R
T
U
R
E
2
5
2
-
2
5
5
9
8
.
7
-
1
0
0
M
A
X
I
MUM
A
P
E
R
T
URE
B
I
T
%
E
F
F
E
C
T
2
5
1
9
8
.
2
F
A
S
T
P
UL
S
A
T
I
O
N,
F
A
S
T
CL
O
S
I
NG
2
1
2
8
3
.
2
S
L
O
W
P
U
L
S
A
T
IO
N
, F
A
S
T
C
L
O
S
IN
G
2
1
1
8
3
F
A
S
T
P
U
L
S
A
T
IO
N
, FA
S
T
O
P
E
N
IN
G
1
7
2
6
7
.
5
S
LO
W
P
U
LS
A
T
I
O
N
,
F
A
S
T
O
P
E
N
I
N
G
1
7
1
6
7
F
A
S
T
P
UL
S
A
TI
O
N
1
3
2
5
1
.
7
S
L
OW
P
UL
S
A
TI
O
N
1
2
8
-
1
3
1
5
0
.
0
-
5
1
.
2
M
A
X
I
M
UM
A
P
E
R
TUR
E
MACR
O
IRIS - channel 10
0 0.0
MINIMUM APERTURE
252 - 255 98.7 - 100
MAXIMUM APERTURE
B
IT
%
EFFECT
2
51 98.2
F
AST PULSATION, FAST CLOSING
212 83.2
S
LOW PULSATION, FAST CLOSING
211 83
FAST PULSATION, FAST OPENING
1
72 67.5
S
LOW PULSATION, FAST OPENING
171 67
F
AST PULSATION
1
32 51.7
SLOW PULSATION
128 - 131 50.0 - 51.2
M
AXIMUM APERTURE
MACRO
• ANIMATED STAR GOBO – channel 11
BIT %
255 100
127 50.0
0 0.0
Page 26
26
ALPHA SPOT HPE 1500
ROTATING GOBO 2 CHANGE - channel 16
MACRO
GOBO 6 SHAKE, FAST SPEED
GOBO 6 SHAKE, SLOW SPEED GOBO 5 SHAKE, FAST SPEED
GOBO 5 SHAKE, SLOW SPEED GOBO 4 SHAKE, FAST SPEED
G
OBO 4 SHAKE, SLOW SPEED
GOBO 3 SHAKE, FAST SPEED
GOBO 3 SHAKE, SLOW SPEED GOBO 2 SHAKE, FAST SPEED
GOBO 2 SHAKE, SLOW SPEED GOBO 1 SHAKE, FAST SPEED
GOBO 1 SHAKE, SLOW SPEED GOBO 6
GOBO 5
GOBO 4
GOBO 3
GOBO 2
GOBO 1
WHITE
BIT % EFFECT
255
235 234
214 2
13
1
93
192
1
72
171
151 1
50
130
112-129
93-111
75-92
56-74
38-55
19-37
0-18
100
92.0
91.7
84.0
83.7
7
5.5
75.0
67.5
67.0
59.0
58.7
51.0
44.0-50.5
36.2-43.7
29.5-36.0
22.0-29.0
14.7-21.7
7.5-14.2
0-7.0
0 0.0
0° POSITIO N
21 8.2
90° POSITIO N
42 16.2
180° POSITIO N
63 24.7
270° POSITIO N
84 33.0
360° POSITIO N
105 41.7
450° POSITIO N
127 49.7
540° POSI TION
STOP
540°
360°
255 100
FAS T ROTATION (150 rpm)
193 75.5
SLOW ROTATION
(2,2 rph)
191 - 192 74.7 - 75.0
STOP
190 74.2
SLOW ROTATION
(2,2 rph)
B
IT % EFFECT
1
28 50.0
F
AST ROTATION (150 rpm)
• GOBO 2 ROTATION - channel 17
• GOBO 2 FINE - channel 18
BIT %
255 100
127 50.0
0 0.0
ANIMATION DISK INSERTION - channel 19
• ANIMATION DISK ROTATION - channel 20
• PRISM INSERTION - channel 21
• PRISM ROTATION - channel 22
STOP
FAST ROTATION (120 rpm)
SLOW ROTATION (3 rph)
SLOW ROTATION (3 rph)
FAST ROTATION (120 rpm)
BIT % EFFECT
191 - 192 74.7 - 75.0
255 100
193 75.5
190 74.2
128 50.0
STOP
540
°
360
°
0
°
POSITION 540°127 49.7
POSITION 450°
105 41.7
POSITION 360°
84 33.0
POSITION 270°
63 24.7
POSITION 180°
42 16.2
0 0.0
POSITION 0°
POSITION 90°
21 8.2
BIT % EFFECT
255 100
DISK INSERTED
0 0.0
DISK EXCLUDED
B
IT % EFFECT
255 100
FAST ROTATION (120 rpm)
0 0.0
FAS T ROTATION (120 rpm)
131 51.2
SLOW ROTATION (4,4 rph)
125 - 130 49.0 - 51.0
STOP
124 48.7
SLOW ROTATION (4,4 rph)
BIT % EFFECT
