Congratulations on choosing a Clay Paky product!
We thank you for your custom.
Please note that this product, as all the others in the rich Clay
Paky range, has been designed and made with total quality to
ensure excellent performance and best meet your expectations
and requirements.
Carefully read this instruction manual in its entirety and keep it
safe for future reference. It is essential to know the information
and comply with the instructions given in this manual to ensure
the fitting is installed, used and serviced correctly and safely.
CLAY PAKY S.p.A. disclaims all liability for damage to the fitting
or to other property or persons deriving from installation, use and
maintenance that have not been carried out in conformity with this
instruction manual, which must always accompany the fitting.
CLAY PAKY S.p.A. reserves the right to modify the
characteristics stated in this instruction manual at any time and
without prior notice.
1
Page 2
700W
7.5
SAFETY INFORMATION
• Installation
Make sure all parts for fixing the projector are in a good state of repair.
Make sure the point of anchorage is stable before positioning the projector.
The safety chain must be properly hooked onto the fitting and secured to the framework, so that, if
the primary support system fails, the fitting falls as little as possible.
If the safety chain gets used, it needs to be replaced with a genuine spare.
• Minimum distance of illuminated objects
The projector needs to be positioned so that the objects hit by the beam of light are at least 7.5
metres (24’ 7”) from the lens of the projector.
• Minimum distance from flammable materials
The projector must be positioned so that any flammable materials are at least 0.20 metres (8") from
every point on the surface of the fitting.
• Mounting surfaces
It is permissible to mount the fitting on normally flammable surfaces.
• Maximum ambient temperature
Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
IP20
• IP20 protection rating
The fitting is protected against penetration by solid bodies of over 12mm (0.47”) in diameter (first
digit 2), but not against dripping water, rain, splashes or jets of water (second digit 0).
• Protection against electrical shock
Connection must be made to a power supply system fitted with efficient earthing (Class I appliance
according to standard EN 60598-1).
It is, moreover, recommended to protect the supply lines of the projectors from indirect contact
and/or shorting to earth by using appropriately sized residual current devices.
• Connection to mains supply
Connection to the electricity mains must be carried out by a qualified electrical installer.
Check that the mains frequency and voltage correspond to those for which the projector is designed
as given on the electrical data label.
This label also gives the input power to which you need to refer to evaluate the maximum number
of fittings to connect to the electricity line, in order to avoid overloading.
• Temperature of the external surface
The maximum temperature that can be reached on the external surface of the fitting, in a thermally
steady state, is 150°C (302°F).
• Maintenance
Before starting any maintenance work or cleaning the projector, cut off power from the mains
supply.
After switching off, do not remove any parts of the fitting for at least 10 minutes. After this time the
likelihood of the lamp exploding is virtually nill. If it is necessary to replace the lamp, wait for another
20 minutes to avoid getting burnt.
The fitting is designed to hold in any splinters produced by a lamp exploding. The lenses must be
mounted and, if visibly damaged, they have to be replaced with genuine spares.
ALPHA BEAM 700
Pb
• Lamp
The fitting mounts a high-pressure lamp that needs an external igniter. This igniter is fitted onto the
apparatus.
- Carefully read the "operating instructions" provided by the lamp manufacturer.
- Immediately replace the lamp if damaged or deformed by heat.
• Battery
This product contains a rechargeable lead-acid battery. To preserve the environment, please
dispose the battery at the end of its life according to the regulation in force. Instructions on how to
remove the battery from the product are available on www.claypaky.it
The products referred to in this manual conform to the European Community Directives to which
they are subject:
• Low Voltage 2006/95/CE
• Electromagnetic Compatibility 2004/108/CE
2
Page 3
UNLOCKED
LOCKED
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
4
5
°
1
9
0
°
9
0
°
9
0
°
9
0
°
LOCKED
UNLOCKED
UNPACKING AND PREPARATION
Lamp 700W
(fitted into projector)
099101
2 x 183102/802
Packing contents - Fig. 1
23
PAN Mechanism Lock and Release (every 90°) - Fig. 2
TILT Mechanism Lock and Release (every 45°) - Fig. 3
ALPHA BEAM 700
3
Page 4
4
1
2
3
2
1
INSTALLATION AND START-UP
Installing the projector - Fig. 4
The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall.
WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/003 available on request).
This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base.
5
Connecting and disconnecting power cable - Fig. 5
ALPHA BEAM 700
4
Page 5
CONTROL PANEL
1
2
Dmx Address
Warning Message
Fixture ID
L
N
SIGNAL
S
CREEN
DMX 512
5 PIN
1
2
3
4
5
S
IGNAL
SCREEN
1
3
2
DMX 512
3 PIN
SIGNAL
SIGNAL
DMX 512
6
onnecting to the mains supply - Fig. 6
C
Mains
7
Connecting to the control signal line (DMX) - Fig. 7
Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 3 or 5-pin male/female
connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.
IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the
shield braid and to pin 1 of the connectors.
8
Switching on the projector - Fig. 8
Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:
Model Firmware xxx (Fixture ID) System errors
Alpha BEAM Version X.X.X Dmx Address xxx E: .........................
700 Date - Hour W: .........................
On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 50% - Tilt 50%). The control panel
(Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two
conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address
(if set).
During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the
key will be cancelled.
F
ALPHA BEAM 700
5
Continue
➔
Page 6
28
28
9
Reversal of the display - Fig. 9
To activate this function, press UP
maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again.
Setting the projector starting address
On each projector, the starting address must be set for the control signal (addresses from 1 to 512).
The address can also be set with the projector switched off.
Setting the address: see pag. 8.
Setting the projector Fixture ID
On each projector, the Fixture ID address must be set for an easy identification of the fixtures in an installation (ID from 1 to 255).
The Fixture ID address can be set with the projector switched off.
