For optimum efficiency and safety, we recommend that you read the manual before operating the equipment. Store this
manual in a file or binder and keep for future reference.
WARNING: Purchaser must post the following notice in a prominent location:
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion or to prevent property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this
or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
WARNING: In the event the user smells gas odor, instructions on what to do must be posted in a
prominent location. This information can be obtained from the local gas supplier.
WARNING: Wear safety shoes to prevent injuries.
WARNING: Purchaser must post the following notice in a prominent location:
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING: A clothes dryer produces combustible lint and should be exhausted outside the building.
The dryer and the area around the dryer should be kept free of lint.
WARNING: Be safe, before servicing machine, the main power should be shut off.
Page 2
ATTENTION: LACHETEUR DOIT PLACER LAVERTISSEMENT
SUIVANT DANS UN ENDROIT CLAIR ET VISIBLE:
AVERTISSEMENT. Assurez-vous de bien
suivre les instructions donnees dans cette
notice pour reduire au minimum le risque
dincendie ou dexplosion ou pour eviter tuot
dommage materiel, toute blessure ou la mort.
__ Ne pas entreposer ni utiliser dessence ni
dautres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
apparell.
__ QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter dallumer dapparell.
Ne touchez a aucun interrupteur. Ne pas
vous servir des telephones se trouvant dans
le batiment ou vous vous trouvez.
Evacuez la piece, le batiment ou la zone.
Appelez immediatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
__ linstallation et lentretien doivent etre assures
par un installateur ou un service dentretien
qualifie ou par le fournisseur de gaz.
ATTENTION: LACHETEUR DOIT PLACER LAVERTISSEMENT
SUIVANT DANS UN ENDROIT CLAIR ET VISIBLE:
POUR VOTRE SECURITE
Ne pas entreposer ni utiliser d essence
ni dautres vapeurs ou liquides
inflammables dans le voisinage de cet
appareil ou de tout autre appareil.
Page 3
WARNING: To avoid fire hazard, do not dry articles containing foam rubber or similar
texture materials. Do not put into this dryer flammable items such as baby bed
mattresses, throw rugs,undergarments (brassieres, etc.) and other items which use
rubber as padding or backing. Rubber easily oxidizes causing excessive heat and
possible fire. These items should be air dried.
WARNING: Synthetic solvent fumes from drycleaning machines create acids when drawn
through the dryer. These fumes cause rusting of painted parts, pitting of bright or plated
parts, and completely removes the zinc from galvanized parts, such as the tumbler basket. If
drycleaning machines are in the same area as the tumbler, the tumbler's make-up air must
come from a source free of solvent fumes.
WARNING: Do not operate without guards in place.
WARNING: Check the lint trap often and clean as needed but at least a minimum of once per day.
WARNING: Alterations to equipment may not be carried out without consulting with the
factory and only by a qualified engineer or technician. Only Manufactures parts may be
used.
WARNING: Remove clothes from dryer as soon as it stops. This keeps wrinkles from
setting in and reduces the possibility of spontaneous combustion.
WARNING: Be safe - shut main electrical power and gas supply off externally before
attempting service.
WARNING: Never use drycleaning solvents, gasoline, kerosene, or other flammable liquids
in the dryer. FIRE AND EXPLOSION WILL OCCUR. NEVER PUT FABRICS
TREATED WITH THESE LIQUIDS INTO THE DRYER. NEVER USE THESE
LIQUIDS NEAR THE DRYER..
WARNING: Do not place items exposed to cooking oils in your dryer. Items contaminated
with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
WARNING: Never let children play near or operate the dryer. Serious injury could occur if a child
should crawl inside and the dryer is turned on.
WARNING: Never tumble fiberglass materials in the dryer unless the labels say they are machine
dryable. Glass fibers break and can remain in the dryer. These fibers cause skin irritation if they
become mixed with other fabrics.
WARNING: Before operating gas ignition system - purge air from natural gas or propane gas lines
per manufacturers instructions.
WARNING: To reduce the risk of electric shock, disconnect this appliance from the power supply
before attempting any user maintenance other than cleaning the lint trap. Turning the controls to the
OFF position does not disconnect this appliance from the power supply.
Page 4
CISSELL DRYER WARRANTY
The Cissell Manufacturing Company (Cissell) warrants all new equipment (and the original parts thereof) to be free from
defects in material or workmanship for a period of three (3) years from the date of sale thereof to an original purchaser for
use, except as hereinafter provided. With respect to non-durable parts normally requiring replacement in less than three (3)
years due to normal wear and tear, and with respect to all new repair or replacement parts for Cissell equipment for which
the three (3) year warranty period has expired, or for all new repair or replacement parts for equipment other than Cissell
equipment, the warranty period is limited to ninety (90) days from date of sale. The warranty period on each new replacement
part furnished by Cissell in fulfillment of the warranty on new equipment or parts shall be for the unexpired portion of the
original warranty period on the part replaced.
