These operating instructions cover the following intruder system:

8EP 394 XR1G3 panel with built in keypad

For Clarity, the information given on setting the system, assume that all Programs use a timed or final door setting routine.

Tamper

Chime Omit Reset Prog

Set

Day

 

Unset system indications

Key

LED steady On indication

LED flashing indication

LED Off

Internal sound

Sound description

NOTE: In general a flat beep is

an indication of an incorrect key press.

External devices

Strobe

Bell

Unset system indications

An unset system will have both Day and Power indicators lit. This is a normal Day Power indication when the system is

disarmed.

Note: If the Power indicator goes off at any time then there is a mains supply failure at the security panel, consult your servicing organisation.

Set System indication

An active ‘Set’ system will have only the Power

Power indicator lit. This is an armed system indication.

4188-693 issue 1_8/01

1

Downloaded from: http://www.guardianalarms.net

Access codes

Operating instructions

Citadel XR1 G3 Intruder system

 

 

Contents

 

Unset system indications - - - - - - - - - - -

1

Set System indication - - - - - - - - - - - -

1

Access codes - - - - - - - - - - - - - - - -

2

How to operate Personal Attack - - - - - - 2 How to unset system in alarm - - - - - - - - 2

How to unset system in alarm

Enter your code. Entering the code will turn the alarm off and the cause of the alarm will be displayed. After investigation press Reset to clear the indication.

Programs 1, 2 and 3 - - - - - - - - - -

- - - 2

 

n

n

n

n

How to set the system (on program 1) -

- - - 3

 

 

 

 

 

 

Push to Set Switch - - - - - - - - - - -

- - - 3

 

 

 

Bell

 

 

Keyswitch Set - - - - - - - - - - - - -

- - - 3

 

 

 

Alarm

 

 

 

 

 

 

 

Faults during setting

3

 

 

 

 

 

 

 

 

 

 

 

How to unset the system (turn off) - -

- - - 3

 

 

FIRST ZONE IN ALARM

How to set program1,2 or 3 - - - - - -

- - - 3

 

 

OTHER ZONES IN ALARM

How to Quick set

4

 

 

 

 

 

 

 

 

How to Omit zone(s) on setting system

- - - 4

Investigate the Alarm

Fire Alarm - - - - - - - - - - - - - -

- - - 4

 

Reset

ALL ZONE

 

How to set Chime Zones

4

 

 

 

 

 

 

 

 

Operator’s Program mode - - - - - - -

5- - -

 

 

 

Strobe Off

 

 

 

To exit operation at any time

5

 

 

 

 

 

 

 

 

 

How to enter Operator’s program mode - - 5 How to view the events log - - - - - - - - - 5 How to create/omit User 2 code - - - - - - - 6 How to change current user code - - - - - - 6 How to carry out Alarm and Walk tests- - - 7

Servicing organisation details - - - - - - - - - 7 Quick Reference - - - - - - - - - - - - - - - 8

Access codes

There are two User codes used in the system, both are 4 digit and can be set to any number from 0000 to 9999, signified by:

n n n n

The user 1 and 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code.

User 1 code - 0123 factory set

User 2 code - not programmed.

How to operate Personal Attack

Personal Attack buttons on the keypad are used to activate the alarm, irrespective of whether the system is armed or not.

Press Simultaneously:

4 9

Day

Note: If the alarm indication does not clear, then the system may need to be reset by the installation engineer, contact your installer for further information.

Programs 1, 2 and 3

The panel uses 3 Part Set routines known as Programs. In each Program the exit mode can be changed and the zone may be set up to have a different function.

The examples below show how 3 typical Programs could be used in a house.

Program 1 To arm all of the zones and become Set as the user leaves the property and closes the final door.

Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds.

Program 3 To protect the downstairs areas of the house at night and become Set silently.

The above are purely examples. The installer has the ability at the programming stage to configure all the circuits to the customer’s exact requirements.

2

4188-693 issue 1_8/01

Citadel XR1 G3 intruder system

Operating instructions

 

 

How to set the system (on

How to unset the system (turn

program 1)

off)

The green Day indicator should be showing.

 

 

 

 

 

 

Enter your code

 

 

 

 

 

 

number and check

 

 

 

 

 

 

that the system is

 

 

Day

 

 

 

clear (none of the

 

 

 

 

 

 

zone indicators

n

n

n

 

n

are showing). The

 

 

 

 

 

 

sounder will now

 

 

Exit beep

 

 

10seconds

produce an exit

 

 

 

 

 

 

 

 

 

insistent beeps

beep tone and you

 

 

Day

 

 

 

should leave by

 

 

 

 

 

 

the approved

 

 

 

 

 

 

route. The system

 

 

 

 

 

 

will Set as the

 

 

 

 

 

 

beep tone stops.

On entering the premises an entry beep tone come on. Enter your code, the green Day indicator is lit. The system is unset and disarmed.

Entry beep

Day

n n n n

Acknowledge

Day

Push to Set Switch

In some systems a Push to Set switch may be fitted outside the premises near to the main exit door. This should be used to complete the setting procedure once the building has been vacated. As the switch is operated, the exit beep tone will stop and a chime tone will be produced to acknowledge setting.

Keyswitch Set

Your system may have been fitted with a remote keyswitch. This can be used as an alternative to arming the system with a code and will set Program 1.

Where a keyswitch is used it may be necessary on occasions to allow it to catch up with the system. For example if the alarm was set with a code, to Unset with the keyswitch, it would have to be momentarily turned to Set then returned to Unset.

Faults during setting

If the system is not clear when you try to Set it, the sounder will produce an open zone tone and the fault will be displayed. Either re-enter your code to turn off and investigate or omit the faulty zone(s) from the system.

How to set program 1,2 or 3

The green Day indicator should be showing. Enter your code

 

Day

 

 

number and the

 

 

 

 

n

n

n

n

exit beep tone

will start. Press

 

 

 

 

 

Exit beep

 

the Prog key and

Prog

 

ZONE 1-3

 

the exit tone will

 

Exit beep

stop. Press 1, 2

1

2

Or 3

 

or 3 for the

 

required

 

 

 

 

 

Exit beep

10 seconds

program, the

 

insistent beeps

sounder will

 

 

 

Day

 

 

beep to

 

 

 

 

acknowledge the

program number. The exit beep tone will start and you should leave by the approved route. The system will Set as the beep tone stops.

It is important that you follow the correct procedure when setting the system. After leaving the protected area it is absolutely essential that you wait until the exit tone stops, before assuming the system has set.