Setting the Fixture ID: see pag. 8.
and DOWN Ckeys simultaneously while the display is in the rest mode. This status will be memorised and
B
Functions of the buttons - Using the menu
F
C
DOWN
B
D
LEFT
E
RIGHT
USING THE MENU:
1) Press
2) Use the UP
• Setup (Setup Menu): To set the setting options.
• Option (Option Menu): To set the operating options
• Informations (Informations Menu): To read the counters, software version and other information.
• Manual Control (Manual control Menu): To trigger the test and manual control functions.
• Test (Test Menu): To check the proper functionning of effects
• Advanced (Advanced Menu): Access to the "Advanced menu" is recommended for a trained technical personnel.
To enable the "Advanced" see pag.13
3) Press
4) Use the UP
once – “Main Menu” appears on the display.
F
and DOWN Ckeys to select the menu to be used:
B
to display the first item in the selected menu.
F
and DOWN Ckeys to select the MENU items.
B
Confirms the displayed value, or activates the displayed function, or enters the successive
menu.
Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.
Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu.
UP
Return to the top level
Commute from units, tens, hundreds, in the "Address", "Fixture ID" and "Calibration" menù.
Setting addresses and options with the projector disconnected
The projector’s DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply.
All that is needed is to press
the display will switch off again after a wait time of 30 seconds.
ALPHA BEAM 700
to momentarily activate the display and thus access the settings. Once the required operations have been carried out,
F
6
Page 7
MENU SETTING
MAIN MENU
13
mx
Set Up
Option
nformation
I
anual
M
ontrol
C
est
T
D
ddress
A
Channel
ode
M
ixture ID
F
Ethernet
Interface
2
ystem
Option
Lamp Dmx
an / Tilt
P
olor
C
Shutter
Invert
an
P
nvert
I
ilt
T
wap
S
an-Tilt
P
ncoder
E
Pan-Tilt
Color
Mixing
olor
C
ixing curve
m
Fixed Wheel
Shortcut
Shutter
n Error
O
immer On
D
hutter
S
Information
S
rrors
E
Fixture
ours
H
amp
L
Hours
amp
L
trikes
S
System
ersion
V
Board
Diagnost.
mx
D
Monitor
ans
F
onitor
M
4
Advanced
Manual
Control
Lamp
Power Mode
Display
Setting
5
Test
Pan / Tilt
4-700W
Full fan speed
400W
Low fan speed
4-700W
Auto fan speed
Default
Preset
User
Preset 1
User
Preset 2
User
Preset 3
6
Advanced
Network
params
Access code
1234
ALPHA BEAM 700
Reset
Channel
Colour
Beam
Gobo
All
7
Upload
Firmware
Setup
Model
Calibration
Continue
➔
Page 8
NOTE: On grey the default options
SET UP MENU
et Up
S
mx
D
Address
hannel
C
ode
M
Fixture ID
ddress xxx
A
Standard
ector
V
Value xxx
DMX ADDRESS
NOTE: without the DMX signal the Address (XXX) flashing
Allows you to select the DMX ADDRESS.
1) Press
2) Use the UP
Address.
3) Press
CHANNEL MODE
Allows you to select a channel arrangement from the two available.
1) Press
Vector).
2) Use the UP
settings:
- Standard
- Vector
3) Press
FIXTURE ID
Allows you to select the FIXTURE ID.
1) Press
2) Use the UP
3) Press
- the current DMX Adress appear on the display.
F
and DOWN C, RIGHT Ekeys to plan the DMX
B
to confirm the selection or LEFT Dto keep current settings.
F
- the current settings appear on the display (Standard or
F
and DOWN Ckeys to select one of the following
B
to confirm the selection or LEFT Dto keep current settings.
F
- the current Fixture ID appear on the display.
F
, DOWN C, RIGHT Ekeys to plan the Fixture ID.
B
to confirm the selection or LEFT Dto keep current settings.
F
Ethernet
Interface
Control
Protocol
Repeat on
DMX
ETHERNET INTERFACE
It lets you set the Ethernet settings to be attributed to the projector.
1) Premere
2) Use the UP
options to set:
Control Protocol
It lets you select the “Control Protocol” Art-net to assign according to the
control unit used:
1) Press
2) Use the UP
- Disabled
- Art-net on IP 2
- Art-net on IP 10
3) Press
Repeat on DMX
It lets you enable the transmission of the Ethernet protocol by DMX signal
to all the connected projectors.
1) Press
2) Use the UP
- Disabled: DMX transmission disabled.
- Enabled on primary: DMX transmission enabled.
3) Press
.
F
and DOWN Ckeys to select the “Ethernet Interface”
B
the current setting appears on the display.
F
and DOWN Ckeys to select one of the following settings:
B
to confirm the selection or LEFT Dto keep the current setting.
F
the current setting appears on the display.
F
and DOWN Ckeys to select one of the following settings:
B
to confirm the selection or LEFT Dto keep the current setting.
F
ALPHA BEAM 700
Universe
Universe
It lets you assign the “Universe” number to be assigned to a series of
projectors.
1) Press
2) Use the UP
3) Press
8
– the current Universe address appears on the display.
F
, DOWN C, RIGHT Ekeys to set the Universe address.
B
to confirm the selection or LEFT Dto keep the current setting.
F
Page 9
OPTIONS MENU
Option
Lamp Dmx
Pan / Tilt
n
O
ff
O
Invert
an
P
Invert
Tilt
wap
S
Pan-Tilt
O
Off
O
Off
O
Off
LAMP DMX
Used for enabling lamp remote control channel.
1) Press
2) Use the UP
the lamp remote control channel.
3) Press
n
n
n
PAN / TILT
Invert pan
Used for reversing Pan movement.
1) Press
2) Use the UP
PAN inversion.
