Thank you for purchasing this CLARKE Submersible Dirty Water Pump.
This pump is NOT designed for pumping slurry, sludge, mud or heavily polluted
water, or any water containing chemicals or other acidic contaminants
including salt water.
The DWP100A and DWP150A have the ability to pump solids in suspension as
large as 6.8 mm.
The DWP200A has the ability to pump solids in suspension as large as 7 mm.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt which will be
required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for the purpose for which it was
intended.
Faulty goods should be returned to their place of purchase, no product can
be returned to us without prior permission.
This guarantee does not effect your statutory rights.
ENVIRONMENTAL RECYCLING POLICY
Through purchase of this product, the customer is taking on the
obligation to deal with the WEEE in accordance with the WEEE
regulations in relation to the treatment, recycling & recovery and
environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal
facility.
1. Read all instructions before use
and save these instructions for
future use.
2. An approved residual current
device (RCD) which has a
tripping current of less than 30mA
must be used for all operations.
3. The electrical supply must be the
same as that on the rating plate.
4. Always make sure that your
hands are dry when connecting
or disconnecting from the mains
supply.
5. Never pull the mains lead to
disconnect the pump from the
mains socket.
6. The mains plug must be kept
away from the water at all times.
7. Do not allow children or
unauthorised people to touch the
pump, cables or connections.
8. Disconnect the pump from the
mains supply when not in use.
9. If necessary have the pump
repaired by a qualified person.
10. Keep the mains lead away from
heat, oil and sharp edges.
11. If you have to use an extension
lead with this product, it must be
designed for outdoor use and
incorporate a cable suitable for
use with Class I appliances.
12. Disconnect the pump from the
electrical supply and wear gloves
during servicing or maintenance.
PUMP SPECIFIC
1. Do not pump explosive /
flammable liquids or chemicals.
2. Never allow the pump to run dry
or operate out of the water.
3. Submersible pumps should always
be submerged and stored
vertically.
4. Disconnect the pump from the
mains supply before placing it
into or removing it from the water.
5. Always check the plug, mains
cable and float switch cable for
damage before use.
6. Do not use the pump if
damaged. Refer to qualified
service personnel for repair.
7. Never carry the pump by the
power cable or float switch
always use the handle or a rope
tied securely to the handle.
8. Never insert your fingers into the
pump whilst it is connected to the
mains.
9. Never use the submersible pump
in a swimming pool when there
are people or animals in the pool.
10. Keep the pump clear of any
sediment by standing it on a
platform or brick or suspending it
at a suitable height.
11. Do not use the pump if the water
is liable to freeze, as this can
cause damage to the pump.
Remove the pump from the
water and store it in a frost free
location.
WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS
SUPPLY.
Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply
through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.
If the plug has to be changed because it is not suitable for your socket, or
because of damage, it must be removed and a replacement fitted, following
the wiring instructions shown below. The old plug must be discarded safely, as
insertion into a power socket could cause an electrical hazard
WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL BROWN = LIVE YELLOW AND GREEN = EARTH
If the colours of the wires in the power cable do not agree with the markings
on the plug.
• The BLUE wire must be
connected to the
terminal which is
marked N or coloured
black.
• The BROWN wire must
be connected to the
terminal which is
marked L or coloured
red.
• The YELLOW AND
GREEN wire must be
connected to the terminal which is marked E or or coloured green.
An approved Residual Current Device (RCD) which has a tripping current of
less than 30mA must be used.
If you are not sure, consult a qualified electrician. DO NOT try to do any
repairs.
OVERLOAD SWITCH
These pumps are fitted with a thermal overload switch. If the pump overheats
for any reason, it will automatically switch the pump OFF. Once the pump has
cooled (at least 5-10 minutes), the pump will automatically restart.
WARNING: BEFORE CHECKING THE CONDITION OF THE PUMP, ENSURE IT
IS UNPLUGGED FROM THE MAINS SUPPLY. IF THE UNIT IS HARD WIRED,
ENSURE THE CIRCUIT BREAKER IS OPEN.
This pump should require no maintenance other than regular cleaning.
If the pump starts to show signs of wear or damage, contact your CLARKE
dealer for advice.
CLEANING
1. Check the pump installation regularly to ensure the water inlet is clear of
leaves or other debris.
2. Take extra care to remove any debris from around the impeller.
NOTE: Do not attempt to repair the pump yourself. Repairs must be carried
out by your CLARKE dealer, or contact the CLARKE Service
Department.
STORAGE
When the pump is not being used for extended periods, clean and dry it
thoroughly and store it indoors. If the pump is left in water, it must be run at
least once a week to prevent it from seizing up.
If this does not solve your problem, please contact the Clarke service
department.
1. Make sure that the power is switched on.
2. Check fuse (consult an electrician if in doubt).
3. If extension lead is fitted, check connections (consult an
electrician if in doubt).
4. Internal thermal cut-out has not re-set. Leave for 5-10
minutes and try again.
5. The impeller may be jammed. Disconnect from the mains
supply and remove any objects that may be obstructing
the impeller.
6. Float switch may be jammed against side wall, or
prevented from moving.
7. Water level too low - float switch in OFF position - lift float
to check switch.
8. If the pump still fails to start, consult your CLARKE dealer
for advice.
1. Check that the inlet is not blocked.
2. Check that the discharge tube is not clogged or
obstructed.
3. The head may be too great, i.e. you are trying to lift the
water too great a distance for the pump to cope with.
(“Specifications” on page 7).
4. Air bubble in the pump, produced during the plunge.
Plunge the pump again, at an angle, and shake it whilst
lowering to remove any air trapped in the system.
5. Impeller may be damaged - Consult your CLARKE dealer.
1. Float switch may be prevented from moving to the fully
down position.
2. Float switch may be faulty. Consult your CLARKE dealer
for advice.
1. Thermal overload has operated. Leave for 5-10 minutes