Class1 ITL Mini Remote Driver 112648 User Manual

Intelli-Tank Mini Remote Driver
Quick Manual
UNIT SPECIFICATIONS
1. Unit P.N. 112082.
2. System Voltage 9-32 volts.
INSTALLATION
WIRING Mating Connector: AMP 794821-1
Seal: AMP 794772-8 Wire Seal: AMP 794758-1 Terminals: AMP 770988-1 (Optional Wiring Pigtail # 112646)
Pin Description
1. Ground
2. Output 1
3. Output 2
4. Output 3
5. Data Input
6. Data Reference
7. Output 4
8. Power
1 Page Manual P.N. 112648 2-23-2005
UNIT OPERATION The unit is a slave for the Class1 ITL 4 or 5 light
tank level gauge. It will drive 4 external lights up to .5 amps a piece or for higher current lights a relay must be used.
During power up the unit will cycle on each output starting with output 1. The unit will then show current tank level information.
Wiring Diagram Example.