3) Press
Invert tilt
Used for reversing tilt movement.
1) Press
2) Use the UP
Tilt inversion.
3) Press
Swap Pan-Tilt
Used for swapping Pan and Tilt channels (as well as Pan fine and Tilt fine).
1) Press
2) Use the UP
Pan and Tilt channel swap.
3) Press
- the current settings appear on the display (On or Off).
F
and DOWN Ckeys to enable (On) or disable (Off)
B
to confirm the selection or LEFT Dto keep current settings.
F
- the current settings appear on the display (On or Off).
F
and DOWN Ckeys to enable (On) or disable (Off)
B
to confirm the selection or LEFT Dto keep current settings.
F
- the current settings appear on the display (On or Off).
F
and DOWN Ckeys to enable (On) or disable (Off)
B
to confirm the selection or LEFT Dto keep current settings.
F
- the current settings appear on the display (On or Off).
F
and DOWN Ckeys to enable (On) or disable (Off)
B
to confirm the selection or LEFT Dto keep current settings.
F
Color
Encoder
Pan-Tilt
Color
Mixing
Color
Mixing curve
On
Off
Rgb
Cmy
Curve 1
Curve 2
Encoder Pan-Tilt
Used for enabling the Pan / Tilt encoders.
1) Press
2) Use the UP
Pan / Tilt encoders.
3) Press
COLOR
Color mixing
Used for reversing the CMY color mixing system.
1) Press
2) Use the UP
RGB color mixing mode
CMY color mixing mode
3) Press
Color mixing curve
It lets you select the “Color mixing curve” from the two available.
1) Press
2)
Use the UP Band DOWN Ckeys to select one of the following settings:
Curve 1
Curve 2
3) Press
- the current settings appear on the display (On or Off).
F
and DOWN Ckeys to enable (On) or disable (Off)
B
to confirm the selection or LEFT Dto keep current settings.
F
- the current settings appear on the display (On or Off).
F
and DOWN Ckeys select one of the following settings:
B
to confirm the selection or LEFT Dto keep current settings.
F
the current setting appears on the display.
F
to confirm the selection or LEFT Dto keep the current setting.
F
ALPHA BEAM 700
Fixwheel
Shortcut
On
Off
Fixed wheel short-cut
Used for optimizing color change time so that the disc turns in the direction that requires shorter movement.
1) Press
2) Use the UP
color change optimization.
3) Press
9
– the current settings appear on the display (On or Off).
F
and DOWN Ckeys to enable (On) or disable (Off)
B
to confirm the selection, or LEFT Dto keep current settings.
F
Continue
➔
Page 10
hutter
S
Power Mode
hutter
S
n Error
O
immer On
D
hutter
S
-700W
4
Full fan speed
400W
Low fan speed
-700W
4
Auto fan speed
On
O
O
O
SH
U
T
T
ER
Sh
u
t
t
e
r o
n
e
rro
ff
n
ff
U
s
e
d
p
o
s
i
ti
1
)
Pr
2
)
U
aut
3
)
P
D
im
m
E
nables
1
)
Pr
2
)
U
th
3
)
Pr
s
e
POW
Al
l
o
w
1
)
Pr
2
)
U
se
-
4
h
wo
-
4
(4
CONTROL
-
4
h
th
3
) Pre
o
es
s
re
es
s
e
e
ER
s
e
-
a
0
-7
a
e t
e
tti
s
7
0
e
fo
n
omat
e
a
l
0
l
s
s
s
r o
autom
s
s
n
y
s
t
h
0
f-
rk
W
0
0
f-p
fa
s
r
e
r
F
he U
s
F
F
t
he
u
to
s
g
s
M
o
u
F
e
0
W
p
o
a
W
0
W
o
n
F
a
u
r
o
i
c
n
Sh
U
m
F
.
OD
to
U
P
w
t
Fu
Low
) wh
Auto
we
s
to
r
.
P
s
t
– t
P
a
-
B
F
e
r
r (4
swi
to
m
t
t
op/
o
atic
ti
to
E
s
th
u
l
l
r
a
he c
B
c
u
he
B
c
e
l
e
ll
(
4
s
fa
i
l
c
tch
c
t
c
e
h
ti
c
a
l
l
y
ur
r
ent
a
n
d
s
t
robe c
o
n
f
i
rm
t
e
r
c
los
ing of the dim
c
ur
r
ent
a
n
d
l
o
s
i
n
g
c
o
n
fi
r
e
c
t
a
Po
c
u
r
r
e
a
n
d
D
f
a
n
s
p
0
0
W
)
u
p
e
e
d
.
n
s
pe
th
e
Fa
a
n
n
e
l
fa
n
s
pe
0
0
W
) u
fro
m
o
n
fi
rm
th
c
s
D
t
h
D
o
m
w
n
t
OW
e
e
s
e
y
o
si
Fu
l
o
l
os
e
s
OW
f th
th
s
d
i
n
d
n
u
e
n
e
s
i
et
t
OW
i
s
e
et
e
r
e
tti
N
:
g
:
a
c
d:
g
th
l
l
s
n
g
i
ngs
ng i
l
e
t
i
ngs
N
e
e
s
M
n
C
L
a
th
L
a
l
a
L
sp
e
l
th
appear
N
C
n t
c
t
i
C
d
i
m
e
o
d
g
s
ke
m
p
e
L
m
p
wa
y
n
o
a
m
e
L
e
e
e
c
ti
e
s
to
k
he ev
o
n
,
o
m
er w
appear
k
m
e
r
l
e
c
ti
o
e
fr
o
a
p
p
ys
c
a
n
AM
P
c
o
n
s
wo
n
l
y
s
p
ca
A
M
P
d
to
L
o
n
o
p
/s
tr
o
b
e
on the di
ey
s
t
o enabl
ent
of
P
r
LE
F
T
D
hen the s
on the di
ey
s
to
e
n
.
