This Ungo Pro Security system is warranted against defects in material and workmanship. The main unit is covered by this limited lifetime warranty. This Limited Lifetime Warranty applies to Ungo Pro Security systems that have been installed by an authorized Ungo Pro Security dealer. This warranty is to the Original Purchaser ("Owner") and to the original vehicle in which it was installed into. This warranty is not transferable to any subsequent owner(s) of the product(s).
WWaarrrraannttyy PPrrooggrraamm::
Main Unit Limited Lifetime Remote Controls One year from date of purchase Siren One year from date of purchase Shock Sensor One year from date of purchase LED One year from date of purchase Override Switch One year from date of purchase
The Warranty does not cover batteries or products deemed damaged through alterations or installation. It also does not cover products mishandled, misused, neglected, abused, water damaged, or with removed/altered serial numbers.
PROOF OF PURCHASE WILL BE REQUIRED FOR WARRANTY SERVICE OF THIS PRODUCT.
This warranty does not cover the costs incurred for removal or reinstallation of the main unit and/or any damage to the vehicle or the vehicle's electrical system.
The sole responsibility of Clarion Corporation of America ("Clarion") under this Warranty shall be limited to the repair or replacement of the product, at the sole discretion of Clarion.
If it becomes necessary to send the product or any defective part to Clarion, the product must be shipped in its original carton or equivalent carton, fully insured, with shipping charges prepaid. Clarion will not assume any responsibility for any loss or damage incurred in shipping.
ALL IMPLIED WARRANTIES EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW SHALL HAVE NO GREATER DURATION THAN THE WARRANTY PERIOD SET FORTH ABOVE. UNDER NO CIRCUMSTANCES SHALL CLARION CORPORATION BE LIABLE FOR ANY LOSS OR DAMAGE, DIRECT OR CONSEQUENTIAL, ARISING OUT OF THE USE OR INABILITY
ii
TO USE OF THE PRODUCT. BECAUSE SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR EXCLU­SIONS OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE THE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE.
Should you have any difficulties with the performance of this product during warranty, please call: 1-800-GO-CLARION or visit your local Ungo Pro Security dealer. You may also contact the National Service Manager at the following address below for additional service help you may need.
Clarion Corporation of America Attn: National Service Manager 661 W. Redondo Beach Blvd. Gardena, Ca 90247
1
table of contents
limited lifetime consumer warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i
standard remote configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
what is included . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
important information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
system maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
fcc/id notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
remote functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
using your system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
active arming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
passive arming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
remote sensor bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
arming while driving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
disarming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
silence alarm without disarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
disarming without a remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
silent mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
panic mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
override mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
false alarm prevention circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
arming diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
disarming diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
system status chirps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
table of zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
interpreting zone diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
anti-code grabbing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
high frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
individual remote recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
power-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
power saving mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
programming options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
installation options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
anti-carjacking system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
arming the anti-carjacking system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
anti-carjacking triggered sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
disarming the anti-carjacking system . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
glossary of terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
security & convenience expansions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
2
standard remote configuration
controls the Arm function.
controls the Disarm function.
controls Silent Arm/Disarm and an Auxiliary output.
controls the Panic function.
and pressed together control an Auxiliary output.
3
what is included
One control moduleA pair of four-button remotesA dual-stage shock sensor A six-tone programmable sirenThe blue status LED indicator lightA push-button override switchStarter kill ready circuitry (may require additional labor)External receiver/antenna
important information
Congratulations on the purchase of your state-of-the-art vehicle securi-
ty system. This system has been designed to provide years of trouble-
free operation. Due to the complexity of this system, it must be installed
by an authorized dealer only. Installation of this product by anyone other
than an authorized dealer voids the warranty.
This owner’s guide should help you to get the most out of your system.
Please take the time to read it prior to using the system.
4
system maintenance
The system requires no specific maintenance. Your remote control is
powered by a small, lightweight 3 volt lithium battery that will last
approximately one year under normal use. When the battery weakens,
operating range will be reduced and the LED on the remote will dim.
fcc/id notice
This device complies with Part 15 of FCC rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received,
including interference that may cause undesirable operation.
