SWING ARM MAGNIFYING LAMP
MODEL No: SAM 100
Part No: 5460530
OPERATING & MAINTENANCE
INSTRUCTIONS
LS0514

Thank you for purchasing your new CLARKE
swing arm magnifying lamp.
Before using this product, read this leaflet
thoroughly, and follow the instructions
carefully, you can then look forward to it
giving long and reliable service.
GUARANTEE
This CLARKE product is guaranteed against
faulty manufacture for a period of 12
months from the date of purchase. Your
receipt is required as proof of purchase.
This guarantee is invalid if the product is
found to have been abused, or tampered
with in any way, or not used for the
purpose for which it was intended.
Faulty goods should be returned to their
place of purchase, no product can be
returned to us without prior permission. This
guarantee in no way effects your statutory
rights
ENVIRONMENTAL RECYCLING
POLICY
Through purchase of this product, the
customer is taking on the obligation to
deal with the WEEE in accordance with the
WEEE regulations in relation to the
treatment, recycling & recovery and
environmentally sound disposal of the
WEEE.
In effect, this means that this product must not be
disposed of with general household waste. It must
be disposed of according to the laws governing
Waste Electrical and Electronic Equipment
(WEEE) at a recognised disposal facility.
ELECTRICAL CONNECTIONS
This product is supplied with a 13 amp, BS
1363 plug, for connection to a domestic
240 Volt (50Hz) electrical supply. Should it
be necessary to renew the plug at any
time, ensure the replacement is of identical
specification.
IMPORTANT: The wires in the mains lead are
coloured in accordance with the following
code:
Green & Yellow -Earth, Blue - Neutral
Brown - Live
As the colours of the flexible cord of this
appliance may not correspond with the
coloured markings identifying terminals in
your plug proceed as follows:
Connect GREEN & YELLOW
cable to terminal marked with a
letter “E” or Earth symbol “
or coloured GREEN or GREEN &
YELLOW.
Connect BROWN cable to
terminal marked with a letter “L”
or coloured RED.
Connect BLUE cable to terminal
marked with a letter “N” or
coloured BLACK.
In the event that this product is fitted with a
plug which is moulded onto the electric
cable (i.e.. non-rewirable) please note:
1. The plug must be thrown away if it is cut
from the electric cable. There is a
danger of electric shock if it is then
inserted into a socket outlet.
2. Never use the plug without the fuse
cover fitted.
3. Should you wish to replace a
detachable fuse carrier, ensure that the
correct replacement is used (as
indicated by marking or colour code).
4. Replacement fuse covers can be
obtained from your local dealer or
most electrical stockists. 5. If the mains
cable becomes frayed or damaged in
any way, do not use the lamp until it
has been replaced. Contact your local
dealer for a replacement part.
Fuse Rating. The fuse in the plug is 3 amps,
and must be replaced with one of the
same rating and ASTA approved to BS
1362.
2
”

ASSEMBLY AND OPERATION
PARTS LIST & DIAGRAM
Your magnifying lamp is in two parts, the
lamp with adjustable arms, and the clamp
assembly (item 7), which comprises a “g”
clamp on to which is mounted a holder for
accommodating the spigot on the
underside of the lamp base. The holder
may be rotated by up to 180°, by slackening the knob (item 11), and re-tightening
where required. This allows the lamp to be
upright, with the “g” clamp mounted on
surfaces at varying angles up to the
vertical.
SETTING UP
The lamp is designed so that it will remain
stable in any desired position. When
installing your lamp, first slacken off the
pivot pinch bolts, using the large adjuster
knobs (item 6), to allow the arms to move
freely. Tighten the pinch bolts so that they
are firm, but do not over tighten. When the
pivots are correctly tightened, the lamp
should be capable of maintaining stability
in any position, without the need for
readjustment.
MAINTENANCE
The unit requires little maintenance, and is limited
to changing the tube when necessary, and
cleaning the lens.
Liquid glass cleaner may be used to clean the lens,
used sparingly and with a soft dry cloth. Do not
wet the tube or electrical connections.
To change the tube, slacken off two of the tubes’
spring retaining clips (item 13), allowing the tube to
be withdrawn. Pull off the 4 pin plug, and connect
it on the new tube. Place the tube on its seating,
ensuring the wires connected to the plug are
pushed back behind the tube shield. They should
not be allowed to hang free, alongside or resting
against the tube. Be careful not to force the plug
as the pins are offset to prevent the plug from
being connected at 90° to its’ correct position.
Finally, retighten the spring retaining clip screws.
Replacement tube - domestic florescent, 22 watt
210 o/d.
IMPORTANT: You should always switch the lamp
OFF, and unplug from the mains before
changing the tube or cleaning the lens.
Item Description Part No.
1 Cover SAM 10001
2 Lens 5" SAM 10002
3 Tube 5460535
4 Switch Assembly SAM 10003
5 Transformer SAM 10004
6 Adjuster Knob N/A
7 ‘G’ Clamp SAM 10007
8 Stand SAM 10008
9 Base SAM 10009
10 Transformer Cover SAM 10010
1 1 Clamp Screw Knob N/A
12 Spring N/A
3