n
, o
r
LE
m
th
e
th
r
e
a
r
o
n
th
t
o
se
le
ct
o
c
h
a
n
g
e
C
ON
T
R
s
ta
n
tl
y
wo
rk
s
a
t L
wi
tc
h
th
e
n
ch
a
n
g
e
CONTROL
o
w
sp
e
e
r
LE
F
T
D
i
n
s
pl
e (O
an/
T
t
o
trobe is
s
pl
a
b
l
e
F
T
e
e
a
e
d
i
s
n
e
o
fr
o
m
OL
rk
s
o
w s
l
a
m
fro
m
ch
d
re
to
th
ay
i
l
k
ay
(
D
v
p
f
c
h
p
sp
k
e
(
t
pos
e
On
a
l
a
t
h
fu
a
i
n
ON
fu
a
e
e
e
c
(
i
l
y
e
l
n
p
l
n
cti
e
v
e
n
O
n or
n) or di
i
t
i
on error.
p
c
u
om
pletely
O
n
or
)
o
r
to
k
a
b
l
e
.
.
f
o
llo
l
-
p
o
w
n
e
l
.
h
a
l
f-p
e
e
d
. W
a
n
l
-p
o
we
n
e
l
. A
ve
l
e
p
c
u
O
rre
d
w
e
d
y.
t
O
e
F
u
rre
o
f
ff)
s
abl
n
t
ff
)
i
s
a
e
p
in
g
r
(
7
a
n
o
we
i
th
OFF.
r
(7
to
n
s
.
s
m
.
b
c
t s
Pa
c
se
0
r
L
0
e (O
e
t
los
l
e
u
t
0
a
l
m
0
a
ti
e
n
t
i
(
r
t
in
W
w
AM
W
ca
tti
/T
n
g
ed.
Off)
r
e
g
)
a
o
)
n
i
l
t
f
f
)
s
.
n
t
s:
to
y
s
d
e
P
to
l
l
y
g
.
Display
Setting
On
Off
Default
Preset
User
Preset 1
User
Preset 2
User
Preset 3
Reset To
Dafault
Go Back
Load
Preset 1
Save To
Preset 1
Load
Preset 2
Save To
Preset 2
Load
Preset 3
Save To
Preset 3
DISPLAY
Us
e
d
fo
r a
u
to
m
a
ti
c
a
l
l
y
re
d
u
c
e
b
ri
g
h
tn
e
s
s
o
n
th
e
d
i
s
p
l
a
y
a
fte
r a
b
o
u
t 3
s
e
c
o
n
d
s
i
n
i
d
l
e
.
1
)
Pre
s
s
-
th
e
c
u
rre
n
t
s
e
tti
n
g
s
a
p
p
e
a
r
o
n
th
e
d
i
s
p
l
a
y
(On
o
r
2
F
)
Use
t
h
e
UP
d
e
cre
a
si
3
)
P
ress
F
SETTING
Us
e
d
to
s
a
relative submenus.
1)
Press
2)
3)
4)
5)
(*) DEFAULT PRESET
Used for restoring default values on all options menu items and relevant submenus.
1)
F
Use the UP
configurations:
- Default preset (*)
- User preset 1
- User preset 2
- User Preset 3
Press
F
Use the UP
- Load preset X to recall a previously stored configuration.
- Save to preset X to store the current configuration.
a confirmation message (Are you sure?) appears on the display.
Select YES to confirm the selection or NO to keep the current setting
and return to the next higher level.
Press
F
a
n
d
DOW
N
ke
ys t
o
e
n
a
b
l
e
(On
) o
B
n
g
o
f
d
i
sp
l
a
y b
t
o conf
i
rm t
v
e
3
d
i
ffe
re
n
- “Default preset” appears on the display.
and DOWN
B
- “Load preset X” appears on the display.
and DOWN
B
, a confirmation message (Are you sure?) appears on the display.
ri
g
he sel
t
s
e
C
h
t
n
e
ect
tti
n
g
C
ss.
i
on or LE
F
T
D
s
o
f
th
e
i
te
m
s
i
keys to select one of the following
C
keys to select:
r d
t
o keep current
n
th
e
o
p
Off).
i
sa
b
l
e
(Of
f
) t
h
set
t
i
ngs.
ti
o
n
s
m
e
n
u
a
n
0
e
d
ALPHA BEAM 700
10
Page 11
2) Select YES to confirm the selction or NO to keep current setting.
OPTIONDEFAULT
Lamp DMXOn
Invert PanOff
Invert TiltOff
wap Pan-TiltOff
S
Encoder Pan-TiltOn
Color mixing CMY
Color mixing curveCurve 1
Fixed Wheel Shortcut On
Shutter on error Off
Dimmer on Shutter Off
Power Mode4-700 Full fan speed
Display On
INFORMATION MENU
Information
ystem
S
Errors
ixture
F
Hours
Lamp
Hours
otalXXX
T
artial XXX
P
TotalXXX
Partial XXX
eset...
R
Reset...
SYSTEM ERRORS
Shows a list of warnings and messages relevant to errors occurred since
the fixtures switching-on.
1) Pressing
you are allowed to reset the SYSTEM ERRORS list.
F
A confirmation message (Are you sure you want to clear error list ?)
appears on the display.
2) Select YES to reset the list or NO to go back.
FIXTURE HOURS
Used for displaying projector operating hours (total and partial).
1) Press
- Hours total and partial appears on the display.
F
Total counter
Counts the number of projector working life hours (from manufacture to
date).
Partial counter
Counts the number of partial projector working life hours since the
last reset to date.
2) Press
to reset partial projector working hours a confirmation
F
message (Are you sure?) appears on the display.