Changes or modifications not expressly approved by the party responsi-
ble for compliance could void the user's authority to operate this device.
remote functions
This system uses a computer-based learn routine to learn the remote
buttons. This makes it possible to assign any remote button to any sys-
tem function. The remote initially comes programmed with Standard
Configuration, but may also be customized by an authorized dealer. The
buttons in all of the instructions in this manual correspond to a
Standard Configuration remote.
5
standard configuration
Button
The arming function is controlled by pressing this button for one second.
Button
The disarming function is controlled by pressing this button for one second.
Button
Silent Arm/Disarm and an optional auxiliary function are controlled by
pressing this button. (Silent Arm/Disarm works by pressing this button
for less than one second before arming or disarming. An optional aux-
iliary function, such as trunk release, can be controlled by pressing this
button for 1.5 seconds.)
The auxiliary output controls __________________________.
Button
The panic feature is controlled by pressing this button for two seconds.
and Buttons
An optional auxiliary convenience or expansion function that you have added
to your system can be activated by pressing these buttons simultaneously.
The auxiliary output controls __________________________.
6
using your system
The buttons used in the instructions in this manual correspond to the
standard configuration. Remember, this is not the only way your
remote may be set up. It can be custom configured to meet your needs.
active arming
You can activate, or arm, the system by pressing on your remote for
one second. When the system arms, you will hear a short siren sound, or
chirp, and the parking lights will flash once. If the vehicle’s power door
locks have been connected to the system, the doors will lock.
While the system is armed, the status LED will flash approximately once
per second, indicating that the system is actively protecting your vehi-
cle. If you hear a second chirp after arming, and see the status LED
flashing in groups, refer to the Diagnostics section of this guide. This
extra chirp is notification of an open zone.
passive arming
The system also can be programmed to arm itself automatically (called
passive arming). If the system is programmed for passive arming, it will
automatically arm 30 seconds after the ignition is turned off and the
system "sees" you leave the vehicle by opening and closing a door.
Whenever the system is in its 30-second passive-arming countdown,
the status LED will flash twice as fast as it does when the system is
armed. The siren will chirp once 20 seconds after the last door has been
closed. The system is not actually armed at that point. The system arms
and the doors lock (if connected and programmed for passive locking)
at the 30 second mark, but the siren will not chirp. The early chirp pro-
7
vides you with a 10-second warning prior to arming.
When armed, your vehicle is protected as follows:
Light impacts will trigger a warning signal. When triggered, the
siren will chirp and the parking lights will flash for a few seconds.
Heavy impacts will trigger the system. The triggered sequence
is between 1-180 seconds of constant siren and flashing
parking lights.
If a door is opened, the system will immediately start chirping
the siren and flashing the parking lights. Three seconds later,
the siren output changes to a continuous blast. This progres-
sive response gives you time to disarm the system with your
remote if you inadvertently open the door while the system is
armed, while still providing an instant response (even if the
door is immediately closed).
Turning on the ignition key will trip the same two-stage
response as opening a door.
The optional starter kill prevents the vehicle’s starter from cranking.
nnoottee::
If any protected entry point (such as a door or a switch­protected trunk or hood) is open, the system will not passive­ly arm (unless forced passive arming is programmed on). See Programming Options section of this guide. Additionally, each time a protected entry is triggered during the arming countdown, the 30-second countdown starts over.
8
remote sensor bypass
Remote Sensor Bypass allows you to select which of the security sys-
tem's inputs or sensors will be active and which will be bypassed at the
time that the system is armed. (See the Table of Zones section of this
guide.) Pressing again within five seconds of arming the security
system will activate the Remote Sensor Bypass feature. Each time
is pressed again, a different security level is selected. The different secu-
rity levels can be selected as follows:
Press one time: The siren chirps once. The system is
armed.
Press a second time within five seconds: The siren chirps
twice followed by a long chirp. Zone 2 is now bypassed.
Press a third time within five seconds: The siren chirps
three times followed by a long chirp. Zone 4 is now bypassed.
Press a fourth time within five seconds: The siren chirps four
times followed by a long chirp. Zones 2 and 4 are now bypassed.
Press a fifth time within five seconds: The siren chirps
five times followed by a long chirp. All input zones, except
the ignition, are now bypassed.
Continued pressing of will begin the Remote Sensor
Bypass cycle over again.
nnoottee::
Remote Sensor Bypass only applies to a single arming cycle. Once the system is disarmed and then re-armed, all the zones will be active again.