With respect to electric motors, coin meters and other accessories furnished with the new equipment, but not manufactured
by Cissell, the warranty is limited to that provided by the respective manufacturer.
Cissell's total liability arising out of the manufacture and sale of new equipment and parts, whether under the warranty or
caused by Cissell's negligence or otherwise, shall be limited to Cissell repairing or replacing, at its option, any defective
equipment or part returned f.o.b. Cissell's factory, transportation prepaid, within the applicable warranty period and found
by Cissell to have been defective, and in no event shall Cissell be liable for damages of any kind, whether for any injury to
persons or property or for any special or consequential damages. The liability of Cissell does not include furnishing (or
paying for) any labor such as that required to service, remove or install; to diagnose troubles; to adjust, remove or replace
defective equipment or a part; nor does it include any responsibility for transportation expense which is involved therein.
The warranty of Cissell is contingent upon installation and use of its equipment under normal operating conditions. The
warranty is void on equipment or parts; that have been subjected to misuse, accident, or negligent damage; operated under
loads, pressures, speeds, electrical connections, plumbing, or conditions other than those specified by Cissell; operated
or repaired with other than genuine Cissell replacement parts; damaged by fire, flood, vandalism, or such other causes
beyond the control of Cissell; altered or repaired in any way that effects the reliability or detracts from its performance,
or; which have had the identification plate, or serial number, altered, defaced, or removed.
No defective equipment or part may be returned to Cissell for repair or replacement without prior written authorization
from Cissell. Charges for unauthorized repairs will not be accepted or paid by Cissell.
CISSELL MAKES NO OTHER EXPRESSED OR IMPLIED WARRANTY, STATUTORY OR OTHERWISE,
CONCERNING THE EQUIPMENT OR PARTS INCLUDING, WITHOUT LIMITATION, A WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, OR A WARRANTY OF MERCHANTABILITY. THE
WARRANTIES GIVEN ABOVE ARE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED
OR IMPLIED. CISSELL NEITHER ASSUMES, NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT,
ANY OTHER WARRANTY OR LIABILITY IN CONNECTION WITH THE MANUFACTURE, USE OR SALE OF ITS
EQUIPMENT OR PARTS.
For warranty service, contact the distributor from whom the Cissell equipment or part was purchased. If the distributor
cannot be reached, contact Cissell.
IDENTIFICATION NAMEPLATE
The identification nameplate is located on the rear wall of the dryer. It contains the dryer serial number, product number, model
number, electrical specifications and other important data that may be needed when servicing and ordering parts, wiring diagrams,
etc. Do not remove this nameplate.
The following symbols are used in this manual and/or on the machine.
NOTE!
Hot! Do Not Touch
Heiß! Nicht Beruhren
Haute temperature! Ne pas
toucher
Caliente! no tocar
dangerous voltage
tension dangereuse
Gefährliche elektrische
Spannung
tension peligrosa
On
Marche
Ein
Conectado
Off
Arrêt
Aus
Desconectado
DescriptionSymbol
Rotation in two directions
Rotation dans les deux sens
Drehbewigung in zwei
Richtungen
Movimiento rotativo en los
dos sentidos
Direction of rotation
Sens de mouvement continu
De rotation Drehbewegung
in Pfeilrichtung movimiento
Giratorio o rotatorio en el
sentido de la flecha
End of Cycle
Caution
Attention
Achtung
Atencion; precaucion
Symbol
Start
Demarrage
Start
Arranque de un
movimiento
Emission of heat in general
Emission de chaleur en
general
Warmeabgabe allgemein
Emisión de calor
Cooling
Refroidissement
Kühlen
Enfriamiento
Page 7
Unpacking/General Installation (All Dryers)
UNPACKING
GENERAL
INSTALLATION (ALL
DRYERS)
Upon arrival of the equipment, any damage in shipment should be
reported to the carrier immediately.
Upon locating permanent location of a unit, care should be taken in
movement and placement of equipment.
See outline clearance diagrams for correct dimensions.
Remove all packing material such as: tape, manuals, skid, etc
Leveling: Use spirit level on top of dryer. Adjust leveling bolts on
dryer (see adjustable leveling bolts in maintenance section).