3) Select YES to reset partial projectors counter or NO to keep the
current setting and return to the top menu level.
LAMP HOURS
Used for displaying the lamp working hours (total and partial).
1) Press
- Hours total and partial appears on the display.
F
Total counter
Counts the number of projector working hours with the lamp on (from
manufacture to date).
Partial counter
Counts the number of lamp working hours since the last reset to date.
2) Press
to reset partial lamp working hours, a confirmation message
F
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting
and return to the top menu level
ALPHA BEAM 700
Lamp
Strikes
TotalXXX
Partial XXX
Reset...
LAMP STRIKES
Used for displaying the number of times the lamp was turned on (total and
partial).
1) Press
- the number of times the lamp was turned on (total and
F
partial) appears on the display.
Total counter
Counts the number of times the lamp was turned on (from manufacture
to date).
Partial counter
Counts the number of times the lamp was turned on since the last
reset to date.
11
Continue
➔
Page 12
2) Press Fto reset partial lamp strikes hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting
and return to the top menu level
System
ersion
V
oard
B
Diagnost.
mx
D
Monitor
Fans
Monitor
oard Revis. Hw.rv.
B
PU brd x.x.x x.x
C
com.dev x.x
: PT-3f x.x x.x
0
: 8-Ch x.x x.x
1
2: 8-Ch x.x x.x
oard Status Err%
B
:PT-3f Good 0.00
0
1:8-Ch Good 0.00
:8-Ch Good 0.00
2
Fan Speed (RPM)
Ball.In. XXXX
ff.In XXXX
E
Lamp XXXX
SYSTEM VERSION
Used for displaying the software and hardware version of each board
installed in the projector.
CPU brd (CPU board)
0: PT-3f (Pan / Tilt board)
1: 8-Ch (8 channel board)
2: 8-Ch (8 channel board)
BOARD DIAGNOSTIC
Used for displaying the status error of each board installed in the projector:
0: PT-3f (Pan / Tilt board)
1: 8-Ch (8 channel board)
2: 8-Ch (8 channel board)
DMX MONITOR
Used for displaying the projector DMX channel level in bit (Val) and in
percentage (Perc).
FANS MONITOR
Used for displaying the speed of each fan installed in the projector:
Ball. IN (Ballast IN Fan)
Eff.IN (Effects IN Fan)
Lamp (Lamp Fan)
Manual
Control
Network
params
Lamp
Reset
On
Off
No
Yes
NETWORK PARAMS
Allows the "Network" parameters of the projector to be displayed or:
IP address: Internet Protocol address (two projectors must not have the
same IP address)
IP mask: 255.0.0.0
Mac address: Media Access Control: the projector’s Ethernet Address
MANUAL CONTROL
LAMP
Used for turning lamp on and off from the projector control panel.
1) Press
2) Use the
3) Press
and return to the top level.
RESET
Used for resetting the projector.
1) Press
?) appears on the display.
2) Select YES to starting reset the fixture or NO to keep the current setting
and return to the top menu level.
-
the current settings appear on the display (On or Off).
F
UP Band DOWN Ckeys to turn the lamp on (On) or off (Off)
to confirm the selection or
F
to reset the projectors, a confirmation message (Are you sure
F
LEFT Dto keep current settings
ALPHA BEAM 700
Channel
CHANNEL
Used for setting channel levels from the projector control panel.
1) Press
2) Use the UP
3) Press
- the first channel appears on the display.
F
and DOWN Ckeys to select the required channel:
B
and use the UP Band DOWN Ckeys to select the
F
required DMX level (value between 0 and 255).
4) Press LEFT
12
to return to the top menu level.
D
Page 13
TEST MENU
Test
Advanced
an-Tilt
P
olour
C
Beam
Gobo
ll
A
ode
C
234
1
pload
U
Firmware
Transfer the firmware on all
the connected fixtures ?
Are you sure ?
es/No
Y
TEST
Allows you to check the proper functioning of effects.
to confirm the selection or LEFT Dto keep current settings.
F
ADVANCED MENU
To enable the "Advanced Menu" set up the "Access code" (1234) using the
UP
, DOWN C, RIGHT Ekeys.
B
Press
UP LOAD FIRMWARE
Allows you to transfer the firmware from 1 fixture to all the connected fixtures.
1) Press
2) Select YES to start the firmware loading or NO to keep the current set-
- "Menu advanced" appears on the display
F
, a confirmation message appears on the display.
F
ting and return to the top menu level
Setup
Model
Calibration
Changing to a wrong model
may damage the fixture.
Are you sure ?
Yes/No
SETUP MODEL
Allows you to change the default model of projector.
1) Press
2) Select YES to define the model of projector or NO to keep the current
setting and return to the top menu level.
CALIBRATION
Allows you to adjust effects from the control panel to obtain perfect uniformity between the projectors.
1) PressF- “channels” appears on the display.
2) Using the UP
regulate.
3) Press
make the adjustment by setting a value between 0 and 255.
4) Press
tings and return to the top level.
FACTORY DEFAULT
Allows you to restore default values of all channels (128).
1) Press
calibration to factory default ?).
2) Select YES to reset calibration to factory default or NO to keep the
current setting and return to the top menu level.
a confirmation message appears on the display.
F
and DOWN Ckeys, select the effect you wish to
B
and use the RIGHT E, UP Band DOWN Cbuttons to
F
to confirm the selection
F
– a confirmation message appears on the display (Reset
F
or
LEFT Dto keep current set-
ALPHA BEAM 700
13
Page 14
2
1
1
/4 Turn
1
2
1/4 Turn
3
4
MAINTENANCE
1011
Locking and releasing Pan and Tilt movements - Refer to the instructions in the UNPACKING AND PREPARATION section.
Opening the head covers - Fig. 10.
Closing the head covers - Fig. 11.
