Physical and Operating Environment Specifications

Table C-1 shows the physical and operating environment specifications for the Cisco Unified
IP Phone 6901.
Table C-1 Physical and Operating Environment Specifications for the Cisco Unified IP Phone 6901
C
Specification Value or Range
Operating temperature 23° to 113°F (-5° to 45°C)
Operating relative humidity 10% to 90% (non-condensing)
Storage temperature -13° to 158°F (–25° to 70°C)
Height 8.1 in. (20.5 cm)
Width 3.7 in. (9.4 cm)
Depth
Weight
Power
2.12 in. (5.4 cm)—With footstand closed
3.42 in. (8.7 cm)—With footstand open
1.37 lb (621.2 g)—Black handset phone (Europe)
1.37 lb (662 g)—White handset phone (Europe)
1.44 lb (655.2 g)—Black handset phone (North America)
1.53 lb (695 g)—White handset phone (North America)
100-240 VAC, 50-60 Hz, 0.5 A—When using the AC adapter
48 VDC, 0.2 A—When using the in-line power over the network cable
OL-24582-01
Cisco Unified IP Phone 6901 and 6911 Administration Guide for Cisco Unified Communications Manager 8.6 (SCCP and SIP)
C-1
Appendix C Technical Specifications

Cable Specifications

Table C-1 Physical and Operating Environment Specifications for the Cisco Unified IP Phone 6901 (continued)
Specification Value or Range
Cables Category 3/5/5e for 10-Mbps cables with four pairs
Category 5/5e for 100-Mbps cables with four pairs
Note Cables have four pairs of wires for a total of eight conductors.
Distance Requirements As supported by the Ethernet Specification, it is assumed that the maximum cable length
between each Cisco Unified IP Phone and the switch is 100 meters (330 feet).
Table C-2 shows the physical and operating environment specifications for the Cisco Unified IP Phone
Table C-2 Physical and Operating Environment Specifications for the Cisco Unified IP Phone 6911
Specification Value or Range
Operating temperature 23° to 113°F (-5° to 45°C)
Operating relative humidity 10% to 90% (non-condensing)
Storage temperature -13° to 158°F (–25° to 70°C)
Height 8.07 in. (20.5 cm)
Width 7.4 in. (18.8 cm)
Depth 5.76 in. (14.64 cm)—Excluding the handset
Weight
1.53 lb (697 g)—Black handset phone
1.65 lb (750.3 g)—White handset phone
Power
100-240 VAC, 50-60 Hz, 0.5 A—When using the AC adapter
48 VDC, 0.2 A—When using the in-line power over the network cable
Cables Category 3/5/5e for 10-Mbps cables with 4 pairs
Category 5/5e for 100-Mbps cables with 4 pairs
Note Cables have 4 pairs of wires for a total of 8 conductors.
Distance Requirements As supported by the Ethernet Specification, it is assumed that the maximum cable length
between each Cisco Unified IP Phone and the switch is 100 meters (330 feet).
Cable Specifications
RJ-9 jack (4-conductor) for handset connection.
RJ-45 jack for the LAN 10/100BaseT connection (labeled 10/100 SW on the Cisco Unified
IP Phone 6901 and 6911).
RJ-45 jack for a second 10/100BaseT compliant connection (labeled 10/100 PC on the
Cisco Unified IP Phone 6911).
48-volt power connector.
C-2
Cisco Unified IP Phone 6901 and 6911 Administration Guide for Cisco Unified Communications Manager 8.6 (SCCP and SIP)
OL-24582-01
Appendix C Technical Specifications

Network and Access Port Pinouts

Although both the network and access ports are used for network connectivity, they serve different purposes and have different port pinouts.
The network port is labeled network on the Cisco Unified IP Phone.
The access port is labeled Computer on the Cisco Unified IP Phone (Cisco Unified IP Phone 6911
only).
Network Port Connector
Table C-3 describes the network port connector pinouts.
Table C-3 Network Port Connector Pinouts
Pin Number Function
1BI_DA+
2BI_DA-
3BI_DB+
4BI_DC+
5BI_DC-
6BI_DB-
7BI_DD+
8BI_DD-
Note “BI” stands for bi-directional, while DA, DB, DC and DD stand for “Data A”, “Data
B”, “Data C” and “Data D”, respectively.
Network and Access Port Pinouts
Access Port Connector
Table C-4 describes the access port connector pinouts.
Table C-4 Access Port Connector Pinouts
Pin Number Function
1BI_DB+
2BI_DB-
3BI_DA+
4BI_DD+
5BI_DD-
6BI_DA-
7BI_DC+
8BI_DC-
Note “BI” stands for bi-directional, while DA, DB, DC and DD stand for “Data A”, “Data
B”, “Data C” and “Data D”, respectively.
OL-24582-01
Cisco Unified IP Phone 6901 and 6911 Administration Guide for Cisco Unified Communications Manager 8.6 (SCCP and SIP)
C-3
Network and Access Port Pinouts
Appendix C Technical Specifications
C-4
Cisco Unified IP Phone 6901 and 6911 Administration Guide for Cisco Unified Communications Manager 8.6 (SCCP and SIP)
OL-24582-01
Loading...