Check voltage and amperes on rating plate before installing the dryer.
The construction of the dryers permits installation side-by-side to
save space or to provide a wall arrangement. Position dryer for the
least amount of exhaust piping and elbows, and allow free access to
the rear of dryer for future servicing of belts, pulleys and motors.
Installation clearance from all combustable material is 0" ceiling
clearance, 0" rear clearance, and 0" side clearance.
Before operating dryer, open basket door and remove blocking
between front panel and basket. Read the instruction tags, owners
manual, warnings, etc.
IMPORTANT
Opening the clothes loading door deactivates the door switch
to shut off the motors, fan, gas, steam, or electric element. To
restart the dryer, close the door and press in the push to start
button.
IMPORTANT
This dryer is designed for a capacity maximum load.
Overloading it will result in long drying times and damp spots
on some clothes.
IMPORTANT
Maximum operating efficiency is dependent upon proper air
cIrculation. The lint screen must be kept cleaned daily to
insure proper air circulation throughout the dryer.
IMPORTANT
Provide adequate clearance for air opening into the combustion
chamber.
Page 8
Unpacking/General Installation (All Dryers)
GENERAL
INFORMATION
DRYER
COOL-DOWN
CYCLE
The dryer is so designed that when an operator opens the dryer
door, the basket and exhaust fan stop. You can expect fast drying
from the laundry dryer. Hot, dry air is properly and effectively
moved through the basket and exhausted through a lint trap to the
atmosphere. The dryer comes equipped with an inclined selfcleaning lint screen. In this system, lint accumulates on the
underside of the screen until a blanket of lint will fall from the
screen to the bottom of the dryer cabinet, and should be removed
daily or as required, to prevent an over-accumulation.
IMPORTANT
Provide adequate clearance for air openings into the combustion
chamber.
Permanent press, durable press and other modern day fabrics
require the care that your laundry dryers now provide. At the end of
the drying cycle, a timed Cool-Down control automatically takes
over and continues the rotation of the fan and basket without heat
until the garment load reaches a safe cool temperature. This
function is performed at the end of each drying cycle.
REPLACEMENT
PARTS
Replacement parts for this dryer are available from your distributor
or by contracting the factory at the address or phone number printed
on the cover page of this manual.
Page 9
50 lb. Dryer Dimensions - Standard Gas, Steam and Electric Heated
S pe c ific a tio nsU .S . M e a su re
Capacity
(D ry Linen)
50 lbs.22.7 kg
Metric
Measure
Basket
Diameter33 inches838 mm
Depth32 inches813 mm
Volume15.8 ft
3
.448
liters
Cabinet
Height75.25 inches1911 mm
Width34.37 inches873 mm
Depth48.25 inches1226 mm
Door Opening
Diameter22.62 inches575 mm
Lo ading height31 .5 inches800 mm
Te m pe rature
M inimum10 0
Maximum185
0
F38
0
F85
o
C
0
C
Motor
Non-reversing1/2 H.P.0.37 kW
Reversing - Drum1/2 H.P.0.37 kW
Fan1/2 H.P.0.37 kW
E xhaust
3
Flow Rate850 C FM1445 m
/h
Diameter8 inches203 mm
E le ctric C onn. - E le ctric D rye rs
N on-R ev ersingRev ersing
208 V50/60 - 3PH89 A88 A
240 V50/60 - 3PH72/78 A72/78 A
380/415 V50 - 3PH44 / 48 A43/46 A
480 V60 - 3PH38 A39 A
Electric C onn. - Steam , G as D rye rs
N on-R e versingR eve rsing
120/208-240 V50 / 60 - 1 PH10.6/5.4 A11.1 A / 5.1 A
208/240 V50 / 60 - 3 PH4.2 / 4.1 A3.3 / 3.0 A
480 V60 - 3 PH1.6 A2.3 A
380/415 V50 - 3 PH1.7 A / 1.8 A2.2 A / 2.3 A
Power
Electric30 KW25,800 kcal/h
Gas130,000 B tu/h32,759 kcal/h
Steam4.8 B.H.P40,540 kcal/h
Steam connection
Inlet3 /4"D N 2 0
Outlet1/2"D N15
G as C onne ctio n
Gas Connection1/2"DN15
Gas Pressure6" - 12" w.c.15-30 (mbar)
Shipping
D im ensions
(H xW x D)
81.5 X 37 X
52.37 inches
2070 X 940
X 1330 mm
Weight
Gas/Elec. N et701 lbs.318 kg
Gas/Elec. G ross732 lbs.332 kg
Steam N et725 lbs.329 kg
Steam G ross762 lbs.346 kg
Page 10
HD50.1 Dryer Dimensions - Gas
Page 11
Electric connection
Dryers must be electrically grounded by a separate #14 or larger green wire from the grounding terminal
within the Service Connection Box, to a cold water pipe. In all cases, the grounding method must comply
with local electrical code requirements; or in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70 or the Canadian Electrical Code, CA C22.1.