ALPHA BEAM 700
14
Page 15
Lower Side
Upper Side
2
Lower Side
A
Upper Side
1
A
3
A
1
2
12
13
Opening and closing lamp compartment - Fig. 12
14
Lamp change - Fig 13
Take the new lamp out of its package and insert in the fitting.
WARNING: do not touch the lamp’s envelope with bare hands.
Should this happen, clean the bulb with a cloth soaked in alcohol
and dry it with a clean, dry cloth.
IMPORTANT: Make sure the lamp is inserted with the external
contact (A) facing the elliptical reflector’s slot.
Lamp regulation - Fig. 14
To centre the lamp, turn the three adjusting screws as shown in the figure.
ALPHA BEAM 700
15
Continue
➔
Page 16
1
2
084702/001
085601/001
085909/001
085603/001
085801/001
085910/001
085802/001
085606/001
Upper Side
15
Replacing fixed gobos (ø 31.5 mm – max 25 mm image – thickness max 1.1 mm) - Fig. 15
WARNING: Before using personalised gobos contact Clay Paky.
ALPHA BEAM 700
16
Page 17
Upper Side
2
1
085523/001085506/001
085528/001
085527/001
085526/001
085525/001
085524/001
1
2
16
COATED GLASS GOBOS TYPE 1COATED GLASS GOBOS TYPE 2
Grey/Black side away from lamp
Reflective side towards lamp
Coated side towards lamp
Uncoated side
Coated side
Uncoated side
Bearing group replacement - Fig. 16
17
Replacing rotating gobos (ø 25.7 mm - max 23 mm image – thickness max 1.1 mm) - Fig. 17
IMPORTANT: Use only glass gobos on the rotating gobos wheels.
WARNING: Before using personalised gobos contact Clay Paky.
18
Gobo orientation - Fig. 18
The pictures shown the correct gobos orientation.
ALPHA BEAM 700
To determine which side of a godo is coated, hold an odject up to it. On
the uncoated side, there is a space between the object and its reflection.
17
Continue
➔
Page 18
Upper Side
19
WARNING: The use of
lcohol or any other
a
detergent could da mage the lens
Cleaning the Fresnel lens
Only use neutral soap and
ater to clean the Fresnel
w
lens, then dry it carefully with
a soft, non-abrasive cloth.
Parts requiring frequent cleaning.
Periodical cleaning
To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The
frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the
working environment (air humidity, presence of dust, salinity, etc.).
Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors and filters. It is recommended that the
projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations:
• General cleaning of internal parts.
• Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Clay Paky.
• General visual check of the internal components, cabling, mechanical parts, etc.
• Electrical, photometric and functional checks; eventual repairs.
- Fig. 19
ALPHA BEAM 700
18
Page 19
Lower Side
2
4
3
Upper Side
1
thermostat
20
Extraction of the effect modules: Preliminary operations - Fig. 20
ALPHA BEAM 700
19
Continue
➔
Page 20
Lower Side
3
1
Upper Side
2
Upper Side
8
4
Upper Side
5
21
Extraction of the effect modules - Fig. 21
IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged.
Insertion of the effect modules: Repeat the operations indicated in Fig. 20 and 21 in reverse order.
ALPHA BEAM 700
20
Page 21
405
(15.94")
385
(15.16")
390
(15.35")
220
(8.66")
635
(25.00")
435
(17,13")
505
(19,88")
5
20
(20,47")
TECHNICAL INFORMATION
Power supplies available
100-120V 50/60Hz
200-240V 50/60Hz
IP20 protection rating
• Protected against the entry of solid bodies larger
than 12mm (0.47”).
• No protection against the entry of liquids.
Input power
•
1050VA a 230V 50Hz.
CE Marking
In conformity with the European Union Low Voltage
Lamp
Discharge lamp.
Directive 2006/95/CE and Electromagnetic compatibility Directive 2004/108/CE.
• Type MSR Gold 700/2 Mini Fast Fit (L10098)
Cap PGJX28
-
- Colour temperature 7200 K
- Luminous flux 50000 lm
- Average life 750 h
afety Devices
S
• Bipolar circuit breaker with thermal protection.
• Automatic break in power supply in case of
overheating or failed operation of cooling system.
- Any working position
Cooling
Motors
Forced ventilation with axial fans.
19 stepper motors, operating with microsteps,
otally microprocessor controlled.
t
B
ody
• Aluminium structure with die-cast plastic cover.
Optical unit
•
Elliptic reflector with high luminous efficiency
• Two side handles for transportation.
• Device locking PAN and TILT mechanisms for
transportation and maintenance.
Channels
Max 26 control channels.
Working position
Functioning in any position.
Inputs
•
DMX 512
Weight
• about 20.80 Kg (45lbs 12ozs).
Movable body
•
Movement by means of two stepper motors, controlled by microprocessor.
•
Automatic repositioning of PAN and TILT after
accidental movement not controlled by control
unit.
• Travel:
- PAN = 540°
- TILT = 250°
• Maximum speeds:
- PAN = 3.20 (Normal) / 2.90 (Fast)
- TILT = 1.89 (normal) / 1.75 (Fast)
• Resolution:
- PAN = 2.11°
- PAN FINE = 0.008°
- TILT = 0.98°
- TILT FINE = 0.004°
ALPHA BEAM 700
THE PROJECTOR WILL NOT SWITCH ON
ELECTRONICS NON-OPERATIONAL
DEFECTIVE PROJECTION
REDUCED LUMINOSITY
POSSIBLE CAUSESCHECKS AND REMEDIES
No mains supply.
Lamp exhausted or defective.
Signal transmission cable faulty or disconnected.
Incorrect addressing.
Fault in the electronic circuits.
Lenses or reflector broken
Dust or grease deposited.