128 50.0
PRISM EXCLUDED
0 0.0
2
55 100
PRISM INSERTED
127 49.7
Page 27
27
ALPHA SPOT HPE 1500
FROST - channel 23
BIT % EFFECT
255 100
FROST INSERTED
0 0.0
FROST EXCLUDED
FOCUS - channel 24
• FOCUS FINE -channel 25
• MACRO EFFECTS - channel 29
BIT % EFFECT
255 100
NEAR
0 0.0
DISTANT
BIT % EFFECT
2
55 100
NEAR
0 0.0
DISTANT
AUTOFOCUS DISTANCE - channel 27
BIT % EFFECT
255 100
100 METRES
5
0 METRES
40 METRES
30 METRES
20 METRES
10 METRES
5 METRES
AUTOFOCUS OFF
1
28
102
77
51
26
13
0-7
5
0.0
40.0
30.0
20.0
10.0
5.0
0.0-3.0
• ZOOM - channel: 26
BIT % EFFECT
255 100
NARROW BEAM
0 0.0
WIDE BEAM
AUTOFOCUS ADJUSTMENT - channel 28
B
IT
%
EFFECT
128 50.0
0 0.0
255 100
FOCUS FINE
FOCUS FINE
Page 28
28
ALPHA SPOT HPE 1500
• PAN FINE - channel 31
Operation with option InvertPan
G
Off
(Tilt conventionally represented at 14% and option Invert TiltGOff)
BIT
%
255 100
0 0.0
Operation with option InvertPanGOn (Tilt conventionally represented at 14% and option Invert Tilt
G
Off)
BIT
%
255 100
0 0.0
O
peration with option InvertPan
G
O
n
(
Tilt conventionally represented at 14% and option Invert Tilt
G
O
ff)
B
IT
%
255 100
0 0.0
BIT
%
255 100
0 0.0
PAN - channel 30
O
peration with option InvertPan
G
O
ff
(
Tilt conventionally represented at 14% and option Invert Tilt
G
O
ff)
• TILT FINE - channel 33
Operation with option Invert Tilt
G
Off
(Pan conventionally represented at 0% and option Invert Pan
G
Off)
BIT %
255 100
0 0.0
SE
T X
S E L
D M X
SE
T X
S E L
D M X
Operation with option Invert TiltGOn (Pan conventionally represented at 0% and option Invert Pan
G
Off)
TILT - channel 32
Operation with option Invert Tilt
G
Off
(Pan conventionally represented at 0% and option Invert PanGOff)
BIT
%
255 100
128 50.0
0 0.0
S
E
T X
S E L
D M X
S
E
T X
S E L
D M X
SE
T X
S E L
D M X
Operation with option Invert TiltGOn (
Pan conventionally represented at 0% and option Invert Pan
G
O
ff)
BIT
%
255 100
128 50.0
0 0.0
SE
T X
S E L
D M X
S
E
T X
S E L
D M X
SE
T X
S E L
D M X
B
IT
%
2
55 100
0 0.0
S
E
T X
S E L
D M X
SE
T X
S E L
D M X
Page 29
29
ALPHA SPOT HPE 1500
FUNCTION - channel: 34
BIT % EFFECT
255 100
78 30.5
51 20.0
39 15.0
26 10.0
13 5.0
0-12 0.0-4.7
L
INEAR (DEFAULT)
UNUSED RANGE
UNUSED RANGE
77 30.0
QUITE MODE OFF(DEFAULT)
64 25.0
QUITE MODE ON
CONVENTIONAL
NORMAL SPEED
FAS T SPEED (DEFAULT)
DIMMER CURVE FUNCTION
QUITE MODE FUNCTION
PAN-TILT F
UNCTION
The functions are actived passing through unused range and staying 5 seconds in n
ecessary level.
• RESET - channel: 35
BIT % EFFECT
255 100
128 50.0
127 49.7
77
30.0
76 29.7
26 10.0
25 9.7
0 0.0
Complete reset is activated passing t
hroug the unused range and staying
5
seconds in complete reset levels.