See wiring diagram furnished with dryer. Do not change wiring without consulting the factory, as you may
void the factory warranty. DO NOT CONNECT THE DRYER TO ANY VOLTAGE OR CURRENT OTHER
THAN THAT SPECIFIED ON THE DRYER RATING PLATE. (Wiring diagram is located on rear wall of dryer.)
All panels must be in position before operation of dryer.
The connection needs to be made in the wiring box at the back. Open the coverplate
(G) in order to reach the connection clamps.
The connection cable needs to be brought in through the opening on the side of the
wiring box.
It is necessary to ground the dryer for your personal safety and to ensure a good
operation.
G
3 X 380-415 + N
3 X 208-240V
208-240V
115 and 208-240 V - 1 ph
The mains wires (Ll) and (L2) should be connected to the 2 left blocks and the
yellow/green grounding wire (PE) should be connected to the grounding block.
208-240 and 480 V - 3 ph
The 3 mains wires (L1), (L2) and (L3) should be connected to the 3 left blocks and
the yellow/green grounding wire (PE) should be connected to the grounding
block.
PE
L1 L2 L3 N
380-415V - 3 ph
The 3 mains wires (L1), (L2) and (L3) should be connected to the 3 left blocks,
the blue neutral (N) should be connected to the right block and the yellow/greengrounding wire (PE) should be connected to the grounding block.
«Attention. Lors des opérations dentretien
des commandes, ètiqueter tous les fils avant
de les dèconnecter. Toute erreur de câblage
peut être une source de danger et de panne»
Page 12
Gas connection
The gas supply pipe should be connected to the union (I), which is on the right next
to the wiring box on the back.
It is very important to have the connections done by a qualified technician, in order
to make sure that the installation is effected in accordance with the prevailing
standards and instructions.
The dryer should be connected to the type of gas, which is indicated on the serial plate.
The use of too small gas pipes can result in unsufficient gas supply, which can lead
to a bad heating-up and a poor drying quality.
I
When the dryer is used in combination with a weighing platform, the gas supply
pipe has to be made of flexible material to allow the weighing system to keep
moving freely.
Test all connections for possible leaks by means of a soap solution, but
never with a flame.
It is important to work with the right gas pressure (see technical remarks) in order to
obtain a good ignition, heating and consequently a good operation in general.
After the gas supply has been connected, the gas tap in the dryer should beturned on
(clockwise).
Page 13
Gas Piping Installation
GAS PIPING
INSTALLATION
1. The installation must conform with local codes, or in the
absence of local codes with the National Fuel Gas Code as,
ANSI Z223.1 or the CAN/CGA-B149, Installation Codes.
2. Check identification nameplate for type of gas for dryer.
3. Check the altitude of dryer.
4. Check with utilities company for proper gas pressure and gas
supply line.
5. Natural gas onlycheck the gas pressure inlet supply to
dryer, 11 water column (27.4 mbar) maximum. Manifold
pressure3.5 water column (8.8 mbar) pressure .
6. L.P. gas onlymanifold pressure13 water column (32.4
mbar) maximum.
CAUTION: Low gas pressure and intermittent gas will cause
gas ignition problems and inadequate drying of laundry.
Page 14
Gas Piping Installation (Illustrations)
The dryer and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psi (.04 bar).
The dryer must be isolated from the gas supply piping system by closing it's individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 1/2 psi (.04 bar).
Page 15
Gas Service Installation Instructions
GAS SERVICE
INSTALLATION
INSTRUCTIONS
The size of the gas service pipe is dependant upon many variables,
such as tees, lengths, etc. Specific pipe size should be obtained from
the gas supplier. Refer to the Gas Pipe Size chart in this manual for
general gas pipe size information.
CAUTION: Gas loop piping must be installed as illustrated
to maintain equal gas pressure for all dryers connected to a
single gas service
Other gas-using appliances should be connected upstream
from the loop.
GAS PRESSURE
REGULATOR FOR
LIQUIFIED
PETROLEUM GASES
WARNING:
LIQUIFIED PETROLEUM GASES ONLY !