CAUSE AND SOLUTION OF PROBLEMS
PROBLEMS
Check the power supply voltage.
Replace the lamp. (See instructions).
Replace the cables.
Check addresses (see instructions).
Call an authorised technician.
Call an authorised technician.
Clean (see instructions).
21
Page 22
ALPHA BEAM 700
CHANNEL FUNCTION
CHANNEL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
STANDARDVECTOR
CYAN
MAGENTA
YELLOW
COLOUR WHEEL
STOP / STROBE
DIMMER
DIMMER FINE
IRIS
STATIC GOBO CHANGE
ROTATING GOBO CHANGE
GOBO ROTATION
PRISM INSERTION
PRISM ROTATION
FROST
CHANNEL MODE
CYAN
MAGENTA
YELLOW
COLOUR WHEEL
STOP / STROBE
DIMMER
DIMMER FINE
IRIS
STATIC GOBO CHANGE
ROTATING GOBO CHANGE
GOBO ROTATION
PRISM INSERTION
PRISM ROTATION
FROST
15
16
17
18
19
20
21
22
23
24
25
26
FOCUS
PAN
PAN FINE
TILT
TILT FINE
FUNCTION
RESET
LAMP CONTROL (with Option "Lamp Dmx" ON)
FOCUS
PAN
PAN FINE
TILT
TILT FINE
FUNCTION
RESET
LAMP CONTROL (with Option "Lamp Dmx" ON)
PAN - TILT TIME
COLOUR TIME
BEAM TIME
GOBO TIME
ALPHA BEAM 700
22
Page 23
BIT%EFFECT
255100
COLOUR EXCLUDED
00.0
COLOUR INSERTED
CHANNEL 1
CYAN
CHANNEL 2
MAGENTA
CHANNEL 3
YELLOW
B
IT
%
EFFECT
255100
COLOUR INSERTED
00.0
COLOUR EXCLUDED
CHANNEL 1
CYAN
CHANNEL 2
MAGENTA
CHANNEL 3
YELLOW
BIT%EFFECT
255100
FAST ROTATION (160 rpm)
128
127
120
1
12
105
97
90
82
7
5
67
60
52
45
37
30
22
15
8
0
50.0
49.7
47.0
4
4.0
41.2
38.0
35.0
32.0
2
9.5
26.2
23.7
20.5
17.5
14.2
11.7
8.7
6.0
3.2
0.0
SLOW ROTATION (0.2 rpm)
BLUE + WHITE
BLUE
ORANGE + BLUE
ORANGE
AQUAMARINE + ORANGE
A
QUAMARINE
GREEN + AQUAMARINE
GREEN
CTO 2500 + GREEN
CTO 2500
CTO 3200 + CTO 2500
CTO 3200
CTB+ CTO 3200
CTB
RED + CTB
RED
WHITE + RED
WHITE
MACRO
BIT%EFFECT
252 - 255 98.7 - 100
OPEN
0 - 30.0 - 1.2
CLOSED
213 - 225 83.7 - 88.2
RANDOM SLOW STROBE
41.7
SLOW STROBE (1 flash/sec)
10340.5
FAST STROBE (12 flash/sec )
104 - 107 41.0 - 42.0
OPEN
10842.5
SLOW PULSATION
208 - 212 81.7 - 83.2
OPEN
226 - 238 88.7 - 93.2
RANDOM MEDIUM S TROBE
239 - 251 93.7 - 98.2
RANDOM FAST STROBE
20781.2
FAST PULSATION
BIT%EFFECT
255100
00.0
B
IT
%
EFFECT
255100
00.0
00.0
MINIMUM APERTURE
252 - 255 98.7 - 100
MAXIMUM APERTURE
BIT%EFFECT
25198.2
FAST PULSATION, FAST CLOSING
21283.2
SLOW PULSATION, FAST CLOSING
2
1183
FAST PULSATION, FAST OPENING
17267.5
SLOW PULSATION, FAST OPENING
1
7167.0
F
AST PULSATION
13251.7
SLOW PULSATION
128 - 131 50.0 - 51.2
MAXIMUM APERTURE
MACRO
OTE: On conclusion of resetting in case of absence of DMX signal, Pan & Tilt move to the "Home" position (Pan 50% - Tilt 50%) all the others channels stay at 0%.
N
DIMMER - channel 6
• COLOUR MIXING - channel 1 - 2 - 3
peration with option color mixing: RGB
O
IMPORTANT: The lamp dim to half power 1 second after all the 3 channels stay at 0%
•
he lamp is linearly dimmed from full power to half power electronicaly and
T
mechanically from half power to off.
level. The lamp goes back to full power when the channels level is put higher than 0%.
peration with option color mixing: CMY
O
• DIMMER FINE - channel 7
IMPORTANT: The lamp dim to half power 1 second after all the 3 channels stay at 100%
level. The lamp goes back to full power when the channels level is put lower than 100%.
• COLOUR WHEEL - channel 4
• STOP / STROBE - channel 5
IMPORTANT: The lamp dim to half power 1 second after the channel stay at 0%
level. The lamp goes back to full power when the channel level is put higher than 0%.
