Citronic DSM2-6mkII User Manual

DSM2-6mkII
DIGITAL SPEAKER MANAGEMENT
170.659UK
Features
96kHz sampling frequency, 32-bit A/D and D/A converter, 24-bit DSP processor Input channel: 6-band parametric EQ, Delay, Polarity Output channel: Signal select, 6-band parametric EQ, Gain, Delay, Polarity, Crossover, Limiter Built-in USB and RS485 com ports Program function, recall and copy 30 internal user programs Password protection
Introduction
Thank you for purchasing this high quality Citronic digital speaker management system. The aim of our audio processing range is to offer cost-effective, high performance sound sculpting tools for live sound reinforcement and installation applications. The Citronic DSM2-6 offers a comprehensive and professional speaker management solution delivering unsurpassed sound quality.
The DSM2-6 comprises a 2 input, 6 output digital sound processor with fully assignable high and low pass crossover filters on each output for low or high frequency outputs or in combination for mid frequency output. Each filter can be assigned as Butterworth, Linkwitz-Riley or Bessel type across various cut-off slopes to give ultimate flexibility.
Each input channel has gain and phase correction and 6 bands of independent parametric or shelving EQ to tailor the input tone.
Each output channel has 6 bands of independent parametric EQ for tone shaping and to compensate for room or speaker anomalies. Also, each output has time alignment delay and adjustable limiter to protect the outputs from overloading.
In addition to the user-friendly front panel menus, all functions may be manipulated and stored via USB using the included PC software. A graphic interface allows quick and easy adjustment of all the main parameters. Further slave DSM2-6 units can be linked via RS485 connection (RJ45)
Signal connection is XLR throughout, balanced or unbalanced and each output may be addressed from either input A or B or A+B combined.
The internal memory can store up to 30 user programs and each can be named for easy identification. Each can be recalled at will and the unit can be password protected to lock out the functions to unauthorized persons.
This unit has been built to Citronic’s exacting standards using high grade circuit boards and components housed in a heavy duty steel chassis casing to give long term, reliable service.
Installation
Set the DSM2-6 into a 1U space in a rack, ensuring enough depth to contain the unit and any connectors attached to it. Secure the front panel with rack screws and nuts to hold in place and stop the unit slipping. Plug the included power cable into the rear panel IEC connector and connect to the mains. Be sure to switch the DSM2-6 on before switching on the power amplifiers to avoid loud thumping sounds through the speakers and switch the amplifiers off before switching off the DSM2-6.
Connection to each channel is served by XLR for both inputs and outputs.
For balanced connections, follow the table below.
Connection
XLR connector
Hot (+)
Pin 2
Cold (-)
Pin 3
Earth
Pin 1
For unbalanced connections, follow the table below.
Connection
XLR connector
Signal (Hot)
Pin 2
Earth (Cold)
Pin 1 + 3
Applications
Use the DSM2-6 to control and distribute the signal to up to 6 amplifier channels driving different speaker arrays. A typical configuration with 2 subs, 2 mid/tops and 4 surround cabinets is shown below…