7 Maintenance of the machine .......................................................... 29
Code: 249/00162/00
21/12/2000
Content
General safety instructions
Ignoring any of the safety instructions can cause serious
personal injury and can also cause damage to the linen or the
machine
Read the installation and instruction manual carefully before connecting the
S
machine.
It is recommended that the machine be installed by qualified technicians.
S
The machine should be installed according to the installation instructions.
S
(See chapter 4)
The machine should be grounded according to the instructions in order to
S
eliminate the risk of electrocution.
Do not expose the machine to high humidity or extreme high or low
S
temperatures.
Cut off all main water inlets, steam and electrical supplies at the end of each
S
operating day.
1
Before starting repairs or maintenance, shut off all power and water supplies.
S
To prevent fire and explosion:
S
Keep the area around the machine free from inflammable or combustible
products.
Do not put fabrics that are treated with inflammable products into the
machine. These fabrics should be hand-washed or air-dried first.
Always carefully read and follow the instructions on the packing of deter-
S
gents. Store these products out of the reach of children.
Always take into account the instructions on the labels of clothes.
S
Never allow children to play in the surroundings of a machine.
S
Remark:
These instructions surely cannot prevent all risks of accidents. It is up to the user to act with the
S
utmost precaution.
Do not hesitate to contact the dealer in case of a problem.
S
3
Technical data and dimensions
Technical data
Capacity (dry weight)
1/115 kg 6,6 kg8,6 kg
1/105,5 kg7,3 kg9,5 kg
1/9 6,1 kg8,1 kg10,5 kg
Cylinder
Diameter530 mm530 mm530 mm
Depth295 mm345 mm440 mm
Volume55 Lit.73 Lit.95 Lit.
Cabinet
Height1005 mm1005 mm1110 mm
Width660 mm660 mm660 mm
Depth 670 mm 670 mm770 mm
Front loading
Diameter door opening300 mm300 mm300 mm
Door height360 mm360 mm455 mm
To center510 mm510 mm605 mm
Speed
Wash50 rpm
Spin500 rpm
G-force
Spin74
Motor(3 phase)
Wash 18p. 290rpm120 W120 W120 W
Spin 2p. 2900 rpm370 W370 W550 W
Drain valve
Depend-O-Drain 6/4"
Water supply
Hard, soft, warm water and cool-down3/4"
Steam connection
Steam connection3/8"
Heating
Electrical 220/380 V4,2/6/9 kw
Electrical 380 V12 kw
SteamX
Warm water (without additional heating)X
Warm water (with additional heating)X
Packing dimensions
(H x W x D) 1140x732x832mm (WE55/73)
1230x732x950mm (WE95)
Weight
Net165 kg170 kg178 kg
Gross220 kg225 kg230 kg
2
WE 55WE 73WE 95
4
Capacity (dry weight)
Cylinder
Cabinet
Front loading
Speed
G-force
Motor(3 phase)
Drain valve
Water supply
Steam connection
Heating
Packing dimensions
Weight
2
WE 110WE 132WE 165
1/1110 kg 12 kg15 kg
1/1011 kg13,2 kg16,5 kg
1/912,2 kg14,5 kg18,3 kg
Diameter650 mm650 mm650 mm
Depth330 mm400 mm500 mm
Volume110 Lit.132 Lit.165 Lit.
Height1170 mm1170 mm1170 mm
Width780 mm780 mm780 mm
Depth 760 mm 760 mm860 mm
Diameter door opening300 mm300 mm300 mm
Door height465 mm465 mm465 mm
To center615 mm615 mm615 mm
Wash50 rpm
Spin500 rpm
Spin88
Wash 18p. 290rpm220 W220 W280 W
Spin 2p. 2900 rpm1100 W1100 W1300 W
Depend-O-Drain 6/4"
Hard, soft, warm water and cool-down3/4"
Steam connection3/8"
Electrical 220/380 V12/15/18 kw
Electrical 380 V21/24 kw
SteamX
Warm water (without additional heating) X
Warm water (with additional heating)X
(H x W x D) 1310x850x922mm (WE110/132)
1310x850x1022mm (WE165)
Net230 kg235 kg245 kg
Gross285 kg290 kg315 kg
5
DIMENSÕES
Dimensions
WE55/73/95
WE55/73/95
2
A. Hard water connection 3/4"
S
B. Warm water connection 3/4"
S
C. Soft water connection 3/4"
S
D. Electrical connection
S
E. Electrical connection clamps
S
F. Water drain
S
G. Steam connection
S
H. Ventilation soap dispenser
S
6
WE 110 / 132 / 165
2
A. Hard water connection 3/4"
S
B. Warm water connection 3/4"
S
C. Soft water connection 3/4"
S
D. Electrical connection
S
E. Electrical connection clamps
S
F. Water drain
S
G. Steam connection
S
H. Ventilation soap dispenser
S
7
Installation and connection
Surface
The machine must be securely fixed on a flat surface (metal base, concrete or
solid ground). The anchoring is to be done on the provided places (A) in the base.