ALPHA BEAM 700
• IRIS - channel 8
23
Continue
➔
Page 24
STOP
FAS T ROTATION (120 rpm)
SLOW ROTATION (3 rph)
SLOW ROTATION (3 rph)
FAS T ROTATION (120 rpm)
BIT%EFFECT
191 - 192 74.7 - 75.0
255100
19375.5
19074.2
12850.0
STOP
540°
360°
0°
POSITION 540°12749.7
POSITION 450°
10541.7
POSITION 360°
8433.0
POSITION 270°
6324.7
POSITION 180°
4216.2
00.0
POSITION 0°
POSITION 90°
218.2
BIT%EFFECT
12850.0
PRISM EXCLUDED
00.0
255100
PRISM INSERTED
12749.7
00.0
0° POSITIO N
218.2
90° POSITIO N
4216.2
180° POSITIO N
6324.7
270° POSITIO N
8433.0
360° POSITIO N
10541.7
450° POSITIO N
1
2749.7
540° POSIT ION
STOP
540°
3
60°
0°
2
55100
FAS T ROTATION (180 rpm)
1
9375.5
SLOW ROTATION (2.2 rph)
191 - 192 74.7 - 75.0
STOP
19074.2
SLOW ROTATION (2.2 rph)
BIT%EFFECT
1
2850.0
FAS T ROTATION (180 rpm)
STATIC GOBO CHANGE - channel 9
G
OBO 7 SHAKE, FAST SPEED
GOBO 7 SHAKE, SLOW SPEED
GOBO 6 SHAKE, FAST SPEED
GOBO 6 SHAKE, SLOW SPEED
GOBO 5 SHAKE, FAST SPEED
GOBO 5 SHAKE, SLOW SPEED
GOBO 4 SHAKE, FAST SPEED
G
OBO 4 SHAKE, SLOW SPEED
GOBO 3 SHAKE, FAST SPEED
GOBO 3 SHAKE, SLOW SPEED
GOBO 2 SHAKE, FAST SPEED
G
OBO 2 SHAKE, SLOW SPEED
FAST ROTATION (100 rpm)
SLOW ROTATION (5 rpm)
STOP
SLOW ROTATION (5 rpm)
F
AST ROTATION (100 rpm)
GOBO 8
GOBO 7
GOBO 6
G
OBO 5
GOBO 4
GOBO 3
GOBO 2
GOBO 1
WHITE
BIT%EFFECT
255
2
40
2
39
224
223
208
2
07
192
191
176
175
1
60
159
118
114 - 117
113
7
2
64 - 71
56 - 63
48 - 55
40 - 47
3
2 - 39
24 - 31
16 - 23
8 - 15
0 - 7
100
9
4.0
9
3.7
88.0
87.5
81.7
8
1.2
75.0
74.7
69.0
68.7
6
3.0
62.5
46.2
44.7 - 46.0
44.2
2
8.2
25.0 - 28.0
22.0 - 24.7
18.7 - 21.7
15.5 - 18.2
1
2.5 - 15.0
9.5 - 12.0
6.2 - 9.0
3.2 - 6.0
0 - 3.0
MACRO
130
114-129
98-113
82-97
65-81
49-64
33-48
17-32
0-16
MACRO
GOBO 7 SHAKE, FAST SPEED
GOBO 7 SHAKE, SLOW SPEED
GOBO 6 SHAKE, FAST SPEED
GOBO 6 SHAKE, SLOW SPEED
GOBO 5 SHAKE, FAST SPEED
GOBO 5 SHAKE, SLOW SPEED
GOBO 4 SHAKE, FAST SPEED
GOBO 4 SHAKE, SLOW SPEED
G
OBO 3 SHAKE, FAST SPEED
GOBO 3 SHAKE, SLOW SPEED
GOBO 2 SHAKE, FAST SPEED
GOBO 2 SHAKE, SLOW SPEED
GOBO 1 SHAKE, FAST SPEED
B
IT%EFFECT
255
238
237
220
219
202
201
184
183
166
165
148
147
100
93.2
93.0
86.2
86.0
79.0
78.7
72.0
71.7
65.0
64.7
58.0
57.5
51
44.7-50.5
38.2-44.2
32.0-38.0
25.5-31.7
19.0-25.0
13.0-18.7
6-7-12.5
0.0-6.2
GOBO 1 SHAKE, SLOW SPEED
GOBO 7
GOBO 6
GOBO 5
GOBO 4
GOBO 3
GOBO 2
GOBO 1
WHITE
•
GOBO ROTATION - channel 11
•
PRISM INSERTION - channel 12
•
• ROTATING GOBO CHANGE - channel 10
ALPHA BEAM 700
• PRISM ROTATION - channel 13
24
Page 25
FROST - channel 14
BIT%EFFECT
255100
DISTANT
00.0
N
EAR
BIT%EFFECT
255100
FROST INSERTED
00.0
FROST EXCLUDED
B
IT
%
255100
00.0
BIT
%
255100
00.0
BIT
%
255100
00.0
B
IT
%
255100
00.0
BIT
%
255100
12850.0
00.0
SE
TX
SEL
DMX
S
E
TX
SEL
DMX
SE
TX
SEL
DMX
BIT
%
255100
12850.0
00.0
E
E
E
•
PAN FINE - channel 17
•
Operation with option InvertPan
(Tilt conventionally represented at 14% and option Invert TiltGOff)
G
Off
• FOCUS - channel 15
• PAN - channel 16
Operation with option InvertPan
(Tilt conventionally represented at 14% and option Invert TiltGOff)
G
Off
peration with option InvertPan
O
(Tilt conventionally represented at 14% and option Invert Tilt
G
n
O
G
• TILT - channel 18
Operation with option Invert TiltGOff
(Pan conventionally represented at 0% and option Invert PanGOff)
Off)
Operation with option InvertPanGOn
(Tilt conventionally represented at 14% and option Invert Tilt
ALPHA BEAM 700
G
Off)
Operation with option Invert TiltGOn
(Pan conventionally represented at 0% and option Invert Pan
25
G
Off)
Continue
➔
Page 26
LAMP ON (FULL POWER)
LAMP ON (FULL POWER)
BIT%EFFECT
255100
18070.5
00.0
10139.5
10039.0
LAMP OFF
17970.0
2610.0
L
AMP OFF
259.7
UNUSED RANGE
Lamp ignition after 5 s
in full power levels.
Lamp switch off passing
throug the unused
range and staying 5 s in
Lamp OFF levels.