Citadel XR1 User Manual

r
r
XR1
8EP 394 XR1 G3 panel with built-in keypad
1 2 3 4 5 6 7 8
Power
0123
Attack
5678
Tamper
Chime Omit
Day
/!
Accenta
mini
Intruder alarm system
Operating Instructions
These operating instructions cover the following intruder system:
8EP 394 XR1G3
4
PA
9
Prog
Reset
Set
panel with built in keypad
For Clarity, the information given on setting the system, assume that all Programs use a timed or final door setting routine.
1 2 3 4 5 6 7 8
Key
LED steady On indication
LED flashing indication
LED Off
Internal sound
Sound description
NOTE: In general a flat beep is an indication of an incorrect key press.
External devices
Strobe
Bell
Power
Attack
Tamper
Day
0123
5678
Chime Omit
Reset
Prog
4
PA
9
Set
Unset system indications
An unset system will have both Day and Power
Day
indicators lit. This is a normal
Powe
indication when the system is disarmed.
Note: If the Power indicator goes off at any time then there is a mains supply failure at the security panel, consult your servicing organisation.
Set System indication
An active ‘Set’ system will have only the Power
indicator lit. This is an armed
Powe
system indication.
Unset system indications
4188-693 issue 1_8/01 1
Downloaded from: http://www.guardianalarms.net
Operating instructions Citadel XR1 G3 Intruder system
Contents
Unset system indications -----------1 Set System indication ------------1 Access codes ----------------2
How to operate Personal Attack ------2 How to unset system in alarm --------2
Programs 1, 2 and 3 -------------2
How to set the system (on program 1) ----3
Push to Set Switch --------------3 Keyswitch Set ----------------3 Faults during setting -------------3
How to unset the system (turn off) -----3 How to set program1,2 or 3 ---------3 How to Quick set --------------4 How to Omit zone(s) on setting system - - - 4
Fire Alarm -----------------4
How to set Chime Zones ----------4
Operator’s Program mode ----------5 To exit operation at any time ---------5
How to enter Operator’s program mode - - 5 How to view the events log ---------5 How to create/omit User 2 code -------6 How to change current user code ------6 How to carry out Alarm and Walk tests- - - 7
Servicing organisation details---------7 Quick Reference ---------------8
Access codes
Access codes
There are two User codes used in the system, both are 4 digit and can be set to any number from 0000 to 9999, signified by:
n n n n
The user 1 and 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code.
User 1 code - 0123 factory set
User 2 code - not programmed.
How to operate Personal Attack
Personal Attack buttons on the keypad are used to activate the alarm, irrespective of whether the system is armed or not.
Press Simultaneously:
9
4
How to unset system in alarm
Enter your code. Entering the code will turn the alarm off and the cause of the alarm will be displayed. After investigation press Reset to clear the indication.
n n n n
Bell
Alarm
FIRST ZONE IN ALARM
OTHER ZONES IN ALARM
Investigate the Alarm
Reset
ALL ZONE
Strobe Off
Day
Note: If the alarm indication does not clear, then the system may need to be reset by the installation engineer, contact your installer for further information.
Programs 1, 2 and 3
The panel uses 3 Part Set routines known as Programs. In each Program the exit mode can be changed and the zone may be set up to have a different function.
The examples below show how 3 typical Programs could be used in a house.
Program 1 To arm all of the zones and become Set as the user leaves the property and closes the final door.
Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds.
Program 3 To protect the downstairs areas of the house at night and become Set silently.
The above are purely examples. The installer has the ability at the programming stage to configure all the circuits to the customer’s exact requirements.
2 4188-693 issue 1_8/01
Citadel XR1 G3 intruder system Operating instructions
s
p
How to set the system (on program 1)
The green Day indicator should be showing.
Enter your code number and check that the system is
Day
clear (none of the zone indicators
n
n n n
are showing). The sounder will now
Exit beep
Day
10seconds insistent beep
produce an exit beep tone and you should leave by the approved route. The system will Set as the beep tone stops.
Push to Set Switch
In some systems a Push to Set switch may be fitted outside the premises near to the main exit door. This should be used to complete the setting procedure once the building has been vacated. As the switch is operated, the exit beep tone will stop and a chime tone will be produced to acknowledge setting.
Keyswitch Set
Your system may have been fitted with a remote keyswitch. This can be used as an alternative to arming the system with a code and will set Program 1.
Where a keyswitch is used it may be necessary on occasions to allow it to catch up with the system. For example if the alarm was set with a code, to Unset with the keyswitch, it would have to be momentarily turned to Set then returned to Unset.
How to unset the system (turn off)
On entering the premises an entry beep tone come on. Enter your code, the green Day indicator is lit. The system is unset and disarmed.
Entry beep
Day
n n n n
Acknowledge
Day
How to set program 1,2 or 3
The green Day indicator should be showing.
Day
n n n n
Exit beep
2
Exit beep
Day
ZONE 1-3
Or
Exit bee
3
10 seconds insistent beeps
Prog
1
program number. The exit beep tone will start and you should leave by the approved route. The system will Set as the beep tone stops.
Enter your code number and the exit beep tone will start. Press the Prog key and the exit tone will stop. Press 1, 2 or 3 for the required program, the sounder will beep to acknowledge the
How to set the system (on program 1)
It is important that you follow the correct
Faults during setting
If the system is not clear when you try to Set it, the sounder will produce an open zone tone and
procedure when setting the system. After leaving the protected area it is absolutely essential that you wait until the exit tone stops, before assuming the system has set.
the fault will be displayed. Either re-enter your code to turn off and investigate or omit the faulty zone(s) from the system.
4188-693 issue 1_8/01 3