A gas pressure regulator for liquified petroleum gases is not
furnished on the gas heated clothes dryers. This regulator is normally
furnished by the installer. In accordance with American Gas
Association (AGA) standards, a gas pressure regulator, when
installed indoors, must be equipped with a vent limiter or a vent line
must be installed from the gas pressure regulator vent to the outdoors.
Page 16
Gas Pipe Size Chart
TOTAL BTU/HR
(for LP Gas correct
total BTU/HR below by
multiplying by .6)
60,000
80,000
100,000
120,000
140,000
160,000
180,000
200,000
300,000
400,000
500,000
600,000
700,000
800,000
900,000
1,000,000
1,100,000
1,200,000
1,300,000
1,400,000
1,500,000
1,600,000
1,700,000
1,800,000
1,900,000
2,000,000
2,200,000
2,400,000
2,600,000
2,800,000
3,000,000
3,200,000
3,400,000
3,600,000
3,800,000
4,000,000
TOTAL
KCAL
HOUR
15000
20000
25200
30200
35200
40300
45300
50400
75600
100800
126000
151200
176400
202000
230000
250000
270000
300000
330000
350000
380000
400000
430000
450000
480000
504000
550000
605000
650000
705000
750000
806000
850000
907000
960000
1000000
(25 ft.)
7,62 m
3/4
3/4
3/4
3/4
3/4
3/4
1
1
1
1 1/4
1 1/4
1 1/2
1 1/2
1 1/2
2
2
2
2
2
2
2
2
2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
3
3
3
3
3
GAS PIPE SIZE FOR 1000 BTU (250 KCAL) NATURAL GAS
In figuring total length of pipe, make allowance for tees and elbows.
(50 ft.)
15,24 m
1 1/4
1 1/4
1 1/2
1 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
3 1/2
3 1/2
3 1/2
3 1/2
AT 7 (17.5 MM) W.C. PRESSURE
(75 ft.)
22,86 m
3/4
3/4
3/4
1
1
1
1
1
2
2
2
2
2
2
3
3
3
3
3
3
3/4
3/4
1
1
1
1
1
1 1/4
1 1/4
1 1/2
1 1/2
2
2
2
2
2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
3
3
3
3
3
3
3
3 1/2
3 1/2
3 1/2
3 1/2
3 1/2
3 1/2
(100 ft.)
30,48 m
3/4
1
1
1
1
1 1/4
1 1/4
1 1/4
1 1/2
1 1/2
2
2
2
2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
3
3
3
3
3
3
3
3 1/2
3 1/2
3 1/2
3 1/2
3 1/2
3 1/2
4
4
(125 ft.)
38,1 m
3/4
1
1
1
1
1 1/4
1 1/4
1 1/4
1 1/2
1 1/2
2
2
2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
3
3
3
3
3
3
3
3 1/2
3 1/2
3 1/2
3 1/2
3 1/2
3 1/2
4
4
4
4
(150 ft.)
45,72 m
3/4
1
1
1
1 1/4
1 1/4
1 1/4
1 1/2
1 1/2
2
2
2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
3
3
3
3
3
3
3
3 1/2
3 1/2
3 1/2
3 1/2
3 1/2
4
4
4
4
4
4
Page 17
Steam Piping Installation Instructions
STEAM PIPING
INSTALLATION
INSTRUCTIONS
1. Set and anchor dryer in position. Machine should be level to
assure proper steam circulation.
2. To prevent condensate draining from headers to dryer, piping
should have a minimum 12" above respective header. Do not
make steam connection to header with a horizontal or
downwardly facing tee or elbow.
3. Whenever possible, horizontal runs of steam lines must drain,
by gravity, to respective steam header. Water pockets, or an
imporperly drained steam header will provide wet steam,
causing improper operation of dryer. If pockets or improper
drainage cannot be eliminated, install a by-pass trap to drain
condensate from the low point in the steam supply header to
the return.
4. In both steam supply and steam return line, it is recommended
that each have a 3/4" union and 3/4" globe valve. This will
enable you to disconnect the steam connections and service
the dryer while your plant is in operation.
5. Before connecting trap and check valve to dryer, open globe
valve in steam supply line and allow steam to flow through
dryer to flush out any dirt and scale from dryer. This will
assure proper operation of trap when connected.
6. After flushing system, install bucket trap (with built-in
strainer) and check valve. For successful operation of dryer,
install trap 18" below coil and as near to the dryer as
possible. Inspect trap carefully for inlet and outlet markings
and install according to trap manufacturer's instructions. If
steam is gravity returned to boiler, omit trap but install check
valve in return line near dryer.
7. Install union and globe valve in return line and make final
pipe connections to return header.