COMPLETE RESET PAN / TILT RESET
PAN / TILT RESET EFFECTS RESET
EFFECTS RESET
UNUSED RANGE
Pan / Tilt reset is activated passing throug the unused range and staying 5
seconds in Pan / Tilt reset levels.
E
ffects reset is activated passing
t
hroug the unused range and staying
5 seconds in Effects reset levels.
COMPLETE RESET
LAMP CONTROL (only with option LAMP DMX On) - channel: 36
IMPORTANT: Alpha Spot HPE 1500 is not provided with hot restrike igniter
LAMP ON (1500 W)
L
AMP ON (1500 W)
BIT
% EFFECT
255 100
1
80 70.5
0 0.0
101 39.5 100 39.0
LAMP OFF
179 70.0
26 10.0
LAMP OFF
25 9.7
UNUSED RANGE
Lamp ignition after 5 s in full power levels.
Lamp switch off passing throug the unused range and staying 5 s in Lamp OFF levels.
LAMP ON (1200 W)
LAMP ON (1200 W)
Immediate transition from full to half power.
Immediate transition from half to full power.
Lamp ignition not allowed in half power.
ON
ON ON
OFF
ON
OFF
Page 30
30
ALPHA SPOT HPE 1500
T
iming Channel Channel function
37 Pan - Tilt time Pan – Tilt – Pan Fine – Tilt Fine 38 Colour time Cyan - Magenta - Yellow – C.T.O. – Color wheel 39 Beam time Dimmer - Iris -Focus effects movment - Focus - Zoom - Frost – Rotating Prism change – Frost insertion
40 Gobo time Gobo Fix - Rotating Gobo 1/2 change – Animation Disk insertion
BIT Seconds
0 Full 1 0.2 2 0.4 3 0.6 4 0.8 5 1 6 1.2 7 1.4 8 1.6 9 1.8 10 2 11 2.2 12 2.4 13 2.6 14 2.8 15 3 16 3.2 17 3.4 18 3.6 19 3.8 20 4 21 4.2 22 4.4 23 4.6 24 4.8 25 5 26 5.2 27 5.4 28 5.6 29 5.8 30 6 31 6.2 32 6.4 33 6.6 34 6.8 35 7 36 7.2 37 7.4 38 7.6 39 7.8 40 8 41 8.2 42 8.4
BIT Seconds
43 8.6 44 8.8 45 9 46 9.2 47 9.4 48 9.6 49 9.8 50 10 51 10.2 52 10.4 53 10.6 54
11
55 56
12
57 58
13
59 60 61 14 62 63
15
64 65 66 16 67 68
17
69 70 71 18 72 73
19
74 75 76 20 77 78 79 21 80 81
22
82 83 84 23 85
BIT Seconds
86
24
87 88 89 25 90 91
26
92 93 94 27 95 96
28
97 98 99 29 100 101 102 30 103 104
31
105 106 107 32 108 109
33
110 111 112 34 113 114
35
115 116 117 36 118 119
37
120 121 122 38 123 124 125 39 126 127
40
128
BIT Seconds
129 130 41 131 132
42
133 134 135 43 136 137
44
138 139 140 45 141 142
46
143 144 145 47 146 147
48
148 149 150 49 151 152 153 50 154 155
51
156 157 158 52 159 160
53
161 162 163 54 164 165
55
166 167 168 56 169 170
57
171
BIT Seconds
172 173 58 174 175 176 59 177 178
60
179 180 181 65 182 183
70
184 185 186 75 187 188
80
189 190 191 85 192 193
90
194 195 196 95 197 198
100
199 200 201 110 202 203 204 120 205 206
130
207 208 209 140 210 211
150
212 213 214 160 215
BIT Seconds
216
170
217 218 219 180 220 221
190
222 223 224 200 225 226 227 210 228 229
220
230 231 232 230 233 234
240
235 236 237 250 238 239
260
240 241 242 270 243 244
280
245 246 247 290 248 249
300
250 251 252
310
253 254
255
Follow cue
Data
TIMING CHANNELS
TIME TABLE
Page 31
Page 32
CLAY PAKY S.p.A. - Via Pastrengo, 3/b - 24068 Seriate (BG) Italy - Tel. +39-035-654311 - Fax +39-035-301876 - www.claypaky.it
Rev. PRELIMINARY 10/09
Cod. 099105 - EN
www.gfstudio.com
Loading...