Please read theentire instruction manual before using theproduct and then save it for
future reference. We reserve theright for any errors in text or images and any necessary changes made to technical data. If you have any questions concerning technical
problems please contact our Customer Services.
Safety
Permanent installation should only be performed by anauthorised electrician.
• Never connect thefan to awall outlet. It must be permanently installed onto theceiling.
• Minimum distance between thefan blades and floor: 2.3 metres. Thechosen
fastening point must have aminimum weight bearing capacity of 100 kg in order
to support theweight of thefan.
• Anall-pole switch, with aminimum of 3 mm between terminal connections must
be connected onto thefixed incoming mains lead.
• Only use bulbs (max 60 W) that are designed to be used in theceiling fan’s E14 lamp base.
• Turn off thefan before servicing or cleaning.
• Therequired electrical installation must be compliant to any local rules and regulations.
• Thefan must be protectively earthed in order to avoid possible electrocution risks.
• Thefan must not be installed in humid or wet environments.
• Be very careful when working close to therotating fan blades.
• Theproduct may be used by children who are 8 years and above and by persons
with reduced physical, sensory or mental capability or lack of experience and
knowledge provided they have been given supervision or instruction concerning
use of thesafe use of theproduct and understand thehazards involved.
• Never let children play with theceiling fan.
• Cleaning and user maintenance shall not be made by children without supervision.
• For indoor use only.
English
Warning symbol
>2.3 m
Warning: Minimum distance between thefan blades and floor:
2.3 metres. Risk of personal injury!
3
English
Product description
7
6
1. Fan speed pull-chain
2. Lamp diffuser
89
1345
2
3.
4.
5. Lamp housing
6. Blade arm brackets (×5)
7. Fan blades (×5)
8. Motor housing
9. Ceiling rose
10. Retaining screws
11. Hook
12. Ceiling mounting bracket
Rotational direction switch
Light pull-chain
10
11
10
12
4
Installation/Mounting
Warning: Make sure that anall-pole switch is connected to theincoming mains lead.
Warning: Make sure that theall-pole switch is turned off before beginning installation.
Note: Have someone assist you during installation.
1. Open thebox and remove thefan and its parts. Check that all theparts are present.
2. Screw theceiling rose (9) onto themotor
housing (8), using theincluded screws and
washers (shown by the arrows) that are
pre-mounted to themotor housing.
English
9
8
3. Flip thefan over so that thelamp housing is
facing upwards. Screw thefan blade brackets
(6) onto themotor’s drive disc, in thefollowing
order: Rubber washer (pre-mounted), blade
bracket, washer and screw. Use thescrews
and washers that are pre-mounted onto
thelamp housing (shown by the arrows).
4. Screw thefan blades (7) onto thefan brackets.
Thefan blade’s screws and washers and pullchains (1 and 4) come in aplastic bag.
5. Screw theceiling mounting bracket (12) into
theceiling , making sure that theincoming
mains lead enters through thebracket’s
centre hole. Use appropriate screws and
flat/spring washers for fastening. Make sure
that themounting surface and screws have
sufficient weight bearing capacity for theweight
of thefan before installing theceiling mounting
bracket. Make sure there are no hidden
electrical cables or pipes in theceiling before
drilling any mounting holes.
6. Connect theelectrical wires from theincoming
mains conduit to themounting bracket’s
terminal block (10). Connect theblue wire to
theN terminal thebrown wire to theL terminal
and theyellow/green wire to the
terminal.
67
5
English
7. Hang thefan onto theceiling bracket’s resting
hook. Theceiling mounting bracket’s resting
hook (11) is used to hang thefan during
mounting or service. Theceiling rose (9) has
acorresponding eyelet used for hanging
thefan unit onto.
9. Unhook thefan from thehook.
Align theceiling rose cut-outs so that they
slot under theceiling bracket’s (12) protruding
screws and washers, then ceiling rose twist it
until it hooks and locks into place.
