Thank you for purchasing this CLARKE 800W Inverter Generator.
Before attempting to use this product, please read this manual thoroughly and
follow the instructions carefully. In doing so you will ensure the safety of yourself
and that of others around you, and you can look forward to your purchase
giving you long and satisfactory service.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt which will be
required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for the purpose for which it was
intended.
Faulty goods should be returned to their place of purchase, no product can
be returned to us without prior permission.
This guarantee does not effect your statutory rights.
ENVIRONMENTAL RECYCLING POLICY
Through purchase of this product, the customer is taking on the
obligation to deal with the WEEE in accordance with the WEEE
regulations in relation to the treatment, recycling & recovery and
environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal
facility.
WARNING: IT IS ADVISABLE TO PROPERLY EARTH YOUR GENERATOR
BEFORE STARTING USING A WIRE AND A SMALL METAL EARTH SPIKE. THE
WIRE AND EARTH SPIKE ARE NOT SUPPLIED WITH THE UNIT.
An earth spike and cable can be purchased at your local camping supplier,
or alternatively an earth spike can be made, and it is suggested you get
advice from a qualified electrician.
To make a spike use a copper tube or copper rod 12mm diameter, a minimum
length of 200mm and with an M6 machine screw one end.
The cable used should be a maximum length of 1 metre and a minimum of
2
1.0mm
Attach the cable to the generator at
the earth point (shown on the right).
Connect the other end to the spike
between a flat washer and the
copper rod with a lock washer under
the head of the M6 machine screw in
a similar fashion to the earth point
screw on the generator.
When pushing the spike into the
ground the generator must not be
running and it is suggested that the spike is pushed into the ground by at least
100 mm.
Earthing of generators is covered in BS7430:2011, If you have any doubts
about this subject consult a qualified electrician.
5. If the air filter is damaged contact
the Clark
department for a replacement.
• If the filter is dirty, wash it in a
e spare parts
solution of warm water and
mild detergent and rinse
thoroughly. Leave the filter to
dry completely. Once it is dry
immerse the filter in clean
engine oil and squeeze the filter to remove excess oil.
WARNING: DO NOT USE FLAMMABLE SOLVENTS OR PETROL TO CLEAN THE
AIR FILTER.
6. Replace the filter into its original position and rep
lace and secure the air
filter cover then replace the side maintenance panel.
WARNING: MAKE SURE THERE IS FUEL IN THE TANK WHEN USING THE
GENERATOR. RUNNING OUT OF FUEL OR STOPPING THE ENGINE
SUDDENLY WITH A LOAD CONNECTED COULD CAUSE SERIOUS DAMAGE.
1.
To check the fuel level, open the
fuel filler cap.
2. Slowly add fuel to the fuel tank
(maximum 2.1 litres)
•
Do not overfill the fuel tank.
3. Replace the fuel filler cap
secur
ly.
e
WARNING: FUEL IS HIGHLY FLAMMABLE AND POISONOUS.
WARNING: SEE “GENERAL SAFETY RULES” ON PAGE 4 AND READ THEM
CAREFULLY BEFORE REFUELING.
WARNING: DO NOT FILL ABOVE THE TOP OF THE FUEL FILTER OR IT MAY
OVERFLOW WHEN THE FUEL HEATS UP AND EXPANDS.
WARNING: WIPE UP ANY SPILLED FUEL IMMEDIATELY.
WARNING: AFTER REFUELING, MAKE SURE THE FUEL FILLER CAP IS
TIGHTENED SECURELY.
RECOMMENDED FUEL
Your generator has been designed to use regular unleaded petrol with a
octane number of 86 or higher.
6. If this is the first time you are using
the generator or if the generator
had run out of fuel the last time
you used it, pump the primer bulb
a minimum of 6 times to introduce
fuel into the carburetter.
Hold the generator handle firmly
7.
and pull the starting handle lightly
until you start to feel resistance
and then pull up sharply to start
the engine.
NOTE: You may have to do this
more than once.
.
WARNING: ONCE THE GENERATOR HAS STARTED, RELEASE THE STARTING
HANDLE SLOWLY TO AVOID INJURY/DAMAGE AS IT WHIPS BACK.
NOTE: When you first start the generator, the overload indicator may light
up for a few seconds, this is normal. If the overload indicator is still
lit after 5 seconds, stop the engine and contact your Clarke
dealer.
Once the engine has warmed up,
8.
move the choke lever to the left,
to the “run” p
Recommended to minimize fuel
consumption and further reduce
noise levels when no load is applied
to the generator. Engine speed varies
with the load.
OFF:
The smart throttle system does not
operate.
CAUTION: THE ECONOMY CONTROL DOES NOT WORK EFFECTIVELY IF
THE ELECTRICAL APPLIANCE REQUIRES ‘BURSTS’ OF POWER.
CAUTION: TURN THE ECONOMY CONTROL FEATURE OFF WHEN
CONNECTING HIGH LOAD APPLIANCES OR WHEN CONNECTING TO THE
DC OUTPUT.
CONNECTING ELECTRICAL DEVICES
The generator can supply both 230V AC and 12V DC
AC POWER
Start the engine. See page 13.
1.
2. Make sure the appliance is turned
off before
generator.
3. Connect the appliance (max
load 800W) to the generator
connecting it to the
.
CAUTION: MAKE SURE THAT THE APPLIANCE BEING CONNECTED IS IN
GOOD WORKING ORDER, IF IT BEGINS TO ACT ABNORMALLY OR STOPS
SUDDENLY, DISCONNECT IT FROM THE GENERATOR
CAUTION: MAKE SURE THE APPLIANCE DOES NOT EXCEED THE MAXIMUM
RATED LOAD FOR THE GENERATOR.
CAUTION: ANY DEVICE WHICH CONTAINS AN INDUCTIVE LOAD E.G.
DEVICES THAT CONTAIN A MOTOR MAY REQUIRE MORE CURRENT ON
STARTUP.
CAUTION: PROLONGED EXPOSURE TO USED ENGINE OIL IS DANGEROUS,
ALWAYS WASH YOUR HANDS THOROUGHLY AFTER HANDLING USED
ENGINE OIL.
1. Remove the maintenance panel
shown on the right.
Turn the oil filler cap anti-
2.
clockwise and remove from the oil
tank.
3. Tilt the generator to allow the oil
to drain out of the oil reservoir into
a suitable container.
NOTE: You may need assistance
with this step as the
generator is heavy.
4.
Fill the oil reservoir with fresh oil.
• Do not fill above the max level
mark (
0.3 litres)
• We recommend the use of
SAE30 oil in this generator.
(Clarke part number 3050852)
5. Replace the oil filler cap and
ma
intenance panel.
ENVIRONMENTAL PROTECTION
One of the most damaging sources of pollution is oil. Do not throw away used
engine oil in with your domestic waste or down drains and sinks. Place it in a
leak proof container and dispose of it according to local regulations.