Class1 Intelli Tank Quick Calibration User Manual

Intelli-Tank Display
Quick Manual
INSTALLATION
Ensure the unit is mounted with the TOP situated up before applying the label to the display.
WIRING
114356.
Master – Only pins 1, 2, 6, 7, 8 are required for a system that doesn’t use any remote units. Pin 4 must be used if remote units are part of the system, and pin 3 should be used if the display dimming feature is used.
Remote – Only pins 1, 2, 4 are required for a remote unit. Pin 3 should be used if the display dimming feature is used. Pin 4
of the Master and Remote units must be all tied together.
PRESSURE TRANSDUCER MOUNTING
The top two LEDs will light when the LEFT magnetic switch is activated.
The bottom LED will light when the RIGHT magnetic switch is activated.
1 POINT CALIBRATION
A magnet is required to activate the magnetic switches. Each of the magnetic switch activations must occur within 2 seconds of the last or the password will be reset.
1. Make certain the tank is FULL. Enter the password RLLR LRRL. The unit will respond by flashing the top LED twice. The unit will then start to normal operation by displaying FULL (all LEDs on).
2 POINT CALIBRATION
A magnet is required to activate the magnetic switches. Each of the magnetic switch activations must occur within 2 seconds of the last or the password will be reset.
1. Enter the password RLLR LLRL. The unit will respond by flashing the two center LEDs twice. The unit will then begin cascading (drip) all four LEDs.
2. Make certain that the tank is EMPTY and then activate the RIGHT switch to store that point. The unit will flash the top LED and then turn on all four LEDs.
3. Fill the tank and then activate the RIGHT switch. The unit will respond by flashing the top LED then lighting the two center LEDs and then reverting to normal operation by displaying FULL (all LEDs on).
CONFIGURING DIM SETTING
Use a magnet and enter the dim level configuration password
RLLR LLLR.
All LEDs will turn on at the last set dim level. Activate the RIGHT switch to change the brightness. (Releasing the RIGHT switch and then reactivating will change the direction of the brightness.) Activate the LEFT switch when the desired level is attained.
OPERATION
During power up the display will individually cycle on each LED starting with the bottom LED. The unit will then show current tank level information.
Mount the transducer vertically to insure an accurate reading.
MAGNETIC SWITCH ACTIVATION
Magnetic switch locator.
DRIP = cascades from top (LED 4) to bottom (LED 1), pauses, and repeats.
For a detailed operation and troubleshooting
manual (p/n 114356) visit www.Class1.com
Manual PN 109395 Rev050906