10. Screw thefan securely onto theceiling bracket
using the4 screws and washers (10).
11. Screw in anappropriate bulb and refit thelamp
diffuser.
12. Clip thepull-chains (1 and 4) onto theball chain
extensions protruding from thelamp housing.
11
Operating instructions
Rotation direction
• Warning: Turn off thefan using theall-pole switch.
• Set therotation direction using therotational direction switch (3).
• Winter mode: Slide theswitch to theright for moving warm air from theceiling to
floor level.
• Summer mode: Slide theswitch to theleft to recirculate theambient air for
maximum cooling.
• Turn on theall-pole switch.
6
Pull-chain functions: ON/Speed selection and OFF
Use thepull-chain (1) to select thedesired function.
1 pull: On/high speed – 2 pulls: Normal speed– 3 pulls: Low speed – 4 pulls: OFF.
Switching thelamp on and off
Use thepull-chain (4) to turn thelamp on or off.
Responsible disposal
This symbol indicates that this product should not be disposed of with
general household waste. This applies throughout theentire EU. In order
to prevent any harm to theenvironment or health hazards caused by
incorrect waste disposal, theproduct must be handed in for recycling
so that thematerial can be disposed of in aresponsible manner. When
recycling your product, take it to your local collection facility or contact
theplace of purchase. They will ensure that theproduct is disposed of
in anenvironmentally sound manner.
Specifications
Bulb 220–240 V AC, E14, max 1 × 60 W
Rated voltage 220–240 V AC, 50 Hz
Fan motor output Max 60 W
English
7
Takfläkt
Art.nr 36-6153 Modell 4057401112
Läs igenom hela bruksanvisningen före användning och spara den sedan för framtida bruk.
Vi reserverar oss för ev. text- och bildfel samt ändringar av tekniska data.
Vid tekniska problem eller andra frågor, kontakta vår kundtjänst.
Säkerhet
Installation ska utföras av behörig elinstallatör.
Svenska
• Anslut aldrig fläkten till ett vägguttag, den måste anslutas till fast elinstallation i taket.
• Minsta avstånd mellan fläktens blad och golv: 2,3 meter. Upphängningspunkten
• En allpolig strömbrytare, med ett minsta avstånd på 3 mm mellan kontaktytorna
• Använd endast en ljuskälla (max 60 W) som är avsedd för att monteras
• Stäng av fläkten innan service och rengöring.
• Elinstallationen måste utföras enligt lokala regler och förordningar.
• Fläkten måste skyddsjordas för att undvika risk för elektrisk chock.
• Fläkten får inte monteras i fuktiga eller våta utrymmen.
• Var försiktig om du arbetar i närheten av de roterande bladen.
• Takfläkten får användas av barn från 8 år och av personer med någon form av
• Låt aldrig barn leka med takfläkten.
• Rengöring och skötsel får inte utföras av barn utan tillsyn.
• Endast för användning inomhus.
där fläkten är fäst i taket måste tåla en belastning på minst 100 kg.
måste installeras på den fasta inkommande anslutningskabeln.
i takfläktens E14-sockel.
funktionsnedsättning, brist på erfarenhet eller kunskap som skulle kunna äventyra
säkerheten, om de har fått instruktioner om hur den på ett säkert sätt ska
användas och förstår faror och risker som kan uppkomma.
Varningssymbol
>2.3 m
Varning! Minsta avstånd mellan fläktens blad och golvet: 2,3 meter.
Risk för personskada!
8
Produktbeskrivning
89
7
6
1. Kedja för inställning av fläktens varvtal
2. Lampkupa
Svenska
1345
2
3.
4.
5. Armaturhus
6. Fäste till fläktblad (×5)
7. Fläktblad (×5)
8. Motorkåpa
9. Övre kåpa
10. Fästskruvar
11. Krok
12. Upphängningskonsol
Inställning av rotationsriktning
Kedja för att tända/släcka belysningen
10
11
10
12
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.