(See Dimensions 2)
The machine must be placed entirely level. For easy maintenance it is recommended to keep a minimal distance of 600 mm between the wall and the back
of the machine.
If several machines are placed next to each another, there should be a minimal
distance of 30 mm between each machine.
Anchoring
On a metal base
3
D
E
F
D
B
C
C
G
The machines must be fixed on a metal base which is securely anchored on a
concrete base.
A: Bolt M12 (WE55/73/95), M16 (WE110/132/165)
B: Concrete base (WE55/73: 20cm, WE95/110: 30cm, WE132/165: 40cm)
C: Washer 40x17x4
D: Nut M12 (WE55/73/95), M16 (WE110/132/165)
E: Base of the machine
F: Metal base
A
Directly on the ground
The machine must be anchored directly on a concrete base.
The machine is delivered with hoses with 3/4" connections. These hoses fit the
water inlet valves of the machine and the main water inlet taps. To ensure the
optimal functioning of the water inlet valves, the water pressure on the inlet
should be between 0,5 and 10 kg/cm² (7 and 145 psi). If the pressure is too low,
the cycle time will increase considerably.
In case of boiler fed machines, a minimum of hot water of 90°C should be
available: For the WE55: 50 l. WE110: 90l.
For the WE73: 65 l. WE132: 120l.
For the WE95: 80 l. WE165: 140l.
8
3
Water drain
Main power connection
The machine is equipped with a drain valve with 6/4" outer diameter (50
mm). This drain valve should be connected to the drain by means of the
drain elbow which is delivered with the machine.
The diameter of the main drain should be adapted to the water flow and
S
the number of machines. It should be sufficient to handle at least 80L/
min. per machine.
It is necessary to connect the main drain at least on one side to an open
S
air-brake to allow ventilation.
Remove the cover plate at the back of the machine. (See dimensions
S
(E)).
S
Connect the power cable to the connectors.
220V 3AC
220V 3 phase (3AC) should be connected to the connectors “L1,L2,L3”.
The green/yellow grounding clamp has to be connected to the grounding wire “PE”.
380 V 3AC + N
Power of the breaker plugs:
380 V 3 phase (3AC + N) has to be connected to the connectors
“L1,L2,L3”, the blue neutral to the “N” connector.
The green/yellow grounding clamp has to be connected to the grounding wire “PE”.
After connection, check the spin direction. The cylinder must spin in
S
the direction of the arrow, showed on the sticker on the door window
(clockwise).
A wrong spin direction can damage the motor, and can also cause water
to spurt from the soap dispenser.
In case of wrong spin direction: switch the terminal clamps of the motor
S
circuit “R” and “S” of the connecting cable.
machine with steam heating or boiler fed machines without additional electrical heating
220V 3AC380V 3AC + N
16 A16 A
machine with electrical heating
Heating:220V 3AC380V 3AC + N
4,2 kw16A16A
6 kw16A16A
12 kW40 A20 A
15 kW50 A25 A
18 kW50 A32 A
21 kW----40 A
24 kW----40 A
9
Liquid soap connection (option)
3
Connection of the liquid soap
hoses
Electrical connection of
the liquid soap pumps
A rubber connection has been placed over the air break opening at the back
of the machine. There are 5 holes in this rubber connection, through each
of which a liquid soap hose can be driven (S1...S5). Press the hoses until
they appear well inside the soap dispenser.
The central gap in the rubber connection remains and serves as air breaker.
On machines equipped with a liquid soap connection, connect the wires
directly on the print board next to the ground wire connection (option).
Connect as indicated on the wiring diagram.
The two connectors on the right give a tension of 220V ~ (max. 4A) which
can be applied to drive 220V ~ soap pumps. If more than 4A is required,
an external tension will have to be used. 6 connections have been
provided, of which one (S6) can be used to drive a waterproofing pump
(e.g. for rain coats, etc.).
The 220V can be transformed to other values to drive other type soap
pumps.
Example: pumps 24V ~.
Also, pumps with different operating tension can be combined.
Example: 5 pumps 220V ~ and 1 pump 24V ~.
With an external tension 24V DC
10