Cissell HF 245 Installation Manual

Part No. D0052
Contents
1 General safety instructions .............................................................. 3
2 Technical data and dimensions ....................................................... 4
Technical data ................................................................................ 4
Dimensions ..................................................................................... 5
Ground ............................................................................................ 6
Removing the transport brackets .................................................... 6
Water connection ............................................................................ 6
Water drain ..................................................................................... 7
Main power connection .................................................................... 7
Automatic lubricator ........................................................................ 8
Liquid soap connection ................................................................... 9
Steam connection ........................................................................... 10
4 Operating instructions ..................................................................... 11
Machine with start button ................................................................ 11
5 Standard programs .......................................................................... 19
6 Technical remarks ............................................................................ 20
Internal connection of the electrical heating .................................... 20
Tilt switch ....................................................................................... 20
Error messages .............................................................................. 21
7 Maintenance of the machine ........................................................... 23
Code: 249/00179/00
18-12-00
Contents
General safety instructions
Ignoring any of the safety instructions can cause serious personal injury and can also cause damage to the linen or the machine
Read the installation and instruction manual carefully before connecting the
S
machine.
It is recommended that the machine be installed by qualified technicians.
S S
The machine should be installed according to the installation instructions. (See chapter 3)
S
The machine should be grounded according to the instructions in order to eliminate the risk of electrocution.
1
Do not expose the machine to high humidity or extreme high or low temperatures.
S
Cut off all main water inlets, steam and electrical supplies at the end of each
S
operating day.
Before starting repairs or maintenance, shut off all power and water supplies.
S
To prevent fire and explosion:
S
Keep the area around the machine free from inflammable or combustible products. Do not put fabrics that are treated with inflammable products into the machine. These fabrics should be hand-washed or air-dried first.
S
Always carefully read and follow the instructions on the packing of detergents. Store these products out of the reach of children.
Always take into account the instructions on the labels of clothes.
S
Never allow children to play in the surroundings of a machine.
S
Remark:
These instructions surely cannot prevent all risks of accidents. It is up to the user to act with the
S
utmost precaution.
Do not hesitate to contact the dealer in case of a problem.
S
3
Technical data and dimensions
Technical data
Capacity (dry weight)
1/11 1/10 1/9
Cylinder
Diameter Depth Volume
Cabinet
Height Width Depth
Front loading
Diameter door opening Door height - lower edge Door height - center
Speed
Wash Distribution Spin High spin
G-force
Spin High spin
Motors (3-phase)
4p. 1470 rot./min
Drain
Depend-O-Drain Option
Water-inlet
Hard, soft, hot water & cool-down
Steam connection
Steam connection
Heating
Electric 220/380 V Electric 380 V Steam Boiler fed Boiler fed (with auxiliary heating)
Packing dimensions
1730x1166x1130 mm
(H x W x D)
Weight
Net Gross
2
HF 245 HF 304
23 kg 28 kg 24,5 kg 30,4 kg 27,2 kg 33,3 kg
850 mm 850 mm 432 mm 537 mm
245 Lit. 304 Lit.
1530 mm 1530 mm 1060 mm 1060 mm
980 mm 980 mm
395 mm 395 mm 630 mm 630 mm 820 mm 820 mm
10...50 tr/min 100 tr/min
250...500 tr/min
500...1000 tr/min
84
383
4 kW
3" 2"
3/4"
3/8"
18 kW
18/24/30 kW
X X X
(HF245) 1730x1160x1230 mm (HF304)
845 kg 865 kg 928 kg 948 kg
4
Dimensions
2
A. Hard water connection 3/4"
S
B. Warm water connection 3/4"
S
C. Soft water connection 3/4"
S
D. Electrical connection
S
E. Electrical connection clamps
S
F. Output steam valve
S
G. Water drain
S
H. Steam connection
S
I. Ventilation soap dispenser
S
5
Installation and connection
Ground
The machine must be placed on a flat, solid surface (metal base, concrete or solid ground). It is recommended that the machine be anchored on the provided places (A) in the base, especially in case of a plinth (see Dimensions 2). The machine must be placed entirely level. For easy maintenance it is recommen­ded to keep a minimal distance of 600 mm between the wall and the back of the machine. If several machines are placed next to each another, there should be a minimal distance of 30 mm between each machine.
Removing the transport brackets
To prevent damage during transportation, the machine has been equipped with four red transport brackets (D) to eliminate every possible movement of the tub. After the machine has been placed level, take off the service- and the back panel to remove these transport brackets.
3
Water connection
Important
The machine must never be activated before removing these transport brackets.
The machine is delivered with hoses with 3/4" connections. These hoses fit the water inlet valves of the machine and the main water inlet taps. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 0,5 and 10 kg/cm² (7 and 145 psi). If the pressure is too low, the cycle time will increase considerably. In case of boiler fed machines, a minimum of hot water of 90°C should be available: For the HF245: 160 l. HF304: 180l.
6
3
Water drain
Main power connection
The machine is equipped with a drain valve with 3" outer diameter (80 mm). This drain valve should be connected to the drain by means of the drain elbow which is delivered with the machine.
The diameter of the main drain should be adapted to the water flow and
S
the number of machines. It should be sufficient to handle at least 160L/ min. per machine.
It is necessary to connect the main drain at least on one side to an open
S
air-brake to allow ventilation.
S
When the main drain has not been sufficiently deodorized, every machine should be installed seperately with a deodorizer.
Remove the cover plate at the back of the machine. (See dimensions (E)).
S
Connect the power cable to the connectors.
S
220V 3AC
220V 3 phase (3AC) should be connected to the connectors “L1,L2,L3”. The green/yellow grounding clamp has to be connected to the grounding wire “PE”.
380 V 3AC + N
Power of the breaker plugs:
380 V 3 phase (3AC + N) has to be connected to the connectors “L1,L2,L3”, the blue neutral to the “N” connector. The green/yellow grounding clamp has to be connected to the groun­ding wire “PE”.
After connection, check the spin direction. The cylinder must spin in the
S
direction of the arrow, showed on the sticker on the door window (clockwise). A wrong spin direction can damage the motor, and can also cause water to spurt from the soap dispenser.
In case of wrong spin direction: switch the terminal clamps of the motor
S
machine with steam heating or boiler fed machines without additional electrical heating
220V 3AC 380V 3AC + N
16 A 16 A
machine with electrical heating
220V 3AC 380V 3AC + N 18 kW 50 A 32 A 21 kW ---- 40 A 24 kW ---- 40 A 30 kW ---- 50 A
7
Loading...